Blackjack Conduit Grounding Bushing. Lug Screw: 14-4: Slotted 14-2/0: Slotted 6-4/0: Internal Hex Drive

Similar documents
Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit

Symbols. Short Descriptions. Formula for Tool Lengths. Thread Milling DIN 13 WKZ = L GK + L 1 + L P1 (+L P2 ) Thread standard.

CONTACT TYPE U: UPPER CONTACT (TOP CONTACT) BLANK: LOWER CONTACT (BOTTOM CONTACT) PACKAGE T: TUBE T/R: TAPE & REEL NO. OF PIN

Ground Clamps Cable Tray

Specifications. According to CEC Rule Please Note

markilux syncra 2 fix / syncra 2 uno fix with Folding-arm Awnings

I- 39. Liquidtight Connectors and Hubs for Liquidtight Flexible Metal Conduit General Information and special features.

Ultra Precision V-Flange Tooling

Zinc Cable & Conduit Connectors For Armored Cable, Flexible Metal Conduit & Metal Clad Cable

Metal Clad Cable, Armored Cable and Flexible Metal Conduit Fittings

Family Figures A380 A350 A330 A320. July 2017 Edition

Family Figures A380 A350 A330 A320. July 2017 Edition

CABLE GRIPS CABLE GRIPS

T&B Fittings. Industrial Fittings. Table of Contents

T&B Fittings. Industrial Fittings. Liquidtight Flexible Nonmetallic Conduit Fittings. Specifications Type A Conduit Fittings

Fish Tapes & Conduit Tools

HANDWHEELS.

Cover, 1 Gang; Malleable Iron; Zinc Electroplated Dichromate Aluminum Polymer Enamel; Box Mounting; Appleton[R] Brand; FS Model; With Square Handle

UNIVERSAL PARTS GLOBAL

Pole Line Hardware. Catalog

CONTENTS. Gold Bond Fasteners Bolts 1 Clamps 3 Nuts 4 Washers 5. Hoist Rings Center Pull 6 Side Pull 7. Socket Head Stripper Bolts Inch 8 Metric 9

Insulated Tools. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Rigid Conduit AMERICAN FITTINGS. When It Comes Your Electrical Fittings, Trust One Name, AMERICAN. Corporation. Alloy Steel Electrical Fittings

STRAIGHT BLADE RECEPTACLES

Russellstoll. Electrical Interconnection Systems. Dura-Gard Nonmetallic Waterproof Connections. The Next Generation: Dura-Gard

SIN GLE BOND HOSE CLAMPS

BUILDING A BANNER STAND & STANDARD

HANDLES, LE VERS & CR ANKS

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

PRELAB: FORCES AND MOTION

2pcs/pack. Auto Loading Utility Knife. Electrician's Knife Carton Cutter Utility Folding Knife Utility Cutter

Tuf-Lite and Tuf-Lite II Fans 6000M Series Hub

Industrial Specification Grade Straight Blade Receptacles. Duplex and Single Receptacles

Application A liquidtight fitting to secure flexible cord or power cable to a box or enclosure and provide strain relief. Standard Material/Finish

CNC With the user in mind. More powerful than ever

Emergency Stop Devices

RV RULES OCTOBER 26 29, 2017

RTA flexible conduits

Strut Clamp Pipe & Conduit

Tuf-Lite III Fans 4000KW Series Hub

CATALOG FITTINGS CATALOG

WORKHOLDING COMPONENTS

Electrician's Insulated Tools

Couplings for Gates Hoses 7 Combination Nipple

Induction hardened cutting knives for long life. Thick, exceptionally tough, high-dielectric white inner coating is bonded to the tool

Tuf-Lite and Tuf-Lite II Fans 6000 Series Hub

DRAWER SYSTEMS HEAVY-DUTY STEEL & ALUMINUM Heavy-Duty Steel Drawer System. Heavy-Duty Aluminum Drawer System

A A A T E C H N O L O G Y

Aviation Snips. Multi-Cable Cutter

FERRULES & TOOLS Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

MArInA SAnDs 250 VERDE. CS-AcTiVA 11. FLoRiDA SIeNa GAlIlEO Lux FJoRd

TRUSTED SOLUTIONS AND INNOVATION PINS & BUSHINGS INCH

2016 PRODUCTS & PRICES

ANNEX C. List of eligible investments

PROFILE SYSTEM HANDLES, LOCKS, STOPS HANDLE, LOCKS, STOPS 108 MINITEC PROFILE SYSTEM

PINS & BUSHINGS INCH

ot the'june 28 meeting be approved as written

Visit us at 5170 N 125th St. Butler WI or online at 197

9/16" deep socket Socket wrench (ratchet) 3/16" drill bit 5/8" spade bit Electric drill or power screwdriver Safety glasses

