Landsnet. Five years of synchrophasor use in the control center. NASPI Work Group Meeting February 2013, Huntington Beach, CA

Similar documents
Attachment F1 Technical Justification - Applicability WECC-0107 Power System Stabilizer VAR-501-WECC-3

VAR-501-WECC-3 Power System Stabilizer. A. Introduction

A. Introduction Title: Power System Stabilizer (PSS) 2. Number: VAR 501 WECC

A Practical Power System Stabilizer Tuning Method and its Verification in Field Test

A. Introduction Title: Power System Stabilizer (PSS)

SOME NSW SYSTEM PLANNING ISSUES. Dr Col Parker Manager/System Planning & Analysis

Gain-Scheduled Control of Blade Loads in a Wind Turbine-Generator System by Individual Blade Pitch Manipulation

Validation Results of Airport Total Operations Planner Prototype CLOU. FAA/EUROCONTROL ATM Seminar 2007 Andreas Pick, DLR

Criteria for a Successful Shore Power Project

The Southern African Power Pool. Meeting growing power demands through Southern African regional integration

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Engineering Design Assurance Test Report ( S )

Power Network Control by HVDC in Japan

Load-following capabilities of Nuclear Power Plants. Erik Nonbøl

East African Power Industry Convention 2007, Addis Ababa, ETHIOPIA

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Aircraft Design: A Systems Engineering Approach, M. Sadraey, Wiley, 2012 Chapter 12 Design of Control Surfaces. Tables

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Airspace Complexity Measurement: An Air Traffic Control Simulation Analysis

WÄRTSILÄ HYBRID SOLUTIONS

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

15W Single Output Switching Power Supply MODEL:RS OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

MODEL:RT-65B OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT I/P: 230 VAC O/P:FULL LOAD

Power System Stabilizer(PSS) Design Using ANFIS Algorithm and Comparing the Results with conventional and fuzzy PSS

Supplementary airfield projects assessment

The Electric Power System

Shanghai Green Port Construction. Shanghai Municipal Transportation Commission

C/L TIMER v4.x _

Implementation Status & Results Djibouti Djibouti Power Access and Diversification Project (P086379)

Test Report: HEP

DYNAMIC AIRBORNE REROUTE PROGRAM (DARP) APPLICATION IN BUSINESS AVIATION

Space Based ADS-B. ICAO SAT meeting - June 2016 AIREON LLC PROPRIETARY INFORMATION

Reforms in Kosovo s power System

Transmission Investment Programme

Pumped storage hydroelectric power plants: Issues and applications BIH Case Study

Planning Resilient Transmission Networks in Chile

2017 Digital Grid Customer Summit Session Abstracts

City of Reykjavík Data center locations. March 2018 Department of Economic Development City of Reykjavik

Load-following capabilities of nuclear power plants

Implementation Status & Results Djibouti Djibouti Power Access and Diversification Project (P086379)

Advances for Pipelines

PORT MORESBY POWER PROJECT - UPDATE PNG Mining & Petroleum Investment Conference. 4 th December 2018

Test Report: APC

62.5W Rated output power for convection; 80W with 18CFM min. forced air

Performance Review Body 18

Solutions for infrastructure and power transfer in hybrid operated vessels

Western Area Power Administration Sierra Nevada Region. Annual Ten-Year Transmission Plan Assessment Report

Smart Networks Smart Islands. Nikos Chatziargyriou Chairman and CEO

J.M.Alveirinho Dias * R. Gonzalez * Ó. Ferreira * * Universidade do Algarve Faculdade de Ciências do Mar e do Ambiente

20W Single Output Industrial DIN Rail Power Supply MODEL:MDR OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

MONTHLY REPORT Issue No. R02-18 February 2018

P ROTECT JUST ABOUT E VERYTHING

Benefits of Integrating into a Regional Power Pool

Feature. Model comment JG 3NA B L - B - D3

Packed to perfection. FAST, FUNCTIONAL AND FLEXIBLE For industrial self-generation, small utilities, industrial and IPP customers who do not

