PB 300/360 P 12 PB PB V 28.8V 13.6V 27.2V 26 ~ 28.8V. 40 ~ 125Ah 10.5A 6.25A

Similar documents
320W Single Output with PFC Function

CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection



1000W Intelligent Single Output Battery Charger MODEL:PB OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT.

240W Single Output with PFC Function

62.5W Rated output power for convection; 80W with 18CFM min. forced air

Jameco SKU Number:

50W Single Output Switching Power Supply

60W Single Output LED Power Supply

60W Single Output Switching Power Supply



35W Single Output Switching Power Supply

60W Single Output Switching Power Supply

120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

Jameco SKU Number:

600W with PFC and Parallel Function PSP-600 series

Test Report: EDR-75-12

15W Single Output Switching Power Supply MODEL:RS OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

MODEL:RT-65B OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT I/P: 230 VAC O/P:FULL LOAD

75W Single Output with PFC Function

60W Single Output LED Power Supply MODEL:PLP OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

1000W Single Output Power Supply

1000W Single Output Power Supply

LPS 20V 24V. COLD START 40A(t width=1030 s measured at 50% I peak) <0.75mA / 240VAC

20W Single Output Switching Power Supply MODEL:LPV OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT O/P:FULL LOAD

Test Report: EPP

Test Report: EPP

IP65 IP67 MODEL CLG CLG CLG CLG CLG CLG CLG V 15 ~ 20V 24V 18 ~ 24V

Test Report: EPS 15 12

MODEL CEN CEN CEN CEN CEN CEN CEN V 24V 30V 36V 42V

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST

Test Report: GSM40A18

Test Report: APC

Test Report: IRM-05-05

Test Report: HB

Test Report: IRM-20-24

Test Report: IRM-05-24

Test Report: IRM-10-12

Test Report: HEP


20W Single Output Industrial DIN Rail Power Supply MODEL:MDR OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT





Test Report: LCM 60DA




Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Model Number Structure

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

General Purpose High Power PCB Relays

General-Use Auto-Tuning HPX-T Series

Model Number Structure

General-purpose Relay

Plug-in/solder terminals with LED indicator

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Electrical Specifications. Input range Vac (Operating) 115/230 Vac (Nominal) Internal fuse on both L and N lines.

Feature. Model comment JG 3NA B L - B - D3

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

SWL Series VALVE REGULATED LEAD-ACID BATTERIES SWL

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

Limit Switches. 6.2 E47 Precision Switches

SPEDESTER Series QUICK REFERENCE GUIDE

Reliable high-power LED that gives you the design flexibility and performance you need

Model Crosspoint Matrix

Product Guide LED OBSTRUCTION LIGHTS

UNODOS + / FLOCDOS +

SPECIFICATION FOR LCD MODULE

CPFE1000Fi-48 EVALUATION DATA TDK-LAMBDA

Data Sheet for Precision Potentiometer

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

NK Multi-stage submersible pumps

Electronic Temperature Controls

LUXEON Rebel ES. Energy Saving

Product Specification

Data Sheet for Precision Potentiometer

Features Benefits Key Applications

Transcription:

