TECHNICAL INFORMATION Primer Residue Collection Kit for SEM, ICP-MS and AAA Catalog No. GRA100

Similar documents
How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g.

How to Use Your Implanted Venous Port

Field Situation - How to safely collect oral swabs (saliva) from deceased patients suspected to be infected with Ebola

Cultures, Specimen Collection for

LESSON ASSIGNMENT. Surgical Asepsis and Sterile Technique. After completing this lesson, you should be able to:

Administration of Micafungin Using Minibag Plus & DIAL-A-FLO

Performing Hand Hygiene Using an Alcohol-Based Handrub

How to safely collect blood samples by phlebotomy from patients suspected to be infected with Ebola or Marburg

FORM (Apr. 2006)

NNIN Nanotechnology Education

Mixing Your Alpha-1 Therapy Aralast NP

How to safely collect oral swabs (saliva) from deceased patients suspected to be infected with Ebola or Marburg

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE

Investigation of the effect of antibiotics on bacterial growth. Introduction. Apparatus. Diagram of Apparatus

Operating Instructions

Instructions for Use AIMOVIG TM (AIM-oh-vig) (erenumab-aooe) Injection, For Subcutaneous Use Single-Dose Prefilled SureClick Autoinjector

Core practical 13: Isolate an individual species from a mixed culture of bacteria using streak plating

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV

Operating Instructions

Making Solar Cells 1 from Household Materials (mostly :)

Adult Diaper. Our Adult Diapers are Ultra Absorbent with 10 SAP for best convenience to patients and one of the best available in India.

QUANTUM ARM POSITIONER IFU (INSTRUCTIONS FOR USE) The Quantum Arm Positioning System

Adult Diapers. Anti Bacteria Anti Odour Anti Allergy Wetness Indicator Extra Absorbent Leak Proof

Instructions. Fibrlok TM 2670 Multi-Fiber Ribbon Construction Tool. November, B

TOYOTA TUNDRA BEDRUG Preparation

Safety and Rules of the Lab

Chapter 12 Protective Clothing

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER

PL500A Platform Extension

The Enbrel SureClick autoinjector is a single-dose prefilled autoinjector. It contains one 50 mg dose of Enbrel.

SYSTIMAX RoloSplice Multiple Splice Organizer Installation

#6 Spill and Accident Procedures

OUTDOOR SERIES Mosquito protection you don t spray on Repels mosquitoes, black flies and flying insects Provides 15 x15 ft of repellency, the size of

First Aid Kit Items. flippresources.org. Duct Tape

WARNING: IMPROPER INSTALLATION WILL RESULT IN LINER FLYING OUT OF THE TRUCK. FOLLOW INSTRUCTIONS EXACTLY

Instruction Manual Remote Swabbing and Microbiological Sampling and Teflon template tools Version , Rev.0

AssayMAP Bravo Syringe Replacement

Installation Guide. LPKPDR - Universal LP Conversion Kit for Professional & Designer Ranges/Rangetops. Viking Range, LLC.

Operating Instructions

Blue Series Hot Melt Hose with RediFlext II Hanger System

FagronLab FG. Semi-automatic capsule filling machine. User Manual

Laboratory Safety. A practical approach.

First Aid Box Contents

Crimp & Cleave Termination Instructions

BAG-TO-BAG FILTER KIT FILTERED UNFILTERED GRN LINE WATER FLOW. USER MANUAL Model Number EPA Est. No UT-001

Crimp & Cleave Termination Instructions for 200 µm Factory5 Cable with ST and SMA Connectors

INSTALL INSTRUCTIONS for VEHICLES

SPILL RESPONSE PROGRAM

Standardised Parenteral Support Catheter Guidelines

Leica CE/ Leica CN. Knife holder

LBH18BPK. Instruction Sheet

COMPONENT IDENTIFICATION

How to Open a Glass Vial

British Intestinal Failure Alliance (BIFA) Guidance. Standardised Parenteral Support Catheter Guidelines

Get A Grip! Student Activity 1D Introduction: Materials: (per group) LESSON 2

Wenger Corporation 2014 Printed in USA 05/14 Part #049B015-09

HZS Field Spectroscopy Kit

FORM Rev. A (Feb. 2004)

Personal biosecurity measures

Instructions for Use Repatha (ri-path-a) (evolocumab) Single-Use Prefilled SureClick Autoinjector. Guide to parts

SB3T. Roll-InBuddy + Tilt. Dignity + Ease + Comfort. Product features include:

Operator s Manual. Medium-Duty Electric Slicers ENGLISH. Item Model Description Drive Peak HP Voltage Amps Hz Plug

1000M MANUAL Signature Series Slicer OPERATORS MANUAL

Apple Watch Screen Replacement

Crimp & Cleave Termination Instructions

Operating Manual. Revision D

Crimp & Cleave Termination Instructions

AND LOAD CANOPY RACK SPECIFICATIONS

SOURCE: Infection Prevention & Control (IPC)

Handy Hints for First Aid Kit Users

Pericardiocentesis Simulator with Chest Tube and Pneumothorax LF03769U Instruction Manual

Getting Started Guide

COMPONENT IDENTIFICATION

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

MAX Series 9514 OPERATOR S MANUAL

Items that are not wrapped or packaged correctly can allow contamination and therefore present a risk of infection to the patient.

