SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

Similar documents
630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

Model Number Structure

SLP. Contents. SLP Ordering Details... 12/2 Technical Data... 12/5 12/1 1SBC R1001

LOCAL DISCONNECT SWITCHES Manual Motor Controllers

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

General Purpose High Power PCB Relays

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

Switch Disconnector Fuse, SR A. SlimLine

General-purpose Relay

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Surge-Trap Pluggable STPT12 Series kA

FastLine. Contents. FastLine Description... 14/2 Ordering Details... 14/3 Technical Data... 14/7 14/1 1SBC R1001

Safety Interlock Switches

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Surge-Trap Pluggable STPT2 Series - 40kA

Plug-in/solder terminals with LED indicator

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Grounding Clamp. Pins and Ball-Socket Clamps for Temporary Grounding

Emergency Stop Devices

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

QK-CE220RL V02 230V. CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR PLUG & PLAY. 433,92 MHz

ABB Kabeldon. Laboratory Report. Mechanical test of Service Distribution Cabinets, SDC and SDCM

Electronic Temperature Controls

a Nexans company Catalogue 2009

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

EPM Series Reversing Electric Actuators

NK Multi-stage submersible pumps

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

Trapped Key Transfer System SHGV SVM SVE

Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)

SPEDESTER Series QUICK REFERENCE GUIDE

Conservatory awning W8 Description

General-Use Auto-Tuning HPX-T Series

Air Handlers BCS3. Warranty Parts - 5 Year Limited. 1.5 to 5 Tons. Suitable for use with R-22 and R-410A refrigerants

Special Three-Phase Motors with HSK-C Tool Holder for Manual Quick Tool Change

Feature. Model comment JG 3NA B L - B - D3

Table Legs & Extensions 7.1

HEATER POWER CONTROLLER

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

USER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999)

Introduction 2. Other Applicable Documents 2. Scope of Delivery 3. Attaching the Snap-on Ferrite Suppressor 4

CASM electric cylinders The modular electric cylinder system

E2 Motors and Motor Starting. #1 Fan Motors

S&S POWER SWITCHGEAR. Founded by N S Sethuramon and A R Shanthanakrishnan way back in 1978

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES

Limit Switches. 6.2 E47 Precision Switches

FIBER OPTIC CLOSURES

ELITE Series R-410A - Upflow / Horizontal - High Efficiency Blower Motor

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL

RCS750 3-circuit square track system flexible and multifunctional

AFA TS GmbH - Werner von Siemens Str.3 - D Grafenberg Copyright 2009 Tel.: +49(0) Fax: +49(0)

SECTIONAL OVERHEAD DOORS

Data Sheet for Precision Potentiometer

SWL Series VALVE REGULATED LEAD-ACID BATTERIES SWL

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

Product Guide LED OBSTRUCTION LIGHTS

BERNSTEIN TOOLS FOR ELECTRONIC

CASM electric cylinders

TENDABOX BX3000. Cassette awning with folding arms BX3000. Description. Options:

Blister Packing Machine

Data Sheet for Precision Potentiometer

Model Crosspoint Matrix

DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions

Cementex Products Inc. 650 Jacksonville Rd. P.O. Box 1533 Burlington, NJ

SUBMITTAL DATA SHEET SINGLE PACKAGE HEAT PUMP UNITS 6-1/2 THROUGH 12-1/2 TONS MODELS: XP COOLING PERFORMANCE HEATING PERFORMANCE

Model Number Structure

ELECTRICAL PROPERTIES PVC FILLER NOMINAL VOLTAGE 0,6/1 kv CLOURS CORES CLOURS

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

Installation instruction


ELITE SERIES R-410A Ready - Multi-Position

Elan Schaltelemente GmbH & Co. KG. SHGV safety. Catalogue SHGV

Smallest Connector with Removable Contacts

quick and easy installation guide

FERRULES & TOOLS Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

User manual for awning blind AMZ Z-Wave

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

TRUMPF TRUMATIC L 3050

Safety and process lock Knox

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

Insulated Scissors. Handles made with shock-proof plastic. Length Blade Std. Part No. Type mm shape Pk.

