ECLIPSE AIR HEAT BURNERS Series AH-O & TAH-O

Similar documents
Design Guide. No. 160, 8/1/05. AirHeat Burners. AH-MA Series. Version 2

Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1

PBG PACKAGED GAS BURNERS

HMA 2 & HMA 2A. Installation and Service Instructions. Direct-Fired Gas Burners. The Blue Flame Series. Features and Benefits

PROCESS BURNERS INSTALLATION, COMMISSIONING AND MAINTENANCE MANUAL HMA2A SERIES AIR HEATING BURNERS

JAG JET AIR GAS BURNER

Specifications of KINEDIZER burners

Specifications of "NP" & "RG" AIRFLO burners NP-I & NP-II AIRFLO burners

Gas Conversion Kits and Instructions

XPO. Ultra low NOx indirect burner

Fire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A

Installation and operation instructions for KINEMAX burners

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

SECTION I-1. Type: 1812-AC. Fuel: Air-Gas.

Endless Choices. Masterful Results.

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

PRD366GHU 36-INCH DUAL-FUEL PRO HARMONY RANGE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

RAMFIRE Burners. Improve your furnace temperature uniformity and work penetration with rapid circulation

PRL364NLH 36-INCH GAS PRO HARMONY RANGE WITH GRILL (LP) PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

Supersedes: AD3V (991) AD3V (1294)

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations

Specifications of NP-LE AIRFLO burners

Specifications of "NP" & "RG" AIRFLO burners NP-I & NP-II AIRFLO burners

The four elements of nature: Fire, Water Earth & Air

Economical and Dependable Heat

Installation Instructions

PRD366JGU 36-INCH DUAL-FUEL PRO GRAND RANGE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PRL364NLG 36-INCH GAS PRO GRAND RANGE WITH GRILL (LP) PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

The Concorde Series Cast Iron Stoves

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS JUMBO/JUMBO SLIMLINE LOG SYSTEMS

Check burner weight and reinforce burner mounting flange or combustion chamber/furnace back wall if necessary to take complete burner weight.

PRG366JG 36-INCH GAS PRO GRAND RANGE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

UNI-RAD. Gas Fired Radiant Tube Burner System

Air inlet. 1. Drilled Pipe - Typically drilled pipe uses more compressed air while producing inconsistent flow at high noise levels.

Design Princples for Wood Burning Cook Stoves

DIRECT VENT GAS STOVES

Manufactured in New Zealand Metal Fab Industries Ltd PO Box Greenmount Auckland

Check burner weight and reinforce burner mounting flange or combustion chamber/furnace back wall if necessary to take complete burner weight.

The four elements of nature: Fire, Water Earth & Air

PRL486JDG 48-INCH GAS PRO GRAND RANGE WITH GRIDDLE (LP) PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PRD486WDHU 48-INCH DUAL-FUEL PRO HARMONY RANGE WITH GRIDDLE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE RANGETOP

BURNER RANGE XL900 XL700

DOMESTIC LPG STOVE. Profile No.: 46 NIC Code: INTRODUCTION: 2. PRODUCT & ITS APPLICATION:

OÜ Skamet Reg. Nr Savi 9, Pärnu, Estonia

OXY-THERM LE Burners Series 600 Series 900 Series 1200 [2] Maximum capacity range MBtu/h 0.2 to to 11 5 to 15 [3] Turndown 5:1

XPO. Ultra low NOx indirect burner

"NP" & "RG" AIRFLO. In-duct firing line burner

Instructions for use, installation, and connection. Gas Built in Hob

Pro 88/86. The classic torch system. All components are carefully chosen to guarantee long service life. Ergonomic designed handles

Series LV AIRFLO. In-duct firing line burner

Glammbox Crea7ion.E. GlammFire. Crea7ion by GlammFire. GlammFire

PROPANE LANTERNS LIMITED WARRANTY. All propane lanterns carry a

Torches and Burners Vapor Torches

How to Set up Your Configurable (Home and Camping) Stir Fry Stove

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

S.A.Q s: What are questions I should ask when contemplating into the design, specifying, or purchasing a fire pit?

Section 8: Supplements

Series NP-LE AIRFLO IN-DUCT FIRING LINE BURNER TECHNICAL CATALOG

Some Experiments With Sawdust-Burning Stoves

micro combustion chamber Mega vision of the flames precision control of combustion air, the control operates five air channels

PILOTED OXYGEN SINGLE HOLE BURNER TIPS

Eclipse Hermetic Gas Boosters Series HB

direct vent gas fireplaces

Lit Table Top Firepit Bio-Ethanol Fireplace. User Manual. Model: GF301650

New requirements. new solutions. A state of mind

AFA TS GmbH - Werner von Siemens Str.3 - D Grafenberg Copyright 2009 Tel.: +49(0) Fax: +49(0)

GAS STOVE GUARD for natural gas and propane stoves

Torches and Burners Vapor Torches

Design and Application Details Style A, B & C LINOFLAME Burners

Cucina genesi G9S-4T SS OT Steel G20/20 230/50 EU

Freestanding Gas Fryers

For draining expansion tanks, other liquid storage vessels.

