This protocol is designed for the isolation of 96 plasmid DNA samples from 1.3ml bacterial cultures. Yield is up to 6µg.

Similar documents
Operating Instructions

Big SHOT III Hybridization Oven

Operating Instructions

Access 2 Immunoassay System Supplies

Quick Start Guide 3500 AquaVent

Innovative New Products

UNODOS + / FLOCDOS +

Laboratory Line. Perfectly Equipped for Every Challenge. CoreLab DX. Laboratory Equipment

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE

9 LABORATORY ACCESSORY

Evaluation copy. Fecal Coliform. Computer INTRODUCTION

RV 10 Rotary Evaporators

high performance pipettors Excellence and precision for all your liquid handling procedures.

Corning Aspirator Instruction Manual

PSS Integrating 3 rd Party Intelligent Terminal. Application Note. Date December 15, 2009 Document number PSS5000/APNO/804680/00

PRL364NLG 36-INCH GAS PRO GRAND RANGE WITH GRILL (LP) PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

- Make sure the anaerobic tent will be available on the days you plan to use it. - Make sure the autoclave/incubator will be available.

Troubleshooting Guide

PRD366JGU 36-INCH DUAL-FUEL PRO GRAND RANGE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

SKYWELL 5T Quick Start User Guide

3M TM Petrifilm TM. Petrifilm TM 3M TM. 3M TM Petrifilm TM Serie 2000 Rapid Coliform Count Plates - Ref.: / 50 Unit - Ref.

MYOB EXO OnTheGo. Release Notes 1.2

High Speed Centrifuge. LHS-A, B Series

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G)

Configuring a Secure Access etrust SiteMinder Server Instance (NSM Procedure)

Kit Information 4 Introduction. 4 Kit Contents, Storage, and Testing Conditions. 4 Equipment Needed. 4 Applicability. 4 Precautions... 4.

Table of Contents. Part I Introduction 3 Part II Installation 3. Part III How to Distribute It 3 Part IV Office 2007 &

AND EFFICIENCY. Typical 18 L (3 trays*) round chamber. A lot of space is wasted. 15 L (5 trays*) rectangular chamber utilizing the maximum volume.

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4

Petrifilm. Interpretation Guide. Coliform Count Plate. Brand

CASS & Airline User Manual

Lab Equipment. Chemistry Willowridge High School Mr. L Moore

Coliform Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Coliform Count Plate

Gently apply pressure on spreader to distribute over circular area. Do not twist or slide the spreader. Interpretation

General-Use Auto-Tuning HPX-T Series

THE WARMTH OF WOOD, THE ECONOMY OF PELLETS INNOVATION, TECHNOLOGY, SAVINGS FAIR SRL ITALIAN MADE PELLET STOVES BIO STOVE ADVANTAGES THE PELLET

PRG366JG 36-INCH GAS PRO GRAND RANGE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

1224 Splitter and CTO combo, setup instructions using the Panelview HMI

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV

How to Change Your Medicine Bag

GAS STOVE GUARD for natural gas and propane stoves

Interpretation Guide. Coliform Count Plate

PHY 133 Lab 6 - Conservation of Momentum

AWNING CONTROL KIT 98GCK-33B

Product information Truma VarioHeat and E-Kit. July 2018

Assembling & Fitting Instruction August 2015

Model Number Structure

LBH18BPK. Instruction Sheet

HSCC. Interpretation Guide. High-Sensitivity Coliform Count Plate

VWR CARBOYS. Feature Versatile Cap Technology. Autoclavable. Shape maximizes bench and shelf space

Maintenance 45 Serie CAUTION. Before resetting your electronic card that displays an error code.

