Installation instruction

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation instructions

Installation instruction

Installation Instructions

Installation instruction

Installation Instructions

Installation Instructions

Installation instruction

Installation instructions

Installation instruction

Installation instruction

Installation instruction

Installation instructions

Installation Instructions

Installation instruction

EC Declaration of conformity

Installation Instructions

Installation instruction

Contura 655/685 SE DE NO GB. Installationsanvisning 2 Installationsanleitung 16 Installasjonsanvisning 32 Installation Instructions 48.

Installation instruction Lighting Instructions

INSTRUCTIONS 31 31A 32 32A 33T

INSTRUCTIONS 31 31A 32 32A 33T

Handöl 21, 22 and 23T. Installation Instructions SE DE NO GB

Installation instruction

installations ANVISNING

Contura 650, 660, 670

Installation instruction

HARVIA IRON STOVE Instructions for installation and use

Alma Mons EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION

Lighting Instructions

K20. Installation Instructions Care and firing instructions

New! A little shining star

Fire for a new generation

Saltfire ST1 INSTALLATION AND OPERATING INSTRUCTIONS.

Saltfire ST4 INSTALLATION AND OPERATING INSTRUCTIONS.

K800. Installation instructions Care and firing instructions

INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE YSEN

DIANA EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION. Available in ceramic and metalsheet version.

Mod. MONTANA WOOD BURNING STOVE USAGE AND MAINTENANCE INSTRUCTIONS

Clay Adaptors & Insert Stove Kits

Harrie Leenders Fuga el - Instructions for Installation, Use and Maintenance INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

K700. Installation Instructions Care and firing instructions

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

APPENDIX TO THE INSTALLATION AND OPERATING MANUAL OF STOVEMAN SAUNA STOVE

K800. Installation instructions Care and firing instructions

Chimney Stove. Nominal heating capacity Power range Efficiency. Swirl combustion chamber. schneeweiss schneeweiss weichsel Sonderglasur Serpentin

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

Lighting Instructions

Installation and Operating Instructions

Inserts. Model 100, 200. Installation instructions Care and firing instructions

Saltfire ST3 INSTALLATION AND OPERATING INSTRUCTIONS.

Dry Stove Installation Guide BK545. November 2012 Rev02. EN 13240:2001+ Amd. A2:2004

Installation Instructions. Woolly Mammoth Stoves Albert Road, Braintree, Essex, CM7 3JQ

Contents. Welcome to Capital Fireplaces range of freestanding & inset stoves. General information 3 Sirius 645 freestanding stove 8

made by made by NEW UK 17/18

Maintenance 45 Serie CAUTION. Before resetting your electronic card that displays an error code.

Precision. Exactly right for you...

Installation and Operating Instructions

SIMPLY SOME OF THE FINEST STOVES AVAILABLE

our avalon stoves bring a traditional looking stove to your home with a more modern twist

Reference: Ottawa 12kw Operating Instructions Version 1 04/06/15. Installation and Operating Instructions

OPERATING INSTRUCTIONS

HEAT, LIFE AND ATMOSPHERE

Wood and pellet finally together as one

Cassette stove installation guide

SIMPLY SOME OF THE FINEST STOVES AVAILABLE

Installation and Operating. Instructions. Multifuel Stove. Salamander. Model Lighting a solid fuel fire. 6.5 De-ashing the stove

EXCEL ULTRABlack FS 6 Clearance Connector INSTALLATION AND MAINTENANCE INSTRUCTIONS

Aduro 10. User Manual. Ecolabel - Sintef EN Version 2

Dear Viking-customer,

SIMPLY SOME OF THE FINEST STOVES AVAILABLE

MULTI-FUEL STOVE INSTALLATION AND USER INSTRUCTIONS

HEAT, LIFE AND ATMOSPHERE

Asgård 7F User Manual Ecolabel - Sintef EN

Asgård 3 / Asgård 4 / Asgård 6

Aduro 6 / Aduro 6-5 / Aduro 6SK

Accentra Pellet Insert Installation into Zero Clearance Wood Fireplaces

Bloomsbury SE SMOKE EXEMPT WOODBURNING STOVE INSTALLATION & USER INSTRUCTIONS (TO BE LEFT WITH THE CUSTOMER) UK & IRELAND GUARANTEE

Norvik 5 Multi-fuel stove 80% Efficient

Glás Non Boiler Insert

Dry Stove Installation Guide

Please read this manual before installation and use. We wish you many years of pleasure and warmth.