TCWS54 BLACK DIAMOND BURNER KIT INSTRUCTIONS

TC30 BLACK DIAMOND BURNER KIT INSTRUCTIONS

Chimney Stove. Nominal heating capacity Power range Efficiency. Swirl combustion chamber. schneeweiss schneeweiss weichsel Sonderglasur Serpentin

Cucina Sintesi M12SF-4TM SS OT Lancellotti G25/25 230/50 NL

17500 VRANJE, SRBIJA Radnička 1, Tel.: 017/ INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT AND USE

Cucina sintesi S12FF-4BF X S Steel G20/20 230/50 EU 08/11/2007

EDM4X, EDM2X. Product Specifications EXPANSION VALVE COILS ALL MODELS

TC42 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

TC30 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS

SELECT 6 GAS STOVE. Installation and Servicing Instructions

SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: ZH/ZJ/ZR , ZF

Cucina sintesi S9F-6 X S Steel G20/20 230/50 EU 08/11/2007

Excess air burner BIC..L

Style # Laguna Propane Tank Cover Owner s Manual

STOVES & INSERTS PRO-SERIES. PRO-SERIES WOOD STOVES & INSERTS

XL900 BIOETHANOL BURNERS

Product Presentation. Classic Deck Ovens

EB300. Ethanol Burner. User s Manual Installation Instructions

Suggested tools: Flat head screw driver, power drill, ¼ drill bit, 24 level, and a tape measure. HARDWARE LIST (2) FUEL CANISTER HOLDER

SMART BIO-ETHANOL ELECTRONIC BURNER

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

STOVES & INSERTS PRO-SERIES PRO-SERIES.

Saltfire ST1 INSTALLATION AND OPERATING INSTRUCTIONS.

TENTS, CANOPIES AND TEMPORARY MEMBRANE STRUCTURES

TECHNICAL SUPPORT HOT LINE HOURS: 7:30-3:30

Key Largo Fire Pit. Installation Instructions. 1 P a g e. NorthlineExpress.com. Toll-Free

Transcription:

ECLIPSE AIR HEAT BURNERS Series AH-O & TAH-O U.S. Reissue Pat. No. 26,244 Canadian Pat. No. 743,782 Spec 144 11/4/03 AH-O, Front View Data 144-1 AH-O, Back View Data 144-1 TAH-O, Front View Data 144-2 Eclipse AH-O and TAH-O Air Heat Burners are line type burners ideal for generating large volumes of clean, hot air. They are designed for mounting in ducts where all of the oxygen required for combustion is available from the process airstream. Applications include ovens, dryers, fume incinerators, make-up air heaters, and similar industrial equipment. Because these burners depend on the airstream for combustion air, a profile plate must be used to establish proper air velocity past the burner. Air temperatures can be as high as 450 F (250 C) upstream of the burner, and 1000 F (540 C) downstream. Low NOx, CO and aldehydes. Air temperatures up to 450 F (250 C) upstream of the burner. Inputs up to 1,000,000 Btu/hr. per lineal foot of burner (962 kw/m), depending on air velocity Wide range of configurations, packages, and accessories. ECLIPSE COMBUSTION 1

