A EURO-QUALIFLEX (AEQ) MEMBER. Publish date Rev. No: 01

Similar documents
A EURO-QUALIFLEX (AEQ) MEMBER.

FLEXIBLE METAL HOSE.

SUBMITTAL PACKAGE FLEXIBLE SPRINKLER DROP

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001

INSTALLATION GUIDELINES

Metal & Teflon Lined Hose

COOPER FREESTANDING TUB FAUCET INSTALLATION

GoBidet Bidet Attachment

Automated Tiki Torch Installation Instructions

Rapidrop Flexible Sprinkler Connections Keeping the art of distribution simple

INSTALLATION INSTRUCTIONS TOWNSEND

AND LOAD CANOPY RACK SPECIFICATIONS

Operating Instructions

RTA flexible conduits

Operating Instructions

Installation Instructions for the Rolltec Adalia X3M Extenda Awning

Hose Reel Series L701/G701

300 Model 870 Four Wheel Hose Cart Owner s Manual

--- BIG LEAGUE BATTING CAGE ---

RETRACTABLE AWNING w/ OPTIONAL HOOD ASSEMBLY INSTRUCTIONS

Daikin Fire Rated Hoses & Hose Kits for Water Source Heat Pumps. Catalog People and ideas you can trust.

industrial ball valves

INSTALLATION & MAINTENANCE MANUAL SERIES 9000 MODELS 9150/9300 SERIES 9000 VALVES WITH V BALL


Advantage Plus TIM-3600 Series Reel

LP Grill and Gas Hose

Installation Instructions for the Rolltec Bravo Awning

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

FLAIR TWO-HANDLE BATH & SHOWER FAUCET

Installation Instructions for the Rolltec Physique XL Awning

Urea/Adblue Hose Reel

OWNER S TECHNICAL MANUAL

Gas Conversion Kits and Instructions

MR98 Series Backpressure Regulators, Relief and Differential Relief valves

WIDESPREAD LAVATORY MODELS WITH HI-ARC SPOUT

I- 39. Liquidtight Connectors and Hubs for Liquidtight Flexible Metal Conduit General Information and special features.

Contents. Awnings USA - Full Protective Hood Manual Instructions ft 11" - 11ft 6" Awnings

Clay & Bailey Mfg. Co.

Contents. Introduction...3 Description...3. Pack Contents...4. Rada Heavy Duty EV Shower Fittings Right Angled Connector (RAC)...

Trunk Connection Type (provided) FNPT (Std.) MNPT FSWT

Primrose Awnings - Full Cassette Manual & Electric Instructions

JARVIS. Model 70 Airsnip Air Powered Scissors

Spiral Duct. Contents. Introduction 1. Duct & Fitting Range 2. Duct Sizes 3. Fittings 5. Round Duct Connector 7. Installation 8

Installation Instructions

Hose Clamps & Fittings

Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1

BROEN UNIFLEX FITTINGS FOR WATER BROEN UNIFLEX TM FITTINGS FOR WATER

Graphite Ribbon/Filament Packing for Fisher Sliding Stem Valves

7. Do not dispose of the packaging immediately.the package insert contains a template for mounting the slide bar A/Rev01 G1/2" G1/2" G1/2"

Clay Adaptors & Insert Stove Kits

TROLLEY-MOUNTED HOSE REELS

STIH) Technical Information Cut-off machine STIHL Cutquik TS 410, 420 Series Guard with defined adjustment range

CABLE GRIPS CABLE GRIPS

A A A T E C H N O L O G Y

Value-Line 1", 2" & 3" (DN 25, 50 & 80) Series 6FRF 2-Piece Ball Valves. Installation, Maintenance and Operating Instructions

Tuf-Lite and Tuf-Lite II Fans 6000M Series Hub

Instructions for use. Bure. Walker. Bure Standard GAS Bure S GAS Form #2-245 Rev. 8/15/18

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

SteadiCam Parts List*

Model SBS-10. Stainless Steel Simplex Basket Strainer. 21 Columbus Avenue Garfield, NJ 07026

Foam Systems Engineering Design Manual

TOOLING COMPONENTS. tel fax Clamping Kits Step Blocks...7. Driver Studs...