B-300 series Jameco SKU Number: 2102035 (except for 48V) ( type only) B 300/360 12 1.300W without FAN 2.360W with FAN :With assive FC N:Without assive FC 12:14.4V 24:28.8V 48:57.6V SECIFICATION MODEL OUTUT INUT ROTECTION FUNCTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE BOOST CHARGE VOLTAGE FLOAT CHARGE VOLTAGE VOLTAGE ADJUSTABLE RANGE 13 ~ 14.7V RECOMMENDED BATTERY 80 ~ 200Ah CAACITY(AM HOURS)(Note 5) BATTERY TYE OUTUT CURRENT(max.) CONTINUOUS OUTUT 12.5A CURRENT (Typ.) (Note 6) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) OWER FACTOR (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD SHORT CIRCUIT REVERSE OLARITY OVER VOLTAGE OVER TEMERATURE REMOTE CONTROL (CN5) WORKING TEM. WORKING HUMIDITY STORAGE TEM., HUMIDITY TEM. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY B-300-12 B-300-24 14.4V 28.8V 13.6V Open & Sealed Lead Acid 20.85A 27.2V 26 ~ 28.8V 40 ~ 125Ah 10.5A 6.25A 90 ~ 132VAC / 180 ~ 264VAC selected by switch 248 ~ 370VDC 47 ~ 63Hz 85% >0.65 (with type) at 230VAC 6A/115VAC 3A/230VAC COLD START 60A <3.5mA / 240VAC 90 ~ 110% rated output current rotection type : Constant current limiting, recovers automatically after fault condition is removed O/ Built in fuse (FS100) to protect short circuit condition, shut down o/p voltage and can not re-power on By internal fuse rotection type : Shut down o/p voltage, re-power on to recover rotection type : Automatically derate charge current until zero Open: Normal work Short: Stop Charging -10 ~ +50 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.05%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes IEC60335-2-29 CB approved by TUV(except for 48V), UL60950-1 approved I/-O/:3KVAC I/-FG:1.5KVAC O/-FG:0.5KVAC I/-O/, I/-FG, O/-FG:100M Ohms / 500VDC / 25 Compliance to EN55022 (CISR22) Class B Compliance to EN61000-3-2,-3 (only type) / 70% RH Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 115.8Khrs min. MIL-HDBK-217F (25 ) DIMENSION ACKING 253*135*48.5mm(L*W*H) 1.45Kg; 6pcs/9.7Kg/0.95CUFT 86% 16 ~ 18V 31 ~ 35V B-300-48 57.6V 54.4V 52 ~ 58.6V 20 ~ 65Ah 5.3A 3.2A 88% 59 ~ 64V File Name:B-300-SEC 2008-11-11

Jameco SKU B-300 Number: 2102035 series Mechanical Specification Case No.801B Unit:mm 253 235 12 127 54 48.5 5.5 LED 9.25 9.75 INLET ON/OFF SWITCH -V +V 11 230 SVR1 1 2 CN5 Air flow direction 135 Remote Control(CN5) : JST B2B-XH or equivalent Assignment IN1,2 Open: Normal work IN1,2 Short: Stop Charging Mating Housing JST XH or equivalent Terminal JST SXH-001T-0.6 or equivalent Block Diagram FAN ON/OFF CONTROL fosc : 70KHz I/ EMI FILTER RECTIFIERS & ASSIVE.F.C. OWER SWITCHING RECTIFIERS & FILTER O.C.. OLARITY REVERSE ROTECTION +V -V FG O.L.. WM CONTROL DETECTION CIRCUIT O.V.. Charging Curve Output Load VS Temperature Start Vboost 100 Charge Voltage VFLT 100% 90 80 70 Charge Current Constant Current Constant Voltage stage 1 stage 2 stage 3 LOAD (%) 60 40 30 LED COLOR Red Green -10 0 10 20 25 30 40 50 60 State B-300-12 Vboost 14.4V B-300-24 B-300-48 28.8V 57.6V VFLT 13.6V 27.2V 54.4V EXTERNAL CASE TEMERATURE ( ) File Name:B-300-SEC 2008-11-11

