Jameco SKU Number:

Similar documents
50W Single Output Switching Power Supply

62.5W Rated output power for convection; 80W with 18CFM min. forced air

320W Single Output with PFC Function


60W Single Output Switching Power Supply

CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection

60W Single Output Switching Power Supply


35W Single Output Switching Power Supply

Jameco SKU Number:

240W Single Output with PFC Function

60W Single Output LED Power Supply


15W Single Output Switching Power Supply MODEL:RS OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT


PB 300/360 P 12 PB PB V 28.8V 13.6V 27.2V 26 ~ 28.8V. 40 ~ 125Ah 10.5A 6.25A

120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

20W Single Output Switching Power Supply MODEL:LPV OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT O/P:FULL LOAD

600W with PFC and Parallel Function PSP-600 series

1000W Single Output Power Supply

MODEL:RT-65B OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT I/P: 230 VAC O/P:FULL LOAD

60W Single Output LED Power Supply MODEL:PLP OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

1000W Single Output Power Supply

Test Report: EDR-75-12

LPS 20V 24V. COLD START 40A(t width=1030 s measured at 50% I peak) <0.75mA / 240VAC

75W Single Output with PFC Function

Test Report: EPS 15 12

Test Report: EPP

IP65 IP67 MODEL CLG CLG CLG CLG CLG CLG CLG V 15 ~ 20V 24V 18 ~ 24V

Test Report: EPP

Test Report: GSM40A18

Test Report: IRM-05-05

Test Report: APC

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST

1000W Intelligent Single Output Battery Charger MODEL:PB OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT.

Test Report: IRM-10-12

Test Report: IRM-05-24

Test Report: HB

Test Report: IRM-20-24


MODEL CEN CEN CEN CEN CEN CEN CEN V 24V 30V 36V 42V




20W Single Output Industrial DIN Rail Power Supply MODEL:MDR OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT


Test Report: LCM 60DA

Test Report: HEP




Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Model Number Structure

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Plug-in/solder terminals with LED indicator

General-purpose Relay

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

General Purpose High Power PCB Relays

General-Use Auto-Tuning HPX-T Series

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Electrical Specifications. Input range Vac (Operating) 115/230 Vac (Nominal) Internal fuse on both L and N lines.

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

Feature. Model comment JG 3NA B L - B - D3

Model Number Structure

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

Introduction 2. Other Applicable Documents 2. Scope of Delivery 3. Attaching the Snap-on Ferrite Suppressor 4

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Electric Smoke Damper Actuators

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

Product Guide LED OBSTRUCTION LIGHTS

Dialight LED High Bay - High Output. Technical Specification Sheet - Americas

SPEDESTER Series QUICK REFERENCE GUIDE

DEUTSCH H91 Series Filter Connectors MIL-DTL SERIES I

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL

Type CGS High-Cap Screw Terminal Aluminum Electrolytic Capacitor

Reliable high-power LED that gives you the design flexibility and performance you need

SPECIFICATION FOR LCD MODULE

CPFE1000Fi-48 EVALUATION DATA TDK-LAMBDA

HEATER POWER CONTROLLER

NK Multi-stage submersible pumps

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

Data Sheet for Precision Potentiometer

Limit Switches. 6.2 E47 Precision Switches

Transcription:

Jameco SKU Number: 2106335 Single Output Medical Type RS-60 s e ries SECIFICATION MODEL RS-60-3.3 RS-60-5 RS-60-12 RS-60-15 RS-60-24 RS-60-48 OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC (Note 5) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED OWER EAK LOAD(10sec.) VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETU, RISE TIME HOLD U TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD OVER VOLTAGE WORKING TEM. WORKING HUMIDITY STORAGE TEM., HUMIDITY TEM. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE Note.4 36.3W 3.3V 5V 12V 15V 24V 48V 10A 10A 5A 4A 2.5A 1.25A 0 ~ 11A 0 ~ 11A 0 ~ 5.5A 0 ~ 4.4A 0 ~ 2.75A 0 ~ 1.375A 33W RILE & NOISE (max.) Note.2 80mVp-p VOLTAGE TOLERANCE Note.3 ISOLATION RESISTANCE EMI CONDUCTION & RADIATION 50W 55W HARMONIC CURRENT EMS IMMUNITY Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A MTBF 353.6Khrs min. MIL-HDBK-217F (25 ) DIMENSION 101.6*50.8*29mm (L*W*H) ACKING 0.15Kg; 96pcs/15.4Kg/0.89CUFT 80mVp-p 120mVp-p 150mVp-p 240mVp-p 300mVp-p 3.1 ~ 3.6V 4.75 ~ 5.5V 11.4 ~ 13.2V 13.5 ~ 16.5V 22.8 ~ 27.6V 45.6 ~ 52.8V 2.0% 2.0% 2.0% 500, 30/230VAC 50/230VAC 500, 30/115VAC at full load 13/115VAC at full load 90 ~ 264VAC 127 ~ 370VDC 47 ~ 63Hz 74% 79% 83% 84% 85% 86% 1.8A/115VAC 1 A/230VAC COLD START 60A/230VAC 30A/115VAC 3.8 ~ 5V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 28.4 ~ 32.4V 55.2 ~ 64.8V 2.0% 115 ~ 150% rated output power rotection type : Hiccup mode, recovers automatically after fault condition is removed -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes I/-O/, I/-FG, O/-FG:100M Oh/500VDC rotection type : Shut down o/p voltage, re-power on to recover Compliance to EN55011 (CISR11), EN55022 (CISR22) Class B UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved For earth <200uA / 264VAC, For patient <100uA/264VAC I/-O/:4KVAC I/-FG:1.5KVAC O/-FG:1.5KVAC EN60601-1 IEC60601-1 File Name:RS-60-SEC 2008-03-25

Jameco SKU Number: 2106335 Single Output Medical Type RS-60 s e ries Mechanical Specification Unit:mm 101.6 50.8 44.45 3.175 3 CN1 2 1 95.25 3.175 SVR1 CN2 1 2 3 4 4-3.3 3 max. 29 AC Input Connector (CN1) : JST B3-VH or equivalent in No. Assignment Mating Housing Terminal 1 AC/N JST VHR JST SVH-21T-1.1 2 No in or equivalent or equivalent 3 AC/L DC Output Connector (CN2) : JST B4-VH or equivalent in No. 1,2 3,4 Assignment +V -V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-1.1 or equivalent Block Diagram fosc : 100KHz I/ EMI FILTER RECTIFIERS & FILTER OWER SWITCHING RECTIFIERS & FILTER +V -V FG O.L.. CONTROL DETECTION CIRCUIT O.V.. Output Derating Output Derating VS Input Voltage Ta=25 100 100 90 80 80 60 70 LOAD (%) 40 20 LOAD (%) 60 50 40-20 0 10 20 30 40 50 60 65 70 (HORIZONTAL) 90 95 100 115 120 140 160 180 200 220 240 264 AMBIENT TEMERATURE ( ) INUT VOLTAGE (VAC) 60Hz File Name:RS-60-SEC 2008-03-25

Single Output Switching ower Supply RS-60 series MODEL:RS-60-12 OUTUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 120 mvp-p (Max ) I/: 230VAC O/:FULL LOAD V1: 46 mvp-p (Max ) 2 OUTUT VOLTAGE CH1: 11.4V~ 13.2V I/: 230 VAC 10.97 V~ 13.52 V/ 230 VAC ADJUST RANGE I/: 115 VAC O/:MIN LOAD 10.97 V~ 13.52 V/ 115 VAC 3 OUTUT VOLTAGE V1: 2 %~ -2 % (Max) I/: 115 VAC / 264 VAC V1: 0.1 %~ -0.1 % TOLERANCE O/:FULL/ MIN LOAD 4 LINE REGULATION V1: 0.5 %~ -0.5 % (Max) I/: 115VAC ~ 264 VAC O/:FULL LOAD V1: 0.05 %~ -0.05 % 5 LOAD REGULATION V1: 1%~ -1 % (Max) I/: 230 VAC O/:FULL ~MIN LOAD V1: 0.1 %~ -0.1 % 6 SET U TIME 230VAC: 115 VAC: 500 500 (Max) (Max) I/: 230 VAC I/: 115 VAC O/:FULL LOAD 230VAC/ 115VAC/ 396 377 7 RISE TIME 230VAC: 30 (Max) I/: 230 VAC 230VAC/ 9 115VAC: 30 (Max) I/: 115 VAC 115VAC/ 7 O/:FULL LOAD 8 HOLD U TIME 230VAC: 115VAC: 50 14 (TY) (TY) I/: 230 VAC I/: 115 VAC O/:FULL LOAD 230VAC/ 115VAC/ 71 14.13 9 OVER/UNDERSHOOT TEST < +5% I/: 230 VAC TEST: <5 % O/:FULL LOAD 10 DYNAMIC LOAD V1: 1200 mvp-p I/: 230 VAC O/:FULL /Min LOAD 90%DUTY/1KHZ 250 mvp-p Model: RS-60-12 Test Report 1 / 5

