600W with FC and arallel Function S-600 series MODEL:S-600-24 OUTUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 240 mvp-p (Max ) I/: 230VAC O/:FULL LOAD V1: 56 mvp-p (Max ) 2 OUTUT VOLTAGE CH1: 20V~ 26.4 V I/: 230 VAC 18.55 V~ 26.7 V/ 230 VAC ADJUST RANGE I/: 115 VAC O/:MIN LOAD 18.55 V~ 26.7 V/ 115 VAC 3 OUTUT VOLTAGE V1: 1 %~ -1 % (Max) I/: 155 VAC / 264 VAC V1: 0.12 %~ -0.12 % TOLERANCE O/:FULL/ MIN LOAD 4 LINE REGULATION V1: 0.5 %~ -0.5 % (Max) I/: 155VAC ~ 264 VAC O/:FULL LOAD V1: 0.03 %~ -0.03 % 5 LOAD REGULATION V1: 0.5 %~ -0.5 % (Max) I/: 230 VAC O/:FULL ~MIN LOAD V1: 0.12 %~ -0.12 % 6 SET U TIME 230VAC: 1500 ms (Max) I/: 230 VAC 230VAC/ 957 ms 115 VAC: 1500 ms (Max) I/: 115 VAC 115VAC/ 957 ms O/:FULL LOAD 7 RISE TIME 230VAC: 50 ms (Max) I/: 230 VAC 230VAC/ 3 ms 115VAC: 50 ms (Max) I/: 115 VAC 115VAC/ 3 ms O/:FULL LOAD 8 HOLD U TIME 230VAC: 16 ms (TY) I/: 230 VAC 230VAC/ 23 ms 115VAC: 16 ms(ty) I/: 115 VAC 115VAC/ 23 ms O/:FULL LOAD 9 OVER/UNDERSHOOT TEST < +5% I/: 230 VAC O/:FULL LOAD 10 DYNAMIC LOAD V1: 2400 mvp-p I/: 230 VAC O/:FULL /Min LOAD 90%DUTY/1KHZ TEST: <5 % 1717 mvp-p Model: S-600-24 Test Report 1 / 6
600W with FC and arallel Function S-600 series INUT FUNCTION TEST N O TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 INUT VOLTAGE RANGE 88VAC~264 VAC I/:TESTING O/:FULL LOAD I/: LOW-LINE-3V= 85 V HIGH-LINE+15%=300 V O/:FULL/MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF ) TEST: OK 67V~264V 2 INUT FREQUENCY RANGE 47HZ ~63 HZ OSC I/: 88 VAC ~ 264 VAC O/:FULL~MIN LOAD 3 OWER FACTOR 0.95 / 230 VAC(TY) I/: 230 VAC 4 EFFICIENCY 86% (TY) I/: 230 VAC TEST: OK F= 0.96 / 230 VAC 0.98 / 115 VAC (TY) I/: 115 VAC F= 0.99 / 115 VAC O/:FULL LOAD O/:FULL LOAD 5 INUT CURRENT 230V/ 4.1 A(TY) I/: 230 VAC 87.7 % I = 3.2 A/ 230 VAC 115V/ 8.2 A(TY) I/: 115 VAC I = 6.5 A/ 115 VAC O/:FULL LOAD 6 INRUSH CURRENT 230V/ 50 A (TY) I/: 230 VAC I = 28 A/ 230 VAC 115V/ 25 A(TY) I/: 115 VAC I = 15 A/ 115 VAC COLD START O/:FULL LOAD 7 LEAKAGE CURRENT < 1.5 ma / 240 VAC I/: 254 VAC O/:Min LOAD L-FG: 1 ma N-FG: 0.98 ma Model: S-600-24 Test Report 2 / 6
600W with FC and arallel Function S-600 series ROTECTION FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 OVER LOAD ROTECTION 105%~ 135 % I/: 230 VAC I/: 115 VAC O/:TESTING 122 %/ 230 VAC 122 %/ 115 VAC Constant current limiting 2 OVER VOLTAGE ROTECTION CH1: 27.6 V~ 32.4 V I/: 230 VAC I/: 115 VAC O/:MIN LOAD 29.6 V/ 230 VAC 29.6 V/ 115 VAC Shunt down Re- power ON 3 OVER TEMERATURE