Installation and Operating Instructions. Ottawa 12kw

Lighting Instructions

ECO-FRIENDLY WOOD-BURNING STOVES OF DANISH DESIGN

O P E R A T I O N AND INST A L L A T I O N M A N U A L

How to use a multi fuel stove

ECO-FRIENDLY WOODBURNING STOVES

EKOL CRYSTAL-8 INSTALLATION AND OPERATING INSTRUCTIONS

OPERATION AND INSTALLATION MANUA L OPUS TEMPO

Instructions for installation and use S MORSØ JERNSTØBERI A/S. DK-7900 NYKØBING MORS Website:

Advanced Technology kept simple Designed and Manufactured in the UK

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Saltfire ST2 INSTALLATION AND OPERATING INSTRUCTIONS.

Varde Lyon Varde Nice

SOLID FUEL STOVE ELITA and ELITA II

BLOOMSBURY SE 8kW Smoke Exempt Multi-Fuel Stove

Transcription:

NO DK FR NL Installation instruction 2 Installasjonsanvisning 17 Monteringsvejledning 33 Guide d installation 49 Installatie instructies 65 Installation instruction C850W contura.eu

2 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. C850W-CPR-130610-SE-1 PRODUCT Product type Type designation Manufacturing number Intended area of use Fuel Stove lit with solid biofuels Contura 850W See rating plate on the stove Heating of rooms in residential buildings Wood MANUFACTURER Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden CHECKS According to AVCP System 3 European standard EN 13240:2001 / A2:2004 Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625, has checked declared performance and issued test report no. RRF-40 11 2656 DECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire NPD Minimum distance to combustible material Side: 500 mm Other safety distances according to the installation instructions Risk of falling embers Pass EN 13240:2001 / A2:2004 Emissions from combustion CO 0,07% Surface temperatures Pass Cleaning options Pass Mechanical durability Pass Emissions of hazardous substances Pass Nominal output 4 kw Efficiency 82% Flue gas temperature in connector at nominal output 320 C The undersigned is responsible for the manufacture and conformity with the declared performance. Niklas Gunnarsson, Business area manager NIBE STOVES Markaryd, 1st July 2013

CONTENTS 3 A warm welcome to Contura. A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new stove. As a new owner of a Contura stove, you have secured a product with timeless design and long service life. Contura also has a combustion process that is both environmentally friendly and efficient, for the best heat production. Read through these installation instructions carefully before installation. Read how to best light your stove in the lighting instructions. List of Contents Technical details 4 Prior to installation 4 Connection to chimney 5 Installation distances 6 Supply of combustion air 6 Installing C850W 7 Removal 14 NOTE! Report the installation of a stove to your local authority. The owner of the house is personally responsible for ensuring compliance with the mandatory safety requirements and must have the installation approved by a qualified inspector. Your local chimney sweep must also be informed about the installation as this will affect the routines for regular chimney-sweeping services. WARNING! The stove becomes very hot During operation, certain surfaces of the stove become very hot and can cause burn injuries if touched. Also, take heed of the strong heat radiated through the door glass. Placing flammable material closer than the safe distance indicated may cause a fire. Smoulder combustion can cause quick gas ignition with the risk of damage to property and personal injury.

4 FACTS Technical details Important to remember! Effect 3-6 kw Nominal effect 4 kw Efficiency up to 82% Model 850W Height (mm) 615 Width (mm) 460 Depth (mm) 360 Weight (kg) 75 Type approved in accordance with: European standard EN-13240 Swedish approval Norwegian standard NS 3059 German standard DIN Plus Installation by authorised technician This manual contains instructions about how the stove must be assembled and installed. To ensure the function and safety of the stove, we recommend that the installation is carried out by an authorised technician. Contact one of our dealers who can recommend suitable fitters. Building permission Before installing a stove or erecting a chimney, it is necessary for you to make an application for building permission to your local authority. Ask your local authority for advice regarding building regulations and the application. Structural support The wall must be strong enough to bear the weight of the stove and chimney. Floor plate Due to the risk of falling embers, a flammable floor must be protected by a hearth plate. It must extend 300 mm in front of the stove and 100 mm on each side of the stove, or have a 200 mm extension on each side of the opening. The hearth plate can consist of natural stone, concrete, metal plate or glass. A painted metal or glass hearth plate is available as an accessory for these models. Prior to installation If the insert needs to be put down to be moved, remove any loose components. This is described at the end of these installation instructions. 1 3 1 Fire bars 2 Grate disc 3 Firebricks 4 Type plate 5 Hot air grate 2 4 5