BowDown. MiniMuM Crossbar spread 24 (61CM) Steel Hook (2X) Buckle Strap (2X) Plastic Tube (2X) Plain Strap (2X) SHORT BLACK T-BOLT (2x) BOWDOWN (2x)

S E L E C T I O N. Abdominal Crunch. User manual

OWNER S MANUAL. ezup.com. 13 x 13 (4.0m x 4.0m) 10 x 10 (3.0m x 3.0m) 16 x 16 (5.0m x 5.0m)

Crimp & Cleave Termination Instructions for 200 µm F07 Connectors

WIDESPREAD LAVATORY MODELS WITH HI-ARC SPOUT

Latmedical, LLC is the only Caribbean authorize distributor

Is this First Aid at your work place?

Instructions for Use: Duodenoscope Sampling Kit

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand

Globe Slicer Safety Tips

Caring for Your Chest Tube and Pneumostat Chest Drain Valve

Installation Instructions

For the diagnosis of Hirschsprung s Disease

ipad mini 4 Wi-Fi Volume Control Buttons Replacement

Termination Procedure LC 1.6mm & 2.0mm Connectors: 1060XX Series

Crimp & Cleave Termination Instructions for 200 µm Harsh Environment SMA

RAFTER VI. Installation and Operation CAREFREE WITH AUTOMATIC AWNING SUPPORT. RV Accessory PRODUCT OVERVIEW

SINGLE BURNER STOVE IMPORTANT OPERATING INSTRUCTIONS COOKING & STORAGE POSITION PARTS IDENTIFICATION

A Pre-Paid Return Label is included (optional) *Call for pick up no later than the above return date to avoid additional rental fees

TRANSFER PIPETS. transfer of liquids. Designed for the safe and convenient. transfer of liquids. Includes 52 NEW sterile pipets!

ASNSW NEANN ADK ADVANCED DRUG KIT INFORMATION BOOKLET. PLEASE READ BEFORE USE OR WARRANTY MAY BE VOID

Egg-streme Parachuting Flinn STEM Design Challenge

BigStack. Minimum Crossbar spread 24 For factory racks: Check fitlist notes, or Yakima.com for your vehicle s crossbar spread.

FibreGuard Closure with SLIDE-N-LOCK Fiber Management

Transcription:

SIRCHIE Products Vehicles Training Copyright 2011 by SIRCHIE All Rights Reserved. TECHNICAL INFORMATION Primer Residue Collection Kit for SEM, ICP-MS and AAA Catalog No. GRA100 INTRODUCTION The Primer Residue Collection Kit is designed for use by departments that anticipate submitting evidence for Scanning Electron Microscopy (SEM), Inductive Coupled Plasma Mass Spectrometry (ICP-MS) and Atomic Absorption Analysis (AAA). The GRA series gunshot residue analysis kits feature special alloy aluminum specimen mounts that contain no barium, antimony, or lead the most common constituents in cartridge residue. GRA tests are specific and sensitive for collection of gunshot residue using SEM techniques and are economical and uncomplicated. The GRA100 kit also contains the materials necessary to collect primer (barium and antimony) residue for ICP-MS and AAA. Control test firings show that the concentration of gunshot residue significantly declines after approximately 4 hours. Therefore, samples taken more than 4 hours after firing may not be acceptable for analysis. 100 HUNTER PLACE, YOUNGSVILLE, NC 27596 USA Ph: (919) 554-2244, (800) 356-7311 Fax: (919) 554-2266, (800) 899-8181 Web: www.sirchie.com Email: sirchieinfo@sirchie.com 1 of 8

CAUTIONS Before using this kit, consult the appropriate Material Safety Data Sheets (MSDS) found on our website at www.sirchie.com/support. The person taking samples must have hands that do not possess gunshot residues. Collector must wash hands thoroughly and put on latex, powder-free gloves before collection. To avoid contamination, DO NOT touch the subject s hands. The collector should use one hand to grasp the subject s arm above the wrist during the collection procedures. The ICP-MS and AAA components of this kit contain a weak acid solution (5% nitric acid). Follow the safety recommendations contained in the MSDS. In very rare cases, this acid solution may causes skin and eye irritation in sensitive individuals. Instruct the subject to wash his hands thoroughly AF- TER they have been swabbed with the ICP-MS or AAA components. SEM PROCEDURE (Adhesive Lifts) The collection device consists of a plastic vial with a tightly fitting cap. The metal stubs in the caps are equipped with a carbon adhesive tab used for lifting residue. Remove the cap from the vial. There is no tab cover to remove. The device is now ready for use. Once the collecting surface is exposed, take care not to drop the stub or contaminate the collecting surface by allowing the adhesive tab to come into contact with any object other than the area that is to be sampled. Avoid heavily soiled or bloody areas as much as possible. When pressing the stubs on the questioned areas, apply sufficient pressure to cause a slight indentation into the surface of the skin. Step 1: Right Back A. Carefully remove the cap from the vial labeled RIGHT BACK. B. Grasp subject s arm above the wrist. Do not touch subject s hands. 2 of 8