ROTECTION SEC: TSW1: 85+ 5 O.T. TSW2: 80+ 5 O.T. I/: 230 VAC O/:FULL LOAD O.T.. Active Shut down o/p voltage,recovers automatically after temperature goes down,than re-power on to recover 4 SHORT ROTECTION SHORT EVERY OUTUT 1 HOUR I/: 264 VAC O/:FULL LOAD Foldback Current Limiting CONTROL FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 FAN SEED CONTROL ------- I/: 230 VAC O/:FULL LOAD 2 REMOTE CONTROL Rc+ / Rc- SHORT OWER ON OEN OWER OFF I/: 230 VAC O/:FULL LOAD Fan Voltage= 10.8 V SHORT OWER ON OEN OWER OFF 3 OWER OK OWER ON : 3.3V~6V OWER OFF : 0V~2V I/: 230 VAC I/: 115 VAC O/:FULL LOAD 4 CURRENT SHARING SU1-SU2 < 10% I/: 230 VAC O/:FULL/50% LOAD 5 REMOTE SENSE >0.3V I/: 230 VAC O/:FULL LOAD OWER ON : 4.88 V OWER OFF : 0 V O/:100% SU1: 715 W SU2: 697 W O/:50% SU1: 355 W SU2: 354 W >0.3V Model: S-600-24 Test Report 3 / 6
600W with FC and arallel Function S-600 series ENVIRONMENT TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 TEMERATURE RISE TEST MODEL:S-600-24 1. ROOM AMBIENT BURN-IN:1 HRS I/: 230VAC O/: FULL LOAD Ta= 33.6 2. HIGH AMBIENT BURN-IN: 2 HRS I/: 230VAC O/: FULL LOAD Ta= 52.6 NO osition /N ROOM AMBIENT Ta= 33.6 HIGH AMBIENT Ta= 52.6 1 U1 ML480 49.1 69.0 2 C37 220U/25V NCC 105 KY 43.7 65.1 3 C6 150U/400V RUB 85 USC 35.1 54.9 4 D1 BYV10-600 10A/600V H 43.0 63.2 5 Q1 16N50C3 16A/500V INF 47.5 68.7 6 L1 TR-498 49.3 70.9 7 D9 BYM26E 2.3A/1KV 44.1 64.1 8 BD1 D15XB60 15A/600V SHI 46.1 75.7 9 TRC1 BTA16-600 16A ST 59.7 80.8 10 LF2 TR-436 39.6 59.9 11 Q52 K2850 6A/900V FUJI 68.2 93.9 12 Q53 K2850 6A/900V FUJI 69.1 98.7 13 D72 D9202 20A/200V FUJI 58.5 78.9 14 T1 COIL TF-1150 46.0 66.7 15 C208 680U/35V NIC 105 KY 35.3 55.6 2 OVER LOAD BURN-IN TEST 1 HOUR ( MIN ) 3 LOW TEMERATURE TURN ON AFTER 2 HOUR TURN ON TEST I/: 230 VAC O/: 111 % LOAD I/: 230 VAC O/: 100 % LOAD Ta= -20 4 HIGH HUMIDITY HIGH TEMERATURE HIGH VOLTAGE TURN ON TEST 5 TEMERATURE COEFFICIENT AFTER 12 HOURS IN CHAMBER ON CONTROL 45 I/: 272 VAC O/:FULL LOAD Ta= 45 HUMIDITY= 95 %R.H + 0.03 %(0~50 ) I/: 230 VAC O/:FULL LOAD 6 VIBRATION TEST 1 Carton & 1 Set Operating at I/: 230VAC NO LOAD (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) + 0.01 %(0~50 ) Model: S-600-24 Test Report 4 / 6
