Confirmation Protocol for E. coli O157:H7

Similar documents
An Independent Laboratory Evaluation of the Invisible Sentinel Veriflow E. coli O157:H7 PCR Assay for the Detection of Escherichia coli O157:H7

Pr oject Summar y. Survey of the prevalence of Escherichia coli O157:H7 on the surface of subprimal cuts of beef during winter months (Phase I)

Project Summary. Principal Investigators: Chance Brooks, Mindy Brashears, Mark Miller, Alejandro Echeverry, and Cassandra Chancey

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Pathatrix E. coli O157:H7 Kit (Individual Samples) Linked to Selective Agar Plates

- Make sure the anaerobic tent will be available on the days you plan to use it. - Make sure the autoclave/incubator will be available.

Evaluation copy. Fecal Coliform. Computer INTRODUCTION

Core practical 13: Isolate an individual species from a mixed culture of bacteria using streak plating

VALIDATION OF DRY-AGING AS AN EFFECTIVE INTERVENTION STEP AGAINST ESCHERICHIA COLI O157:H7

Pathatrix 5-Pooling Dual E. coli O157:H7/ Salmonella Kit Linked to Selective Agar Plates

Coliform Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Coliform Count Plate

Gently apply pressure on spreader to distribute over circular area. Do not twist or slide the spreader. Interpretation

Innovative New Products

Petrifilm. Interpretation Guide. Coliform Count Plate. Brand

Interpretation Guide

Interpretation Guide

Made of polypropylene

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV

HSCC. Interpretation Guide. High-Sensitivity Coliform Count Plate

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE CC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

Interpretation Guide. Coliform Count Plate

1250ul Extra Long Pipet Tips (Sterile, Non-Filtered) in 6 hinged racks $18.50

high performance pipettors Excellence and precision for all your liquid handling procedures.

Titan3 Syringe Filters. Sample Preparation 1-036

Validation study according to the ISO standard: Synthesis. ISO validation of the BAX Real-Time

Pr oject Summar y. Impact of ground beef packaging systems and temperature abuse on the safety of ground beef

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE EC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

Kit Information 3. Sample Preparation 4. Procedure 4. Analysis of Results 5. Quality Control 6. Disposal 6. Technical Support 6. Order Information 6

REC. Interpretation Guide. Rapid E. coli/coliform Count Plate

Investigation of the effect of antibiotics on bacterial growth. Introduction. Apparatus. Diagram of Apparatus

Operating Instructions

Project Summary. Principal Investigators: Lawrence D. Goodridge 1 ; Phil Crandall 2, and Steven Ricke 2. Study Completed 2010

3M TM Petrifilm TM. Petrifilm TM 3M TM. 3M TM Petrifilm TM Serie 2000 Rapid Coliform Count Plates - Ref.: / 50 Unit - Ref.

Food Microbiological Examination: Enumeration of Coliforms

Capacity (ml) Ø (mm) Height (mm) Cap Packed Pk Cat. No Blue cap bulk V White cap bulk V 125

Kit Information 4 Introduction. 4 Kit Contents, Storage, and Testing Conditions. 4 Equipment Needed. 4 Applicability. 4 Precautions... 4.

Influence of Freezing and Freezing plus Acidic Calcium Sulfate Addition on Thermal Inactivation of Escherichia coli O157:H7 in Ground Beef

California Leafy Greens Research Board Final Report April 1, 2008 to March 31, 2009

Vivaspin 500, 2, 6 and 20

Proficiency Testing. Food Microbiology. January Laurence Nachin, Christina Normark and Irina Boriak

COLIFORM BROTH. Fecal Coliform Broth. M-FC BROTH without ROSOLIC ACID (Blue background)

Laboratory Line. Perfectly Equipped for Every Challenge. CoreLab DX. Laboratory Equipment

Interpretation Guide 3M Petrifilm Rapid Coliform Count Plates

TRANSFER PIPETS. transfer of liquids. Designed for the safe and convenient. transfer of liquids. Includes 52 NEW sterile pipets!

Genomics Research Consumables

Carbon and Water Program Protocols for Neutrally Buoyant Sediment Traps Twilight Zone Explorer at BATS, June 2007-December 2009

JOURNAL OF CLINICAL MICROBIOLOGY, Jan. 2000, p Vol. 38, No. 1. Copyright 2000, American Society for Microbiology. All Rights Reserved.