Ship Owner Expectations

Performance Analysis of Space-Based ADS-B

DRIVING PROFITABLE GROWTH. BJÖRN ROSENGREN President & CEO


Test Report: EPP

Test Report: EDR-75-12

Atlantic Interoperability Initiative to Reduce Emissions AIRE

Black Start Ancillary Service Schedule

Integrating Life-Cycle Solutions for Maximum Return on Investment

Performance of Wind Farms in Thailand

Measurement of environmental benefits from the implementation of operational improvements

CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection

EA-12 Coupled Harmonic Oscillators



DEVELOPMENT. Challenges and Opportunities. 9/5/2008 eapic 2008 Nairobi 1

20W Single Output Switching Power Supply MODEL:LPV OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT O/P:FULL LOAD

Wind Energy in South-east Europe: Seminar III: WIND ENERGY PROJECT DEVELOPMENT. Mostar,

TfL Planning. 1. Question 1

Garrecht TRX 1500 Traffic-Sensor

Test Report: GSM40A18

Towards a 100% renewable energy future: WÄRTSILÄ Energy Solutions

Standardization of Shore connection Systems

Safety insulation transformers for SmartPower controller family

Pumped Storage Schemes & imported hydroelectricity

Trapped Key Transfer System SHGV SVM SVE

Test Report: HB

WÄRTSILÄ HY. Wärtsilä 29 May 2018 WÄRTSILÄ HY

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST

120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

Tradition and innovation

Congestion. Vikrant Vaze Prof. Cynthia Barnhart. Department of Civil and Environmental Engineering Massachusetts Institute of Technology

Helicopter Vector IFR

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

Test Report: EPP

DETERMINATION OF SOUND POWER LEVELS OF A TRANSFORMER AND A REACTOR

Large Disturbances During 2014 in Power System of Serbia

Test Report: IRM-20-24

United States Aircraft Certification Standards and Guidance on ADS-B

EXPERIMENTAL ANALYSIS OF THE INTEGRATION OF MIXED SURVEILLANCE FREQUENCY INTO OCEANIC ATC OPERATIONS

1000W Intelligent Single Output Battery Charger MODEL:PB OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT.

Distinctive Characteristics

Required Navigation Performance (RNP) in the United States

Transcription:

Landsnet Five years of synchrophasor use in the control center NASPI Work Group Meeting February 2013, Huntington Beach, CA Ragnar Guðmannsson System Operation

Overview 1. The Icelandic Transmission System and challenges in System Operation 2. WAMS in Landsnet s control room 3. WACS project s 4. Results and future development

Location of Iceland with distances over the Atlantic Ocean

Generation and Consumption

Generation Capacity 2006 0,5% 1,5% 4% 10% 0,5% MW 2.500 9% 0,5% 13% 6% 55% Transmission lines 220 kv 132 kv 66 kv 33 kv Substation 2.000 1.500 1.000 500 0 Geothermal Hydro

Generation Capacity 2012 7% 3% 30% MW 2.500 2.000 7% 14% 36% 4% Transmisson lines 220 kv 132 kv 66 kv 33 kv Substation 1.500 1.000 500 0 Geothermal Hydro

WAMS and tuning of PSS to improve stability in relation to commissioning of 690 MW generation and load in 2007 KR2 FLJ/KAR G G G G G G KRA 60 MW KR2 FL2 B A BLA 150 MW KAR 690 MW SI4 B ARE A PMU PSS Data center Auxiliary load 25 MW Potline 535 MW

Now 12 PMUs installed, with detail of Eastern 220kV AC system (DC to follow) for co-ordinating control KR2 FLJ/KAR G G G G G G KRA 60 MW KR2 FL2 B A BLA 150 MW KAR 690 MW SI4 B ARE A PMU PSS Data center Auxiliary load 25 MW Potline 535 MW