Lab Equipment. Perry High School. Your lab equipment should:

PRL486JDG 48-INCH GAS PRO GRAND RANGE WITH GRIDDLE (LP) PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

Cold Water Rheology Kit

Measures of Urban Trail Use in Minneapolis

User s manual EFS-150 USER S MANUAL EFS-150

Interpretation Guide

Interpretation Guide

Instruction Manual 12V Kerosene Start System Part Number: KS-1

Productivity. Technician. Maximized. Interpretation Guide

Job Aid. ESS - Create request for Self-ticketing (Low value fares)

TRUMPF TRUMATIC L 3050

Titan3 Syringe Filters. Sample Preparation 1-036

ORTHOPEDIC, TRAUMA TOURNIQUETS AND CUFFS

S.A.Q s: What are questions I should ask when contemplating into the design, specifying, or purchasing a fire pit?

shakers incubating shakers vortex mixers block heaters hotplate-stirrers specialty stirrers labjaws clamps lab-frames & supports

PRL364NLH 36-INCH GAS PRO HARMONY RANGE WITH GRILL (LP) PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

Display Systems. 1. General. A. Multi-Function Display (MFD) B. Primary Flight Display (PFD)

TAS Probe User manual Document version 1.0

SPEDESTER Series QUICK REFERENCE GUIDE

EDM4X, EDM2X. Product Specifications EXPANSION VALVE COILS ALL MODELS

Read all instructions and warnings before using this fireplace. WARNING

NAIPS Internet Service Authorised NOTAM Originator User Guide Version 3.0. (To be read in addition to NIS User Guide 3.0)

Inside. Residential Commercial Care Lifestyle Basins. Bathroom Range

PRD366GHU 36-INCH DUAL-FUEL PRO HARMONY RANGE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES

1250ul Extra Long Pipet Tips (Sterile, Non-Filtered) in 6 hinged racks $18.50

Pelican AMR Gateway User Guide

Mobile FliteDeck VFR Version Release Notes

Interpretation Guide 3M Petrifilm Rapid Coliform Count Plates

What is the best way to conserve groundwater? Make your own! With the AquaBoy home/business or commercial units.

QuickSilver Controls, Inc. Application Note:QCI-AN034

LINDSTRAND BALLOONS LTD MAINTENANCE MANUAL SUPPLEMENT NO. 2

Ultraviolet Sterilizers. Ultraviolet Sterilizers F61 30/06/17

Micro Brewery. can also supply piping, ladder and platform. We could also customize varied tanks according to customers requirements.

Nexus Standard Glove Box System

Filtration Equipment /Accessories : our weblinks

BAG-TO-BAG FILTER KIT FILTERED UNFILTERED GRN LINE WATER FLOW. USER MANUAL Model Number EPA Est. No UT-001

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Kit Information 3. Sample Preparation 4. Procedure 4. Analysis of Results 5. Quality Control 6. Disposal 6. Technical Support 6. Order Information 6

CrossLab. Supplies for Shimadzu GC System. to work for you non-agilent GCs. Put Agilent innovation and quality. Agilent. Quick Reference Guide

SECTIONING PROCEDURE FOR LASER CAPTURE MICRODISSECTION

Drinkers, Pipes & Fittings

AssayMAP Bravo Syringe Replacement

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

Safety,Monitoring and Accessories

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

Please read this guide carefully. It tells you how to prepare your cutting plotter for production use in a few easy steps.

ASXPRESS PLUS Rapid Sample Introduction System

Power Tong Torque Manual

Transcription:

