Pressure relief valve VRH 5 / VRH 30 / VRH 60 / VRH 120

Similar documents
Pressure relief valve VRH 5 / VRH 30 / VRH 60 / VRH 120

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

NK Multi-stage submersible pumps

Liberty Process Equipment, Inc.

BROEN UNIFLEX FITTINGS FOR WATER BROEN UNIFLEX TM FITTINGS FOR WATER

9 LABORATORY ACCESSORY

OASIS DP SANIC RO. Reverse Osmosis Units with Made in Italy components. Keep your filters protected with silver based Antimicrobial Technology

Smallest Connector with Removable Contacts

Hydraclaw Jacks. *dimensions are in mm. Powerful: 5 tonne capacity on head or toe. High Lift: 178mm. Fast Operation: 5.5mm lift per stroke

Ball Valve Manual Balance Hose Kits - Submittal

Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)

FBO-10 and FBO-14. Fuel Filter/Water Separator For High-Flow Applications. Product Features. Contact Information

Bourdon Tube Pressure Switches

INSTALLATION GUIDELINES

Specifications of KINEDIZER burners

Data Sheet for Precision Potentiometer

Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind.

Perrin & Rowe Kitchen ROHL Pull-Out/Pull-Down COLORS/FINISHES. Polished Chrome Polished Nickel Satin Nickel English Bronze Inca Brass* 9 1/4

DUPLEX STRAINERS 800-KECKLEY ( ) BULLETIN NO / FAX: 847/ WEB SITE:

DUPLEX STRAINERS BULLETIN NO KECKLEY COMPANY 3400 Cleveland Street P.O. Box 67 Skokie, Illinois 60076

Catalog 2018 SOLAR SHOWERS

Virto - the flexibility of a natural shape.

Table and Furniture Base Fittings Furniture Feets


Daikin Fire Rated Hoses & Hose Kits for Water Source Heat Pumps. Catalog People and ideas you can trust.

Trunk Connection Type (provided) FNPT (Std.) MNPT FSWT

Data Sheet for Precision Potentiometer

BROEN-LAB UNIFLEX FITTINGS FOR WATER BROEN-LAB UNIFLEX TM FITTINGS FOR WATER

NEW PRODUCT. Turn to the Harris. Pros

Mara. Bathroom. Bathroom. Fittings

PN 3000 Series Fail Closed Pneumatic Actuators

Clay Adaptors & Insert Stove Kits


Maintenance & Repair Instructions

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

300 Model 870 Four Wheel Hose Cart Owner s Manual

AQUAVALVE THROUGH BULKHEAD

TruDesign Aquavalve (Y Valve)

PBG PACKAGED GAS BURNERS

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

Cold Water Rheology Kit

Ultraflow Compact Housing and Winter Kit

The Shand & Jurs Model Pressure Relief Vent

D-SUB SERIES. Fast Locking System ESCC 3401/085. Features and Benefits. Typical Applications. Specification. Quality Level.

Available materials: Stainless steel AISI 304 (Application in wet areas). Stainless steel AISI 316 (Application in aggressive areas).

Accessories high-pressure cleaners:

Single, oversized roller compresses a low friction hose through a full 360-degree rotation

SS SERIES STAINLESS STEEL SLIDE GATE

Inflatable Tent. Medical, Decontamination, Activity

Manual Actuator. CR / CM Levers. Type Series Booklet

Model Number Structure

PortesPivotantes PivotTüren Porta-a-Bilico PivotDoors Taatsdeuren Пивот-дверь от компании PuertasPivotantes. يروحملا بابلا 轴门 PortasPivotantes

FLEXIBLE STAINLESS STEEL CONNECTION HOSES

AIR NOZZLES air knives & air curtains

A EURO-QUALIFLEX (AEQ) MEMBER. Publish date Rev. No: 01

technical documentation

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001

Eclipse Hermetic Gas Boosters Series HB

JARVIS. Model 70 Airsnip Air Powered Scissors

Dispenser DBN-EQ. Spare parts list Machine no: Previous:

MP02 series. Instruction and installation manual

SELF RE-ERECTING MARKER POSTS

Laboratory Line. Perfectly Equipped for Every Challenge. CoreLab DX. Laboratory Equipment

SILENT X-STREAM AIR BLADE AIR KNIFE. Blowoff, clean, cool and dry with this quiet, sharp and strong focused curtain of air

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

ACCESSORIES 5:05 5:05 PRODUCT CATALOGUE 189

Airport Compatibility Brochure 737 MAX. March 2014 PRELIMINARY

TECHNICAL BROCHURE BPRIMELINE R1. Marlow Series Prime Line SELF-PRIMING CENTRIFUGAL PUMPS TECHNICAL DATA

ANODIZED ALUMINUM STAINLESS CONSTRUCTION

industrial ball valves

The safe & affordable install

Dry Ice Blasting Unit

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

Sales support Global website

SILENT X-STREAM AIR BLADE AIR KNIFE Blowoff, clean, cool and dry with this quiet, sharp and strong focused curtain of air

Electrical Specifications. Dimensions (inches)

Electrical Specifications. Dimensions (inches)

FILTRONIC AB EXTRACTION ARMS AND NOZZLES FOR A BETTER WORKBENCH ENVIRONMENT

Foam Systems Engineering Design Manual

Section 11 Workstation Components

Cold Water Pressure Washers POSEIDON 8

Crystal Compact Housing and Winter Kit

NORMACLAMP Hose Clamps

Air inlet. 1. Drilled Pipe - Typically drilled pipe uses more compressed air while producing inconsistent flow at high noise levels.

