20W Single Output Industrial DIN Rail Power Supply MODEL:MDR OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

Similar documents
120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

Test Report: HEP

15W Single Output Switching Power Supply MODEL:RS OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

600W with PFC and Parallel Function PSP-600 series

MODEL:RT-65B OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT I/P: 230 VAC O/P:FULL LOAD

20W Single Output Switching Power Supply MODEL:LPV OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT O/P:FULL LOAD

60W Single Output LED Power Supply MODEL:PLP OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

Test Report: EDR-75-12

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST

Test Report: EPS 15 12


1000W Intelligent Single Output Battery Charger MODEL:PB OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT.


Test Report: EPP

Test Report: HB

Test Report: EPP


Test Report: IRM-10-12

Test Report: IRM-05-24


Test Report: IRM-05-05

Test Report: IRM-20-24

60W Single Output Switching Power Supply

Test Report: APC

Jameco SKU Number:

Test Report: GSM40A18

320W Single Output with PFC Function

62.5W Rated output power for convection; 80W with 18CFM min. forced air

CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection

35W Single Output Switching Power Supply

60W Single Output Switching Power Supply

Engineering Design Assurance Test Report ( S )

240W Single Output with PFC Function

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Engineering Design Assurance Test Report ( S )

PB 300/360 P 12 PB PB V 28.8V 13.6V 27.2V 26 ~ 28.8V. 40 ~ 125Ah 10.5A 6.25A

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

LPS 20V 24V. COLD START 40A(t width=1030 s measured at 50% I peak) <0.75mA / 240VAC

Jameco SKU Number:

1000W Single Output Power Supply

60W Single Output LED Power Supply

50W Single Output Switching Power Supply

1000W Single Output Power Supply

IP65 IP67 MODEL CLG CLG CLG CLG CLG CLG CLG V 15 ~ 20V 24V 18 ~ 24V

75W Single Output with PFC Function

MODEL CEN CEN CEN CEN CEN CEN CEN V 24V 30V 36V 42V

Test Report: LCM 60DA









Model Number Structure

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

General-purpose Relay

Feature. Model comment JG 3NA B L - B - D3

Plug-in/solder terminals with LED indicator

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

General-Use Auto-Tuning HPX-T Series

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

General Purpose High Power PCB Relays

CPFE1000Fi-48 EVALUATION DATA TDK-LAMBDA

Model Number Structure

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

Electrical Specifications. Input range Vac (Operating) 115/230 Vac (Nominal) Internal fuse on both L and N lines.

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

DuroSite LED Floodlight - CE. for Outdoor Industrial Applications #

LM 80 Test Report NS2L157AR H3

Reliable high-power LED that gives you the design flexibility and performance you need

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

DEUTSCH H91 Series Filter Connectors MIL-DTL SERIES I

Product Guide LED OBSTRUCTION LIGHTS

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

Type CGS High-Cap Screw Terminal Aluminum Electrolytic Capacitor

AVIONICS MOUNTS Low Profile, All-Axis Vibration Isolators

SafeSite. Series LED Based Signaling for Hazardous Locations

Limit Switches. 6.2 E47 Precision Switches

Features Benefits Key Applications

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

DuroSite LED Floodlight - UL / CSA for Outdoor Industrial Applications

SafeSite LED Stainless Steel Linear - ATEX / IECEx for Indoor and Outdoor Industrial Applications

SPECIFICATION FOR LCD MODULE

SafeSite LED Floodlight - ATEX / IECEx. for Outdoor Industrial Applications. 1 MDTEXSSFLX001_B

Transcription:

20W Single Outut Industrial DIN Rail Power Suly MODEL:MDR-20-12 OUTPUT FUNCTION TEST 1 RIPPLE & NOISE V1: 120 mv- (Max ) I/P: 230VAC V1: 19 mv- (Max ) 2 OUTPUT VOLTAGE CH1: 10.8 V~ 13.2 V 10.21 V~ 13.85 V/ 230 VAC ADJUST RANGE O/P:MIN LOAD 10.21 V~ 13.85 V/ 115 VAC 3 OUTPUT VOLTAGE V1: 1 %~ -1 % (Max) I/P: 100 VAC / 264 VAC V1: 0.2 %~ -0.2 % TOLERANCE O/P:FULL/ MIN LOAD 4 LINE REGULATION V1: 1 %~ -1 % (Max) I/P: 100 VAC ~ 264 VAC V1: 0 %~ 0 % 5 LOAD REGULATION V1: 1 %~ -1 % (Max) O/P:FULL ~MIN LOAD V1: 0.15 %~ -0.15 % 6 SET UP TIME 230VAC: 115 VAC: 500 1000 (Max) (Max) 230VAC/ 115VAC/ 241 275 7 RISE TIME 230VAC: 30 (Max) 230VAC/ 7 115VAC: 30 (Max) 115VAC/ 6 8 HOLD UP TIME 230VAC: 115VAC: 50 20 (TYP) (TYP) 230VAC/ 115VAC/ 133 29 9 OVER/UNDERSHOOT TEST < +5% TEST: <5 % 10 DYNAMIC LOAD V1: 1200 mv- O/P:FULL /Min LOAD 90%DUTY/1KHZ 312 mv- Model: MDR-20-12 Test Reort 1 / 5