ExoFit NEX Full Body Harness

D. S. HULL COMPANY, INC

AXELENT WIRE TRAY Wire Trays, Fittings, Mountings and Accessories. Technical manual

Grounding Clamp. Pins and Ball-Socket Clamps for Temporary Grounding

Otter Pro XT Cabin Installation and Set-Up Instructions

Safety Interlock Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

MOVE FASTER ORGANIZE. PERSONALIZE * for uniqueness

T&S BRASS AND BRONZE WORKS, INC.

THEY VEGOT CARBIDE BURRS

HANDLES LHF115, LHR115, LHPB VARIOUS. Base Model Handles. MATERIAL Steel. FINISH Chrome Plated LHR115-1A

Insulated Tools S 9 R O T E CTI Y N

MACHETES & MACHETE SHEATHS HUDSON BAY AXE SINGLE EDGE AXE GUARD DOUBLE EDGE AXE GUARD LADDER PLATFORM. Machete CAT. NO.

HINGES & STAYS. Hinges & Stays Large Take-Apart Hinge. Medium Take-Apart Hinge

Aluminum Gas Venting. Key Features

get connected with Bradford fittings & valves Bradford Company, Inc

SKU Product Name Price American Underslung

ORDIC FIBERGLASS, INC.

Tuf-Lite II Fans 8000 Series Hub

TM ENTERTAINMENT CABLE

SH, MP, HP, EZ-SH, EZ-MP, EZ-HP Series Design Features & Benefits COXREELS. SH, MP, HP, EZ-SH, EZ-MP, & EZ-HP Series Design Features

Product Catalogue. Breezy Everyday Living Aids Premium Products. Quality Service. Breezy Everyday Product Catalogue 2017 January

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

NEW PRODUCTS 6-7 HEAVY DUTY

Limit Switches. 6.2 E47 Precision Switches

Genesis. Side Burner Accessory Installation. Step 3. Step 1. Step 2. For use with Genesis Gas Barbecues Only

IMPORTANT OWNER-OPERATOR INSTALLATION INSTRUCTIONS. Part # A7006

Worm Gear Clamps. Spiral Double-Bolt Clamps. The Ultimate in Clamping for Your Vacuum Hose. With Plated Carbon Steel Deep-Slotted Screw

2018 Specifications & Pricing Guide. Check our website: for updates and new product offerings.

3L4. Hub is chamfered. Dimension C may be changed upon request. Engineering charges may apply to certain sizes. 1/4 M6 5/16 M8 3P1 * TK4 * 3P4 3L4

Knives, Cutters & Scrapers

Otter Pro X-Over Lodge Installation and Set-Up Instructions

HSS PLANER & JOINTER INDIVIDUAL KNIVES

4-foot Economy Sign Post. 4-foot post is rated at 2 pounds per foot. 7-foot Economy Sign Post

LSC19 Lighting Cable Assemblies and Connectors


PARTS INCLUDED IN YOUR KIT. You may want to lay them out in this manner for accessibility. Foam has NO adhesive to touch truck finish.

SECTION SPECIFICATIONS PART 1 GENERAL

WRANGLER 1710AB, 2010AB

Bruna Epdm Neopr Sizes: ½, ¾, 1, 1 ¼, 1 ½, 2, 2 ½, 3, 4, 5, 6 Full Teflon Viton CAM ARMS - PINS RINGS FOR CAMLOCKS

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications. Illustrated Features

Transcription:

