decorative columns and brackets range

Similar documents
BBC Local Democracy Reporter allocation

Workless households for areas across the UK in 2010

STAMP IDENTIFICATION NUMBERS

School improvement monitoring and brokering grant provisional allocations for illustrative purposes

S31 Grant determination for a high needs strategic planning fund in : DCLG ref 31/2916

Healthwatch is the independent champion for people who use health and social care services.

Suitability of the subsurface for infiltration SuDS in Great Britain

Planned Expenditure by Local Authorities: Services for Young People

Numbers achieving 3 A grades in specific A-Level combinations by school type and LEA

NHS South Warwickshire CCG

Visitor Attractions Trends in England 2014

aeris medium & large A eris Landscaped areas Car parks Amenity areas Town squares Retail parks Entrance roads Parks

Visitor Attractions Trends in England 2017

Visitor Attractions Trends in England 2016

PQ Local Authorities with exceedances of NO 2 annual mean limit value (based on 2015

Table 4.1 Organisation and management

Winners of the Exemplar Awards 2016

AUTHORITY Central Bedfordshire Bedford Mid and South Bedfordshire Luton Bracknell Forest Reading Slough W Berkshire Windsor & Maidenhead Wokingham

2016-BASED HOUSEHOLD PROJECTIONS

Counties and unitary authorities in England 167. NUTS levels 1, 2 and 3 in England,

#element of bullying / harassment South West 2gether NHS FT Mental Health Small

Annex 3: CCGs confirmed for waves 1, 2, 3 and 4 for authorisation

Regional Volunteer registration form

NATIONAL OFFICERS AND EXECUTIVE MEMBERS

England screening uptake rates

Q Embargoed until March 2010

Swine Flu Weekly Vaccine Uptake 2009/10 - Frontline HCWs (Primary Care Organisations) Week 4 w/e 31/01/2010 For organisations under HPA

Most regions saw price falls during 2012

Oriel 2018 (2019intake) Hospital and Health Board Employers

House prices fall in most regions during the third quarter

CHAPLAINCY COSTS SURVEY, ENGLAND

House prices in London continue to climb

Simply better procurement. User Guide. National Framework for Medium Works

Dear Louise. I can confirm that the full list of approved sites for this study is:

Passport applications via a German Honorary Consul in the United Kingdom

CCG Annual Assessment 2017/18

Area1 Area Code Cut-off Date In Bank Date Area North East Essex. 28th 14th Mid Essex South East Essex

Passport applications via German Honorary Consuls in the United Kingdom

Patients. Geography: Unitary Authorities, Counties and other areas. Administrative area geography in England and Wales. Unitary Authorities

Strategic Estate Advisers Contact Details

The local elections of 1 May 1997

Research Note th June Council liabilities

Council Performance Ratings 2010

Regional Growth Tracker Q1 2015

Application and Agreement Form

Patterns of housing wealth inequality in Wales, Scotland and Northern Ireland

2018 TOWN HALL RICH LIST. Theo Hutchinson April 2018

Specialised perinatal community team that meets Perinatal Quality Network Standards Type 1

Technical specification: BS 4449:2005 GRADE B500B BAR AND COIL

*** STRICTLY EMBARGOED UNTIL 7.00AM THURSDAY 2 APRIL 2009 *** Price falls across all regions in Q1 2009

The RSPB National Swift Inventory Annual Report 2014

Money Advice Service Over-Indebtedness 2017

Local Authority to Jobcentre Plus District

Results of Devolution Referendums (1979 & 1997)

00: Not for broadcast or publication before 00:01 Hrs Monday 20th June 2011

Introduction to European Commission Funding: ERDF and JESSICA

Council Tax since

For information. The information in this circular does not affect the content of the HB Guidance Manual.

business register and employment survey ONS Crown Copyright Reserved [from Nomis on 15 February 2011]

Business bailiff instructions

Ultimate Choice for Two

Developing balanced local skills strategies. Francesca Froy, LEED Programme, OECD

Census 2011: City snapshot

Grant in Aid funding allocated to Risk Management Authorities. in 2016/17

Counting the Costs. Accident Statistics 1999 FIREWORKS ARE EXPLOSIVES. GET WISE OR GET HURT. The 1999 Accident Figures.