====================================================== Date : Monday, November 14, 2005 10:31 File Name :.PRO Full Name : Abstract : QIAprepTurbo 96 QIAsoft 4.1.3, Version 6.1, 18.12.2001, EW, PK, HL, CK, KW This protocol is designed for the isolation of 96 plasmid DNA samples from 1.3ml bacterial cultures. Yield is up to 6µg. The protocol is written for BR8000R with 0.9mm Steel Probes and 2500µl Syringes. It s certified for version V0. It is ready to run on version V4. The protocol is not designed for versions V1, V2, V3, V5 and V6. Protocol Adjustments: e.g. date, initials, adjustment ====================================================== Variables defined for this protocol: (Comment, Name, Value, Default Value, Type, Min. Range, Max. Range) (SYS) Textual Indicator, BY_NAME, BY_NAME, BY_NAME, text (SYS) Textual Indicator, BY_NUMBER, BY_NUMBER, BY_NUMBER, text (SYS) Current Dest. Position, CurDPos,,, text (SYS) Current Source Position, CurSPos,,, text (SYS) Data Directory, DataDir, C:\Program Files\QIAsoft 4.1\Data\, C:\Program Files\QIAsoft 4.1\Data\, text (User) For Loop Counter, DryCounter, 5, 0, num, 0, 0 (SYS) Dilutor1 Size, DS1, 2500.00ul, 2500.00ul, num, 0.00, 0.00 (SYS) Dilutor2 Size, DS2, 2500.00ul, 2500.00ul, num, 0.00, 0.00 (SYS) Dilutor3 Size, DS3, 2500.00ul, 2500.00ul, num, 0.00, 0.00 (SYS) Dilutor4 Size, DS4, 2500.00ul, 2500.00ul, num, 0.00, 0.00 (SYS) Dilutor5 Size, DS5, 500.00ul, 500.00ul, num, 0.00, 0.00 (SYS) Dilutor6 Size, DS6, 500.00ul, 500.00ul, num, 0.00, 0.00 (SYS) Dilutor7 Size, DS7, 500.00ul, 500.00ul, num, 0.00, 0.00 (SYS) Dilutor8 Size, DS8, 500.00ul, 500.00ul, num, 0.00, 0.00 Elution Volume, ElutionVolume, 140µl, 125µl, num, 50, 150 (SYS) EQUAL-Operator ==, EQUAL, 4, 4, num, 4, 4 (SYS) Boolean Constant, FALSE, 0, 0, num, 0, 0 (SYS) GREATER or EQUAL-Operator >=, GREATEQ, 3, 3, num, 3, 3 (SYS) GREATER-Operator >, GREATER, 2, 2, num, 2, 2 (SYS) LOWER or EQUAL-Operator <=, LOWEQ, 1, 1, num, 1, 1 (SYS) LOWER-Operator <, LOWER, 0, 0, num, 0, 0 (SYS) Main Directory, MainDir, C:\Program Files\QIAsoft 4.1\, C:\Program Files\QIAsoft 4.1\, text (SYS) Number Of Samples, NoSam, 96, 96, num, 0, 0 (SYS) NOT-EQUAL-Operator <>, NOTEQUAL, 5, 5, num, 5, 5 (SYS) Position Counter, PosCount, 0, 0, num, 0, 0 Report File, ReportFile,,, text (SYS) Command Return Value, Return, 0, Return, text (SYS) Sample Positions, Samples,,, text State of System Liquid, SLstate, 0, 0, num, 0, 0 (SYS) Seconds until timer has elapsed, TimerValue, -517278, 0, num, 0, 0 Total Elution Volume, TotalElutionVolume, 16.1ml, 10.0ml, num, 0.0, 100.0 (SYS) Boolean Constant, TRUE, 1, 1, num, 1, 1 (SYS) Userdata Directory, UserdataDir, C:\Program Files\QIAsoft 4.1\UserData\, C:\Program Files\QIAsoft 4.1\UserData\, text State of Vacuum Trap Sensor, vacstate, 0, 0, num, 0, 0 State of Waste Bottle, wastestate, 1, 1, num, 0, 0 (SYS) Table Information, Info, tab Setting Volume Table, SettingVolumeTable, tab Protocol commands: ( 1) REMARK: QIAsoft 4.1.3, Version 6.1, 18.12.2001, EW, PK, HL, CK, KW Page 1