Double C-Face Spring-Set Brakes

SafeSite. Series LED Based Signaling for Hazardous Locations

SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: ZH/ZJ/ZR , ZF

Induction Motors. Standard AC Motors. Constant Speed Motors. Standard AC Motors C-19. Induction Motors

Selection Guide EQUIPMENT FOR OVERHEAD LINES

Russellstoll. Electrical Interconnection Systems. Dura-Gard Nonmetallic Waterproof Connections. The Next Generation: Dura-Gard

TECHNICAL INFORMATION

Installation Instructions

MINIPOL SYSTEM Hot moulded GRP

Transcription:

Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution sdmat_048_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved safety Function SIDERMAT combination are manually operated tri- or tetrapolar fuse disconnecting switches which can be triggered remotely. They make and break under load conditions and provide safety isolation and protection against overcurrent for any low voltage electrical circuit. Advantages Tripping upon overload. Remote breaking by voltage release device. High breaking capacity Protection against overloads and shortcircuits thanks to high breaking capacity fuses (100 ka rms). They can automatically switch on a power circuit in combination with: - fuse blown indication, - thermal relay, - differential relay, - protective relays DIRIS, - other protective devices. Improved safety Double break per phase. Visible break. Positive break indication. IP2X protection with terminal shrouds front panel. A complete range > Can be combined with ur fuses for the protection of power semi-conductors. Please consult us. Conformity to standards > IEC 60947-3 > EN 60947-3 > BS EN 60947-3 > NBN EN 60947-3 > IEC 60269-1 > IS 14947-3 > DIN EN 60269-1 > NF EN 60269-1 > IEC 60269-2 > VDE 0636-1 > VDE 0660-107 316 General Catalogue 2017-2018

References NFC and DIN - Front operation - Switch body with a shunt trip coil - 230 VAC Rating (A) / Fuse (4) No. of poles Switch body Direct handle External handle Shaft for external handle 1 st position AC Tripping AC Terminal shrouds top Terminal screens top Inter phase barrier 630 A / 3 3 P 3520 3063 3998 3063 4 P 3520 6063 3998 4063 800 A / 4 3 P 3520 3080 4 P 3520 6080 1250 A / 4 1600 A / 2 x 4* 1800 A / 2 x 4* 3 P 3520 3120 4 P 3520 6120 3 P 3520 3160 3 P + NC 3520 4160 4 P 3520 6160 Black 3999 6203 (1) S3 type Black IP55 1431 3511 (1) Red IP55 1432 3511 320 mm 1401 1532 1 st contact NO/NC 3999 0051 2 nd contact NO/NC 3999 0052 1 contact NO/NC 3999 0031 3 P 2998 3120 (2) 4 P 2998 4120 (2) 3 P 3520 3180 (3) 2998 3180 (2) 3 P + NC 3520 4180 (3) included 4 P 3520 6180 (3) 2998 4180 (2) 3 P 2998 0003 4 P 2998 0004 (1) Standard. (2) Bottom terminals protection screen as standard. (3) Only one of the two T4 fuses should be equipped with striker. (4) For the fuses: see "NFC-DIN industrial fuselinks 0.16 to 1250 A" page 344. * Two size 4 DIN fuses in parallel per pole. General Catalogue 2017-2018 317

Accessories Direct front operation handle Rating (A) Handle colour Reference 630 1800 Black 3999 6203 630 1800 Red consult us acces_156_a_2_cat External front operation handle Rating (A) Handle colour External IP Reference 630 1800 Black IP55 1431 3511 630 1800 Red IP55 1432 3511 acces_151_a_2_cat acces_166_a_2_cat S3 type handle Alternative S-type handle cover colours For single lever S3 type handles. Other colours: consult us. Colour To be ordered by multiple Reference Light grey 50 1401 0001 Dark grey 50 1401 0011 acces_198_a_2_cat Shaft for external handle Standard lengths: - 200 mm, - 320 mm. Other lengths: consult us. acces_144_b_1_cat Rating (A) Dimension X (mm) Shaft length (mm) Reference 630 800 350 450 200 1401 1520 630 800 350 570 320 1401 1532 1250 1800 370 570 320 1401 1532 X acces_202_a_1_x_cat Current-reducing resistor for undervoltage trip coil Reduces, by limiting the current, the effects on the undervoltage coils used in continuous processes or processes exposed to high ambient temperatures. Voltage Reference 110 VAC 3999 3112 230 VAC 3999 3230 400 VAC 3999 3400 110 VDC 3999 4110 318 General Catalogue 2017-2018