Blackjack Condui Grounding Bushings T&B Condui Fiings Rigid and Inermediae Meal Condui Fiings Mouning screw wih nylon locking pach has a cone poin o lock bushing securely in place. Insulaor surface feaures a rounded design o reduce drag and preven abrasion during wire pulling. Inegral grounding lug enhances ground coninuiy. Added ground wire range aking reduces invenory. Acceps copper or aluminum ground wires. Insulaing nylon surface is 150 C raed and covers op of bushing, including lug corners. Angle of lug screw improves accessibiliy when securing grounding wire. Cas hreads opposie he mouning screw ighen he fi during insallaion. Innovaive design makes insallaion quicker, easier. The Blackjack Grounding Bushing never has o be hreaded ono a condui. I is simply placed in posiion on eiher a hreaded or non-hreaded rigid or IMC condui, wih he grounding lug in perfec posiion o accep he grounding wire. Even in igh insallaions, i s as simple as one, wo, hree. Compare he insallaion wih convenional bushings ha mus be hreaded ono he condui. In igh areas, you may have o remove he grounding lug, keep up wih he loose pars, and hen reaach he lug. Then you sill have o wis and urn he bushing o ge he lug in posiion o accep he grounding wire. The Blackjack bushing does away wih hese needless delays for good, making i he ideal grounding bushing and he only logical choice for small spaces, corners, and muliple condui runs. And, because he grounding lug is an inegral par of he bushing, i is designed no o fall off or ge los. Innovaive design improves performance. The Blackjack bushing provides superior ground coninuiy. The design of he Blackjack bushing has an inegral, cas-on grounding lug for beer ground coninuiy. This means ha he Blackjack bushing sands up o inense loads. Secure grip forms lasing bond. The Blackjack bushing s conepoin mouning screw bies securely ino boh hreaded and non-hreaded rigid conduis. And he Blackjack bushing s nylon locking pach is designed o preven he screw from loosening due o vibraion. Reduce invenory. Because he Blackjack Grounding Bushing is designed for hreaded and non-hreaded conduis, and he ground lugs are designed o handle an exended range, he number of pars in invenory is reduced by up o wo-hirds wihou losing any applicaion coverage. Blackjack Condui Grounding Bushing Lug Screw: 14-4: Sloed 14-2/0: Sloed 6-4/0: Inernal Hex Drive Sandard Maerial/Finish Body: Malleable Iron or Aluminum Mouning Screw: (1/2"-2") Sainless Seel, (2-1/2"-6") Brass Lug Screw: Sainless Seel Finish: Zinc Plaed or Mechanical Galvanized Condui: 1/2 hru 6" hreaded or hreadless rigid/imc Wire : #14 AWG o 4/0 AWG CU/AL Conformiy U.L. 514B & U.L. 467 CSA C22.2 No. 18.3 & CSA C22.2 No. 41 13

T&B Condui Fiings Rigid and Inermediae Meal Condui Fiings Blackjack Condui Grounding Bushings Ca No. Ca No. Zinc Condui Dim. Plaed Size ØA ØB ØC ØD E Wire Malleable Iron Aluminum in. Max. Max. Max. Max. Max. BG050-14-20 BGA050-14-20 1/2 1.251.569 1.181 2.134.696 14-2/0 BG050-14-4 BGA050-14-4 1/2 1.251.569 1.027 1.940.696 14-4 BG075-14-20 BGA075-14-20 3/4 1.533.772 1.221 2.414.696 14-2/0 BG075-14-4 BGA075-14-4 3/4 1.533.772 1.030 2.168.696 14-4 BG100-14-20 BGA100-14-20 1 1.783.993 1.181 2.581.696 14-2/0 BG100-14-4 BGA100-14-4 1 1.783.993 1.027 2.368.696 14-4 BG125-14-20 BGA125-14-20 1-1/4 2.220 1.319 1.181 2.987.759 14-2/0 BG150-14-20 BGA150-14-20 1-1/2 2.470 1.553 1.181 3.236.696 14-2/0 BG200-14-20 BGA200-14-20 2 2.830 2.010 1.181 3.766.696 14-2/0 BG250-14-20 BGA250-14-20 2-1/2 3.148 2.412 1.181 4.341.978 14-2/0 BG250-6-40 BGA250-6-40 2-1/2 3.148 2.412 1.524 4.526.978 6-4/0 BG300-14-20 BGA300-14-20 3 4.042 3.022 1.181 4.966.978 14-2/0 BG300-6-40 BGA300-6-40 3 4.042 3.022 1.524 5.139.978 6-4/0 BG350-14-20 BGA350-14-20 3-1/2 4.542 3.491 1.181 5.467.978 14-2/0 BG350-6-40 BGA350-6-40 3-1/2 4.542 3.491 1.524 5.639.978 6-4/0 BG400-14-20 BGA400-14-20 4 5.042 3.975 1.181 5.966.978 14-2/0 BG400-6-40 BGA400-6-40 4 5.042 3.975 1.524 6.139.978 6-4/0 BG500-14-20 BGA500-14-20 5 6.136 4.991 1.181 7.045.978 14-2/0 BG500-6-40 BGA500-6-40 5 6.136 4.991 1.524 7.207.978 6-4/0 BG600-14-20 BGA600-14-20 6 7.199 6.009 1.181 8.087.978 14-2/0 BG600-6-40 BGAT600-6-40 6 7.199 6.009 1.524 8.409.978 6-4/0 Suggesed Specificaions Insulaed grounding and bonding bushing (Series BG050-BG600) Where code requires bonding and grounding of single or muliple meal conduis, or posiive bonding and grounding of meal condui o he box, enclosure or auxiliary guer, he end of he condui shall be equipped wih an insulaed meallic grounding and bonding bushing series BG050-14-20 as manufacured by Thomas & Bes. Grounding and bonding bushings used shall be approved for he purpose and (i) Shall be of malleable iron/seel/aluminum consrucion adequaely proeced agains corrosion. (ii) Bushing insulaor shall be lised or cerified for 150 C/302 F applicaion wih a flammabiliy raing of 94V-O. Insulaor mus be posiively locked in place. * Mechanical galvanizaion is available in he 3870 Series; add suffix MG o Ca. No. Nylon Insulaor (150 o C) Mouning Screw Lug Screw 14-4: Sloed 14-2/0: Sloed 6-4/0: Inernal hex drive ØA E C D ØB Throa I.D. For Threaded & Threadless Rigid & IMC Condui. 14

