Filtration Equipment /Accessories : our weblinks

Similar documents
Titan3 Syringe Filters. Sample Preparation 1-036

filtration at its finest Thermo Scientific Nalgene Syringe Filters

Thermo Scientific Nalgene Rapid-Flow Filters. the last line of defense. against contamination

Minisart Syringe Filters

filtration The last line of defense against contamination. For more information visit:

Innovative New Products

9 LABORATORY ACCESSORY

Introduction TEFLON PFA Filtration

Plastic and Glass Storage Bottles. Product Selection Guide

Plastic and Glass Storage Bottles. Product Selection Guide

Your cells deserve the best

25 mm Glass Holder for the Filtration of Small Volumes mm Glass Holder with Protective PTFE Ring 49. All-glass Holder 50

Lenntech Tel Fax

Process Filtration From Pure to Sterile

BOTTLE CAPS & CONNECTION SYSTEMS

BOTTLE CAPS & CONNECTION SYSTEMS

INFUSION TUBES STANDARD INFUSETTE TUBES

Capacity (ml) Ø (mm) Height (mm) Cap Packed Pk Cat. No Blue cap bulk V White cap bulk V 125

Sartopure GF Plus The depth filter for adsorptive retention

ASXPRESS PLUS Rapid Sample Introduction System

QuantX Fluid Management. QuantX - DCK800 Dispensing Component Kit

The 15QQ series is a unique and versatile peristaltic pump range designed for accurate dispensing of liquids.

Single, oversized roller compresses a low friction hose through a full 360-degree rotation

HOSE ASSEMBLY CLEANLINESS

Flomax (pp) Description. Application. Feature & Benefits. Specifications. Woongjin Chemical CSM _ Pleated Cartridge Filter

high performance pipettors Excellence and precision for all your liquid handling procedures.

Premium Syringe Filters

DECONTAMINATION TENTS, SHOWERS, BASINS

TRANSFER PIPETS. transfer of liquids. Designed for the safe and convenient. transfer of liquids. Includes 52 NEW sterile pipets!

Cell Culture Research Consumables

Spray Adhesives Equipment. Dispensing Equipment for Bulk Sprayable Adhesives

Cell Strainers. CELLTREAT Table of Contents S N R/D F NP USP A ABS GLS HDPE PC PETG PP PS TPE

THE DURAN LABORATORY BOTTLE SYSTEM

Corning Aspirator Instruction Manual

Aspirators & Accessories Phantom HYBRID

Old-Style Aging Cell 316 Stainless Steel mL Capacity. Part No Instruction Manual. Updated 8/21/2014 Ver. 1.7

A Culture of Service. C ontainer L ibr ary. Container Library Section U

General Laborator. Beakers, Low Form. Beakers, Low Form. Beaker Cups, Disposable Consumables General Plasticware

Upchurch LOW PRESSURE FITTINGS AND CONNECTORS

Saw Blade Lube Systems

GASTRO-INTESTINAL (ENTERAL)

SimpleMix. 16 oz, 1 Gallon, and 200 L SimpleMix System

Visit us at 5170 N 125th St. Butler WI or online at 197

Realax hoses & tubes specification. Fitted for the purpose

VWR CARBOYS. Feature Versatile Cap Technology. Autoclavable. Shape maximizes bench and shelf space

AMS Gas Vapor Probe Systems (GVP)

EcON-O-fit HOSE clamps

RV 10 Rotary Evaporators

STERILIZATION and PREPARATION

SEDIMENT SAMP. SLUDGE & SEDIMENT SAMPLING. Drum & Tank Samplers Sludge/Sediment Core Profiler Sediment Dredge Sediment Sampler

Essentials. Top Selling Laboratory. Lennox. One source for all your laboratory needs. 20% OFF* 20% OFF* 15% OFF* 20% OFF* 25% OFF*

Funnels And Filters. table-top Buchner Funnels. Buchner table-top Funnels. (866) Filter Large Volumes Quickly

UNODOS + / FLOCDOS +

REUSABLE ALUMINUM SWIVEL FITTINGS REUSABLE ALUMINUM LIGHTWEIGHT CRIMP SWIVEL FITTINGS OTHER REUSABLE ALUMINUM FITTINGS SOCKETLESS HOSE

