TC30 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS

Similar documents
TC36 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

TC42 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

TC36 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

TC36 COUNTRY HOME BURNER KIT INSTRUCTIONS (NATURAL GAS ONLY)

TC30 BLACK DIAMOND BURNER KIT INSTRUCTIONS

TC42 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

CHALET BURNER KIT TC42.NG01

TC36 SEE-THRU CHALET BURNER KIT INSTRUCTIONS

TC36 SEE-THRU LODGEWOOD BURNER AND PANEL KIT INSTRUCTIONS

TC42 TRANQUILITY BURNER KIT INSTRUCTIONS

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

TCWS.54NG03C2 BLACK DIAMOND BURNER KIT INSTRUCTIONS

TCWS54 BLACK DIAMOND BURNER KIT INSTRUCTIONS

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

INFRARED BURNER KIT INSTRUCTIONS

HD81 RIVER ROCK / STONE BURNER ASSEMBLY

HD81 RIVER ROCK / STONE BURNER ASSEMBLY

CONVERSION INSTRUCTIONS

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

Installation Guide. LPKPDR - Universal LP Conversion Kit for Professional & Designer Ranges/Rangetops. Viking Range, LLC.

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations

564 HO DancingFyre Burner Installation Instructions (sku: )

CONVERSION INSTRUCTIONS

TCWS54 SEE THRU LONG BEACH LOG INSTALLATION INSTRUCTIONS

33 DVI/Cypress Log Set Installation Instructions (sku )

Genesis. Side Burner Accessory Installation. Step 3. Step 1. Step 2. For use with Genesis Gas Barbecues Only

INFRARED BURNER KIT INSTRUCTIONS

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS JUMBO/JUMBO SLIMLINE LOG SYSTEMS

TUBULAR BURNER CONVERSION KIT AGCK-TBXX / AECK-UBXX

Thermostatic Griddle Field Service Kit Instructions

Installation GUIDE. NKVGR Natural Conversion Kit for 7 Series Ranges/Rangetops

Assembly/Installation/Use Instructions:

Gas Conversion Kits and Instructions

TECHNICAL SUPPORT HOT LINE HOURS: 7:30-3:30

Fyre-Stones Set C Installation Instructions (sku )

For converting 72 PKN for use with (LP) propane gas.

INSTRUCTIONS FOR MVK-NQM PILOT KIT

NATURAL GAS CONVERSION KIT

SERVICE MANUAL V-SERIES HEAVY DUTY BROILERS, DOUBLE DECK AND RANGE MATCH MODELS - NOTICE - For a complete listing of models, see the MODELS section.

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

Colonial and Grand Colonial Fire Pit Tables. Installation Instructions for

GRLP4 CONVERSION KiT APPLiCATiON instructions

ASSEMBLY GUIDE. Customer Service: INCH² 2-BURNER & 864 INCH² 2-BURNER

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

A WARNING A IMPORTANT INSTALLATION AND OPERATION INSTRUCTIONS

G45 STAINLESS STEEL BURNER FOR OUTDOOR USE ONLY

SPK3E - Manual EASY Control

Brooks Fire Pit Table. Installation Instructions for Brooks Fire Pit Table BRK-1224

REPLACEMENT PROCEDURE: ROTISSERIE ORIFICE: TOOLS REQUIRED TO INSTALL THIS KIT: ITEM DESCRIPTION: E C

Stonefire Fire Pit Table. Installation Instructions for SF-32-K

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

The Wave. Installation Instructions for WV-56 Table

Sierra Linear Fire Pit Table. Installation Instructions for Sierra Fire Pit Table

ASSEMBLY GUIDE. Customer Service: INCH² 3-BURNER & 545 INCH² 3-BURNER

G45-GL STAINLESS STEEL BURNER FOR OUTDOOR USE ONLY

Pine Ridge Fire Pit Table. Installation Instructions for Pine Ridge fire pit models PR-1242-K and PR-2424-K