IMPORTANT OWNER-OPERATOR INSTALLATION INSTRUCTIONS C2204A

4-foot Economy Sign Post. 4-foot post is rated at 2 pounds per foot. 7-foot Economy Sign Post

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

INSTRUCTION MANUAL ALEKO RETRACTABLE AWNING

Installation Instructions for Wall Mount, Deck Mount and Pre-rinse Faucets

TC30 BLACK DIAMOND BURNER KIT INSTRUCTIONS

SERVICE MANUAL V-SERIES HEAVY DUTY BROILERS, DOUBLE DECK AND RANGE MATCH MODELS - NOTICE - For a complete listing of models, see the MODELS section.

300 ft. 5/8 Hose wagon

Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind.

Installation instruction

Reverse Osmosis system 50 GPD Instruction manual EN

INSTRUCTIONS FOR MVK-NQM PILOT KIT

Model 698/ and Model in 1 Hose Reel Owner s Manual

ABS Model Background Stand

Rhino-Rack SUNSEEKER Awning Black

ASSEMBLY GUIDE. Customer Service: INCH² 2-BURNER & 864 INCH² 2-BURNER

Ball Valve Manual Balance Hose Kits - Submittal

Showers and Shower Accessories 57

Ground Clamps Cable Tray

When moving the frame don t force anything! Move the leg to allow the brace to go over the rod.

Emergency Stop Devices

Primrose Awnings - Standard Manual Instructions

VALORE SEVEN. Serial Number. Pacific) Version No.:V

Victaulic Vic-Flex Sprinkler Fittings Series AH1 and AH1-CC Braided Flexible Hose 10.95

IMPORTANT OWNER-OPERATOR INSTALLATION INSTRUCTIONS. Part # A7006

Manufactured in New Zealand Metal Fab Industries Ltd PO Box Greenmount Auckland

ADVANCE PRODUCTS & SYSTEMS, INC. FOR FLANGES, VALVES & EXPANSION JOINTS SAFETY SPRAY SHIELDS CONTAINS AND DETECTS HAZARDOUS SPRAYOUTS

CORALAIS THREE-HANDLE BATH/SHOWER FAUCET

Deluxe, heat resistant slide system: Quadro for ovens

FILTERED FAN PACKAGES

Model Max. Surface m 2 Min. Width mm Max. Width mm Min. Height mm Max. Height mm Solar Guard , ,000

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

250 SERIES 1" STRUCTURAL TUBE MULLION ASSEMBLY INSTRUCTIONS

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Kauai III ShowerSpa MODEL # 1011-III-CH, 1011-III-BN, 1011-III-ORB GENERAL DESCRIPTION PRODUCT FEATURES SPECIFICATIONS

Primrose Awnings Half Cassette Manual & Electric Instructions

Transcription:

A EURO-QUALIFLEX (AEQ) MEMBER. www.ayvaz.com Publish date 18.12.2017 Rev. No: 01

FLEXIBLE SPRINKLER CONNECTION HOSES (UL) Sprinkler Systems are automatic fire sensing and extinguishing systems that splash the water comes through connected pipeline. Public places like shopping malls, theatres, concert halls, hotels where the intervention time is crucial are the places where these systems are commonly chosen and used. Ayvaz sprinkler hose and assembly kit can be effectively used in these systems and come over many connection difficulties caused by rigid piping. ADVANTAGES Flexible structure of stainless steel corrugated hose provides various advantages; Hose assembly is not affected by external movements and is able to suspend seismic motions. Flexibility of the hose provides required safety for all systems. Easy installation the hose and the sprinkler device into ceiling with assembly kit save on installation time and costs by eliminating pipe wastage and reducing the labour associated with cutting, threading, and sealing pipe threads. It is so easy to align and tighten sprinkler side of the hose with desired point of ceiling. Also, due to smart design of the fixing kit, sprinkler side of the hose can easily be moved and adjusted on vertical axis. It is not necessary to adjust sprinkler location if ceiling alignment and level are changed. Stainless steel hose and braiding provide high resistance against heat and temperature. The system is highly resistant against corrosive effect of the water that is kept in the hose for a long time. Scan this QR Code