Product Code: LC8082/EUK. Description: MinFlexiNeck Mag light. Features & Benefit:

1250ul Extra Long Pipet Tips (Sterile, Non-Filtered) in 6 hinged racks $18.50

Waterfed Pole Cleaning

PRECISION LIQUID HANDLING SYSTEMS

QUOTATION REQUEST FORM

SmartMoveES#12-E 1/10/07 3:41 pm Page 1 NALGENE SMART MOVE. Buy 4 pay for 3! You can t beat NALGENE quality. Sterile and non-sterile

COLIFORM BROTH. Fecal Coliform Broth. M-FC BROTH without ROSOLIC ACID (Blue background)

OASIS DP SANIC RO. Reverse Osmosis Units with Made in Italy components. Keep your filters protected with silver based Antimicrobial Technology

Proven quality and selection with unparalleled support.

Cold Water Rheology Kit

This protocol is designed for the isolation of 96 plasmid DNA samples from 1.3ml bacterial cultures. Yield is up to 6µg.

General Plumbing. Section L Contents

TUBING PLEASE READ. Tubing for Samplers with Peristaltic Pumps

FBO-10 and FBO-14. Fuel Filter/Water Separator For High-Flow Applications. Product Features. Contact Information

Parts and Accessories for Dispenser

EASY TO USE. Passionately enabling chemists to create a better world since From A to Z. ROTARY EVAPORATORS MADE BY IKA.

HAND-HELD PNEUMATIC GUN VACS FROM GUARDAIR Serious cleaning power in the palm of your hand

Inventory List UT Austin

Industrial Vacuum Accessories

The squeezable liquid transport tube for outdoors, travel, personal care and much more

Mixpac TM B-System Application System for 2-Component Products 25 ml, 50 ml and 75 ml

SAWYER DUAL BLADDER GRAVITY SYSTEM User s Guide

200-BP-CAL-KIT. Sphygmomanometer Calibration Kit INSTRUCTION MANUAL

Big SHOT III Hybridization Oven

Quality Consistency Reliability.

DURAN GROUP DISPENSER. Safe and precise dispensing system

Evaluation copy. Fecal Coliform. Computer INTRODUCTION

WE ARE MANUFACTURER!

CARTRIDGE AND BAG FILTER UNIT. Passion for Filtration

Selecting Marine Hoses

Water Filtration System

BAG-TO-BAG FILTER KIT FILTERED UNFILTERED GRN LINE WATER FLOW. USER MANUAL Model Number EPA Est. No UT-001

Filtration Product Catalog

Flow Splitter. Installation Instructions

Uthleber Weg Nordhausen Germany

Terminology 1/25/2015. Alharith Hassan U of K 1

Pressure relief valve VRH 5 / VRH 30 / VRH 60 / VRH 120

Pressure relief valve VRH 5 / VRH 30 / VRH 60 / VRH 120

CONTENTS. Specifications of all products mentioned are indicative only

Lab Equipment. Chemistry Willowridge High School Mr. L Moore

Introducing EXP. the new gold standard of extreme pressure chromatography hardware and consumables.

BEAKERS MEASURING JUGS FISHER CLAMP FISHER CLAMP ANALYTICAL FUNNELNALYTICAL FUNNEL

IMPORTANT OWNER-OPERATOR INSTALLATION INSTRUCTIONS C2204A

FINE INSTRUMENTS AND EQUIPMENT FOR FAT GRAFTING & LIPOPLASTY

XForce. Heavy-Duty Cordless Airless Sprayer Optimized for Protective and Marine Coatings

LP Grill and Gas Hose

Transcription:

Filtration Equipment /Accessories : our weblinks PRODUCT LIST short form List Plastic Syringes Norm-Ject Syringe Filters Membrane Filters Membrane Solutions Glass Filtration Systems BottleTop Filtration Vac-uFill Vacu-CAP /FAST Caps Pumps : Vacuum Pumps Hand Vac Pump Motorised Vac Pump Dispensing Syringe & Peristaltic Pumps New Era Syringe Heater Kit Syringe Dispensers MicroLIT Double Check Valves ValuePlastics Single-Step MicroFILTRATION Thomson > RESTEK 1