20W Single Outut Industrial DIN Rail Power Suly INPUT FUNCTION TEST 1 INPUT VOLTAGE RANGE 85VAC~264 VAC I/P:TESTING I/P: LOW-LINE-3V= 82 V HIGH-LINE+15%=300 V O/P:FULL/MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC POWER ON/OFF ) TEST: OK 46V~264V 2 INPUT FREQUENCY RANGE 47HZ ~63 HZ OSC I/P: 85 VAC ~ 264 VAC O/P:FULL~MIN LOAD 3 EFFICIENCY 80 % (TYP) 4 INPUT CURRENT 230V/ 0.35 A (TYP) TEST: OK 81.2% I = 0.25 A/ 230 VAC 115V/ 0.55 A (TYP) I = 0.38 A/ 115 VAC 5 INRUSH CURRENT 230V/ 40 A (TYP) I = 22 A/ 230 VAC 115V/ 20 A(TYP) I = 11 A/ 115 VAC COLD START 6 LEAKAGE CURRENT < 1 ma / 240 VAC I/P: 254 VAC PROTECTION FUNCTION TEST O/P:Min LOAD L-FG: 0.64 ma N-FG: 0.64 ma 1 OVER LOAD PROTECTION 105 %~ 160 % O/P:TESTING 128 %/ 230 VAC 127 %/ 115 VAC Constant Current Limiting 2 OVER VOLTAGE PROTECTION CH1: 13.8 V~ 16.2 V O/P:MIN LOAD 15.3 V/ 230 VAC 15.3 V/ 115 VAC Shunt down Re- ower ON 3 SHORT PROTECTION SHORT EVERY OUTPUT 1 HOUR I/P: 264 VAC Constant Current Limiting CONTROL FUNCTION TEST 1 NO LOAD POWER CON SUMPTION <0.75W O/P:NO LOAD 2 DC OK ACTIVE SIGNAL (max) 9V~13.5V / 40mA O/P: 40mA 230 VAC/ 0.71W 115 VAC/ 0.62W 230 VAC/ 11.93V 115 VAC/ 11.97V Model: MDR-20-12 Test Reort 2 / 5

20W Single Outut Industrial DIN Rail Power Suly ENVIRONMENT TEST 1 TEMPERATURE RISE TEST MODEL:MDR-20-24 1. ROOM AMBIENT BURN-IN:1.5HRS I/P: 230VAC O/P: FULL LOAD Ta= 31.4 2. HIGH AMBIENT BURN-IN:45HRS I/P: 230VAC O/P: FULL LOAD Ta= 44.6 NO Position P/N ROOM AMBIENT Ta= 31.4 HIGH AMBIENT Ta= 44.6 1 U1 NCP1200 ON 61.5 73.6 2 C5 33U/400V NCC 105 KMG 47.6 58.5 3 BD1 KBP208G 2A/800V LT 53.2 63.0 4 LF1 LF-562 JSI 49.7 66.0 5 D1 EGP20J 2A/600V ZOW 69.0 80.2 6 Q1 K3562 6A/600V TOS 74.6 87.0 7 ZD1 P6KE150A LT 63.3 73.4 8 D100 F20LC30 20A/300V SHI 82.0 92.6 9 C36 100U/35V RUB 105 YXF 60.9 72.7 10 C105 220U/35V RUB 105 ZLH 66.2 77.2 11 J100 型錳銅線 57.5 68.4 12 L100 DR-007D 61.6 72.5 13 D300 HER104 1A/300V REC 75.6 87.0 14 Q302 2SA1249-1.5A/-160V 76.2 86.8 2 OVER LOAD BURN-IN TEST 1 HOUR ( MIN ) 3 LOW TEMPERATURE TURN ON AFTER 2 HOUR TURN ON TEST O/P: 132 % LOAD O/P: 100 % LOAD Ta= -20 4 HIGH HUMIDITY HIGH TEMPERATURE HIGH VOLTAGE TURN ON TEST 5 TEMPERATURE COEFFICIENT AFTER 12 HOURS IN CHAMBER ON CONTROL 50 I/P: 272 VAC Ta= 50 HUMIDITY= 95 %R.H + 0.03 %(0~50 ) 6 VIBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Swee Time:10min/swee cycle (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) + 0.004 %(0~50 ) Model: MDR-20-12 Test Reort 3 / 5

