B-300 series Jameco SKU Number: 2102035 (except for 48V) ( type only) B 300/360 12 1.300W without FAN 2.360W with FAN :With assive FC N:Without assive FC 12:14.4V 24:28.8V 48:57.6V SECIFICATION MODEL OUTUT INUT ROTECTION FUNCTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE BOOST CHARGE VOLTAGE FLOAT CHARGE VOLTAGE VOLTAGE ADJUSTABLE RANGE 13 ~ 14.7V RECOMMENDED BATTERY 80 ~ 200Ah CAACITY(AM HOURS)(Note 5) BATTERY TYE OUTUT CURRENT(max.) CONTINUOUS OUTUT 12.5A CURRENT (Typ.) (Note 6) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) OWER FACTOR (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD SHORT CIRCUIT REVERSE OLARITY OVER VOLTAGE OVER TEMERATURE REMOTE CONTROL (CN5) WORKING TEM. WORKING HUMIDITY STORAGE TEM., HUMIDITY TEM. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY B-300-12 B-300-24 14.4V 28.8V 13.6V Open & Sealed Lead Acid 20.85A 27.2V 26 ~ 28.8V 40 ~ 125Ah 10.5A 6.25A 90 ~ 132VAC / 180 ~ 264VAC selected by switch 248 ~ 370VDC 47 ~ 63Hz 85% >0.65 (with type) at 230VAC 6A/115VAC 3A/230VAC COLD START 60A <3.5mA / 240VAC 90 ~ 110% rated output current rotection type : Constant current limiting, recovers automatically after fault condition is removed O/ Built in fuse (FS100) to protect short circuit condition, shut down o/p voltage and can not re-power on By internal fuse rotection type : Shut down o/p voltage, re-power on to recover rotection type : Automatically derate charge current until zero Open: Normal work Short: Stop Charging -10 ~ +50 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.05%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes IEC60335-2-29 CB approved by TUV(except for 48V), UL60950-1 approved I/-O/:3KVAC I/-FG:1.5KVAC O/-FG:0.5KVAC I/-O/, I/-FG, O/-FG:100M Ohms / 500VDC / 25 Compliance to EN55022 (CISR22) Class B Compliance to EN61000-3-2,-3 (only type) / 70% RH Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 115.8Khrs min. MIL-HDBK-217F (25 ) DIMENSION ACKING 253*135*48.5mm(L*W*H) 1.45Kg; 6pcs/9.7Kg/0.95CUFT 86% 16 ~ 18V 31 ~ 35V B-300-48 57.6V 54.4V 52 ~ 58.6V 20 ~ 65Ah 5.3A 3.2A 88% 59 ~ 64V File Name:B-300-SEC 2008-11-11
Jameco SKU B-300 Number: 2102035 series Mechanical Specification Case No.801B Unit:mm 253 235 12 127 54 48.5 5.5 LED 9.25 9.75 INLET ON/OFF SWITCH -V +V 11 230 SVR1 1 2 CN5 Air flow direction 135 Remote Control(CN5) : JST B2B-XH or equivalent Assignment IN1,2 Open: Normal work IN1,2 Short: Stop Charging Mating Housing JST XH or equivalent Terminal JST SXH-001T-0.6 or equivalent Block Diagram FAN ON/OFF CONTROL fosc : 70KHz I/ EMI FILTER RECTIFIERS & ASSIVE.F.C. OWER SWITCHING RECTIFIERS & FILTER O.C.. OLARITY REVERSE ROTECTION +V -V FG O.L.. WM CONTROL DETECTION CIRCUIT O.V.. Charging Curve Output Load VS Temperature Start Vboost 100 Charge Voltage VFLT 100% 90 80 70 Charge Current Constant Current Constant Voltage stage 1 stage 2 stage 3 LOAD (%) 60 40 30 LED COLOR Red Green -10 0 10 20 25 30 40 50 60 State B-300-12 Vboost 14.4V B-300-24 B-300-48 28.8V 57.6V VFLT 13.6V 27.2V 54.4V EXTERNAL CASE TEMERATURE ( ) File Name:B-300-SEC 2008-11-11