CHIMNEY 5 Connection to chimney The stove meets the requirements for connecting to chimneys dimensioned for 350 C flue gas temperature. The external diameter of the connection sleeve is 150 mm. The stove requires a draft in the chimney of at least 12 Pa. The draft is affected both by the length and area of the chimney, and by how well sealed it is. Minimum recommended chimney length is 3.5 m and suitable cross section area is 150-200 cm² (140-160 mm in diameter). A flue with sharp bends and horizontal routing reduces the draught in the chimney. The maximum horizontal flue is 1 m, on the condition that the vertical flue length is at least 5 m. It must be possible to sweep the full length of the flue and the soot doors must be easily accessible. Carefully check that the chimney is sealed and that there is no leakage around soot doors and flue connections. Rear connection to a masonry chimney The back panel must be installed before the stove is rear connected. 1 Ø ca 180 mm Ø approx. 180 mm 2 In the bag with these installation instructions are two wing screws for the cover. 3 4

6 INSTALLATION DISTANCE / SUPPLY Installation distances C850W Brännbart tak Combustible roof 800 Firewall*** Brandmur *** 11 464 Min 300 615 Min 1000 Min 300 1100 Brännbar vägg Combustible wall 200** 430** 400 300 193 375 Utv. Ø150 Ext. Ø150 100 56 484 100 Firewall*** Brandmur *** 11 200 193 375 114 Air Tilluftsstos inlet Ø67 Ø67 500 730 ** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used. *** Example of an approved firewall is 120 mm solid brick with the following values: (Thermal conductivity (λ) = 0.6-0.7 W/m *K, Density = 1500-1700 kg/m³, as well as Specific heat capacity (c) = 840 J/kg *K). Supply of combustion air Combustion air can be supplied via a duct from outside, or indirectly via a vent in the outer wall of the room where the stove is placed. The amount of combustion air that is used for combustion is approx. 25 m 3 /h. HK Indirect air supply through the external wall

ASSEMBLY 7 Installing of C850W 1 2

8 ASSEMBLY 3 Ø 8 mm Position the back plate opposite the connector. Check that the back plate is vertical and mark the mounting holes that you intend to use. Choose a hole so that it ends up as far away from any mortar joints as possible. Predrill the hole with an 8 mm masonry drill, the hole must be at least 80 mm deep. Clean the hole thoroughly and secure the back plate to the chimney breast with the 6 masonry screws supplied. Screws that do not engage must be considered ineffective and moved to another hole. 4 5 Insert the connection pipe into the wall connector towards the folded tabs.

VANADIUM No. 7 CHROME 10 VANADIUM No. 7 CHROME 10 GB ASSEMBLY 9 6 50 mm Ensure that the pipe protrudes 50 mm from the back plate and seal using the sealing yarn between the wall connector and the connection pipe. If further sealing material is required, heatresistant sealant may be used. 7 8 10 10

10 ASSEMBLY 9 10

ASSEMBLY 11 11 12

12 ASSEMBLY 13 Place the rating plate with production number and installation distance on the protective plate with the plate turned downwards. 14

ASSEMBLY 13 15 16 Final inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used. Also read the "Lighting instructions" before lighting for the first time.

14 REMOVAL Removal How to remove the firebricks Handle the firebricks with care. Lift the smoke baffle with one hand whilst removing the sides. The side posts need not be removed when sweeping. Reinstall in reverse order. 1 2 3

NIBE AB Box 134 SE-285 23 Markaryd Sweden www.contura.se 811241 IAV EX C850W-3 2018-09-26 Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice. The current edition can be downloaded from www.contura.eu