B-300 series MODEL:B-300-24 OUTUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 BOOST CHARGE VOLTAGE 28.8V (+0.3V) I/: 230 VAC I/: 115 VAC O/:90% LOAD 28.69 V/ 230 VAC 28.69 V/ 115 VAC 2 FLOAT CHARGE VOLTAGE 27.1V~27.3V I/: 230 VAC I/: 115 VAC O/: N0 LOAD 27.23 V/ 230 VAC 27.23 V/ 115 VAC 3 OUTUT VOLTAGE ADJUST RANGE CH1: 26V~ 28.8V I/: 230 VAC I/: 115 VAC O/:NO LOAD 25.08 V~ 30.3 V/ 230 VAC 24.98 V~ 30 V/ 115 VAC INUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 INUT VOLTAGE RANGE 180VAC~264 VAC) I/:TESTING O/: 90% LOAD I/: LOW-LINE-3V= 177 V HIGH-LINE+15%=300 V O/: 90% LOAD /MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF NO DAMAGE ) 138 V~264V TEST: OK 2 INUT FREQUENCY RANGE 47HZ ~63 HZ NO DAMAGE OSC I/: 180VAC ~ 264 VAC O/: 90% LOAD ~MIN LOAD TEST: OK 3 OWER FACTOR 0.65 / 230 VAC (TY) I/: 230 VAC F= 0.76 / 230 VAC O/: 90% LOAD 4 EFFICIENCY 86 % (TY) I/: 230 VAC 5 INUT CURRENT O/: 90% LOAD 88.7 % 230V/ 3 A (TY) I/: 230 VAC I = 1.8 A/ 230 VAC 115V/ 6 A(TY) I/: 115 VAC O/: 90% LOAD I = 4.6 A/ 115 VAC 6 INRUSH CURRENT 230V/ 60 A (TY) I/: 230 VAC I = 55 A/ 230 VAC COLD START O/: 90% LOAD 7 LEAKAGE CURRENT < 3.5 ma / 240 VAC I/: 254 VAC O/:Min LOAD L-FG: 1.1 ma N-FG: 1.1 ma Model: B-300-24 Test Report 1 / 4

B-300 series ROTECTION FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 OVER LOAD ROTECTION 90 %~ 110 % I/: 230 VAC I/: 115 VAC O/:TESTING 100 %/ 230 VAC 100 %/ 115 VAC Constant Current Limiting 2 OVER VOLTAGE ROTECTION CH1: 30V~ 35V I/: 230 VAC I/: 115 VAC O/:MIN LOAD 33.2 V/ 230 VAC 33.2 V/ 115 VAC Shunt down Re- power ON 3 OVER TEMERATURE ROTECTION Automatically derate charge I/: 230 VAC O.T.. Active current until zero O/: 90% LOAD Automatically derate charge current until zero 4 REVERSE OLARITY BY internal fuse I/: 230 VAC CONTROL FUNCTION TEST Fuse open NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 FAN ON/OFF CONTROL ANO LED TEST 2 REMOTE CONTROL (CN5) OEN : Normal work ENVIRONMENT TEST ------- I/: 230 VAC O/:TESTING Short : Stop charging I/: 230 VAC O/: BAT 190AH < 0.35 A LED:GREEN > 0.4 A LED:RED OEN : Normal work Short : Stop charging NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 TEMERATURE RISE TEST MODEL:B-300-12 1. HIGH AMBIENT BURN-IN:15HRS 2 LOW TEMERATURE TURN ON TEST 3 HIGH HUMIDITY HIGH TEMERATURE HIGH VOLTAGE TURN ON TEST 4 TEMERATURE COEFFICIENT I/: 230VAC O/: BAT 190AH CASE= 30.8 2. HIGH AMBIENT BURN-IN:7HRS I/: 264VAC O/: BAT 190AH CASE = 39.7 3. HIGH AMBIENT BURN-IN:15HRS I/: 180VAC O/: BAT 190AH CASE = 42.5 4. HIGH AMBIENT BURN-IN:7HRS I/: 132VAC O/: BAT 190AH CASE = 31.4 5. HIGH AMBIENT BURN-IN:17HRS I/: 90VAC O/: BAT 190AH CASE = 37 TURN ON AFTER 2 HOUR I/: 230 VAC O/: BAT 190AH CASE= -10 AFTER 12 HOURS I/: 272 VAC IN CHAMBER ON O/: 90% LOAD CONTROL 25 Ta= 25 NO DAMAGE HUMIDITY= 95 %R.H + 0.05 %(0~50 ) I/: 230 VAC O/: BAT 190AH TEST:OK TEST:OK + 0.02 %(0~50 ) p 5 VIBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) TEST:OK Model: B-300-24 Test Report 2 / 4

