Energy Name Ulrike Sachs Abteilung E D SE PTI SW Telefon 09131/7-33429 Fax 09131/7-33246 E-Mail ulrike.sachs@siemens.com Datum 2011-03-23 Invitation to the 4 th PSS SINCAL International User Meeting and PSS SINCAL Training Session. Dear PSS SINCAL User, After 9 very successful PSS SINCAL user group meetings for the German PSS SINCAL users and 3 successful PSS SINCAL international User Group meetings in Budapest, Berlin and Trondheim we invite you herewith to our 4 th PSS SINCAL International User Group Meeting The meeting will take place in from till Turkey, Istanbul Monday, May 30 th 2011, 2:00 p.m. Tuesday, May 31 st 2011, 4:00 p.m. The following items will surely be of interest for you: New Features / Techniques in PSS SINCAL Version 7.0 / 7.5 Protection Data Management System (PDMS) Distributed Generation and Smart Metering / Smart Grids /Micro Grids Wind Power Integration User Contributions We are thankful for further suggestions and appreciate if you would like to share your experience with us. During our first get-together on Monday at 2:00 p.m. among the introduction of all participants, we will discuss your expectations of the meeting, general items and, of course, the PSS SINCAL product development. As contribution towards expenses (participation fee) for this event we will charge 210, - Euro, excl. VAT. Please inform us as soon as possible, (e.g. sending us the Fax- Reply or Email), but by May 5 th 2011 at the latest, if you will attend the 4 th PSS SINCAL International User Group Meeting.
We will organize the following PSS SINCAL training if a minimum of 4 users register for the training. ************************************************************************************************************************ On Wednesday, June 01 st 2011 and Thursday, June 02 nd 2011 we are planning a PSS SINCAL Basic training session Attached please find the training contents. For this 2 days-training we will charge you 1200,-Euro, excl. VAT, including refreshments and lunch. ************************************************************************************************************************ On Friday, June 03 rd 2011 we are planning a PSS SINCAL Protection training session If the PSS SINCAL Basic training will not take place the PSS SINCAL Protection training can take place on Wednesday, June 01 st 2011. Attached please find the training contents. For this 1 day-training we will charge you 600,-Euro, excl. VAT, including refreshments and lunch. ************************************************************************************************************************ We will send you the invoice after we have received your participation confirmation. Please provide the invoice address (if it is different from your postal address) in the attached Fax-Reply-Form. Please register for the 4 th PSS SINCAL International User Group Meeting and /or the PSS SINCAL Training Session sending us the Fax- Reply or Email by May 5 th 2011 at the latest. We have reserved accommodation in Istanbul, Richmond Hotel Istanbul Address: Istiklal Cd. No:227 Tunel Beyoglu / Istanbul / Turkey Tel :+90 212 252 54 60-181 Fax:+90 212 252 97 07 Web:www.richmondhotels.com.tr E-mail: meltemp@richmondhotels.com.tr The price for a room (incl. breakfast) is 115,-Euro. Accommodation is not included in the participation fee. You are requested to book the hotel rooms by yourself. For the reservation of your room please send an email to meltemp@richmondhotels.com.tr Reservation code PSS SINCAL UGM. We are looking forward to meeting you at the 4 th PSS SINCAL International User Group Meeting in Istanbul! Best regards,
Fax-Reply 0049 9131 7 33246 or email to sonja.koleva@siemens.com Sender: Company... Address.. First name, name.. An: Siemens AG Power Technologies International Software Solutions Ulrike Sachs Tel.:... Fax: Email:.. Confirmation of Participation 4 th PSS SINCAL International User Group Meeting I will attend the 4 th PSS SINCAL International User Group Meeting on May 30 th 31 st 2011 I will attend the Meeting only on May 31 st 2011 Invoice address (if it is different from your postal address): Reference or order number:.. Confirmation of Participation PSS SINCAL BASIC Training or PSS SINCAL Protection Training I will attend the PSS SINCAL Basic Training on June 01 st 02 nd 2011 I will attend the PSS SINCAL Protection Training on June 03 rd 2011 I cannot attend the 4th PSS SINCAL International User Meeting Generally, I am interested in attending the PSS SINCAL International User Meeting I am not interested in attending the PSS SINCAL International User Meeting