Single Output Switching ower Supply RS-60 series INUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 INUT VOLTAGE RANGE 90VAC~264 VAC I/:TESTING O/:FULL LOAD I/: LOW-LINE-3V= 87 V HIGH-LINE+15%=300 V O/:FULL/MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF ) 68 V~264V TEST: OK 2 INUT FREQUENCY RANGE 47HZ ~63 HZ OSC I/: 90VAC ~ 264 VAC O/:FULL~MIN LOAD 3 EFFICIENCY 83% (TY) I/: 230 VAC O/:FULL LOAD 4 INUT CURRENT 230V/ 1 A (TY) I/: 230 VAC TEST: OK 83.4 % 115V/ 1.8 A (TY) I/: 115 VAC I = 1.11 O/:FULL LOAD 1 5 INRUSH CURRENT 230V/ 60 A (TY) I/: 230 VAC I = 0.7 A/ 230 VAC A/ 115 VAC I = 51 A/ 230 VAC 115V/ 30 A(TY) I/: 115 VAC I = 26 A/ 115 VAC COLD START O/:FULL LOAD 6 LEAKAGE CURRENT < 200 ua/ 264 VAC for earth I/: 264 VAC O/:Min LOAD < 100 ua/264 VAC for patient I/: 264 VAC O/:Min LOAD L-FG: 74 ua N-FG 74 ua L-FG: 36 ua N-FG 36 ua ROTECTION FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 OVER LOAD ROTECTION 115 %~ 150 % I/: 230 VAC I/: 115 VAC O/:TESTING 136 %/ 230 VAC 139 %/ 115 VAC Hiccup Mode 2 OVER VOLTAGE ROTECTION CH1: 13.8 V~ 16.2 V I/: 230 VAC I/: 115 VAC O/:MIN LOAD 15.17 V/ 230 VAC 15.17 V/ 115 VAC Shunt down Re- power ON 3 SHORT ROTECTION SHORT EVERY OUTUT 1 HOUR I/: 264 VAC O/:FULL LOAD Hiccup Mode ONTROL FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 No load power consumption <0.75W I/: 240 VAC 0.44W/240VAC O/:NO LOAD Model: RS-60-12 Test Report 2 / 5

Single Output Switching ower Supply RS-60 series ENVIRONMENT TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 TEMERATURE RISE TEST MODEL:RS-60-12 1. ROOM AMBIENT BURN-IN:2HRS I/: 230VAC O/: FULL LOAD Ta= 34.5 2. HIGH AMBIENT BURN-IN:2 HRS I/: 230VAC O/: FULL LOAD Ta= 48.8 NO osition /N ROOM AMBIENT Ta=34.5 HIGH AMBIENT Ta= 48.8 1 BD1 US4K 4A/800V SHI 72.0 84.1 2 D1 EG20J 2A/600V ZOW 107.8 119.6 3 Q1 2SK2545 2A/600V TOS 103.3 114.5 4 ZD1 6KE100A AN 90.5 101.4 5 C36 100U/50V NCC 105 KY 71.5 83.4 6 T1 COIL TF-1415 LS 91.6 103.4 7 D100 20CTQ150 20A/150V IR 91.3 103.1 8 C105 560u/35V NCC 105 KY 74.7 86.0 9 L100 RB023D 69.3 80.6 10 U1 NC1230D 78.6 90.9 2 OVER LOAD BURN-IN TEST 1 HOUR ( MIN ) 3 LOW TEMERATURE TURN ON AFTER 2 HOUR TURN ON TEST I/: 230 VAC O/: 125 % LOAD I/: 230 VAC O/:100 % LOAD Ta= -20 4 HIGH HUMIDITY HIGH TEMERATURE HIGH VOLTAGE TURN ON TEST 5 TEMERATURE COEFFICIENT AFTER 12 HOURS IN CHAMBER ON CONTROL 50 I/: 272 VAC O/:FULL LOAD Ta= 50 HUMIDITY= 95 %R.H + 0.03 %(0~50 ) I/: 230 VAC O/:FULL LOAD 6 VIBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) + 0.01 %(0~50 ) Model: RS-60-12 Test Report 3 / 5