Birmingham B20 B20. Darlington DL17 DL17 Durham DH4 DH4. Newcastle upon Tyne NE6 NE6. Sunderland SR2 SR2 Teesside TS3 TS3

UK Data Archive Study Number New Earnings Survey Panel Dataset: Secure Access

LOCAL AUTHORITY PROJECTS ENDORSED BY THE INTERDEPARTMENTAL PROJECT REVIEW GROUP (PRG

CAA Passenger Survey Report 2017

Primary Care Support England. The National Engagement Team (NET)

City employment: An overview from the Business Register & Employment Survey (BRES)

p r o d u c t s Folding walls Glass folding walls

E: Population VISUALS

Clinical Guideline 042. Dementia: supporting people with dementia and their carers. Costing template. Implementing NICE-SCIE guidance in England

Ultimate Choice for Her

Average house price in England and Wales in June stood at 303,960

Sixth Form University Open Days

Care Home Live Bed State System. North East & North Cumbria UEC Network. Jonathan Maloney Programme Director. 5 th July 2018

The local elections of 4 May Research Paper 95/ May 1995

House Price Index Monthly Change % Annual Change % Annual % (excluding London & the SE) 304,

Local Authority codes

Funding for Better Care Fund : Disabled Facilities Grant element

Bodies listed under the Redundancy Payments (Continuity of Employment in Local Government, etc) (Modification) Order 1999

NHS England Statistical Release Breastfeeding Initiation & Breastfeeding Prevalence 6-8 weeks Quarter /16 24th September 2015 Crown Copyright

Living Rents. 4th quartile earnings. Local Authority

POLICE GRANT REPORT ENGLAND AND WALES 2018/19 TABLES. Table 1: Provisional change in total direct resource funding compared to 2017/18

NRPSI Newsletter January 2009

List of Sharer Organisations (Updated December 2017)

List of Sharer Organisations (Updated April 2013)

IMPRISONMENT IN WALES: A BREAKDOWN BY LOCAL AUTHORITY (JUNE 2018)

FINAL POLICE GRANT REPORT ENGLAND AND WALES 2019/20 TABLES

FIRE RESEARCH STATION

Happy and healthy Hart tops 2012 Quality of Life Survey

CoStar Awards Submission Criteria & Market Boundaries

NEWS RELEASE. GB Drink Drive Trends Revealed. From Release Reference Date

Average house price in England and Wales now 302,251

Annual Survey of Hours and Earnings, Office for National Statistics.

Developing Geographical Lead Responsibilities for English Spinal Cord Injury Centres. A Report of the CRG in Spinal Cord Injury

75,402 sq ft. 88,866 sq ft NOTTINGHAM. panattoni park CONSTRUCTION UNDER. Two industrial/warehouse units TO LET AVAILABLE Q3 2018

Happiness is a town called Harrogate destination named happiest place to live for THIRD year running

Transcription:

decorative columns and brackets range

02 From decorative styles that enhance or standard styles to discreetly blend in, the Holophane columns and brackets range has been exclusively designed to complement our extensive luminaire range. The entire range has been designed in accordance with EN40 to give you the confidence of design you would expect from Holophane. noah rohan With a decorative range that consists of four carefully crafted styles in three different heights (5m, 6m & 8 metres) you can be sure that combining these with the striking designs of our luminaires is unsurpassed in meeting modern lighting criteria.

03 decorative columns and brackets range isobel dominic

04 noah rohan

05 isobel dominic

06 noah isobel rohan Holophane decorative conical steel columns 8m 7m 6m 5m 4m 3m 2m 1m bracket isobel dominic isobel rohan luminaire QSM QSS vista junior seattle street

07 dominic Suitable for these Holophane luminaires: QSM petxina QSS vista seattle street urbandeco signature II vista junior denver pole noah noah dominic isobel rohan bracket vista signature II denver pole urbandeco petxina luminaire

