VKAP 3.0 NEW. Circular duct fans. Ventilateurs pour gaines circulaires. Rohrventilatoren. Runde kanalventilatorer CIRCULAR DUCT FANS

Similar documents
AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

NK Multi-stage submersible pumps

micro combustion chamber Mega vision of the flames precision control of combustion air, the control operates five air channels

Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h. Manufacturer. Model number/type. Production year. page

GRUPPI DI VENTILAZIONE

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

Eclipse Hermetic Gas Boosters Series HB

Emergency Stop Devices

MK3000. Operating and Calibration Instructions

1. INTRODUCTION GENERAL INFORMATION WORKING PRINCIPLE CUTTING SECTION SPECIFICATIONS INSTRUCTIONS FOR USE 5

RIS V NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit Wärmerückgewinnung

Special Three-Phase Motors with HSK-C Tool Holder for Manual Quick Tool Change

SPECIFICATIONS. Awnings. Sec. : Awnings Date : Dec 2017 ISSUE: AW

Industry best 5 year fan housing warranty, 1 year motor warranty

4 Storage cupboards SCALA

Looking for aluminium cut-to-length products?

Awnings ISSUE: AW Sec. : Awnings Date : Aug 2015

SONNENKRAFT COMPACT E & SKR 500

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

SONNENKRAFT COMPACT E EHP & SKR 500

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

MODEL CM BELT DRIVEN UTILITY VENT SET OVERVIEW

Conservatory awning W8 Description

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

APPLICATION CONSTRUCTION OPTIONS MODEL NAME TYPICAL APPLICATIONS STXB STXBW STXBHP STXBWHP STXBRHUL STXBWRHUL STXBHPRHUL STXBWHPRHUL

Capsule Filling Machine

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

FIBER OPTIC CLOSURES

p u m p s Technology. Innovation. Commitment. S T A I N L E S S S T E E L S U B M E R S I B L E P U M P S E n h a n c e y o u r l i f e

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

Data Sheet for Precision Potentiometer

Model Number Structure

Wood and pellet finally together as one

MODEL CFD Forward Curved Belt Driven Inline Duct Blower

AFA TS GmbH - Werner von Siemens Str.3 - D Grafenberg Copyright 2009 Tel.: +49(0) Fax: +49(0)

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

HEATER POWER CONTROLLER

Data Sheet for Precision Potentiometer

AXELENT WIRE TRAY Wire Trays, Fittings, Mountings and Accessories. Technical manual

14 Wood Bandsaw Scie à Ruban pour le Bois 14

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

TENDABOX BX3000. Cassette awning with folding arms BX3000. Description. Options:

PBG PACKAGED GAS BURNERS

FILTRONIC AB EXTRACTION ARMS AND NOZZLES FOR A BETTER WORKBENCH ENVIRONMENT

VERTICAL BLINDS AND CONSERVATORY AWNINGS safe timeless beautiful. markilux Technical Information. markilux

EC BRUSHLESS MOTOR APPLICATIONS

a Nexans company Catalogue 2009

Installation Instructions

BRAGI FUNCTIONAL LIGHT LINE FOR RETAIL, INDUSTRY AND WAREHOUSING

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

TYPE CERTIFICATE DATA SHEET

Installation Instructions

CASM electric cylinders The modular electric cylinder system

CAST IRON IMPELLER. VOLTAGE 50 Hz

Installation instruction

Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)

Type CGS High-Cap Screw Terminal Aluminum Electrolytic Capacitor

Installation Instructions

E2 Motors and Motor Starting. #1 Fan Motors

Safety Interlock Switches

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

Technical Blade Specification for LM 48.8 P rotor blade

I We reserve the right to modify or attar Instructions. No modification or

ELITE SERIES R-410A Ready - Multi-Position

Vacuum Hose Reel 881 Ex

Installation Instructions

CASM electric cylinders

Index. TerraPorte 7600 & accessable

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

Installation Instructions

RIS V. AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung

Job Name: Tag# 4 Port, 3-Ton Outdoor Heat Pump

General-purpose Relay

Chimney Stove. Nominal heating capacity Power range Efficiency. Swirl combustion chamber. schneeweiss schneeweiss weichsel Sonderglasur Serpentin

Model Number Structure

Model number. OXY-THERM FH burners. Forehearth burner - OXY-THERM FH. combustion systems for industry E-m -5/13. Burner model.