STEP 1 Rt. back STEP 2 Rt. palm C. While holding the vial cap securely, press the collecting surface of the stub onto the back of the suspect s hand until the web area shown has been covered (see Step 1 Illustration). D. After sampling the back of the suspect s hand, return the cap to the RIGHT BACK vial. Step 2: Right Palm Repeat the procedure described in Step 1 using the metal stub in the vial labeled RIGHT PALM. Be certain to sample the area of the palm. 3 of 8

Step 3: LEFT BACK/LEFT PALM For collection from the left hand, repeat Steps 1 and 2 using the vials labeled LEFT BACK and LEFT PALM. Step 4: After sampling all four areas, return the capped vials to the kit box. Final Instructions: A. Fill in all of the information required on the enclosed DATA SHEET, and place it in the kit box. B. With the exception of the gloves, return components to the kit box. Dispose of the gloves according to accepted practices. C. Reassemble the kit box, affix the Integrity Seals where indicated on the kit box top, and initial both seals. D. Complete all forms required by the agency designated to examine the kit. E. Submit the kit and completed forms to the designated agency. ICP-MS and AAA PROCEDURE (Hand Wipings) Perform ICP-MS or AAA gunshot residue collection only after sampling with the adhesive stubs (SEM procedure). If there is any possibility of glove contamination during the adhesive stub procedure, discard the gloves, thoroughly wash hands with soap and water, and dry with clean towels. At no time during the collection process should the collector s hands come into contact with the cotton tip of the swabs to be used during this procedure. Put on a fresh pair of gloves before proceeding. To swab the suspect s hands, the investigator should grasp the subject s arm above the wrist with one hand and swab with the other. The suspect s hand should be in a spread position. Thoroughly swab the hands using moderate pressure. Rotate the swab during this procedure to ensure that the entire surface of 4 of 8

the cotton tip is used. Swab each area for a minimum of 30 seconds. When dispensing the nitric acid, use 2-3 drops of the solution to moisten each swab. DO NOT OVER MOISTEN! In order to dispense an appropriate amount of acid solution, hold the acid dispenser in a horizontal position above almost touching the cotton tip of the swab, and squeeze gently. Always put cotton swabs tip down when placing swabs in tubes. Step 5: Control Swabs Remove both swabs from the unmarked zip lock bag. Moisten both swabs with the 5% nitric acid supplied with the kit (do not substitute this solution). Place both swabs in the tube labeled CON- TROL. Recap the tube and set it aside. Step 6: Left Back NOTE: You MUST use TWO swabs for each area of the hand. Moisten the tip of one swab with 2-3 drops of acid, then thoroughly swab the back of the subject s left hand including the back of the fingers and all of the web area which would be exposed while holding a weapon. Place swab used into the tube labeled LEFT BACK and repeat the above procedure using a second swab. Place the second swab used in the LEFT BACK tube, then recap tube and set it aside. 5 of 8 STEP 6 Collection from back of left hand.

Step 7: Left Palm NOTE: You MUST use TWO swabs for each area of the hand. Moisten the tip of one swab with 2-3 drops of acid, then thoroughly swab the palm of the suspect s left hand including the fingers and all of the web area which would be exposed while holding a weapon. Place the swab into the vial labeled LEFT PALM and repeat the above procedure using a second swab. Place the second swab used in the LEFT PALM tube, then recap tube and set it aside. Step 8: Right Back/Right Palm Follow the same procedures described in Steps 6 and 7 to swab the suspect s right hand. Step 9: Cartridge Case NOTE: For.22 caliber and foreign manufactured ammunition, it is necessary to complete Steps A and B described below, or submit the casings to the testing laboratory. If latent print processing STEP 7 Collection from palm of left hand. has not been completed on the expended casing(s), Steps A and B should be omitted and the casings should be submitted for latent print processing. NOTE: You MUST use TWO swabs on each cartridge case. If for any reason the Cartridge Case Swabs are not used, mark the tube NOT USED. Moisten the tip of one swab with 2-3 drops of 5% nitric acid, then thoroughly swab the INSIDE of the 6 of 8

cartridge case. Place this swab in the tube labeled CARTRIDGE CASE. If necessary, you can repeat this procedure with a second moistened cotton swab. Recap the tube and set it aside. Final Instructions: A. Fill in all of the information required on the enclosed DATA SHEET, and place it in the kit box. B. With the exception of the 5% nitric acid dispenser and the gloves, return components to the kit box. Dispose of the 5% nitric acid dispenser and the gloves according to accepted practices. C. Reassemble the kit box, affix the Integrity Seals where indicated on the kit box top, and initial both seals. D. Complete all forms required by the agency designated to examine the kit. E. Submit the kit and completed forms to the designated agency. 7 of 8

SIRCHIE PRODUCTS VEHICLES TRAINING 100 Hunter Place, Youngsville, NC 27596 USA 919-554-2244 800-356-7311 www.sirchie.com 8 of 8