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

G45 STAINLESS STEEL BURNER FOR OUTDOOR USE ONLY

Installer: Leave This Manual with Consumer Consumer: Save this Manual for Future Reference

r e - p a r t s. c o m

Cleaning Fireside Franklin Pilot Orifice

Alcott Fire Table. Installation Instructions for ALC-1224

EMPIRE Comfort Systems

Instructions for Converting Range Top to Operate on Liquefied Petroleum Gas

Fire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A

Getting Started Guide

Operator's Manual. Model: RY10MK-PRO MPN: RA-MLT Gallon Direct Fire Melter Kettle Burner Model with Adjustable Flame-Out Valve

G45-GL SERIES VENTED GAS BURNER SYSTEMS (UNREGULATED)

RMC1E - Variable Flame Height EASY Control

OW LEE CASUAL FIRESIDE Q&A

INSTALLATION & OPERATING INSTRUCTIONS FOR. FIREPLACE GAS LOGS Model Numbers: MO18NG, MO24NG, SH18NG, SH24NG, CSO30NG

G45 STAINLESS STEEL BURNER FOR OUTDOOR USE ONLY

INSTALLATION & OPERATION MANUAL MADISON SPLIT FIREPLACE GAS LOG

FPPK-UN Control Kit Installation & Operating Instructions (Pan and Burner not included)

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

ML-47 TWIG SET INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Gas Go Anywhere /23/01

OW LEE CASUAL FIRESIDE Q&A

The Vintage Fire Pit Table

280 Propane Barbecue Assembly Manual

Uptown Fire Pit Table

The Cove Fire Pit. Installation Instructions for CV-30

INSTALLATION AND OPERATION GUIDE FOR

GRLP3 CONVERSION KiT APPLiCATiON instructions

Installation Guide. Single-Control Kitchen Sink Faucets

Maintenance 45 Serie CAUTION. Before resetting your electronic card that displays an error code.

August 10, 2011 PART # 27FP-MAN

G45 SERIES VENTED GAS LOG SETS (UNREGULATED)

t420 Barbecue Assembly Manual

G4-Stainless Steel Burner For Outdoor Use Only

PB SERIES VENTED GAS BURNER SYSTEMS (UNREGULATED)

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G)

LOG SET IMPORTANT INFORMATION

ER36D Range. IMPORTANT: This model is not approved for field conversions from one gas type to another and from one altitude setting to another.

Boardwalk Fire Pit Table

18" Convert to Gel Log Set # 2610

CAUTION...WARNING...IMPORTANT

Transcription:

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together. Refer to the Installation and Operating Instructions for proper gas supply, safety requirements and operating instructions TC30 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS PART# TC30.NG05C FOR TC30 Series C 180411.-16 TC30.NG05C 5056.42906

Contents of Package BURNER ASSEMBLY (including pilot and manifold) LOG GRATE TC30 HEARTWOOD LOGS EMBER MATERIAL HARDWARE PACKAGE AIR DEFLECTOR COAL CHUNKS VERMICULITE Burner Installation If this fireplace is to be used on Propane please convert prior to installtion. See pages 10 12. 1. Place the keyhole slots in the burner over the two screws located in the fi rebox base. (Fig. #1 & 1a) 2. Slide the burner back to engage the screws in the small part of the keyhole slot and tighten screws. (Fig. #1b) 3. Remove access cover from side of fi rebox(fig. #1c) Fig. # 1 Fig. # 1a Fig. # 1b SCREWS Fig. # 1c 2

Burner/ Grate Installation 4. Secure the electrical bulkhead plate and gasket to the fi rebox. (2 screws) Attach the ignition and sensor wires to the module. Red end to the connector marked by the red dot, white end to the connector marked by the white dot Fig.#2 & Fig.#3 Fig. # 2 2 SCREWS BULKHEAD PLATE Fig. # 3 WHITE END TO WHITE DOT MODULE RED END TO RED DOT 3

5. Attach the pilot and gas supply tubes to the bulk head fitting and tighten. (Fig. # 3b) Ensure the connections are gas tight. Conceal the spark and sensor wires below the supply tubes. Fig. # 3b A panel set must now be installed. See Installation and Operating Instructions manual for details. PILOT SUPPLY TUBE MAIN GAS SUPPLY TUBE 6. Position the slots of the grate securing brackets over the holes in the floor shield and secure with the two screws (Fig. # 4). Fig. # 4 4