Installation Instructions

Installation instruction

Parts Catalog. Slicing Machine G10. Model:

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

TECHNICAL INFORMATION

Installation instruction

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

Mouthwatering. display. Features Cold Deli 3 Square. Cold Deli 3

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Optional accessories. markilux shadeplus. Optional accessories

AEROtube ET-Holder Laryngoscopes Laryngeal masks Endotracheal tubes Oropharyngeal tubes

PROCESS BURNERS INSTALLATION, COMMISSIONING AND MAINTENANCE MANUAL HMA2A SERIES AIR HEATING BURNERS

Service Manual / Manuel de Service

pulverisette 19 crushing sample preparation cutting mill for your lab Universal Cutting Mill

Sunea screen io EN ES PT EL Installation guide Guía de instalación Guia de instalação Ref C

TC30 BLACK DIAMOND BURNER KIT INSTRUCTIONS

Type Scott. Floor height: 90 cm

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Mod. MONTANA WOOD BURNING STOVE USAGE AND MAINTENANCE INSTRUCTIONS

Smallest Connector with Removable Contacts

Transcription:

VKAP.! NEW Circular duct fans Ventilateurs pour gaines circulaires Rohrventilatoren Runde kanalventilatorer 12 Circular duct fans are used for air supply or extract in ventilation and air conditioning systems. These fans are mounted into a system of round air ducts and can be installed in any position. Not suitable for polluted air, aggressive and explosive gases. Impeller with backward curved blades. Motor: external rotor, motor protection with built-in thermal-contact with manual reset, maintenance-free ball bearings. The casing is manufactured from galvanised sheet steel and folded, which ensures high air casing tightness. All VKAP. range comply with ERP 215. Mounting bracket LAV is included. Rohrventilatoren für Luftzufuhr oder Extrakt in Lüftungs-und Klimaanlagen eingesetzt. Sind in ein System von Luftkanälen runden montiert. Kann in jeder Position installiert werden. Nicht geeignet für verschmutzte Luft, aggressive und explosive Gase. Laufrad mit rückwärts gekrümmten Schaufeln. Motor: Außenläufer, Motorschutz mit integriertem Thermokontakt mit manueller Rückstellung, wartungsfreie Kugellager. Das Gehäuse besteht aus verzinktem Stahlblech gefaltet und die hohe Luftdichtheit Gehäuse gewährleistet. Rohrventilatoren Baureihe VKAP. entspricht der ERP-Richtlinie 215. Montagewinkel LAV darunter. Ventilateurs pour gaines destinés aux systèmes de ventilation et de climatisation en montage directe sur conduits d air circulaires. Utilisation en apport d air neuf ou extraction d air vicié. Le produit n est pas adapté au transport d air fortement pollué, de gaz agressifs ou explosifs. Turbine : réaction (pales incurvées vers l arrière). Moteur : rotor extérieur, entraînement direct, protection moteur intégrée par thermocontact, roulements à longue durée de vie ne nécessitant pas d entretien. Supports de montage LAV. Runde kanalventilatorer for montage i runde kanalsystemer. Valgfri monteringsposition. Ikke velegnede for uren luft, aggressiv eller eksplosionsfarlig luft. Ventilatorhjul med bagoverbøjede skovle. Ekstern rotormotor med indbygget termisk beskyttelse med manuel reset samt vedligeholdelsesfrie kuglelejer. Serie VKAP. overholder som minimum ErP 215 Der medleveres monteringsbeslag, type LAV.