Urine Analysis. Solutions for sample collection

Operating Instructions

Convenient Media Solutions For food and water testing

Learning Styles: Visual, auditory, kinesthetic, and synthesis

Comparison of the Novel ColiPlate

Big SHOT III Hybridization Oven

Access 2 Immunoassay System Supplies

container specs crack resistant

Chromocult Coliform Agar acc. ISO

HARLECO Dyes & Stains Microscopy products to support your success

"We understand when you mean quality"

AQIS MEAT NOTICE. Last Notice this Category

THE DURAN LABORATORY BOTTLE SYSTEM

General Laborator. Beakers, Low Form. Beakers, Low Form. Beaker Cups, Disposable Consumables General Plasticware

Awesome Autumn Sale on our most popular products!

Administration of Micafungin Using Minibag Plus & DIAL-A-FLO

Instructions for Use: Duodenoscope Sampling Kit

Fisher Scientific is exclusively offering the Thermo Scientific Lab Rewards program.

Comparison of Gelman and Millipore Membrane Filters for Enumerating Fecal Coliform Bacteria

Cell Culture Research Consumables

Jonathan Howarth Ph.D and Tina Rodrigues BS Enviro Tech Chemical Services Modesto, CA 95258

NNIN Nanotechnology Education

HARLECO Dyes & Stains Microscopy products to support your success

Productivity. Technician. Maximized. Interpretation Guide

Tacta Mechanical Pipettes Perfectly Balanced

Community College of Philadelphia. Department of Chemistry

ORDERING INFORMATION SRK SWAB-RINSE KIT ENVIRONMENTAL SWAB SYSTEMS. copangroup.com

Cultures, Specimen Collection for

#6 Spill and Accident Procedures

Making Solar Cells 1 from Household Materials (mostly :)

Visit LABSCO.com for more information on our complete clinical lab portfolio! Designed to meet the exacting standards of healthcare professionals

SECTIONING PROCEDURE FOR LASER CAPTURE MICRODISSECTION

Laboratory Safety. A practical approach.

Results of a longitudinal study of the prevalence of Escherichia coli O157:H7 on cow-calf farms

TUBING PLEASE READ. Tubing for Samplers with Peristaltic Pumps

LBH18BPK. Instruction Sheet

Tubes and Containers (Plastic)

BEAKERS MEASURING JUGS FISHER CLAMP FISHER CLAMP ANALYTICAL FUNNELNALYTICAL FUNNEL

How to Use Your Implanted Venous Port

Diamond RealSeal Plastic Laboratory Bottles

Proven quality and selection with unparalleled support.

Pr oject Summar y. Colonization characteristics of bovine recto-anal junction tissues by Escherichia coli O157:H7

BOTTLE CAPS & CONNECTION SYSTEMS

Your cells deserve the best

Lab Equipment. Chemistry Willowridge High School Mr. L Moore

AUTOMATED MEDIA PREPARATION

BOTTLE CAPS & CONNECTION SYSTEMS

QUOTATION REQUEST FORM

Mixing Your Alpha-1 Therapy Aralast NP

How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g.

Spill Control. Choice Quality Affordability

9 LABORATORY ACCESSORY

Transcription:

Introduction Confirmation Protocol for E. coli O157:H7 The following protocol is used by Hygiena to recover E. coli O157:H7 from beef samples that were enriched according to the BAX System method. The protocol is taken from the USDA-FSIS and Dyna Beads Product Information page for analyzing raw and ready-to-eat meat products. https://www.fsis.usda.gov/wps/wcm/connect/51507fdb-dded-47f7-862d-ad80c3ee1738/mlg- 5.pdf?MOD=AJPERES and https://www.thermofisher.com/order/catalog/product/71003?sid=srchsrp-71003 Many culture methods begin with a highly selective enrichment broth to promote growth of E. coli O157:H7 and suppress competing background flora. Because the BAX system amplifies only those DNA fragments that are unique to E. coli O157:H7, it is not distracted by competing flora and can reliably detect the target in less time and with less selective enrichment. This difference in enrichments, however, can make it difficult to confirm positive BAX system results with traditional culture methods, especially when the sample contains low levels of E. coli O157:H7. Various other factors over which the BAX system has no control can also affect confirmation results. Low levels of E. coli O157:H7 in a sample may be lost during refrigeration of the enrichment. Amplicon contamination in a lab might yield an initial positive result that does not confirm. Electrical noise, mislabeling and other errors can sometimes yield a non-confirmable positive result. Although this confirmation protocol should be effective for most samples, some particularly difficult samples may require additional steps. Contact technical support (800-863-6842) for more information. Equipment and Supplies Incubators, static (36 C (+/-1 C) and 42 C (+/-1 C)) Micropipettors to deliver 15-1000 µl with sterile disposable filtered micropipette tips Mechanical pipettor with 1.0 ml, 5.0 ml, 10.0 ml sterile pipettes Inoculating loops, hockey sticks or spreaders Vortexer (Vortex-Genie 2 #G560 or equivalent) UV lamp (366 nm) (Merck #1.13203.0001 or equivalent). Sterile disposable 12 x 75 mm polypropylene tubes (e.g. Fisher # 14-956-1B)