FLEXIBLE SPRINKLER CONNECTION HOSES (UL) PRODUCT FEATURES (UL Approved) Hose Type Standard corrugated metal hose Pressure Rating : 175 psi Hose Material Stainless Steel AISI 16L Max. Ambient Temperature : 00 F Braiding Material Stainless Steel AISI 04 Flexibility Type : Limited Fittings Types Inlet 1 Male Intended System Type : Wet and Dry Fittings Materials Min. Bending Radius Max. Span Outlet 1/2 Female Galvanized Coated Carbon Steel St.7.2 200mm 610 mm (24 in.) Largest K-Factor : 5,6 * Intend use for direct connection to fire sprinkler * These products can be used accordance with NFPA 1, 1D and 1R standards. HOSE DIMENSIONS (UL Approved) LENGTH CONNECTION DN (with fittings) Main Pipeline Sprinkler (mm) (ft) 500 1.6 700 2. 20 DN20 (1 ) x 1/2 1000. 1200.9 1500 4.9 1800 5.9 Max. No. of 90 Bends 1 2 Equivalent Length of 1 in. Schedule 40 Steel Pipe (C = 120), ft 15 26 9 45 5 68 1 5 4 2 Ceiling Specifications These connections are designed for using in ceilings tile grids that meet ASTM C 65 and ASTM C 66 referenced by the IBC. Light-Duty Systems, Intermediate-Duty Systems and Heavy-Duty Systems are structural classifications. These connections have been approved for using in all Intermediate-Duty and Heavy-Duty structural classifications. MATERIAL LIST Part Number Part Name Material 1 Assembly Bar Galvanized coated St 7.2 2 Fixing Bolt Carbon Steel 8.8 Kit Fixing Part Galvanized coated St 7.2 4 Sprinkler Hose Stainless Steel 5 Hose Fixing Part Galvanized coated St 7.2

INSTALLATION INSTRUCTIONS STEP 1 (Connecting the hose to the water line) The nipple side of the sprinkler hose is connected and tightened to the connection nut on the fire line. The conical nut thread provides proper sealing without using gasket. STEP 2 (Attaching the fixing parts to the metal grid) Two fixing parts are attached on both sides of the metal grid as them to face each other and gently tightened. Do not tighten too much in case further adjustments may be required. STEP (Placing the assembly bar) Slide the assembly bar through one of the fixing parts and push it to the opposite direction at the same plane until the unattended end of the bar goes through the hose fixing part and the opposite kit fixing part. Place the assembly bar as leaving equal distance at both sides and screw the bolt and gently tighten. STEP 4 (Tightening the sprinkler connection set) As the sprinkler connection set is complete and the sprinkler side is aligned with the hole on the ceiling. The bottom bolts of the fixing parts on both sides of the assembly bar are tightened. Tightening torque: 8N

INSTALLATION INSTRUCTIONS STEP 5 After fixing the nipple part, use Minimum Bend Radius Tool to be sure to bend the hose according to minimum bending radius. STEP 6 (Adjusting the sprinkler head s position) The bolts of hose fixing part on the assembly bar are loosen a little bit and the position of the hose outlet is adjusted as it fixed at the desired level according to the ceiling surface. Tighten the bolts back and complete the assembly. Tightening torque: 8N 8 n.m STEP 7 (Connecting the sprinkler head) The sprinkler head is connected to the sprinkler end of the hose and the escutcheon is tightened. The conical thread of the sprinkler head and the hose nut provide desired sealing with using no gaskets. STEP 8 After, completing the sprinkler hose assembly. The system must be tested in order to detect possible water leaks. Any leaks must be prevented immediately for maximum service life and protection against the hazards.

HEAD OFFICE - FACTORY Atatürk Sanayi Bölgesi Hadımköy Mahallesi Mustafa İnan Caddesi No: 44 Arnavutköy - İSTANBUL Tel: +90 212 771 01 45 (pbx) Fax: +90 212 771 25 60 Caserta/Italy Tel: +9 082 187 988 rmolaro@ayvaz.com Moscow/Russia Tel: +74959951728 ayvazrus@ayvaz.com Viernheim/Germany Tel: +49 6204601499 germany@ayvaz.com Kiev/Ukraine Tel: +80 44 90 57 57 info@ayvaz.com.ua Warsaw/Poland Tel: +48-2-78-295-1 tricorr@tricorr.eu Dubai/U.A.E Tel: +971 56550822 +971 50106871 mideast@ayvaz.com Xiamen/China Tel: +86 592-7018050 shanghai@ayvazchina.com xiamen@ayvazchina.com Kazakhstan Tel: +7 (701) 066 066 1 +90 (5) 760 4 66 celyas@ayvaz.com Isperih/Bulgaria Tel: +59 841 27 2 office@ayvaz-n.eu info@ayvaz.com www.ayvaz.com