Glass Filtration Equipment Oils (???) : Thin Oils or Aqueous-based Motorised pumps run continuosly 0.45um 1ml/min Use internal collection Test Tube Syringe Pump + Barrel heater Oils : 60ccSyringe 0.45um SF Syringe Heater @ 55degC 0.45um 25mm > 5ml/min New 33mm SFs 1.75x faster 8cc/min Heat to 55degC 2x faster 16cc/Min Syringe Dispenser 10ml Only Extra leverage helps Thin Oils or Solvents/Aqueous See Double CheckValve (can be problematic with sticky oils???) 2

BottleTop Filtration 2 Systems... PALL Vacu-Cap and Nalgene FastCap Similsr specs Availability... both from Chromtech depends on Supplier Availability The PALL VacuCap Filter is used for sterilization or clarification of a wide variety of fluids. use for cell culture and serum-containing media liquids have a Supor (hydrophilic PES polyethersulfone) membrane which provides fast flow rates. can draw directly from mix vessel and filters directly into the desired containers, minimizing transfer steps. accepts a variety of collection vessels. VacuCap 90 Filter which is designed for volumes of 1 5L have built-in prefilter that increases throughput of viscous or particulate solutions, such as serum-containing media. Polyester membrane support. Acrylic housing. VacuCap Filters are Sterile. come with one piece of tubing per ten filter devices. The feedline accessory kit includes tubing and a glass sinker. How They WORK use with Hand Vacuum Pump MityVac 12-MV8010 $135 use with Motorised Vacuum Pump VPJ0332 $535 VacuCap 90 90mm Diam Cap VC-4621 0.1um for critical sterilisation $375 10-pk VC-4622 0.2umfor sterilisation $350 Sterile/Fast VC-4623 0.45um $350 1-5Liter volumes... Simple Glassware Accessory use The Nalgene Fastcap Filter works on any bottle that has a neck opening of up to 53mm. The Nalgene FastCap Filter eliminates the need to use threaded glass media bottles. Place a Nalgene FastCap filter on bottle mouth, attach a vacuum line to the larger center vaccum hose link and your liquid media tube to the smaller tube link and start filtering. The Nalgene FastCap... filters up to 5 liters of liquid. Housing is blue polystyrene; the 90mm filter is made of PES (polyetheresulfone) with a 0.2um pore diameter. Each filter is packaged in individual hermetically sealed plastic bags. Nalgene FastCap filters are STERILE (gamma radiation sterilized). Nalgene FastCap filters are sold in individual units or a case of 10 VacuCap and Fast Cap are very similar in principle ( supply and demand determine Supplier and Chromtech Stock at any time) Accessory Glassware also available form Chromalytic - Enquire! see Glassware 3

Filtration Accessories : Filtration Hints Selection of Filter Media : by size Flow propl to (Diam) sqrd Vac-u-Fill Bottles VacuCap fastfiltration(pall) FastCap(Nalgene) 0.45um : 0.22um 1.00 : 0.25 x speed Liquid Dispensers Syringe Pump Syringe Filter : max Pressure 72psi (PP body ) Hand Vacuum Pump on top of main filter Pre Filter : protects main filter from blocking extends lifetime and can improve speed use coarser Glass Fibre some have Class Fibre Multi-Layer on top of main filter Relative speed based on Surface Area of Pore Size um 13 : 25 : 33mm 0.27 : 1.0 : 1.75 x speed Measured Syringe Pump : Olive Oil 25C 30psi (PressGauge) 20ml 19mmID Syringe 0.5sqin > 1.0ml/min 50ml syringe 29mmID > 2.3ml/min Vacuum vs Pressure HandPump Vacuum 350mm = - 7.0psi max developed Vac Flask Filtration Syringe Filter 25mmD Thumb Force ~10lb max = 20psi ( but RSI problems???) 47mm 25mm 47mm MF Calculated Flow=0,66ml/min x { 47/25 }sqd = x 3.5 -= 2.30ml/min Measured 20ml/6.0min = 3.3ml/min Olive Oil Viscosity 43cps 37C 24cps 54C Flow is propl to 1/ viscosity heating speeds up flow ALL filters tend to block up depending on particulates that actually tend to fill the filter pores - use of coarser pre-filter (glass Fibre) helps speed and the total sample throughput for best results - match the polarity of the Membrane material with the polarity of the liquid hydrophillic : PES > Nylon > PVDF > PTFE Hydrophobic water-based polar solvents polyester Oils Hydrocarbon-based Oils these are but generalisations - & it s very much trial and error for each application 4