Microcentrifuge and sterile 1.5 ml microcentrifuge tubes Sterile 50 ml conical tubes (e.g. Falcon # 2070) or sterile bottles Sterile 40 µm Cell Strainer (Falcon # 2340) MACS Large Cell Separation Columns (Miltenyi Biotec # 422-02) OctoMACS Separation Magnet (Miltenyi Biotec # 421-09) Multistand to support OctoMACS Separation Magnet (Miltenyi Biotec # 423-03) Tray, autoclavable, approximately 130 mm x 83 mm (e.g. VWR # 62663-222) for use with the OctoMACS Media, Reagents and Cultures Modified Tryptone Soya Broth (mtsb) Modified Tryptone Soya Broth with Novobiocin (mtsb+n) Modified Rainbow Agar (mrba) [Rainbow Agar O157 Biolog Inc., Hayward California, 94545] containing 5.0 mg/l novobiocin, 0.05 mg/l cefixime trihydrate and 0.15 mg/l potassium tellurite Tryptic soy agar with 5% sheep blood (SBA) SOB + A Medium E Buffer, approximately 7 ml per sample (Buffered Peptone Water, Bovine Albumin Sigma # A7906-500G and Tween-20 ) Disinfectant (Lysol I. C., 2.0%) Dynal # 710.04 anti-e. coli O157 antibody-coated paramagnetic beads (Dynal Inc., Lake Success, NY 11042) E. coli O157:H7 strain 465-97 (positive control used throughout method) E. coli ATCC strain 25922 (optional negative control for the latex agglutination assay) Selective agars (Rainbow Agar O157 [Biolog Inc., Hayward California, 94545] containing 10 mg/l novobiocin plus 0.8 mg/l potassium tellurite, CT-SMAC agar or equivalent). Note: Since not all E. coli O157:H7 are tellurite-resistant, it is important to include other selective plating media, such as Cefixime and Rhamnose supplemented Sorbitol MacConkey agar (CR-SMAC) (Oxoid Inc., Ontario, Canada) or Fluorocult E. coli O157:H7 Agar (Merck KgaA, Darmstadt, Germany). Cefsulodin (Sigma #C8145)

Blood agar - Tryptic soy agar with 5% sheep blood. Dynabeads anti-e. coli O157:H7 antibody-coated paramagnetic beads (Thermo Fisher Scientific # 71003-50 tests or #71004-250 tests) E. coli O157:H7 latex agglutination test kit (REMEL RIM E. coli O157:H7 Latex Test Kit or equivalent). Procedure Note: Store the stock vial of Dynabeads at 2-8ºC, but make sure that the reagents and sample enrichments are pre-warmed to room temperature (>18ºC) before use to ensure optimal recovery. Note: Steps a.- i. may be performed in a sequence that is convenient to the laboratory personnel. a. Prepare E Buffer by mixing 0.5 g Bovine Albumin and 50 µl Tween-20 into 100 ml Buffered Peptone Water (BPW). Filter sterilize (0.2 µm) and store at 2-8 C. b. Remove mrba plates from 2-8 C storage, allowing 4 plates for each screen-positive culture and each control, with the exception of 2 plates for the fluorescent E. coli O157:H7 control. Be sure that plates have no visible surface moisture at the time of use. If necessary, dry plates (e.g. for up to 30 minutes in a laminar flow hood with the lids removed) prior to use. Dried plates that are not used should be labeled "dried", placed in bags and returned to 2-8 C. c. Remove a bottle of E Buffer from 2-8 C storage. Decant 7 ml of E Buffer for each culture and each control into a sterile tube or bottle and allow it to warm to at least 18oC. (Return the stock E Buffer to 2-8 C.) d. For each positive control and screen-positive culture to be analyzed, keep in order and label 50 ml conical centrifuge tubes so that the positive control is first, followed by all cultures. Maintain this order for subsequent steps. e. For each positive control and screen-positive culture, label two sterile 1.5 ml microcentrifuge tubes (for step g and step t), one 50 ml conical centrifuge tube and four 12 x 75 mm capped tubes (one for step p). For each set of 12 x 75 mm tubes, label one tube and add 0.9 ml E Buffer to three of the four tubes (step q). f. Prepare the Dynal #710.04 E. coli O157:H7 immunomagnetic bead suspension by