Single Output Switching ower Supply RS-60 series SAFETY TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 WITHSTAND VOLTAGE I/-O/: 4 KVAC/min I/-FG: 1.5 KVAC/min O/-FG: 1.5 KVAC/min I/-O/: 4.2 KVAC/min I/-FG: 1.8 KVAC/min O/-FG: 1.8 KVAC/min I/-O/: 2.14 ma I/-FG: 1.54 ma O/-FG: 1.57 ma 2 ISOLATION RESISTANCE I/-O/:500VDC>100MΩ I/-O/: 500 VDC I/-O/: 30 GΩ I/-FG: 500VDC>100MΩ O/-FG:500VDC>100MΩ I/-FG: 500 VDC O/-FG: 500 VDC I/-FG: 30 GΩ O/-FG: 30 GΩ 3 GROUNDING CONTINUITY FG(E) TO CHASSIS OR TRACE < 100 mω 40 A / 2min 8 mω 4 AROVAL TUV: Certificate NO :R 50112371 UL: File NO :E227340 E.M.C TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 HARMONIC EN61000-3-2 CLASS A I/: 230 VAC/50HZ O/:FULL LOAD ASS 2 CONDUCTION EN55022 EN55011 I/: 230 VAC (50HZ) ASS CLASS B O/:FULL/50% LOAD Test by certified Lab 3 RADIATION EN55022 EN55011 I/: 230 VAC (50HZ) ASS CLASS B O/:FULL LOAD Test by certified Lab 4 E.S.D EN61000-4-2 I/: 230 VAC/50HZ CRITERIA A MEDICAL AIR:8KV / Contact:6KV O/:FULL LOAD 5 E.F.T EN61000-4-4 I/: 230 VAC/50HZ CRITERIA A MEDICAL INUT: 2KV O/:FULL LOAD 6 SURGE IEC61000-4-5 I/: 230 VAC/50HZ CRITERIA A MEDICAL L-N :1KV O/:FULL LOAD L,N-E:2KV 7 Test by certified Lab & Test Report repare M.T.B.F & LIFE CYCLE CALCULATION NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 CAACITOR LIFE CYCLE SUOSE C105 IS THE MOST CRITICAL COMONENT I/: 230VAC O/:FULL LOAD Ta= 25 LIFE TIME= 122610 HRS I/: 230VAC O/:FULL LOAD Ta= 50 LIFE TIME= 26651 HRS 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 353.6K HRS 3 ORT (Ongoing Reliability test) I/:230VAC O/:FULL LOAD TA=50.6 Sample=20pcs TEST TIME=792HRS Model: RS-60-12 Test Report 4 / 5

Single Output Switching ower Supply RS-60 series COMONENT STRESS TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 ower Transistor ( D to S) or (C to E) eak Voltage Q1 Rated K2545 : 600V 2 Diode eak Voltage D100 Rated 6A 20CTQ150 : 150V 3 Clamp Diode eak Voltage D1 Rated EG20J : 600V 2A 20A I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2) Output Short I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2)Output Short I/:High-Line +3V = 267 V O/: (1) Dynamic Load 90%Duty/1KHz (1) 558 V (2) 592 V (1) 117 V (2) 116 V (1) 464 V 4 Input Capacitor Voltage C5 Rated :100u / 400V/ 105 I/:High-Line +3V = 267 V O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 370 V (2) 374 V (3) 370 V 5 Control IC Voltage Test U1 Rated 1230D : 18 V I/:High-Line +3V = 267 V O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 15.2 V (2) 13.4 V (3) 15.2 V DATE SAMLE TEST RESULT TESTER AROVAL 2006/4/3 RD SAMLE ASS VINCENT TSENG MAX LIN 2006/6/2 2006/7/20 RODUCT SAMLE W0605A17 RODUCT SAMLE W0607A12 ASS VINCENT TSENG MAX LIN ASS VINCENT TSENG MAX LIN 2003/12/12 A50-F023 Model: RS-60-12 Test Report 5 / 5