Typical Filtration PRODUCT LIST prices as per June 2014 XR AUD/USD=0.94 Norm-Ject Syringes Plastic Syringes All PP; Robust : LuerLok and Slip in 1ml, 3ml, 5ml, 10ml, 20ml, 30,ml, 50ml AUD 22766 22773 22775 22776 22777 22778 Normject Plastic Syringes 1ml Tuberculin; Slip; 100-pk Normject Plastic Syringes 3ml; LuerLok; 100-pk Normject Plastic Syringes 5ml; LuerLok; 100-pk Normject Plastic Syringes 10ml; LuerLok; 100-pk Normject Plastic Syringes 30ml; LuerLok; 50-pk Normject Plastic Syringes 50ml; LuerLok; 30-pk 48.00 56.00 88.00 56.00 78.00 78.00 Syringe Filters SF/MAT/Diam/PoreuM MAT = PTFE, PVDF, PolyProp, Nylon, PES, 25mmD ;100-pk (also 13mm) SFPVFD025022N SFPVDF025022NG SFPVDF025045SM 0.22um (or 0.45um, non-sterile) Nonsterile PVDF Syringe Filters 0.22(um) 25(mm) GF prefilter Sterile G-MP Multi Layer PVDF 25mm 0.45um 1-/7/1/0.45um 96.00 169.00 195.00 6900-2502 6900-2504 Whatman GD/X : Sterile PVDF 0.22um multilayer. 25mm Whatman GD/X : Sterile PVDF 0.45um multilayer, 25mm Membrane Filters MF/MAT/Diam/PoreuM MAT = PVDF, PolyProp, Nylon, PES; GlassFiber MFPVDF047022N MFGF047100B 0.22um or 0.45um; 47mmDiam; 200-pk Glass Fiber Membrane Filter With Binder 1.00(um) 47(mm) 420.00 420.00 139.00 48.00 12-MV8010 Vacuum Pump : Hand Pump MityVAC 135.00 VPJ0332 Vacuum Pump /Motorised : Diaphram 220VAC; 300mmHg 20L/Min 535.00 Filtration Systems : use separate MFs on top as needed VFG030010 GlassFiltration System 47mm MF, Frit, Clamp, 300mlFunnel; 000ccBottle 295.00 VFPPVDF145250 VFPPVDF222500 Cap Filtration PES, PVDF (also MCE, CA, Nylon) Vac-uFill 47mmD, 250mlFunnel/250ml Bottle;10-pk Vac-uFill 90mmD, 1.8umGF preflter; 500mlFunnel/500ml Bottle, 10-pk Vac-uCap, = Nalgene FAST Cap 198.00 360.00 CT-4622 VacuCAP;Pall; Filter 90mm/10pk Hydrophillic PES 0.2um; 10-pk 368.00 Liquid Pumps NE-300AS NE-1000AS Heater-Kit-1LG NE-9000AS SyringePump Infusion Only NE-300AS Syringe Pump Programmable NE-1000AS Syringe Heater Kit ; PAD/controller & 120V 33W heating; inc transformer Peristaltic Pump ( Low Pressure Dispensing) NE-9000AS Bottle Top Dispensers : also.5, 5.9. 10. 50, 50ml Max 465.00 825.00 545.00 725.00 BTDR-3 Microlit BottleTop Dispense 0.5to10ml Research Grade 215.00 Syringe Dispenser CT-FDS-10 C-4004 DCV115-001 10ml SyringeDispenser Gun (Sterile) 10ml Spring-loaded Syringe DoubleCheck Valve, Tubing Chimney Port RLL Exit CP2-5 Microfiltration : SingleStep Filtration; 200-pk Nylon; PES, PVDF, PTFE 0.2um, 0.45um 45.00 18.00 3.95 23964 23960 0.45um PES Ask for current prices - Only part of Complete Filtration Products 648.00 648.00 5