08

ordering details 09

10 ordering Holophane decorative conical steel columns Code DPSDC VSTDC PETDC QSMDC QSSDC SLSDC VSJDC SIGDC UBDDC Denver Pole decorative conical steel column Vista decorative conical steel column Petxina decorative conical steel column QSM decorative conical steel column QSS decorative conical steel column Seattle Street decorative conical steel column Vista Junior decorative conical steel column Signature II decorative conical steel column Urbandeco decorative conical steel column Code Luminaire mounting height.5 5 metres.6 6 metres.8 8 metres Code Wind Zones as EN40 For extra heavy area wind zones (EN40 Rationalised Wind Zones) Code Brackets.1A Single head.2a Twin head Code Brackets.VAQ Isobel design 0 tilt.vcv Dominic design 5 tilt.vbb Rohan design 10 tilt.vll Noah design 5 tilt Code Options.FB1 Flange Base 5-8m noah isobel rohan dominic Orderings codes for the Holophane standard column range (conical steel, conical aluminium, tubular base and conical steel mid hinged) can be found in the appropriate Holophane product brochure, or alternatively visit www.holophane.co.uk

technical details for decorative and standard ranges 11

12 technical decorative conical steel columns and brackets ordering ø J I Ko Flange Plate B 400 A 300 F FB1 H ground level G C 150 x 75 cable entry E D The column dimensions for all decorative brackets are as above.

13 technical I Ko I Ko Rohan Twin (VBB) Rohan (VBB) J Ko I I I Isobel (VAQ) Noah (VLL) Dominic (VCV) Height (m) Nominal Height Total Height Base Diameter Root Diameter Planting Depth Column Length Door to Ground Door Outreach Length Mounting Diameter drawing ref A B C D E F G H I J Ko 5m (VAQ) 5000 6200 161 175 800 4850 425 400 x 85 1000 60 0 5m (VBB) 5000 6250 161 175 800 4850 425 400 x 85 1200 b 10 5m (VLL) 5000 6250 161 175 800 4850 425 400 x 85 1000 60 0 5m (VCV) 5000 6250 161 175 800 4850 425 400 x 85 1000 60 5 6m (VAQ) 6000 7200 178 195 1000 6050 425 400 x 85 1000 60 0 6m (VBB) 6000 7250 178 195 1000 6050 425 400 x 85 1200 60 10 6m (VLL) 6000 7250 178 195 1000 6050 425 400 x 85 1000 60 0 6m (VCV) 6000 7250 178 195 1000 6050 425 400 x 85 1000 60 5 8m (VAQ) 8000 9200 212 233 1200 8250 425 500 x 100 1000 60 0 8m (VBB) 8000 9250 212 233 1200 8250 425 500 x 100 1200 60 10 8m (VLL) 8000 9250 212 233 1200 8250 425 500 x 100 1000 60 0 8m (VCV) 8000 9250 212 233 1200 8250 425 500 x 100 1000 60 5 Uplift Angle 5-8m Poles Flange Plate FB1 Bolts M18 x 400 Flange Plate and J-Bolt information will be confirmed at time of order due to the necessity in ensuring the correct plate and J-Bolts are supplied.

14 technical standard columns conical aluminium Holophane products that are suitable B aeris large aeris medium denver pole petxina QSM QSS seattle flood Flange Plate 400 signature II urbandeco vista 300 A E vista junior FB2 270 200 H FB1 G F ground level 500 150 x 75 cable entry D C Height (m) Nominal Height Top Diameter Root End Diameter Planting Depth Overall Length Door to Ground Door Opening Length drawing ref A B C D E F G H Door Opening Width Weight kg* Bending Moment Nm 3m std 3000 75 150 800 3800 600 600 100 15 5340 4m std 4000 75 150 800 4800 600 600 100 18 5070 5m std 5000 75 150 800 5800 600 600 100 21 4940 6m std 6000 75 150 1000 7000 600 600 100 25 4870 8m std 8000 75 165 1200 9200 600 600 100 38 6900 8m hd 8000 75 180 1200 9200 600 600 100 43 9120 10m std 10000 75 200 1500 11500 600 600 100 72 16190 * Exclusion TBC 3-6m Poles Flange Plate FB1 Bolts M18 x 330 8-10m Poles Flange Plate FB2 Bolts M18 x 330 Flange Plate and J-Bolt information will be confirmed at time of order due to the necessity in ensuring the correct plate and J-Bolts are supplied. std = Standard hd = Heavy Duty Column type to be confirmed at time of order as this is based on luminaire weight, windage and geographical location.