Agenda 4 th PSS SINCAL International User Group Meeting May 30 th - 31 st 2011 Monday, May 30 th 2011 02:00 p.m. Welcome the participants of the first PSS SINCAL User Group Meeting. 02:15-02:45 p.m. Introduction of the participants and their expectations to the meeting, common PSS SINCAL items 02:45-04:45 p.m. New features in PSS SINCAL Version 7.0 (Part 1) 04:45 p.m. Common exchange of experiences Tuesday, May 31 st 2011 09:00-09:30 a.m. New features in PSS SINCAL Version 7.5 (Part 2) 09:30-10:00 a.m. PSS SINCAL applications in large scaled distribution networks (Mrs. Seher Günaltay, Mr. Bugra Akduman) 10:00-10:30 a.m. Composite feeder protection in HV networks (Mr. Göksun Virlan, Mr. Serkan Özkardeş) 10:30-10:45 a.m. Break 10:45-11:15 a.m. 11:15-11:45 a.m. Still open Distributed Generation - Meter reading 11:45 a.m. - 01:00 p.m. Lunch 01:00-02:00 p.m. New Developments and customer Wish List 02:00-02:30 p.m. Other user experiences / Discussion 02:30-03:45 p.m. Open Questions about PSS SINCAL 03:45-04:00 p.m. Closing of the 4 th PSS SINCAL User Group Meeting
PSS SINCAL Basic Course Training objectives The participants will acquire basic knowledge how to use the network planning program PSS SINCAL. They will learn to use the software for basic calculations on topics related to load flow and short-circuit. Main features Wednesday, June 01 st 2011 09:00 a.m. - 17:00 p.m. Introduction into PSS SINCAL User interface Data model and project handling in PSS SINCAL Network model, elements, libraries Graphic editor Data import/export, e.g. Excel Introductory example Creation of new project Data entry and result representation Display of background graphics (e.g. landbase) Power flow analysis Setting of input data of network elements and load flow calculation parameters Exercise Network planning tools Diagrams creation, e.g. voltage profile, feeder loading, display of load centers (hot spots) Multiple network views (e.g. both geographic and schematic network graphic) etc. Thursday, June 02 nd 2011 09:00 a.m. - 17:00 p.m. Short-circuit analysis and enhanced functions Short-circuit analysis Fundamentals of short-circuit analysis Setting of input data of network elements and shortcircuit current calculation parameters Exercise Enhanced functions Spreadsheet view of data and results Creation of user-defined libraries and element catalogs Variant management Smart data selection and manipulation Feeder and route detection Report generation etc. Exercise and discussion
PSS SINCAL Protection Suite Course Training objectives The participants will acquire basic knowledge of how to use the protective-relayingmodules in the network planning tool PSS SINCAL. They will learn to use the software for time overcurrent- as well as applications with distance protection. Main features Friday, June 03 rd 2011 09:00 a.m. - 17:00 p.m. PSS SINCAL Protection Suite Introduction Activation of protection functionalities in PSS SINCAL Inserting protection devices from protective device libraries Setting of general input data and calculation settings Overcurrent-time protection Selection and setting of overcurrent protection devices Overcurrent-time protection coordination Creation of grading path and I-t grading diagrams Creation of user-defined overcurrent protection devices and library Exercise Distance protection parameter calculation Selection and setting of distance protection relays Creation of R-X zone setting diagrams; X-t and Z-t grading diagrams Automatic grading of zone reaches and times using different algorithms Exercise comparing results of different grading algorithms and visualizing the effect of parallel lines and intermediate infeeds on zone reaches. Protection Simulation Combined simulation of overcurrent-time and distance protection devices Stepped-event fault simulation of faults and visualization of fault clearing sequence Tele-protection Fault location Batch simulation and identification of incorrect settings Documentation of input data and coordination results Exercises and discussion