20W Single Outut Industrial DIN Rail Power Suly SAFETY TEST 1 WITHSTAND VOLTAGE I/P-O/P: 3 KVAC/min I/P-FG: 1.5 KVAC/min O/P-FG: 0.5 KVAC/min I/P-O/P: 3.6 KVAC/min I/P-FG: 1.8 KVAC/min O/P-FG: 0.6 KVAC/min I/P-O/P: 3.9 ma I/P-FG: 4.46 ma O/P-FG: 2.08 ma 2 ISOLATION RESISTANCE I/P-O/P:500VDC>100MΩ I/P-O/P: 500 VDC I/P-O/P: 18 GΩ I/P-FG: 500VDC>100MΩ O/P-FG:500VDC>100MΩ I/P-FG: 500 VDC O/P-FG: 500 VDC I/P-FG: 9 GΩ O/P-FG: 30 GΩ 3 GROUNDING CONTINUITY FG(PE) TO CHASSIS OR TRACE < 100 mω 40 A / 2min 13 mω 4 APPROVAL TUV: Certificate NO :R50093954 UL: File NO :E215312 E.M.C TEST 1 HARMONIC EN61000-3-2 CLASS A /50HZ 2 CONDUCTION EN55022 EN55011 (50HZ) CLASS B O/P:FULL/50% LOAD Test by certified Lab 3 RADIATION EN55022 EN55011 (50HZ) CLASS B Test by certified Lab 4 E.S.D EN61000-4-2 /50HZ AIR:8KV / Contact:4KV 5 E.F.T EN61000-4-4 /50HZ INPUT: 1KV 6 SURGE IEC61000-4-5 /50HZ L-N :1KV L,N-PE:2KV 7 Test by certified Lab & Test Reort Preare M.T.B.F & LIFE CYCLE CALCULATION 1 CAPACITOR LIFE CYCLE MDR-20-24 : SUPPOSE C105 IS THE MOST CRITICAL COMPONENT I/P: 230VAC Ta= 25 LIFE TIME= 219673 HRS I/P: 230VAC Ta= 50 LIFE TIME= 45198 HRS 2 MTBF MIL-HDBK-217F NOTICES2 PARTS COUNT TOTAL FAILURE RATE: 236.9KHRS 3 DMTBF/Accelerated Life Test Demonstration Mean Time Between Failure : Above 30,000 hours @ TA 50 P Model: MDR-20-12 Test Reort 4 / 5

20W Single Outut Industrial DIN Rail Power Suly COMPONENT STRESS TEST 1 Power Transistor ( D to S) or (C to E) Peak Voltage Q1 Rated K3562 : 600V / 6 A 2 Diode Peak Voltage D100 Rated BYQ28X-200 : 200V/ 10 A 3 Clam Diode Peak Voltage D1 Rated EGP20J : 600V/ 2A O/P: (1)Full Load Turn on (2) Outut Short O/P: (1)Full Load Turn on (2)Outut Short O/P: (1) Dynamic Load 90%Duty/1KHz (1) 574 V (2) 580 V (1) 129 V (2) 108 VV (1) 550 V 4 Inut Caacitor Voltage C5 Rated :33u / 400V/ 105 O/P: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 382 V (2) 386 V (3) 386 V 5 Control IC Voltage Test U1 Rated NCP1200 : 16V O/P: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 12.7 V (2) 11 V (3) 11 V DATE SAMPLE TEST RESULT TESTER APPROVAL 2006/8/24 RD SAMPLE VINCENT TSENG MAX LIN 2006/10/3 2006/11/15 2007/1/11 W0609B03 W0611A07 W0612C10 VINCENT TSENG MAX LIN VINCENT TSENG MAX LIN VINCENT TSENG MAX LIN 2003/12/12 A50-F023 Model: MDR-20-12 Test Reort 5 / 5