( 2) REMARK: BR8000R, 0.9mm Steel Probes, 2500µl Syringes ( 3) REMARK: ( 4) ROBOT CONTROL: Call method 'InitRobot' on device 'Robot' ( 5) DO LOOP ( 6) USER INTERACTION: Display Message: General Interactions Refill System Liquid Bottle. ( 7) DIGITAL IO: Read input from device 'System Liquid Sensor' into variable 'SLstate' ( 8) WHILE SLstate IS EQUAL TO 1 ( 9) DO LOOP ( 10) USER INTERACTION: Display Message: General Interactions Empty Waste Bottle. ( 11) DIGITAL IO: Read input from device 'Waste Sensor' into variable 'wastestate' ( 12) WHILE wastestate IS EQUAL TO 0 ( 13) DO LOOP ( 14) USER INTERACTION: Display Message: General Interactions Empty Vacuum Trap and Vacuum Condensate Trap. ( 15) DIGITAL IO: Read input from device 'Vacuum Trap Sensor' into variable 'vacstate' ( 16) WHILE vacstate IS EQUAL TO 1 ( 17) REMARK: ( 18) REMARK: BLOCK: Manual Setup ( 19) WIZARD Worktable Setup ( 20) USER INTERACTION: Display Message: General Interactions Fill both system liquid bottles with distilled water. Page 2

Empty vacuum trap and vacuum condensate trap. Empty waste container. ( 21) USER INTERACTION: Display Message: Rotor Setup Place 250ml Bottle Buffer A1 (with RNase A added) into Rotor Slot 1 250ml Bottle BufferA2 into Rotor Slot 3 500ml Bottle Buffer A4 (with ethanol added) into Rotor Slot 4 250ml Bottle Buffer A3 into Rotor Slot 5 500ml Bottle Buffer AW into Rotor Slot 6. DataDir\Bottle.bmp ( 22) USER INTERACTION: Display Message: Worktable Setup 1 Place a QIAplate Holder each into MP Slots 6, 11 and 16. <none> ( 23) USER INTERACTION: Display Message: Worktable Setup 2 Place NucleoSpin Filter 96 Plate into QIAplate Slot 6 and Seal unused wells. Place NucleoSpin Binding 96 Plate into QIAplate Slot 11. ( 24) USER INTERACTION: Display Message: Vac Setup Place Vac Filtration Adapter into QIAplate Slot 16. Place Vac Lid and Vac Top in the corresponding Vac Side Slot. ( 25) USER INTERACTION: Variable Input: Elution Volume Variable Name: ElutionVolume Default Parameters: No ( 26) EVALUATE TotalElutionVolume = ElutionVolume * NoSam * 1.2 / 1000 ( 27) USER INTERACTION: Display Message: Prepare Trough Rack Fill 12 ml Buffer AE into the disposable Trough in Therm Subslot A. DataDir\TroughRack.bmp ( 28) USER INTERACTION: Display Message: Elution Rack Page 3

Place a Microplate onto Elution Adapter into MP Slot 14. DataDir\Microtiter Plate.bmp ( 29) USER INTERACTION: Display Message: Sample Setup Place Flat-Bottom Block with samples into the Shaker back/left position. DataDir\Flat Bottom Block.bmp ( 30) END WIZARD ( 31) REMARK: ( 32) REMARK: BLOCK: Check Volume ( 33) FLUSH Probe to Use : All Probes Using Peristaltic Pump 30 ml Airgap After Flush : 0 Ask for More : yes ( 34) CHECK VOLUMES Check on Slot : Therm Subslot A Volume per Sample : yes Check One Fill All : yes Error on Less : yes Wash After Check : yes Airgap After Flush : 0 Alert Beep : yes Error on More : no Result on Error : yes Tolerance [ul] : 10 Offset [ul] : 0 Check the following positions: Position Volume [µl] Trough ElutionVolume ( 35) REMARK: BLOCK: Lysis ( 36) FLUSH DISPENSER Wash Volume [ml] : 30 ( 37) LOAD ROTOR Scan Rotor For Reagents : yes Check Expiration Date : no Check Volume : no Alert Beep : yes ( 38) FLUSH DISPENSER Wash Volume [ml] : 30 ( 39) ROBOT CONTROL: Call method 'CloseClamp' on device 'Shaker' ( 40) DISPENSE Reagent : BufferA1 Destination Slot : Shaker back/left Dispense Volume : 250 µl Prime Volume : 30 ml Wash Volume : 0 µl ( 41) START SHAKER Shake Duration : 04:00 Frequency : 1100 Interval : 30 ( 42) REMARK: -------------------- Assembly of Vacuum Manifold Page 4