Ember Material A large bag of ember material is shipped with the fi replace and needs to be installed on the burner to ensure optimum performance and flame appearance. A bag of coal chunks and lava rock is also supplied this must only be used around the burner pan to cover up the gas lines and brackets. 1. Pull apart the material into ember size pieces (approximately 1 square) and gently place them into the burner pan. Do not compress, leave them loose for best performance. 2. Fill the burner pan with embers until level with the top of the pan at rear, and gradually slope forward to the fi rebox floor at the front, covering both burner tubes. Note: Ember material placement and amount will affect flame appearance. 3. Place remaining ember material, coal chunks and lava rock outside of the burner pan as desired to cover-up gas lines and brackets. Do not put coal chunks or lava rock inside burner pan as this will cause sooting and the burner to malfunction. Fig. #5 More ember material results in lower flame height. Add or remove as needed until desired flame affect. Reduce the amount used on Propane models, as too much will create soot Embers only in this area. Fig. #6 Embers, coal chunks and lava rock. 5

Log Placement Gas plumbing and vent connections should be completed before proceeding. Fig. # 7 The logs are fragile, and should be handled with care. Unpack and inspect log set. There should be a total of seven logs. Position the logs as indicated by the following pictures. The seven main logs have holes and / or pins. Engage each pin in the corresponding holes. The remaining two logs do not have holes or pins. They rest in position. Locate as per the diagrams (fi g. # 7-15) BASE LOG, #1 Note: Improper placement of logs will cause sooting on internal parts and glass. The logs may need to be repositioned slightly to avoid excessive flame impingement. Fig. # 8 LEFT CENTER LOG, #2 6

Fig. #9 LEFT FRONT LOG, #3 Fig. #10 LOG WITH HOLE, #4 7

Fig. #11 RIGHT CENTER LOG, #5 Fig. #12 FRONT RIGHT LOG, #6 8

Fig. #13 RIGHT BASE LOG, #7 Fig. #14 CENTER TWIG, #8 Fig. #15 CENTER BASE CHUNK, #9 9

If the unit is to be used on propane, convert as follows using the components supplied with this fireplace: Note: Factory supplied components must be used to ensure correct input. After conversion confi rm proper manifold pressure. Propane Conversion MINIMUM RATE SCREW (5005.011) CAUTION The gas supply and electrical power must be shut off before proceeding with the conversion. WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction. 1. Ensure the burner, pilot and gas supply are turned off, and the appliance has cooled. 2. Remove the two screws securing the manifold assembly to the burner. (Fig. #16) Fig. # 16 MAIN BURNER (#48) ORIFICE (5021.3407) If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. 3. Remove the manifold assembly from the burner. (Fig. #17) Fig. # 17 The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer's instructions supplied with the kit. 4. With a ½ wrench remove the natural gas orifi ce (#32) and replace with propane orifi ce (#48) (our part # 5021.3407) (Fig. #18) 5. Fully open the primary air shutter. 6. Reinstall the manifold assembly and air deflector. Fig. # 18 10

M ra Fig. # 19 7. With a 7/16 wrench loosen the pilot head on the pilot assembly by a half-turn (Fig. #19) Fig. # 20 8. Slide the pilot adjustment band over and ensure that the hole in the orifi ce band is showing. (Fig. #20 shows NG position, Fig. # 21 shows LP position) Fig. #21 Adjustment Band HOLE Fig. # 22 9. Remove the minimum rate screw located in the valve. (Fig. #22) Minimum rate screw 11

10. Replace the minimum rate screw with the one provided in the propane conversion kit supplied with this fi replace. Ensure that the screw is fully installed. (Fig. #23) Fig #23 Minimum rate screw ADD DATE ADD NAME 11. Remove the aluminum cap from the top of the pressure regulator. (Fig. #24) Fig #24 12. Press down on the center post and rotate 90. The center post should stay down. (Fig. #25). Replace the alumnum cap. Fig #25 NG LP 13. Fill in the date and the name of the person who performed the conversion in the white area on the conversion label. Peel off the protective backing and apply the conversion label directly over the gas specifi cations on the rating label. 14. Attach the access panel to the side of the fi rebox with the previously removed screws. (Fig. #26) Fig #26 Note: Gasket must be installed with access panel. 12