4 Storage cupboards SCALA

Hose Clamps & Fittings

T&S BRASS AND BRONZE WORKS, INC.

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

2-3-5 Valve Manifolds

ELITE SERIES R-410A Ready - Multi-Position

Catalogue. Blowguns, Movers and Nozzles. brands products. JWL Blowgun Range 1. Brauer Air Movers and Cold Air Gun 6.

European Technical Assessment ETA-15/0677 of 29/10/2015

DC 700 Series Hose Reel - September 2010

Installation Instructions

Contents. Company Background FLOWSTOPPER Plugging Device Kit and Replacement Parts Key Features & Benefits... 4

Tools. For safety and easy faucet replacement, San-Ei recommends the use of the following helpful tools:

Preparation and Installation of the (VPC) Flat Circular Vent Panel

CARTRIDGE AND BAG UNIT. Passion for Filtration

SHOWERS & TAPWARE. Collection. Inspiration for planning your bathroom and kitchen

Nexus Standard Glove Box System

Transcription:

Data sheet Pressure relief valve VRH 5 / VRH / VRH 60 / VRH hpp.danfoss.com

Table of Contents Contents 1. Introduction...2 2. Features...2 3. Variants...2 4. Technical data...3 5. Flow...3 5.1 VRH 5 Max. flow 5 l/ min....3 5.2 VRH Max. flow l/min....4 VRH 60 Max. flow 60 l/min....4 5.4 VRH Max. flow l/min....5 5.5 VRH F Max. flow l/min.....5 6. Mounting...6 7. Operation...6 8. Dimensions...7 9. Spare parts...8 1. Introduction The relief valve is used for protecting the components of a system against overload as a result of a pressure peak. Further, the valve is designed for controlling/ limiting the system pressure by draining off the surplus water from the pressure side. The valve is designed for tap water, i.e. without additives of any kind to the medium. (EU-drinking water directive 98/83/EC). 2. Features Excellent functional characteristics. Surface easy to clean. Corrosion-proof parts (stainless steel, AISI 4, W. No. 1.41). 3. Variants The valves are available in four sizes: 5 l/min. l/min. 60 l/min. l/min. Standard versions made of rustproof steel AISI 4/W. No. 1.41. Upon request also available in versions made of stainless steel AISI 316L/W No. 1.4401 The relief valves are available with different pressure ranges. Danfoss DCS (im) 2018.09 521B0841 DKCFN.PD.040.A12.02 2

4. Technical data Type Code no. Pressure range barg (psig) Setting screw (min. to max.) mm (inch) Flow (max.) l/min. (gpm) Media and ambient temperature C ( F) Internal leakage 20% below max.. setting pressure l/min. (gpm) Weight kg (lbs) VRH 5 180G0034 25-100 (362-14) 5 (1.3) VRH 5 CA 1) 180G0033 25-100 (362-14) 5 (1.3) VRH 180G00 25-140 (362-20) (7.9) VRH 180G0029 10-40 (145-580) (7.9) VRH 180G0031 45-210 (652-45) (7.9) VRH CA 1) 180G0032 25-140 (362-20) (7.9) VRH 60 180G0002 25-80 (362-1160) 6.2 (0.24) 60 (15.8) 1.3 (2.4) VRH 60 180G0003 80-140 (1160-20) 6.2 (0.24) 60 (15.8) 1.3 (2.4) VRH 180G0020 25-80 (362-1160) 7.3 (0.28) (31.7) 2.8 (6.2) VRH 180G0021 80-140 (1160-20) 7.3 (0.28) (31.7) 2.8 (6.2) VRH F 2) 180G0035 80-140 (1160-20) 7.3 (0.28) (31.7) 2.8 (6.2) 1) Cartridge version 2) Fire fighting version - recommended inspection after 0 hours of operation 5. Flow 5.1 VRH 5 Max. flow: 5 l/min. Pressure setting range: 25-100 barg (362-14 psig) P [Bar] 1 110 100 90 80 70 60 25 to 100 40 20 10 0 0 1 2 3 4 5 Q [l/min] Danfoss DCS (im) 2018.09 521B0841 DKCFN.PD.040.A12.02 3