following Table 1 below. Be sure to include the positive control in the total number of cultures. Use the bead suspension immediately (step g), or hold at 2-8 C. Return the stock vial of Dynal #710.04 E. coli O157:H7 immunomagnetic beads to 2-8 C. g. Vortex the bead solution briefly (2-3 seconds), then add 50 µl to a labeled microcentrifuge tube (from step e), one for the control and screen-positive culture. Use immediately or hold these tubes at 2-8 C. h. Place a 40 µm Cell Strainer on a labeled 50-ml conical centrifuge tube (from step e). Pipet 5 ± 1 ml of each control and enrichment culture into the respective Cell Strainer and collect at least 1.0 ml of filtrate. i. Do not proceed with more than the number of tubes that the OctoMACS magnet(s) will hold. Transfer 1.0 ml of a filtrate (step h) to the corresponding microcentrifuge tube containing the immunomagnetic bead suspension (step g) and place in the clips of the LabQuake tube agitator. Rotate the tubes for 10-15 min at 18-30 C. j. Attach the OctoMACS Magnet to the Multistand. k. Position a tray on the base of the Multistand so that it will collect the filtrate passing through the columns. Add approximately 300 ml of 2% Lyso l disinfectant to cover the bottom of the tray. l. Label and place the appropriate number of Large Cell Separation columns on the OctoMACS Magnet. Insert columns from the front making sure the column tips do not touch any surfaces. Leave the plungers in the bags at this time to maintain sterility. m. Transfer at least 0.5 ml E Buffer to the top of each column and let the buffer run through. n. Resuspend, then transfer each culture and control from step i. to its corresponding column. o. After a culture or control has drained through, wash the column by applying 1.0 ml of E Buffer to each column and allow to drain. Repeat 3 more times for a total of 4 washes. p. After the last wash has drained, remove the column from the OctoMACS Magnet

and insert the tip into an empty labeled 12 x 75 mm tube (from step e.). Apply 1.0 ml of E Buffer to the column, and using the plunger supplied with the column, immediately flush out the beads into the tube. Use a smooth, steady motion to avoid splattering. Cap the tubes. Repeat this for each column. If the OctoMACS magnet is to be used for a second set of cultures, it must be decontaminated as described in step u, below. Repeat steps j-s for the additional cultures. q. Make a 1:10 dilution of each treated bead suspension by adding 0.1 ml of the bead suspension to a 12 x 75 mm labeled tube containing 0.9 ml E-Buffer. Make a 1:100 dilution by adding 0.1 ml of the 1:10 dilution to a 12 x 75 mm labeled tube containing 0.9 ml E Buffer. r. Vortex briefly to maintain beads in suspension and plate 0.1 ml from each tube (1:10 dilution and 1:100 dilutions) onto a labeled mrba plates. Use a hockey stick or spreader to spread plate the beads, being careful not to spread the beads against the edge of the plate. s. As soon as there is no visible moisture on the agar surface, invert plates and incubate for 20-24 h at 35 ± 2 C. t. OPTIONAL Acid Treatment: For each sample, transfer 450 µl of the undiluted bead suspension (MACS column eluant) to an empty labeled microcentrifuge tube. Add 25 μl of 1N hydrochloric acid (HCl) to this bead suspension and vortex briefly. This will bring the ph to 2.0-2.5 using E-buffer. Note: The fluorescent E. coli O157:H7 control sample is excluded as it does not grow following acid treatment. u. Place the microcentrifuge tubes containing the acid treated suspension on a LabQuake Agitator and rotate tubes for 1 hour at 18-30 C temperature. v. After 1 hour, dilute the suspension by adding 475 μl of E-buffer. w. Vortex briefly to maintain beads in suspension and plate 0.1 ml of the neutralized suspension onto a labeled mrba plate. Use a hockey stick or spreader to spread plate the beads, being careful not to spread the beads against the edge of the plate. x. Add 0.1 ml of the suspension to a labeled tube containing 0.9 ml E-buffer and vortex briefly. This shall represent a 1:10 dilution of the acid-treated cell suspension. Plate

0.1 ml of the diluted suspension onto an appropriately labeled mrba plate. y. As soon as there is no visible moisture on the agar surface, invert plates and incubate for 20-24 h at 35 ± 2 C. z. Optional: Streak E. coli ATCC strain 25922 to TSA with 5% Sheep s Blood Agar for use as a latex negative control. aa.. Decontaminate the OctoMACS Magnet by applying 2% Lysol I. C. disinfectant directly to the surface. After approximately ten minutes, rinse with deionized or tap water. Allow the unit to air-dry or use absorbent paper towels to dry the unit.