Monitoring solutions for 19" Racks (cabinets) in IT HW group www.hw-group.com
Poseidon 3262 Tset 600 257 Poseidon 3262 Temperature 1 placed next to technology - 1 Temperature ProtoCols WEB / http XML SNMP Email (R1) One Point: TH -> GSM, SNMP, Email
placed next to technology Poseidon 3265 GSM Tset 600 283 Poseidon 3265 Temperature 1 / Humidity 1 next to Air input %RH H 600 330 RS-232 GSM modem - 2 Temperatures - GSM: ProtoCols WEB / http XML SNMP Email for Admin as independent backup solution. (R2) One Point: TH -> GSM, SNMP, Email
Temperature 3 Temperature 1 / Humidity 1 Cold air ingress to cabinet %RH Poseidon 3266 Tset 600 253 Poseidon 3266-3 Temperatures - 4 Door contacts - 1 Power detection Power Power failure detector Door 1 Entrance door detector H 600 330 Det. CONTROL PowerEgg 600 237 4 Door Contacts 600 119 Door 2 Sides and backdoor detector 4m Protocols WEB / http XML SNMP Email SNMP trap for the video survaillance system (PTZ) (R3) One Rack: THD -> SNMP, Email
Temperature 3 Poseidon 1250 Tset 600 042 Poseidon 1250 Temperature 1 / Humidity 1 Cold air ingress to cabinet %RH 4m RS-232-3 Temperatures - 4 Door contacts - 1 Power detection Power Power failure detector Door 1 Entrance door detector - GSM: H 600 330 Det. CONTROL PowerEgg 600 237 4 Door Contacts 600 119 Door 2 Sides and backdoor detector GSM modem GSM Modemcom G10 600 312 Protocols for Admin as independent backup solution. WEB / http XML SNMP Email (R4) One Rack: THD -> SNMP, Email,
Temperature 1 Four free-standing racks Temp-1Wire 600 005 (in SET) - 5 Temperatures Placed in 4 19" Racks Temperature 3 Temperature 4 / Humidity 1 Cold air ingress to cabinet %RH H 600 330 Poseidon 3262 Protocols WEB / http XML SNMP Email Temperature 5 Poseidon 3262 Tset 600 257 (R5) Four Racks: TH -> SNMP, Email
Temperature 1 Four free-standing racks Temp-1Wire 600 005 (in SET) - 4 Temperatures Placed in 4 19" Racks - GSM: %RH H 600 330 Temperature 3 / Humidity 1 Cold air ingress to cabinet Poseidon 3265 Temperature 4 Poseidon 3265 GSM2 Tset 600 313 RS-232 GSM modem (R6) Four Racks: TH -> SNMP, Email,
- 2 Temperatures in the rack in the rack - 3 Contacts in the rack - 24 Temperatures in room Ceiling panel Ceiling to raised floor connection Raised floor Temperature 15 Temperature 16 Door 1 monitoring of the cabinet with the Poseidon unit General power input UPS power input Det Control Temperature 3 Temperature 4 Temperature 5 Temperature 6 Temperature 17 Temperature 18 Temperature 19 0 UPS output UPS backup power output Det Control Temperature 7 Temperature 8 Temperature 9 1 2 3 Temperature 1 monitoring of the cabinet with the Poseidon unit General room temperature Humidity 1 General room humidity %RH Temperature 10 Temperature 11 Temperature 12 Temperature 13 Temperature 14 4 5 7 (R7) ServerRoom: TH -> SNMP, Email
Four free-standing racks Monitored Rack: 1 Temperature 1 Doors Full monitored Rack: 3 Temperature 1 Humidity 1 Door %RH 600 273 to sensors in next cabinet.. - 8 Temperatures - 2 Humidity - 5 Door contacts Placed in 4 19" Racks + extension Monitored Rack: 1 Temperature 1 Doors - GSM: Full monitored Rack: 3 Temperature 1 Humidity 1+3 Doors %RH Poseidon 1250 RS-232 Poseidon 3265 GSM2 Tset 600 313 (optionaly) GSM modem Door 2 Sides and backdoor detector (R8) Four Racks + Customized extension: THD -> SNMP, Email, ()
Six free-standing racks Temperature 1 Temperature 3 Temp-1Wire 600 005 (in SET) - 5 Temperatures Placed in 4 19" Racks Temperature 4 Poseidon 3262 Poseidon 3262 Tset 600 257 Temperature 5 Temperature 6 (R9) Six Racks low-cost monitoring: T -> SNMP, Email