( 43) MOVE RACK 'QIAplate Slot 16 Vac Base' Source Slot : QIAplate Slot 16 Destination Slot : Vac Base ( 44) MOVE RACK 'QIAplate Slot 11 Vac Base / Filtration Adapter' Source Slot : QIAplate Slot 11 Destination Slot : Vac Base / Filtration Adapter ( 45) MOVE RACK 'Vac Side Top Mount Vac Top Mount' Source Slot : Vac Side Top Mount Mount ( 46) MOVE RACK 'QIAplate Slot 6 Vac Top' Source Slot : QIAplate Slot 6 ( 47) REMARK: ( 48) FLUSH DISPENSER Wash Volume [ml] : 30 ( 49) WAIT until shaker finishes (Shaker) ( 50) START TIMER at 00:05:00. ( 51) DISPENSE Reagent : Buffer A2 Destination Slot : Shaker back/left Dispense Volume : 250 µl Prime Volume : 30 ml Wash Volume : 0 µl ( 52) START SHAKER Shake Duration : 01:00 Frequency : 600 Interval : 30 ( 53) FLUSH DISPENSER Wash Volume [ml] : 30 ( 54) WAIT until shaker finishes (Shaker) ( 55) WAIT until time has elapsed ( 56) DISPENSE Reagent : Buffer A3 Destination Slot : Shaker back/left Dispense Volume : 350 µl Prime Volume : 30 ml Page 5

Wash Volume : 0 µl ( 57) START SHAKER Shake Duration : 03:00 Frequency : 600 Interval : 30 ( 58) FLUSH DISPENSER Wash Volume [ml] : 30 ( 59) FLUSH Probe to Use : All Probes Using Peristaltic Pump 20 ml Airgap After Flush : 0 Ask for More : no ( 60) WAIT until shaker finishes (Shaker) ( 61) IF NoSam IS LESS THAN 96 ( 62) USER INTERACTION: Display Message: To Do... Penser a boucher les puits vides de la plaque filtrante avec un Tape Pad. DataDir\TurboFilter Plate.bmp ( 63) END IF ( 64) REMARK: ( 65) REMARK: BLOCK: Transfer and Filtration ( 66) EVALUATE SetIndexedPosVolumes(SettingVolumeTable, "Volume", "Shaker back/left") ( 67) TRANSFER Source Slot 0 : Shaker back/left Source Position 0 : Samples Aspiration Volume 0 : 1100 Dest Slot 0 : Vac Top Dest Position 0 : Samples Pos. Total Content : no Probe Select : All Steel Probes ( 68) START PUMP Pump Duration : 03:00 No Pressure Cont. : no Temperature : 60 Sample Binds to Membrane : 7426704 Use Press Down Feature : 7426748 Slot for Press Down Feature: Vac Top Using Vacuum Trap : Yes ( 69) FLUSH DISPENSER Wash Volume [ml] : 20 ( 70) FLUSH Probe to Use : All Probes Using Peristaltic Pump 10 ml Airgap After Flush : 0 Ask for More : no ( 71) ROBOT CONTROL: Call method 'OpenClamp' on device 'Shaker' ( 72) WAIT until vacuum pump finishes (RoboVac) ( 73) START TIMER at 00:00:05. Page 6

( 74) WAIT until time has elapsed ( 75) ROBOT CONTROL: Call method 'Heat' on device 'RoboVac' ( 76) START TIMER at 00:00:15. ( 77) WAIT until time has elapsed (Timer) ( 78) REMARK: -------------------- Move Vacuum Manifold ( 79) MOVE RACK 'Vac Top QIAplate Slot 6' Source Slot : Vac Top Destination Slot : QIAplate Slot 6 ( 80) MOVE RACK 'Vac Top Mount Vac Side Top Mount' Source Slot : Vac Top Mount Destination Slot : Vac Side Top Mount ( 81) MOVE RACK 'Vac Base / Filtration Adapter QIAplate Slot 16' Source Slot : Vac Base / Filtration Adapter Destination Slot : QIAplate Slot 16 ( 82) MOVE RACK 'Vac Side Top Mount Vac Top Mount' Source Slot : Vac Side Top Mount Mount ( 83) MOVE RACK 'QIAplate Slot 16 Vac Top' Source Slot : QIAplate Slot 16 ( 84) IF NoSam IS LESS THAN 96 ( 85) USER INTERACTION: Display Message: To Do... Penser a boucher les puits vides de la plaque filtrante d'elution avec un Tape Pad. DataDir\QIAprep Plate.bmp ( 86) END IF ( 87) REMARK: Page 7