600W with FC and arallel Function S-600 series SAFETY TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 WITHSTAND VOLTAGE I/-O/: 3 KVAC/min I/-FG: 1.5 KVAC/min O/-FG: 0.5 KVAC/min I/-O/: 3.6 KVAC/min I/-FG: 1.8 KVAC/min O/-FG: 0.6 KVAC/min I/-O/: 6.51 ma I/-FG: 6.17 ma O/-FG: 3.82 ma 2 ISOLATION RESISTANCE I/-O/:500VDC>100MΩ I/-O/: 500 VDC I/-O/: 11 GΩ I/-FG: 500VDC>100MΩ O/-FG:500VDC>100MΩ I/-FG: 500 VDC O/-FG: 500 VDC I/-FG: 5 GΩ O/-FG: 8 GΩ 3 GROUNDING CONTINUITY FG(E) TO CHASSIS OR TRACE < 100 mω 40 A / 2min 8 mω 4 AROVAL TUV: Certificate NO :R50051249 UL: File NO :E183223 E.M.C TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 HARMONIC EN61000-3-2 CLASS A I/: 230 VAC/50HZ O/:FULL LOAD ASS 2 CONDUCTION EN55022 CLASS B I/: 230 VAC (50HZ) 3 RADIATION EN55022 CLASS B 4 E.S.D EN61000-4-2 LIGHT INDUSTRY AIR:8KV / Contact:4KV O/:FULL/50% LOAD I/: 230 VAC (50HZ) O/:FULL LOAD I/: 230 VAC/50HZ O/:FULL LOAD ASS Test by certified Lab ASS Test by certified Lab CRITERIA A 5 E.F.T EN61000-4-4 I/: 230 VAC/50HZ CRITERIA A LIGHT INDUSTRY INUT: 1KV O/:FULL LOAD 6 SURGE IEC61000-4-5 I/: 230 VAC/50HZ CRITERIA A LIGHT INDUSTRY L-N :1KV O/:FULL LOAD L,N-E:2KV 7 Test by certified Lab & Test Report repare Model: S-600-24 Test Report 5 / 6
600W with FC and arallel Function S-600 series M.T.B.F & LIFE CYCLE CALCULATION NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 CAACITOR LIFE CYCLE SUOSE C205 IS THE MOST CRITICAL COMONENT I/: 230VAC O/:FULL LOAD Ta= 25 LIFE TIME= 2220955 HRS I/: 230VAC O/:FULL LOAD Ta= 45 LIFE TIME= 655699 HRS 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 116.4K HRS COMONENT STRESS TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 ower Transistor ( D to S) or (C to E) eak Voltage 2 Diode eak Voltage D 72 Rated Q 52 Rated 2SK2850 : 900 V 6 A D9202 : 200V 20A 3 Clamp Diode eak Voltage D 50 Rated UF5408 3A/1KV 4 Input Capacitor Voltage C5 Rated :150 u / 400V/ 85 I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2) Full Load (3)Output Short I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2) Full Load (3)Output Short I/:High-Line +3V = 267 V O/: (1)Full Load (2) Dynamic Load 90%Duty/1KHz I/:High-Line +3V = 267 V O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 756 V (2) 776 V (3) 760 V (1) 73.2 V (2) 121 V (3) 121 V (1) 740 V (2) 756 V (1) 378 V (2) 372 V (3) 390 V 5 Control IC Voltage Test U50 Rated 3845 : 30V I/:High-Line +3V = 267 V O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 16 V (2) 14.7 V (3) 16.2 V DATE SAMLE TEST RESULT TESTER AROVAL 2004/8/13 RD SAMLE ASS VINCENT TSENG MAX LIN 2004/11/9 2005/1/5 RODUCT SAMLE W0409A42 RODUCT SAMLE W0411C25 ASS VINCENT TSENG MAX LIN ASS VINCENT TSENG MAX LIN 2003/12/12 A50-F023 Model: S-600-24 Test Report 6 / 6