Alternative tripping coils Coils Characteristics: see "SIDERMAT" page 304. Shunt trip coil Replacement tripping coil Original coil (1) Voltage Reference Reference 24 VAC 3990 1024 3991 1024 48 VAC 3990 1048 3991 1048 110 VAC 3990 1110 3991 1110 230 VAC 3990 1220 included 400 VAC 3990 1380 3991 1380 12 VDC 3990 2012 3991 2012 24 VDC 3990 2024 3991 2024 48 VDC 3990 2048 3991 2048 110 / 200 VDC 3990 2220 3991 2220 Undervoltage trip coil Replacement tripping coil Original coil (1) Voltage Reference Reference 24 VAC 3990 3024 3991 3024 48 VAC 3990 3048 3991 3048 110 VAC 3990 3110 3991 3110 230 VAC 3990 3220 3991 3220 400 VAC 3990 3380 3991 3380 12 VDC 3990 4012 3991 4012 24 VDC 3990 4024 3991 4024 48 VDC 3990 4048 3991 4048 110 VDC 3990 4110 3991 4110 220 VDC 3990 4220 3991 4220 (1) To be ordered at same time as switch (factory fitted). Shunt trip coil. Undervoltage trip coil Omnipolar breaking remotely controlled by shunt trip or undervoltage voltage release coil. Note: the shunt trip coil must not be supplied for more than 5 s. A 230 VAC shunt trip coil is fitted to the standard switch body. To modify this coil, the reference opposite must be added to the switch reference (use "original coil" reference). Examples for ordering Combined SIDERMAT with shunt trip coil 230 VAC - 1 reference: Combined SIDERMAT 630 A, 3 pole, front operation: 3520 3063. Combined SIDERMAT fitted with a non standard coil - 2 references: Combined SIDERMAT 630 A, 3 pole, front operation fitted with a 110 VAC undervoltage trip coil: 3520 3063 + 3991 3110. acces_049_a_1_cat acces_050_a_1_cat Auxiliary contacts References NO/NC position contact Rating (A) Position AC Reference 630 1800 1 st 3999 0051 630 1800 2 nd 3999 0052 NO/NC low level position contact Rating (A) Position AC Reference 630 1800 1 st 3999 0111 630 1800 2 nd 3999 0112 NO/NC contact, signalling coil tripping Rating (A) Position AC Reference 630 1800 1 3999 0031 Pre-break and signalling of positions and I: 1 to 2 NO/NC auxiliary contacts acces_048_a_1_cat Characteristics NO/NC position contact Operating current I e (A) Current nominal 250 VAC 400 VAC 24 VDC 48 VDC Rating (A) (A) AC-13 AC-13 DC-13 DC-13 630 1800 16 12 8 14 6 NO/NC contact, signalling coil tripping Operating current I e (A) Current nominal 250 VAC 400 VAC 24 VDC 48 VDC Rating (A) (A) AC-13 AC-13 DC-13 DC-13 630 1800 16 12 8 12 2 Coil tripping 1 to 2 NO/NC auxiliary contacts Connection to the control circuit By 6.35 mm fast-on terminal. Characteristics NO/NC auxiliary contact: IP2. Electrical characteristics 30 000 operations. General Catalogue 2017-2018 319