T&B Condui Fiings Rigid and Inermediae Meal Condui Fiings Threaded Insulaed Grounding Bushing Applicaion For quick insallaion of bonding jumper o muliple meal conduis (Rigid and IMC). Designed o bush conducors and preven insulaion damage. Sandard Maerial / Finish Body: Elecro-zinc plaed Lay-in lug: Aluminum/in plaed Insulaor: Thermoplasic 150 C/302 F Applicaion wih 94V-0 flammabiliy. Feaures Ease of insallaion, lay in lug design. Cas malleable iron body designed o lock insulaor in place wihin body reducing common assembly problem resuling in dislodging of insulaor. Insulaor raed for 150 C/302 F applicaion. Wire Clamping Screw Insulaor Se-Screw (one) Lay-In* Lug Bushing Casing Threaded Insulaed Grounding Bushing Wire Condui Bushing Throa Lug Swing Bushing AWG Ca. No. Size Dia. Dia. Lengh Radius Heigh CU/AL 3870-TB 1/2 1.125.560 1.310 1.212.657 14-4 3861 1/2 1.125.560 1.675 1.402.657 8-2/0 3871-TB 3/4 1.420.742 1.310 1.360.660 14-4 3862 3/4 1.420.742 1.675 1.550.660 8-2/0 3872 1 1.770.944 1.310 1.535.735 14-4 3882 1 1.770.944 1.675 1.725.735 8-2/0 3873 1-1/4 2.190 1.242 1.310 1.745.735 14-4 3883 1-1/4 2.190 1.242 1.675 1.935.735 8-2/0 3874 1-1/2 2.468 1.449 1.310 1.884.770 14-4 3884 1-1/2 2.468 1.449 1.675 2.074.770 8-2/0 3875 2 3.031 1.860 1.310 2.165.770 14-4 3889 2 3.031 1.860 1.675 2.355.770 8-2/0 3876 2-1/2 3.516 2.222 1.310 2.408.940 14-4 3886 2-1/2 3.516 2.222 1.675 2.598.940 8-2/0 3993 2-1/2 3.516 2.222 2.230 2.928.940 6-4/0 3877 3 4.234 2.761 1.310 2.767.975 14-4 3887 3 4.234 2.761 1.675 2.957.975 8-2/0 3994 3 4.234 2.761 2.230 3.287.975 6-4/0 3878 3-1/2 4.781 3.193 1.310 3.040.975 14-4 3863 3-1/2 4.781 3.193 1.675 3.230.975 8-2/0 3995 3-1/2 4.781 3.193 2.230 3.560.975 6-4/0 3879 4 5.328 3.623 1.310 3.314.980 14-4 3864 4 5.328 3.623 1.675 3.504.980 8-2/0 3996 4 5.328 3.623 2.230 3.834.980 6-4/0 3880 5 6.328 4.542 1.310 3.814.985 14-4 3865 5 6.328 4.542 1.675 4.000.985 8-2/0 3998 5 6.328 4.542 2.230 4.334.985 6-4/0 3881 6 7.406 5.458 1.310 4.353 1.200 14-4 3866 6 7.406 5.458 1.675 4.543 1.200 8-2/0 3999 6 7.406 5.458 2.230 4.875 1.200 6-4/0 Temperaure raing 150 C. Mees Coas Guard Regulaion CG293 For Dura-Plae finish, add prefix 040- o Ca. No. Consul Cusomer Service for deails. *Conac cusomer service for copper lay in lug 15