B-300 series SAFETY TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 WITHSTAND VOLTAGE I/-O/: 3 KVAC/min I/-FG: 1.5 KVAC/min O/-FG: 0.5 KVAC/min I/-O/: 3.6 KVAC/min I/-FG: 1.8 KVAC/min O/-FG: 0.6 KVAC/min I/-O/: 11.04 ma I/-FG: 9.38 ma O/-FG: 12.89 ma NO DAMAGE 2 ISOLATION RESISTANCE I/-O/:500VDC>100MΩ I/-FG: 500VDC>100MΩ O/-FG:500VDC>100MΩ I/-O/: 500 VDC I/-FG: 500 VDC O/-FG: 500 VDC I/-O/: 2 GΩ I/-FG: 3 GΩ O/-FG: 3 GΩ NO DAMAGE 3 GROUNDING CONTINUITY FG(E) TO CHASSIS OR TRACE < 100 mω 40 A / 2min 11 mω E.M.C TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 HARMONIC EN61000-3-2 CLASS A I/: 230 VAC/50HZ O/: 90% LOAD ASS 2 CONDUCTION EN55022 CLASS B I/: 230 VAC (50HZ) O/: 90% LOAD /50% LOAD ASS Test by certified Lab 3 RADIATION EN55022 CLASS B I/: 230 VAC (50HZ) O/: 90% LOAD ASS Test by certified Lab 4 E.S.D EN61000-4-2 LIGHT INDUSTRY AIR:8KV / Contact:4KV I/: 230 VAC/50HZ O/: 90% LOAD CRITERIA A 5 E.F.T EN61000-4-4 LIGHT INDUSTRY INUT: 1KV I/: 230 VAC/50HZ O/: 90% LOAD CRITERIA A 6 SURGE IEC61000-4-5 LIGHT INDUSTRY L-N :1KV L,N-E:2KV I/: 230 VAC/50HZ O/: 90% LOAD CRITERIA A 7 Test by certified Lab & Test Report repare M.T.B.F & LIFE CYCLE CALCULATION NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 CAACITOR LIFE CYCLE SUOSE C104 IS THE MOST CRITICAL COMONENT I/: 230VAC O/: 90% LOAD CASE= 25 LIFE TIME= 1373958 HRS I/: 230VAC O/: 75% LOAD CASE= 50 LIFE TIME= 307095 HRS 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 115.8KHRS Model: B-300-24 Test Report 3 / 4

B-300 series COMONENT STRESS TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 ower Transistor ( D to S) or (C to E) eak Voltage Q 2 Rated 2SK2850 : 900V 2 Diode eak Voltage D102 Rated 6A SF20LC30 : 300V 20 A 3 Clamp Diode eak Voltage D2 Rated SF5408 : 1KV 3A I/:High-Line +3V = 267 V O/: (1) 90% LOAD Turn on (2) 90% LOAD (3)Output Short I/:High-Line +3V = 267 V O/: (1) 90% LOAD Turn on (2) 90% LOAD (3)Output Short I/:High-Line +3V = 267 V O/: (1) 90% LOAD (1) 820 V (2) 695 V (3) 810 V (1) 219 V (2) 214 V (3) 224 V (1) 735 V 4 Input Capacitor Voltage C5 Rated :470 u / 200V/105 I/:High-Line +3V = 267 V O/: (1) 90% LOAD Turn on /Off (2) Min load Turn on /Off (3) 90% /Min load Change (4)Burn in 1hour (1) 160 V (2) 173 V (3) 173 V (4) 160 V 5 Control IC Voltage Test U1 Rated 3845 : 30V I/:High-Line +3V = 267 V O/: (1) 90% LOAD Turn on /Off (2) Min load Turn on /Off (3) 90% /Min load Change (1) 19.4 V (2) 19.3 V (3) 19.4 V DATE SAMLE TEST RESULT TESTER AROVAL 2005/11/30 RD SMALE ASS VINCENT TSENG MAX LIN 2006/6/22 2006/8/11 RODUCT SAMLE W0604B27 RODUCT SAMLE W0607B40 ASS VINCENT TSENG MAX LIN ASS VINCENT TSENG MAX LIN 2003/12/12 A50-F023 Model: B-300-24 Test Report 4 / 4