5.2 VRH Max. flow: l/min. Pressure setting range: 10-40 barg, 25-140 barg, 45-210 barg (145-180 psig, 362-20 psig, 652-45 psig) 10-40 VRH 60 Max. flow: 60 l/min. Pressure setting range: 25-80 barg, 80-140 barg (362-1160 psig, 1160-20 psig) Danfoss DCS (im) 2018.09 521B0841 DKCFN.PD.040.A12.02 4

5.4 VRH Max. flow: l/min. Pressure setting range: 25-80 barg, 80-140 barg (362-1160 psig, 1160-20 psig) 5.5 VRH F Max. flow: l/min. Pressure setting range: 80-140 barg (1160-20 psig) P [Bar] 180 160 140 100 80 to 140 80 60 40 20 0 0 20 40 60 80 100 Q [l/min] Danfoss DCS (im) 2018.09 521B0841 DKCFN.PD.040.A12.02 5

6. Mounting The valve is mounted in-line and fixed by means of the system s piping or fastened (only VRH ) by means of the two 8.4 mm holes in the valve. It is important that valve is bleed to avoid noise and therefore must the valve be mounted in the correct position - please see drawing 7. Operation Starting up To ensure stable working conditions for the valve it is very important to bleed the valve during starting up. Noise level Since the valve typically is mounted in-line or on a frame, the noise level can only be determined for the complete system, It is therefore very important that the valve is mounted correctly on a frame to minimize vibrations and noise. The noise level is influenced by: Mounting position of the valve is important to ensure a good bleeding of valve. Sufficient bleeding of the valve. High pressure generates more noise that low pressure. Rigid mounting of the valve generates mor noise than flexible mounting. Pipe mounting direct to the valve increases the noise level compared to a flexible hose connection. Filtration We strongly recommend that you always use precision depth filter cartridges in the system, rated 10 μm abs. β10 5,000. or better. Corrosion and frost protection If the valve is exposed to temperature below freezing, it must be protected against freezing. Danfoss recommends DOWCAL N or Zitrec FC antifreezes both being biologically degradable Mono Propylene Glycol (MPG). Danfoss DCS (im) 2018.09 521B0841 DKCFN.PD.040.A12.02 6

8. Dimensions 8.1 VRH 5, VRH, VRH 60 and VRH Type A B C D E F G 1 G 2 H J K L M N O P R VRH 5 109.6 89.2 AF4 AF13 98.2 33.5 16.8 18 42 G3/8-25 10 36 - - 12 VRH 109.6 89.2 AF4 AF13 98.2 33.5 16.8 18 42 G3/8-25 10 36 - - 12 VRH 60 151 117 AF5 AF19 129 42.5 21.2 21.2 55.5 G1/2-33 14 45 - - 21.5 VRH 202 165.5 AF8 AF24 182.5 60 75 G3/4 43 46.5 15 65 Ø8.4 20.4 8.2 VRH 5 CA and VRH CA Danfoss DCS (im) 2018.09 521B0841 DKCFN.PD.040.A12.02 7

9. Spare parts Valve size Description Code no. VRH 5 Valve seat and cone kit 25-100 barg (362-14 psig) 180G4018 VRH 5 Seal and spring kit 180G4019 VRH Valve seat and cone kit [pressure range 10-140 barg (145-20 psig)] 180G4000 VRH 5/ Guide and guide pin kit 180G4001 VRH Seal and spring kit [pressure range 10-40 barg (145-580 psig)] 180G4002 VRH 5/ Tool kit 180G4003 VRH Seal and spring kit [pressure range 25-210barg (362-45 psig)] 180G4004 VRH Valve seat and cone kit [pressure range 45-210 barg (362-45 psig)] 180G4005 VRH 60 Valve seat and cone kit [pressure range 10-140 barg (145-20 psig)] 180G4006 VRH 60 Guide and guide pin kit 180G4007 VRH 60 Seal and spring kit [pressure range 10-40 barg (145-580 psig)] 180G4008 VRH 60 Seal and spring kit [pressure range 25-60 barg (362-1160 psig)] 180G4009 VRH 60 Seal and spring kit [pressure range 80-140 barg (1160-20 psig)] 180G4010 VRH 60 Tool kit 180G4011 VRH Valve seat and cone kit [pressure range 25-140 barg (362-20 psig)] 180G4012 VRH Guide and guide pin kit 180G4013 VRH Seal and spring kit [pressure range 25-80 barg (362-1160 psig)] 180G4014 VRH Seal and spring kit [pressure range 80-140 barg (1160-20 psig)] 180G4015 VRH Tool kit 180G4016 VRH F Valve seat and cone kit [pressure range 80-140 barg (1160-20 psig)] 180G4020 9.1 Recommendation for build in a VRH 5/ CA Danfoss A/S High Pressure Pumps DK-64 Nordborg Denmark Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss DCS (im) 2018.09 521B0841 DKCFN.PD.040.A12.02 8