T&B Condui Fiings Rigid and Inermediae Meal Condui Fiings Nylon insulaed meallic bushings Seel or malleable iron (Seel hru 1-1/2 ). The Canadian Elecric Code 10-906 (2) calls for proecion of ungrounded conducors by means of smoohly rounded insulaing surfaces a he enrance o raceways, pull boxes, juncion boxes, ec. T&B insulaed hroa fiings, recognizable by he disincive rademarked blue insulaing liner in he hroa, mee and surpass his Code requiremen. In addiion, T&B insulaed fiings also reduce wire pulling effor by as much as 50%. Temperaure raing 105 C. Insulaed Throa Fiings Dimensions (in.) Ca. No. Size A B 1222 1/2 1-1/32 29/64 1223 3/4 1-9/32 31/64 1224 1 1-19/32 19/32 1225 1-1/4 1-15/16 21/32 1226 1-1/2 2-3/16 23/32 1227 2 2-11/16 7/8 1228 2-1/2 3-3/16 31/32 1229 3 3-27/32 15/16 1230 3-1/2 4-7/16 1-1/16 1231 4 4-7/8 1-3/32 1232 4-1/2 5-7/16 1-15/64 586 5 5-31/32 1-9/32 587 6 7-3/16 1-11/32 No CSA Cerified Caalogue series 1222 hru 1232, 586 and 587 are available in aluminum. Add suffix AL o Ca. No. The aluminum series are no CSA cerified. Aluminum, seel or malleable iron (seel hru 1-1/2 ). Smoohly rounded shoulder covers end of condui; broad flange covers knockou hole. High ribs make ighening easy wih fingers or wih wrench. 1/2-1-1/2 sizes, formed in seel, have exra smooh shoulders. Locknu-ype base gives improved bonding and resiss loosening under condiions of vibraion. Meallic Bushings Ca. No. Dimension (in.) Sl. or M.I. Alum. Size A B 122 122AL 1/2 1-1/32 13/32 123 123AL* 3/4 1-9/32 13/32 124 124AL 1 1-19/32 1/2 125-TB 125AL 1-1/4 1-15/16 9/16 126 126AL 1-1/2 2-3/16 9/16 127 127AL 2 2-11/16 19/32 128 128AL 2-1/2 3-3/16 13/16 129 129AL 3 3-27/32 13/16 130-TB 130AL 3-1/2 4-7/16 15/16 131-TB 131AL 4 4-7/8 1 132-TB 4-1/2 5-7/16 1-5/64 133-TB 133AL 5 6-1/16 1-1/16 134-TB 134AL 6 7-3/16 1-1/16 * No U.L. Lised or CSA Cerified For Dura-Plae finish, add prefix 040- o Ca. No. Consul Cusomer Service for deails. 16

T&B Condui Fiings Rigid and Inermediae Meal Condui Fiings A B All Plasic Insulaing Bushings Impac-resisan plasic insulaion. These bushings have ribs for gripping when insalling. Perfec hreads for easy hread on. U.L. Lised 105 C. NPT hreaded. Plasic Insulaing Bushings Dimensions (in.) Ca. No. Size A B 222-TB 1/2 1-1/16 3/8 223-TB 3/4 1-9/32 13/32 224 1 1-37/64 9/16 225-TB 1-1/4 2-1/32 9/16 226 1-1/2 2-15/64 9/16 227 2 2-25/32 5/8 228-TB 2-1/2 3-13/32 3/4 229-TB 3 4-3/32 3/4 230-TB 3-1/2 4-5/8 7/8 231 4 5-3/16 7/8 232 4-1/2 5-5/8 7/8 233 5 6-3/8 1 234 6 7-7/16 1 Flame reardan. U.L. Raed 94V-1. 17