( 88) REMARK: BLOCK: Bind and Wash ( A4 et AW) ( 89) START TIMER at 00:00:02. ( 90) WAIT until time has elapsed (Timer) ( 91) START PUMP Pump Duration : 02:00 No Pressure Cont. : no Temperature : 60 Sample Binds to Membrane : 7426700 Use Press Down Feature : 7426748 Slot for Press Down Feature: Vac Top Using Vacuum Trap : Yes ( 92) WAIT until vacuum pump finishes (RoboVac) ( 93) START TIMER at 00:00:05. ( 94) WAIT until time has elapsed (Timer) ( 95) ROBOT CONTROL: Call method 'Heat' on device 'RoboVac' ( 96) DISPENSE Reagent : Buffer AW Dispense Volume : 600 µl Prime Volume : 30 ml Wash Volume : 0 µl ( 97) START PUMP Pump Duration : 02:00 No Pressure Cont. : yes Temperature : 60 Sample Binds to Membrane : 7426700 Use Press Down Feature : 7426748 Slot for Press Down Feature: Vac Top Using Vacuum Trap : Yes ( 98) WAIT until vacuum pump finishes (RoboVac) ( 99) START TIMER at 00:00:05. (100) WAIT until time has elapsed (Timer) (101) ROBOT CONTROL: Call method 'Heat' on device 'RoboVac' (102) DISPENSE Reagent : Buffer A4 Dispense Volume : 900 µl Prime Volume : 30 ml Wash Volume : 0 µl (103) START PUMP Pump Duration : 02:00 No Pressure Cont. : yes Temperature : 60 Sample Binds to Membrane : 7426700 Use Press Down Feature : 7426748 Page 8

Slot for Press Down Feature: Vac Top Using Vacuum Trap : Yes (104) WAIT until vacuum pump finishes (RoboVac) (105) START TIMER at 00:00:05. (106) WAIT until time has elapsed (Timer) (107) ROBOT CONTROL: Call method 'Heat' on device 'RoboVac' (108) DISPENSE Reagent : Buffer A4 Dispense Volume : 900 µl Prime Volume : 0 µl Wash Volume : 0 µl (109) START PUMP Pump Duration : 02:00 No Pressure Cont. : yes Temperature : 60 Sample Binds to Membrane : 7426700 Use Press Down Feature : 7426748 Slot for Press Down Feature: Vac Top Using Vacuum Trap : Yes (110) FLUSH DISPENSER Wash Volume [ml] : 30 (111) WAIT until vacuum pump finishes (RoboVac) (112) START TIMER at 00:00:05. (113) WAIT until time has elapsed (Timer) (114) ROBOT CONTROL: Call method 'Heat' on device 'RoboVac' (115) START TIMER at 00:00:15. (116) WAIT until time has elapsed (Timer) (117) REMARK: -------------------- Move Vacuum Manifold (118) MOVE RACK 'Vac Top QIAplate Slot 12' Source Slot : Vac Top Destination Slot : QIAplate Slot 11 (119) MOVE RACK 'Vac Top Mount Vac Side Top Mount' Source Slot : Vac Top Mount Destination Slot : Vac Side Top Mount (120) MOVE RACK Alert Beep Silent Mode 'Vac Base QIAplate Slot 16' Source Slot : no : no : Vac Base Page 9