B-300 series MODEL:B-300-24 OUTUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 BOOST CHARGE VOLTAGE 28.8V (+0.3V) I/: 230 VAC I/: 115 VAC O/:90% LOAD 28.69 V/ 230 VAC 28.69 V/ 115 VAC 2 FLOAT CHARGE VOLTAGE 27.1V~27.3V I/: 230 VAC I/: 115 VAC O/: N0 LOAD 27.23 V/ 230 VAC 27.23 V/ 115 VAC 3 OUTUT VOLTAGE ADJUST RANGE CH1: 26V~ 28.8V I/: 230 VAC I/: 115 VAC O/:NO LOAD 25.08 V~ 30.3 V/ 230 VAC 24.98 V~ 30 V/ 115 VAC INUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 INUT VOLTAGE RANGE 180VAC~264 VAC) I/:TESTING O/: 90% LOAD I/: LOW-LINE-3V= 177 V HIGH-LINE+15%=300 V O/: 90% LOAD /MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF NO DAMAGE ) 138 V~264V TEST: OK 2 INUT FREQUENCY RANGE 47HZ ~63 HZ NO DAMAGE OSC I/: 180VAC ~ 264 VAC O/: 90% LOAD ~MIN LOAD TEST: OK 3 OWER FACTOR 0.65 / 230 VAC (TY) I/: 230 VAC F= 0.76 / 230 VAC O/: 90% LOAD 4 EFFICIENCY 86 % (TY) I/: 230 VAC 5 INUT CURRENT O/: 90% LOAD 88.7 % 230V/ 3 A (TY) I/: 230 VAC I = 1.8 A/ 230 VAC 115V/ 6 A(TY) I/: 115 VAC O/: 90% LOAD I = 4.6 A/ 115 VAC 6 INRUSH CURRENT 230V/ 60 A (TY) I/: 230 VAC I = 55 A/ 230 VAC COLD START O/: 90% LOAD 7 LEAKAGE CURRENT < 3.5 ma / 240 VAC I/: 254 VAC O/:Min LOAD L-FG: 1.1 ma N-FG: 1.1 ma Model: B-300-24 Test Report 1 / 4
B-300 series ROTECTION FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 OVER LOAD ROTECTION 90 %~ 110 % I/: 230 VAC I/: 115 VAC O/:TESTING 100 %/ 230 VAC 100 %/ 115 VAC Constant Current Limiting 2 OVER VOLTAGE ROTECTION CH1: 30V~ 35V I/: 230 VAC I/: 115 VAC O/:MIN LOAD 33.2 V/ 230 VAC 33.2 V/ 115 VAC Shunt down Re- power ON 3 OVER TEMERATURE ROTECTION Automatically derate charge I/: 230 VAC O.T.. Active current until zero O/: 90% LOAD Automatically derate charge current until zero 4 REVERSE OLARITY BY internal fuse I/: 230 VAC CONTROL FUNCTION TEST Fuse open NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 FAN ON/OFF CONTROL ANO LED TEST 2 REMOTE CONTROL (CN5) OEN : Normal work ENVIRONMENT TEST ------- I/: 230 VAC O/:TESTING Short : Stop charging I/: 230 VAC O/: BAT 190AH < 0.35 A LED:GREEN > 0.4 A LED:RED OEN : Normal work Short : Stop charging NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 TEMERATURE RISE TEST MODEL:B-300-12 1. HIGH AMBIENT BURN-IN:15HRS 2 LOW TEMERATURE TURN ON TEST 3 HIGH HUMIDITY HIGH TEMERATURE HIGH VOLTAGE TURN ON TEST 4 TEMERATURE COEFFICIENT I/: 230VAC O/: BAT 190AH CASE= 30.8 2. HIGH AMBIENT BURN-IN:7HRS I/: 264VAC O/: BAT 190AH CASE = 39.7 3. HIGH AMBIENT BURN-IN:15HRS I/: 180VAC O/: BAT 190AH CASE = 42.5 4. HIGH AMBIENT BURN-IN:7HRS I/: 132VAC O/: BAT 190AH CASE = 31.4 5. HIGH AMBIENT BURN-IN:17HRS I/: 90VAC O/: BAT 190AH CASE = 37 TURN ON AFTER 2 HOUR I/: 230 VAC O/: BAT 190AH CASE= -10 AFTER 12 HOURS I/: 272 VAC IN CHAMBER ON O/: 90% LOAD CONTROL 25 Ta= 25 NO DAMAGE HUMIDITY= 95 %R.H + 0.05 %(0~50 ) I/: 230 VAC O/: BAT 190AH TEST:OK TEST:OK + 0.02 %(0~50 ) p 5 VIBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) TEST:OK Model: B-300-24 Test Report 2 / 4