WAMS in Landsnet s control room Psymetrix - PhasorPoint RT monitoring of system stability PMU installation 2013 ARE, HRY, BUR, BUD, KLA PMU installation 2014 REY, ISA Data center is located at Landsnet control center Gylfaflöt Krafla Blanda Brennimelur Hrauneyjafoss Fljótsdalur Sigalda PMU location Data Centre 220kV 132kV 66kV

WAMS in Landsnet s control room WAMS - PhasorPoint EMS Tetra

WAMS in Landsnet s control room

WAMS Operator view Normal operating condition High resolution measurment [Hz, MW, kv, MVAR] - observation window 15 min (was 1-2 hr) - oscillation not seen by conventional EMS - damping, frequency bands (new) Maintenance Security assessment - predefined graph for better monitoring of system conditions Open 132 kv ring - interarea mode (0,3 to 0,5 Hz) - variation af production and influence on damping - better view of angle condition when closeing

WAMS Operator reponse Critical events or operating condition Opening of 132 kv ring (inter area mode) Trip of smelter load ( large proportion of total load) Trip of generation (at high transport between areas) Operator training EMS training simulator (3 days in 6 months interval) WAMS Known Issus Predefined actions Operator response Active power control of Hydro units GOV - AGC PSO Voltage control units, capacitor banks System spilt to prevent power ocillations Reduction of smelter load

WAMS trip of line on 132 kv ring PSO opens bustie CB at BLA Trip of FL2 open 132 kv ring FL2 CB closed at FLJ trip again

WAMS trip and reconnection of 132 kv ring Trip of SI4 open 132 kv ring System protection split at BLA 132 kv ring connected at HOL 132 kv ring closed at BLA

WAMS PSS tuning and system tests PSS off in KRA PSS on in KRA

WAMS PSS tuning and long-term tests 1.2Hz Mode 0.8Hz Mode Mode Amplitude (MW) Before PSS tuning After PSS tuning Mode Amplitude (MW) Mode Decay Time Constant (sec) Mode Decay Time Constant (sec)

WAMS PSS testing at HRA Unit without PSS and above normal operating limits [70 MW] 17,5 MW Test during PSS commisioning to check PSS damping performance

WAMS - KR2 out production changes Brennimelur FLJ Sigalda

WACS Project overview Psymetrix Wide Area Defence Scheme started 2011 Power balance of areas Prevent system split Increased system security Secondary Load Shedding started 2013 Increased power flow on 132 kv ring Faster shedding after system split More focus on lower voltage levels (smart grid) Increased system security PMU PDC Tetra modem trip of load

WACS - dynamics related to 132 kv ring BL2 A frequency SV frequency SI4 Load 132kV ring power flow Production area

WACS - Trip of 500 MW smelter load in SouthWest Active Power 132 kv ring Active Power 132 kv ring to KAR/ARE Frequency Voltage angle between FLJ and SIG

WACS - Wide Area Defence Scheme

WADS - Wide Area Defence Scheme Emergency control to maintain system stability seen as grid service, similar to underfrequency load shed targeted, controlled action to reduce overall impact Uses measurements from PhasorPoint - frequency, voltage angle Trips generation in an area where a large proportion of load has tripped Proportionate response to angle stability condition Increased system security with connected system

Results Knowledge of system dynamics has increased PSO s response time shorter and more affective Improved capability to analyse disturbances Important for testing and monitoring of regulation equipment GOV, AVR, PSS Knowledge of system dynamics has increased Stability has significantly increased with successful PSS tuning

Future : Improved damping PSS tuning of all hydro and geothermal units SVC POD commissioning and tunning Tunning of smelter load regulation equipment

Future : Governor design and tuning New governor design for Geothermal Island operation Geothermal units in AGC for emergency control Optimal settings for Hydro units in island operation to deal with smelter load variation after long outage

Future : WACS and smart grid solutions Emergency control of smelter load to reduce impact of disturbances Control of all secondary load from EMS and WACS (0-120 s) Intelligent system design to ensure secure system split depending on operating conditions