Destination Slot : QIAplate Slot 16 (121) MOVE RACK 'QIAplate Slot 12 Vac Base' Source Slot : QIAplate Slot 11 Destination Slot : Vac Base (122) MOVE RACK 'Vac Side Top Mount Vac Top Mount' Source Slot : Vac Side Top Mount Mount (123) MOVE RACK 'Vac Side Lid Mount Vac Lid Mount' Source Slot : Vac Side Lid Mount Destination Slot : Vac Lid Mount (124) REMARK: (125) REMARK: BLOCK: Dry plate (126) FOR DryCounter = 1 TO 4 WITH STEPSIZE 1 (127) START PUMP Pump Duration : 03:00 No Pressure Cont. : yes Temperature : 60 Sample Binds to Membrane : 7426700 Use Press Down Feature : 7426752 Slot for Press Down Feature: Using Vacuum Trap : No (128) WAIT until vacuum pump finishes (RoboVac) (129) START TIMER at 00:00:02. (130) WAIT until time has elapsed (Timer) (131) NEXT (132) START TIMER at 00:00:20. (133) WAIT until time has elapsed (Timer) (134) REMARK: -------------------- Move Vacuum Manifold (135) MOVE RACK 'Vac Lid Mount Vac Side Lid Mount' Source Slot : Vac Lid Mount Destination Slot : Vac Side Lid Mount Page 10

Using LabHand Detect object : yes : yes (136) MOVE RACK 'Vac Top Mount Vac Side Top Mount' Source Slot : Vac Top Mount Destination Slot : Vac Side Top Mount (137) MOVE RACK 'Vac Base QIAplate Slot 12' Source Slot : Vac Base Destination Slot : QIAplate Slot 11 (138) MOVE RACK 'MP Slot 13 Vac Base' Source Slot : MP Slot 14 Destination Slot : Vac Base (139) MOVE RACK 'Vac Side Top Mount Vac Top Mount' Source Slot : Vac Side Top Mount Mount (140) MOVE RACK 'QIAplate Slot 12 Vac Top' Source Slot : QIAplate Slot 11 (141) REMARK: (142) REMARK: BLOCK: Elution (143) DISTRIBUTE Source Slot : Therm Subslot A Source Position : Trough Use Max. Syringe Volume : yes Dispense Volume : ElutionVolume Probe Select : All Steel Probes (144) START TIMER at 00:01:30. (145) FLUSH Probe to Use : All Probes Using Peristaltic Pump 10 ml Airgap After Flush : 0 Ask for More : no (146) WAIT until time has elapsed Page 11

(147) START PUMP Pump Duration : 01:30 No Pressure Cont. : yes Temperature : 23 Sample Binds to Membrane : 7426704 Use Press Down Feature : 7426748 Slot for Press Down Feature: Vac Top Using Vacuum Trap : Yes (148) WAIT until vacuum pump finishes (RoboVac) (149) START TIMER at 00:00:20. (150) WAIT until time has elapsed (151) MOVE RACK 'Vac Top QIAplate Slot 11' Source Slot : Vac Top Destination Slot : QIAplate Slot 11 (152) MOVE RACK 'Vac Top Mount Vac Side Top Mount' Source Slot : Vac Top Mount Destination Slot : Vac Side Top Mount (153) MOVE RACK 'Vac Base MP Slot 13' Source Slot : Vac Base Destination Slot : MP Slot 14 (154) REMARK: (155) REMARK: BLOCK: End of preparation (156) IF CHOICE IS 'yes' (157) EVALUATE ReportFile = "QIAprepTurbo 96 Report File " + GetCurrentDate("%d.%m.%Y") + ".csv" (158) PRINT REPORT on runtime to file Report of protocol run Date/Time: {GetCurrentDate()}, {GetCurrentTime()} Protocol name: {GetProtocolName()}.PRO Executor:???Please enter name here??? Page 12

-------------------------------------------------------------------------------------- Number of processed samples: 96 Number of run (today):???please enter number here??? -------------------------------------------------------------------------------------- Comments------------------------------------------------------------------------------ (159) END IF (160) USER INTERACTION: Display Message: Process done Process done! Close all buffer bottles. Stop Button: No <none> Page 13