Type Dimensions [mm] B C ød ød E VKAP 125 MD/LD. 182 14 24 125 286 VKAP 16 LD. 217 166 44 16 87 VKAP 2 LD. 21 179 44 2 87 VKAP 25 LD. 2 167 44 25 87 VKAP 15 LD. 256 188 42 15 444 1

VKAP LD. 14 12 8V 8 6 4 2 LD. L total, Lwa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 7 5 58 6 66 65 58 47 Outlet 71 54 6 61 67 66 58 48 Surrounding 61 4 58 44 55 54 47 7 Measured at 257 m /h, 14 Pa 14 The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 4565 resp. ISO 744 at a distance of 1 m from the fan.

VKAP 125 LD. 14 12 8V 8 6 4 2 125 LD. LWA total, Lwa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 69 5 54 6 65 64 56 47 Outlet 68 49 5 61 64 6 55 45 Surrounding 56 28 29 45 5 52 44 5 Measured at 28 m /h, 14 Pa * Under,125 kw the norms of ErP 215 are not applicable. The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 4565 resp. ISO 744 at a distance of 1 m from the fan. 15

VKAP 16 LD. 16 14 12 8V 8 6 4 2 16 LD. L total, Lwa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 74 52 67 68 71 62 62 52 Outlet 75 52 68 68 72 64 6 51 Surrounding 61 1 49 52 59 52 51 6 Measured at 685 m /h, 14 Pa 16 The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 4565 resp. ISO 744 at a distance of 1 m from the fan.

VKAP 2 LD. 2 18 16 14 12 8V 8 6 4 2 2 LD. LWA total, Lwa, Inlet 7 5 6 66 69 66 65 6 Outlet 74 54 62 65 7 67 67 6 Surrounding 58 25 5 46 5 55 47 45 Measured at 846 m /h, 12 Pa 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz 16 LD. 2 LD. Voltage/Frequency [V/Hz] 2/5 2/5 [kw],16,15 Current [A],45,56 Speed [min -1 ] 28 266 [m 866 7 Capacitor [µf] 2, 4, Max. air temperature [ C] 4 4 Weight [kg] 4 4,7 Wiring diagram No.1 No.1 Protection class: motor IP-44 IP-44 terminal box IP-55 IP-55 Comply with ERP 215 * + * Under,125 kw the norms of ErP 215 are not applicable. The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 4565 resp. ISO 744 at a distance of 1 m from the fan. 17

VKAP 25 LD. 2 18 16 14 12 8V 8 VKAP 15 LD. 6 4 2 25 LD. LWA total, Lwa, Inlet 74 54 62 67 69 67 67 65 Outlet 75 55 6 66 7 68 67 67 Surrounding 55 8 47 5 48 47 46 Measured at 81 m /h, 12 Pa 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz 5 25 8V 2 15 5 15 LD. L total, Lwa, Inlet 7 5 59 67 68 66 65 64 Outlet 74 51 6 66 69 67 66 65 Surrounding 5 8 45 48 47 45 4 Measured at 18 m /h, 149 Pa 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz 18 The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 4565 resp. ISO 744 at a distance of 1 m from the fan.

YE/GN BK RD BN C RD BU N L TK TK PE N L Protective earth PE, L1, N - line voltage C - capacitor TK - jumper 25 LD. 15 LD. Voltage/Frequency [V/Hz] 2/5 2/5 [kw],12,28 Current [A],56 1,6 Speed [min -1 ] 246 26 Capacitor [µf] 4, 5, [m 967 126 Max. air temperature [ C] 4 4 Weight [kg] 4,7 6, Wiring diagram No.1 No.1 Protection class: motor IP-44 IP-44 terminal box IP-55 IP-55 Comply with ERP 215 + + * Under,125 kw the norms of ErP 215 are not applicable. Wiring diagram No. 1 YE/GN - yellow/green BK - black RD - red BN - brown BU - blue 19