T&B Condui Fiings Rigid and Inermediae Meal Condui Fiings Insulaing Bushing TRIB50 Series (For Threadless Rigid Condui and Inermediae Meal Condui) Applicaion When assembled o he end of a hreadless condui, provides a well rounded insulaing surface over which conducors may be pulled or on which conducors may bear while in service. Sandard Maerial High impac hermoplasic lised for 105 C (221 F) applicaion. Flammabiliy Classificaion 94V-1. Sandard Finish As molded. 1. Cu condui end squarely. Remove sharp edges and burrs on inside and ouside diameers by reaming or filing. 2. Slip he pop-on bushing over he end of he condui. Feaures Designed o be popped ono, and bush, condui end. Fas easy insallaion wihou screws. High impac hermoplasic consrucion. 1/2 hrough 4 condui Conformiy U.L. 514B ANSI C80.4 NFPA 70-2008 (ANSI) 3. Using he fla surface of any sandard uiliy ool such as an elecricians pliers (or a hammer wih a block of wood, for he larger sizes), srike he bushing on is op surface using a series of ligh blows unil he end of he condui ress agains he bushing hroa and condui sop. Insulaed Meallic Bushing Dimensions (in.) Ca. No. Size A B C TRIB-50 1/2 19/32 1-9/32 1-1/16 TRIB-75 3/4 25/32 1-25/64 1-1/4 TRIB-100 1 1 1-1/2 1-9/16 TRIB-125 1-1/4 1-5/16 1-5/8 1-59/64 TRIB-150 1-1/2 1-17/32 1-21/32 2-11/64 TRIB-200 2 1-31/32 1-13/16 2-11/16 TRIB-250 2-1/2 2-23/64 2 3-1/4 TRIB-300 3 2-59/64 2-7/32 3-29/32 TRIB-350 3-1/2 3-3/8 2-5/16 4-29/64 TRIB-400 4 3-27/32 2-13/32 5 I.M.C. sizes 1/2 hru 4 U.L. Raed flame reardan 94V-1. A B C 18

T&B Condui Fiings Rigid and Inermediae Meal Condui Fiings Knockou Bushings 3210 Series Applicaion To bush knockou openings in meal boxes or enclosures. Feaures One piece consrucion designed o snap in place. High impac srengh self-exinguishing, non-dripping (per U.L. 94) hermoplasic consrucion. Sandard Maerial Thermoplasic raed for 105 C (221 F) applicaion. Sandard Finish As molded..875 hrough 2.469 nominal diameer knockou opening (1/2 hrough 2 rade size knockous). Wall hickness of box or enclosure.095 max. up o 1 rade size..140 max. 1-1/4 hrough 2 rade size. Conformiy U.L. 514B CSA C22.2 No. 18.3 NFPA 70-2008 (ANSI) One-piece knockou bushing quickly snaps ino oule box, swich box, or oher enclosure lef vacan by wiring modificaions or mainenance changes. Provides smooh, rounded insulaion surface for easy wire pulling. Easily insalled by hand, hey are available o fi 1/2 hrough 2 knockous. U.L. Lised 105 C. High impac hermoplasic. Knockou Bushing For use Wall Trade in KO* Thickness Ca. No. Size +.032/-.016 A B of Elec. Box C D 3210 1/2.875 1.000.725.095 MAX.360.180 3211 3/4 1.109 1.215.940.095 MAX.360.180 3212 1 1.375 1.500 1.200.095 MAX.360.180 3213 1-1/4 1.734 1.865 1.550.140 MAx.400.210 3214 1-1/2 1.984 2.240 1.760.140 MAX.530.310 3215 2 2.469 2.740 2.245.140 MAx.530.310 * Per U.L. and NEMA sandards. Maerial: Thermoplasic Flammabiliy classificaion of 94V-1 Per UL 94 Service emperaure: -40 C o 105 C. B Slip over wires inser ino bushing snaps ino place High dielecric nylon, 105 C. An insuliner sleeve snapped ino a regular bushing makes a CSA Lised insulaed bushing. For sandard rigid condui, E.M.T. (hinwall condui) or any sandard bushed oule. Especially suiable for use wih flexible meallic condui. Convers ordinary bushing o code approved insulaed bushing wihou disurbing wiring. A INSULINER Sleeves Dimension (in.) Ca. No. Size A B 422 1/2 5/8.022 423 3/4 11/16.025 424 1 7/8.040 425 1-1/4 1.040 426-TB 1-1/2 1.050 427-TB 2 1-1/8.050 428-TB 2-1/2 1-1/4.035 429 3 1-1/2.035 430-TB 3-1/2 1-25/32.035 431 4 2-1/32.035 433 5 2-1/2.035 434 6 2-1/2.035 Oxygen index >28 19