Gas Pressure Check Note: To test the gas pressure, turn off the gas supply before removing the plug from the supply pressure test port or manifold pressure test port. Verify gas pressures with the fireplace lit and on the highest setting. SUPPLY MANIFOLD Fig #27 1. Remove the plug from the manifold test port. The plug is located between the right side lintel and fi rebox side (bottom port). (Fig. # 27) Fig #28 2. Thread the extension test fitting into the open test port. (Fig. #28) 3. Attach a pressure gauge onto the fitting. 4. When testing is complete remove the extension test fitting and replace the plug. Thread sealant will be required to ensure a gas-tight connection. Correct gas pressure requirement: Supply Pressure Natural Gas Propane (For purpose of input adjustment) Minimum 5.0" WC 12.5" WC Maximum 13.9" WC 13.9" WC Manifold Pressure Maximum 3.8" WC 11.0w" WC Minimum 2.1" WC 5.5" WC 13

Flame Adjustment The air shutter on the burner tube controls the primary combustion air to the gas burner and is preset at the factory for natural gas fuel. Some adjustment may be necessary to obtain desired flame and to eliminate carbon deposits. Evaluate flame appearance after the fi replace has reached operating temperature. See Fig. #29 for proper flame pattern. Open primary air shutter if the logs, glass, and fi rebox have carbon accumulation and / or the flames are long, dark and stringy. The shutter may also be opened to enhance the Ember Material glow and lessen the flame height. Caution: Burner area may be hot! Turn off the fi replace and allow the unit to cool before proceeding. Caution: Proper air shutter setting is a must. The flame should be just orange and lazy. It should NEVER be set to create sooting on internal parts and glass. Fig. # 29 To Adjust: 1. Open and remove window frame and set aside. See "Window Frame Removal" section found in the Installation and Operating Instructions manual. 2. Remove the log set and set aside. 3. Loosen the screw in the Primary Air Shutter. 4. Rotate the shutter to increase or decrease the amount of primary air. Fully closed for natural gas and fully open for propane gas. Fig. # 30 5. Reassemble in reverse order. PRIMARY AIR SHUTTER 14

Replacement Parts (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM...DESCRIPTION...PART NO. #1...TC30.NG05 BURNER ASSEMBLY... TC30.NG05C #2...9 PCS LOG SET.....5098.746131 #3...ORIFICE, NATURAL GAS (#32)...5021.332A * ITEM...DESCRIPTION...PART NO. #4...PILOT ASSEMBLY...TCRP.5005025 #5...MAIN SUPPLY TUBE (FLEX)......5019.223 #6...PROPANE CONVERSION KIT... TC30.LPCE01 #1 * NOT SHOWN 1d #2 #3 3 2 4 1 8 5 7 6 1c 1e 1f 1g 9 1b 1h #4 1a #5 KIT CONTENTS: #1... BURNER ASSEMBLY 1a GRATE 1b BURNER INSULATION 1c BURNER TRAY SUPPORT SHIELD 1d PILOT SHIELD 1e TC36.NG01 BURNER WELD 1f MANIFOLD 1g 1/2 PIPE TO 1/2 TUBE CONNECTION 1h PILOT BRACKET 2a BASE LOG (a) 2b LEFT CENTER LOG (b) 2c LEFT FRONT LOG (c) 2d LOG WITH HOLE (d) 2e RIGHT CENTER LOG (e) 2f FRONT RIGHT LOG (f) 2g RIGHT BASE LOG (g) 2h CENTER TWIG (h) 2i CENTER BASE CHUNK (i) - 3 ORIFICE, NATURAL GAS 4 PILOT ASSEMBLY 5 MAIN SUPPLY TUBE 6 PILOT TUBE #2... 9 PCS LOG SET EMBER MATERIAL (Not shown) 1 BASE LOG 2 LEFT CENTER LOG 3 LEFT FRONT LOG 4 LOG WITH HOLE 5 RIGHT CENTER LOG 6 FRONT RIGHT LOG 7 RIGHT BASE LOG 8 CENTER TWIG 9 CENTER BASE CHUNK #3... ORIFICE, NATURAL GAS (#32 15

TECHNICAL SUPPORT: 1-250-748-1184 www.townandcountryfireplaces.net 2975 Allenby Rd., Duncan, BC V9L 6V8 Printed in Canada