B-300 series SAFETY TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 WITHSTAND VOLTAGE I/-O/: 3 KVAC/min I/-FG: 1.5 KVAC/min O/-FG: 0.5 KVAC/min I/-O/: 3.6 KVAC/min I/-FG: 1.8 KVAC/min O/-FG: 0.6 KVAC/min I/-O/: 11.04 ma I/-FG: 9.38 ma O/-FG: 12.89 ma NO DAMAGE 2 ISOLATION RESISTANCE I/-O/:500VDC>100MΩ I/-FG: 500VDC>100MΩ O/-FG:500VDC>100MΩ I/-O/: 500 VDC I/-FG: 500 VDC O/-FG: 500 VDC I/-O/: 2 GΩ I/-FG: 3 GΩ O/-FG: 3 GΩ NO DAMAGE 3 GROUNDING CONTINUITY FG(E) TO CHASSIS OR TRACE < 100 mω 40 A / 2min 11 mω E.M.C TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 HARMONIC EN61000-3-2 CLASS A I/: 230 VAC/50HZ O/: 90% LOAD ASS 2 CONDUCTION EN55022 CLASS B I/: 230 VAC (50HZ) O/: 90% LOAD /50% LOAD ASS Test by certified Lab 3 RADIATION EN55022 CLASS B I/: 230 VAC (50HZ) O/: 90% LOAD ASS Test by certified Lab 4 E.S.D EN61000-4-2 LIGHT INDUSTRY AIR:8KV / Contact:4KV I/: 230 VAC/50HZ O/: 90% LOAD CRITERIA A 5 E.F.T EN61000-4-4 LIGHT INDUSTRY INUT: 1KV I/: 230 VAC/50HZ O/: 90% LOAD CRITERIA A 6 SURGE IEC61000-4-5 LIGHT INDUSTRY L-N :1KV L,N-E:2KV I/: 230 VAC/50HZ O/: 90% LOAD CRITERIA A 7 Test by certified Lab & Test Report repare M.T.B.F & LIFE CYCLE CALCULATION NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 CAACITOR LIFE CYCLE SUOSE C104 IS THE MOST CRITICAL COMONENT I/: 230VAC O/: 90% LOAD CASE= 25 LIFE TIME= 1373958 HRS I/: 230VAC O/: 75% LOAD CASE= 50 LIFE TIME= 307095 HRS 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 115.8KHRS Model: B-300-24 Test Report 3 / 4
B-300 series COMONENT STRESS TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 ower Transistor ( D to S) or (C to E) eak Voltage Q 2 Rated 2SK2850 : 900V 2 Diode eak Voltage D102 Rated 6A SF20LC30 : 300V 20 A 3 Clamp Diode eak Voltage D2 Rated SF5408 : 1KV 3A I/:High-Line +3V = 267 V O/: (1) 90% LOAD Turn on (2) 90% LOAD (3)Output Short I/:High-Line +3V = 267 V O/: (1) 90% LOAD Turn on (2) 90% LOAD (3)Output Short I/:High-Line +3V = 267 V O/: (1) 90% LOAD (1) 820 V (2) 695 V (3) 810 V (1) 219 V (2) 214 V (3) 224 V (1) 735 V 4 Input Capacitor Voltage C5 Rated :470 u / 200V/105 I/:High-Line +3V = 267 V O/: (1) 90% LOAD Turn on /Off (2) Min load Turn on /Off (3) 90% /Min load Change (4)Burn in 1hour (1) 160 V (2) 173 V (3) 173 V (4) 160 V 5 Control IC Voltage Test U1 Rated 3845 : 30V I/:High-Line +3V = 267 V O/: (1) 90% LOAD Turn on /Off (2) Min load Turn on /Off (3) 90% /Min load Change (1) 19.4 V (2) 19.3 V (3) 19.4 V DATE SAMLE TEST RESULT TESTER AROVAL 2005/11/30 RD SMALE ASS VINCENT TSENG MAX LIN 2006/6/22 2006/8/11 RODUCT SAMLE W0604B27 RODUCT SAMLE W0607B40 ASS VINCENT TSENG MAX LIN ASS VINCENT TSENG MAX LIN 2003/12/12 A50-F023 Model: B-300-24 Test Report 4 / 4