15 standard columns conical steel technical Holophane products that are suitable Flange Plate 400 B aeris large aeris medium caribe chalfont denver pole grosvenor gladiator petxina prismasphere QSM QSS seattle flood signature II urbandeco vista vista grande vista junior FB3 412 FB2 260 200 300 300 I A F H FB1 ground level C 150 x 50 cable entry G 500 E D Height (m) Nominal Height Top Diameter Base Diameter Root End Diameter Planting Depth Overall Length Door to Ground Door Opening Length Door Opening Width Weight kg* Bending Moment Nm drawing ref A B C D E F G H I 3m std 3000 76 127 141 800 3800 425 400 85 33.68 5040 4m std 4000 76 118 126 800 4800 425 400 85 39.08 3890 4m hd 4000 76 133 144 800 4800 425 400 85 40.08 5640 5m std 5000 76 128 136 800 5800 425 400 85 49.45 4900 5m hd 5000 76 147 158 800 5800 425 400 85 51.65 6960 6m std 6000 76 138 148 1000 7000 425 400 85 65.84 5800 6m hd 6000 76 161 175 1000 7000 425 400 85 67.39 8070 8m std 8000 76 158 170 1200 9200 425 500 100 119 11920 8m hd 8000 76 189 206 1200 9200 425 400 85 124.45 18000 10m std 10000 76 178 193 1500 11500 425 500 100 160.04 16320 10m hd 10000 76 217 238 1500 11500 425 500 100 175.04 23230 * Exclusion TBC 3-5m Poles Flange Plate FB1 Bolts M18 x 330 6-8m Poles Flange Plate FB2 Bolts M24 x 400 10m Poles Flange Plate FB4 Bolts M24 x 650 Flange Plate and J-Bolt information will be confirmed at time of order due to the necessity in ensuring the correct plate and J-Bolts are supplied. std = Standard hd = Heavy Duty Column type to be confirmed at time of order as this is based on luminaire weight, windage and geographical location.

16 technical standard columns stepped steel Holophane products that are suitable J I aeris large aeris medium ashbourne caribe chalfont denver pole dorchester Flange Plate 430 grosvenor K gladiator hallbrook module 600 300 A E parkpack petxina FB2, FB3 prismasphere 260 predator small predator large QSM 200 QSS seattle flood signature II FB1 H G C sherington urbandeco ground level F vista vista grande 150 x 75 cable entry 500 D vista junior woburn B Height (m) Nominal Height Base Diameter* Base Height Planting Depth Overall Length Door to Ground Door Opening Length Door Opening Width Spigot Length* Spigot Diameter* Shaft Diameter* Weight kg* Bending Moment Nm drawing ref A B C D E F G H I J K 3m std 3000 140 1075 800 3800 425 500 100 76 28.42 TBC 4m std 4000 140 1075 800 4800 425 500 100 76 32.96 6500 4m hd 4000 168 1250 800 4800 425 500 100 130 76 89 51.6 9865 5m std 4700 140 1075 800 5500 425 500 100 76 36.13 6200 5m hd 4700 168 1075 800 5500 425 500 100 130 76 89 50.7 9865 6m std 5700 140 1075 1000 6700 425 500 100 76 42.69 6000 6m hd 5700 168 1075 1000 6700 425 500 100 130 76 89 60.07 9550 8m std 7700 168 1250 1200 8900 500 600 115 130 76 89 77.30 10100 8m hd 7700 168 1250 1200 8900 500 600 115 250 102 114 96.32 14000 10m std 9700 168 1250 1500 11200 500 600 115 250 102 114 142.1 17820 10m hd 9700 194 1250 1500 11200 500 600 115 250 127 140 141.61 21250 12m std 11700 194 1250 1700 13400 500 600 115 250 127 140 165.58 21000 * Exclusion TBC 3-6m Poles Flange Plate FB1 Bolts M18 x 330 6m Poles Flange Plate FB2 Bolts M24 x 400 8m Poles Flange Plate FB3 Bolts M24 x 400 10-12m Poles Flange Plate FB4 Bolts M24 x 650 Flange Plate and J-Bolt information will be confirmed at time of order due to the necessity in ensuring the correct plate and J-Bolts are supplied. std = Standard hd = Heavy Duty Column type to be confirmed at time of order as this is based on luminaire weight, windage and geographical location.