Accessories (continued) Fuse blown indication For DIN fuse cartridges with striker. Electrical principle A NO/ NC auxiliary contacts detects that the fuse has blown. Connection to the control circuit By 6.35 mm fast-on terminal. Electrical characteristics 30 000 operations. NO/NC changeover contact Rating (A) No. of poles Position AC Reference 630 1800 3/4 P 1 st included Characteristics Operating current I e (A) Nominal 250 VAC 400 VAC 24 VDC 48 VDC Rating (A) current (A) AC-13 AC-13 DC-13 DC-13 630 1800 16 12 8 12 2 Terminal shrouds Top or bottom protection against direct contact with terminals or connection parts. Advantages Perforations allowing remote thermographic inspection without removal. Rating (A) No. of poles Position Reference 630 3 P top 3998 3063 630 4 P top 3998 4063 acces_212_a_2_cat Terminal screens Top or bottom protection against direct contact with terminals or connection parts. Rating (A) No. of poles Position Reference 800 1600 3 P top 2998 3120 800 1600 4 P top 2998 4120 1800 3 P top 2998 3180 1800 4 P top 2998 4180 800 1800 3/4 P bottom included Inter phase barrier Safety isolation between the terminals, essential for use at 690 VAC or in a polluted or dusty atmosphere. Rating (A) No. of poles Reference 1250 1800 3 P 2998 0003 1250 1800 4 P 2998 0004 acces_036_a_1_cat Handle key interlocking accessories Locking in position 0 of the front operation handle: - using a padlock (not supplied) and the factory integrated padlocking function of the handle. - using RONIS 1104 A lock (key BC 3318) to be mounted directly on the padlockable handle, - locking using RONIS EL11AP lock (not supplied). Locking using RONIS EL 1104 A lock (supplied) Rating (A) Operation Reference 630 1800 front direct 3999 8104 Locking using RONIS EL11AP lock (not supplied) Rating (A) Operation Reference 630 1250 front direct 3999 7007 1600 1800 front direct 3999 6117 630 1800 external front 1499 7701 Lock RONIS 1104A acces_010_b_1_x_cat Other specific accessories Customised protection screens (for specific dimensions or high ambiant temperatures). Connection accessories. Mounting plates for standard systems. Special construction available for specific environments. 320 General Catalogue 2017-2018