Specifications Inputs & Pressures: Fuels: See table below. Natural gas or 100% propane vapor. Call Eclipse for information on using other fuels. Airstream Temperatures: Upstream of Burner: 450 F 250 C Downstream of Burner: 1000 F 540 C Oxygen Level: 18% oxygen required in the process airstream. Net Free Area: 10 sq. in. per lineal foot 212 sq. cm per lineal meter Pilot Input: Piloting: Flame Monitoring: Materials: Emissions: Approximately 25,000 Btu/hr. (7.3 kw) Integral spark-ignited pilot; ignition plug included. Flame rod supplied. UV scanner adaptors are available. For UV scanners, Eclipse recommends a flame monitoring system that terminates the ignition spark and proves the pilot flame without spark prior to opening the main gas valves. Burners over 5 lineal feet include flame supervision at the far end. If pilot ignition is being used, two flame supervision units are required; one for the pilot and one for the far end. If using direct spark on the main flame, only flame supervision at the far end is required providing that ignition can be accomplished within 15 seconds. (Reference NFPA 5-9.2.2) CGA requires two flame rods on burners over 36" long (914 mm). Use a flame monitoring endplate (see Data 140-6) to mount a second flame rod on the end opposite the gas inlet. All portions of the burner exposed to flame are cast iron or #321 stainless steel. Emissions performance depends not only on the burner, but also other factors such as chamber temperature, chamber design, and heat loading. For estimates of emissions performance in your application, call Eclipse. Packaging Options: Available with complete valve trains and control systems. AH-O burners and systems can be supplied mounted on duct sections as specified by the customer. Call Eclipse for information on custom packaged systems. Models: Model Description Data Sheet AH-O Line-shape Data 144-1 TAH-O I -shape Data 144-2 Related Information: Flame monitoring accessories and endplates Data 140-6 Ordering details and worksheet Data 140-7 Inputs, Pressures, & Flame Lengths Gas Pressure* Air P Air Flow Flame Across Per Area Rated Input Nat. Gas Propane Length** Burner of Opening 550,000 Btu/hr/ft 1.2" w.c. 0.5" w.c. 18-24" 0.4" w.c. 13.6 scfm/in. 2 800,000 Btu/hr/ft 2.2" w.c. 0.9" w.c. 24-30" 0.7" w.c. 17.6 scfm/in. 2 1,000,000 Btu/hr/ft 3.5" w.c. 1.3" w.c. 40-46" 1.0" w.c. 21.5 scfm/in. 2 530 kw/m 3.0 mbar 1.2 mbar 46-61 cm 1.0 mbar 3.39 Nm 3 /hr/cm 2 762 kw/m 5.5 mbar 2.2 mbar 61-76 cm 1.7 mbar 3.39 Nm 3 /hr/cm 2 962 kw/m 6.2 mbar 3.2 mbar 102-117 cm 2.5 mbar 5.36 Nm 3 /hr/cm 2 * Measured between the gas inlet and a tap on the duct wall 10" to 20" (25 to 50 cm) downstream of the burner. ** Flame length is a function of burner input, air P and air flow across burner face. If flame length is not critical, then these figures may vary. Air at 70 F and sea level. Required flow per unit area of combined profile opening and burner net free area to produce the corresponding air P. CAUTION: It is dangerous to use any fuel burning equipment unless it is equipped with suitable flame sensing devices and automatic fuel shut-off valves. Eclipse can supply such equipment or information on alternate sources. 2

Profile Plate Sizing To calculate the open area between the burner perimeter and the edge of the profile plate opening, solve the following equation: = (A NF x L F ) where Example Size a profile plate for a seven foot long burner to fire at 800,000 Btu/hr. Air flow around and through the burner will be 60,000 scfm. = 60,000 scfm = 21.5 scfm per sq. in. (from page 2) A NF = 10 sq. in. per ft. (from page 2) L F = 7 ft. = Area in of the gap between the profile plate and the burner. = Total air flow around and through the burner. = Air flow required per unit of open area to produce the specified pressure drop. A NF = Burner net free area, from page 2 = Burner length. L F = 60,000 21.5 (10 x 7) = 2720 sq. in. Profile Plate Design & Mounting Guidelines The profile opening must provide uniform air flow down the length of the burner. If the exact air flow is in doubt, provide adjustable profile plates so that final settings can be made in the field. Duct Width 6" Min. Top & Bottom Profile plates should be positioned flush with the firing end of the burner. If necessary the plates can be located up to l/2" back from the firing end, but under no circumstances should they be in front of the burner. Center the burner in the duct. Duct Height As Required, Top & Bottom Allow a minimum of 46" (1168 mm) from burner to nearest point of possible flame impingement at an input of 800,000 Btu/hr/ft (770 kw/m). Burner Profile Plate 3" Min. 4" Max. Both Ends 6" Min. Both Ends 3

Burner Firing Arrangements The AH Burner can fire in any direction. Flow through the burner s check valve, however, must be horizontal. A guide for identifying some standard arrangements is shown below. Be sure to indicate the appropriate number arrangement when ordering. If no arrangement is indicated, No. 1 will be furnished as standard. Horizontal Firing No. 2 No. 1 (Standard) Vertical Firing Up No. 5 Vertical Firing Down No. 6 No. 4 No. 3 End Firing No. 7 No. 8 End Firing No. 10 No. 9 ECLIPSE COMBUSTION Litho In U.S.A.

Offered By: Power Equipment Company 2011 Williamsburg Road Richmond, Virginia 23231 Phone (804) 236-3800 Fax (804) 236-3882 www.peconet.com