Characteristics according to IEC 60947-3 630 to 1800 A Thermal current I th (40 C) 630 A 800 A 1250 A 1600 A 1800 A Fuse size 3 4 4 2 x 4 2 x 4 Rated insulation voltage U i (V) 1000 1000 1000 1000 1000 Rated impulse withstand voltage U imp (kv) 12 12 12 12 12 Rated operational currents Ie (A) Rated voltage Utilisation category A/B (1) A/B (1) A/B (1) A/B (1) A/B (1) 400 VAC AC-22 A / AC-22 B 630/630 800/800 1250/1250 1600/1600 1600/1800 400 VAC AC-23 A / AC-23 B 630/630 630/630 1250/1250 1600/1600 1600/1600 690 VAC (2) AC-21 A / AC-21 B 630/630 800/800 1250/1250 1600/1600 690 VAC (2) AC-22 A / AC-22 B 500/630 630/800 1000/1000 1250/1250 690 VAC (2) AC-23 A / AC-23 B 400/500 500/500 800/800 1000/1000 220 VDC DC-21 A / DC-21 B 630/630 800/800 1250/1250 1600/1600 220 VDC DC-22 A / DC-22 B 630/630 800/800 1250/1250 1600/1600 220 VDC DC-23 A / DC-23 B 500/630 630/800 1250/1250 1250/1250 440 VDC DC-20 A / DC-20 B 630/630 800/800 1250/1250 1600/1600 440 VDC DC-21 A / DC-21 B 630/630 800/800 1250/1250 1600/1600 440 VDC DC-22 A / DC-22 B 630/630 (3) 800/800 (3) 1250/1250 (4) 1600/1600 (4) 440 VDC DC-23 A / DC-23 B 500/630 (3) 630/800 (3) 1250/1250 (4) 1250/1250 (4) Motor power output (kw) At 400 VAC without pre-break in AC-23 (1)(5) 355/355 355/355 710/710 900/900 900/900 At 690 VAC without pre-break in AC-23 (1)(5) 400/475 475/475 750/750 900/900 At 400 VAC without pre-break in AC (1)(5) 355/355 450/450 710/710 900/900 900/900 At 690 VAC without pre-break in AC (1)(5) 475/600 600/750 900/900 1100/1100 Reactive power (kvar) At 400 VAC (5) 290 365 575 Fuse protected short-circuit withstand (ka rms prospective) Prospective short-circuit (ka rms) (6) 100 100 100 120 120 Associated fuse rating (A) (6) 630 800 1250 2 x 800 2 x 900 Short-circuit capacity Rated peak withstand current (ka peak) (6) 55 80 100 120 120 Connection Minimum Cu cable section (mm 2 ) 2 x 150 2 x 185 4 x 240 Minimum Cu busbar section (mm 2 ) 2 x 30 x 5 2 x 40 x 5 2 x 60 x 5 2 x 80 x 5 Maximum Cu cable section (mm 2 ) 2 x 300 2 x 300 4 x 185 6 x 240 8 x 240 Maximum Cu busbar width (mm) 50 63 100 100 100 Tightening torque min (Nm) 20 20 40 Mechanical characteristics Durability (number of operating cycles) 5000 5000 5000 3000 3000 Weight of 3 P switch (kg) 20 25 27 54 59 Weight of 4 P switch (kg) 24 30 32 70 75 (1) Category with index A = frequent operation - Category with index B = infrequent operation. (2) With terminal shrouds or phase barrier. (3) Poles cannot be juxtaposed. (4) 4-pole device with 2 pole in series by polarity. (5) The power value is given for information only, the current values vary from one manufacturer to another. (6) For a rated operational voltage Ue = 400 VAC. General Catalogue 2017-2018 321

Dimensions SIDERMAT combination 630 A Direct front operation 4 ø 10 3p: 507-4p: 587 3p: 365.5-4p: 445.5 83 60 111 327 1 1. Terminal shrouds top. 2. Terminal screens bottom 515 8 665 60 15 175 ø 13 80 80 73.5 114 3p: 307-4p: 387 2 190 sdmat_006_c_1_x_cat SIDERMAT combination 800 to 1250 A Direct front operation 4 ø 10 3p: 584.5-4p: 704.5 3p: 440.5-4p: 560.5 100.5 75 145 322 1 1. Terminal screens top 2. Terminal screens bottom 585 765 190 165 8 120 120 91 3p: 382-4p: 502 15 75 109 2 sdmat_005_a_1_x_cat SIDERMAT combination 1600 A Direct front operation 4 ø 11 3p: 588-4p: 708 3p: 443-4p: 563 100.5 158 432 1 1. Terminal screens top 2. Terminal screens bottom 748 778 190 240 8 120 120 91 3p: 382-4p: 502 38 118 2 sdmat_013_a_1_x_cat 322 General Catalogue 2017-2018

SIDERMAT combination 1800 A Direct front operation 4 ø 11 3p: 588-4p: 708 3p: 443-4p: 563 100.5 160 432 1 1. Terminal screens top 2. Terminal screens bottom sdmat_014_e_1_x_cat 748 8 120 120 91 3p: 382-4p: 502 778 38 240 118 2 190 Connection terminals SIDERMAT combination - 630 A SIDERMAT combination 800 to 1250 A sdmat_052_a_1_x_cat ø 19 x 11 30 33 50 ø 15 30 33 10 sider_074_a_1_x_cat 16 x 11 19 25 19 63 17 25 SIDERMAT combination 1600 to 1800 A - bottom SIDERMAT combination 1600 A - top SIDERMAT combination 1800 A - top sdmat_054_a_1_x_cat ø 13 40 90 20 40 sdmat_055_a_1_x_cat ø 13 80 40 20 40 sdmat_059_a_1_x_cat ø 13 100 50 20 40 General Catalogue 2017-2018 323