17 standard columns mid-hinged steel technical Holophane products that are suitable aeris large aeris medium caribe chalfont denver pole dorchester gladiator grosvenor module 600 parkpack petxina predator small predator large prismasphere QSM QSS seattle flood signature II urbandeco vista vista grande vista junior Flange Plate 412 300 FB2 Height (m) Nominal Height Top Diameter Base Diameter Root End Diameter Planting Depth Overall Length Door to Ground Door Opening Length Door Opening Width Weight kg* Bending Moment Nm drawing ref A B C D E F G H I 4m std 4000 76 116 137 800 4800 425 400 85 43.5 4480 4m hd 4000 76 132 144 800 4800 425 400 85 49.8 5640 5m std 5000 76 126 142 800 5800 425 400 85 53.4 5330 5m hd 5000 76 147 158 800 5800 425 400 85 63.7 6960 6m std 6000 76 136 146 1000 7000 425 400 85 68.6 6200 6m hd 6000 76 161 175 1000 7000 425 400 85 87.3 8070 8m std 8000 76 156 168 1200 9200 425 500 100 150.1 4760 8m hd 8000 76 189 206 1200 9200 425 400 85 167.65 12370 10m std 10000 76 176 193 1500 11500 425 500 100 203.24 TBC 10m hd 10000 76 217 238 1500 11500 425 TBC TBC 218.24 TBC * Exclusion TBC 4-5m Poles Flange Plate FB1 Bolts M18 x 330 6-10m Poles Flange Plate FB2 Bolts M24 x 400 Flange Plate and J-Bolt information will be confirmed at time of order due to the necessity in ensuring the correct plate and J-Bolts are supplied. std = Standard hd = Heavy Duty Column type to be confirmed at time of order as this is based on luminaire weight, windage and geographical location.

18 technical J-anchor bolts For foundation detail guidance refer to Holophane. For columns supplied with optional flange base Holophane offer three types of foundation bolts. Note: The material used for the bolts is equivalent to GR40 type steel, with yield strength 236 N/M2. HEL.FS1 HEL.FS2 HEL.FS3 HEL.FS4 M18 Bolts (FS1) x 330 mm long M24 Bolts (FS2) x 400 mm long M24 Bolts (FS3) x 650 mm long M27 Bolts (FS4) x 630 mm long 330 ± 6 400 ± 10 650 ± 10 630 75 100 85 95 ± 2.FS1.FS2.FS3.FS4

19 technical data EN40 guidelines

MERTHYR TYDFIL THE VALE OF GLAMORGAN BLAENAU GWENT CARDIFF SEFTON NEWPORT BLACKBURN WITH DARWEN KNOWSLEY HALTON NORTH SOMERSET WARRINGTON STOCKPORT CITY OF BRISTOL BATH AND NE SOMERSET CITY OF STOKE-ON- TRENT WOKINGHAM BRACKNELL FOREST MILTON KEYNES SLOUGH WINDSOR AND MAIDENHEAD CITY OF KINGSTON UPON HULL NORTH EAST LINCOLNSHIRE 20 EN40 EN40 Guidelines Products affected by EN40 Refer to Holophane Lighting columns for lanterns up to 20 metres. Post top mounted. Columns for side entry luminaires up to 18 metres. NA H-EILEANAN AN IAR HIGHLAND MORAY A B E R D E E N S H I R E ABERDEEN CITY SHETLAND ISLANDS Dashed lines are for clarification purposes only. ORKNEY ISLANDS ANGUS PERTH AND KINROSS DUNDEE CITY Parameters of EN40 Wind Speeds ARGYLL AND BUTE STIRLING CLACKMANNANSHIRE WEST DUNBARTONSHIRE EAST DUNBARTONSHIRE FIFE Sites Structural Strength 1 2 3 4 NORTH LANARKSHIRE FALKIRK WEST LOTHIAN EAST 5 LOTHIAN MIDLOTHIAN The Sites Terrain Category I Sea sides. At the edge of a lake with a length exposed to the wind of at least 5km. Flat, even land without obstacles. Terrain Category II Fenced off cultivated land, some small agricultural buildings, houses or trees. Terrain Category III Industrial or sub-urban zones and forests. Terrain Category IV - Urban perimeters with at least 15% of the surface built on and/or on which the average of buildings exceed 15m. For simplicity, Holophane have grouped lighting columns for administrative areas designated in PD 6547 table A.1, for Light Wind Zones and Medium Wind Zones under one reference, LMZ. For Heavy Wind Zones the reference is HVZ and for Extra Heavy Wind Zones the reference is HEZ. FERMANAGH TYRONE DERRY / LONDONDERRY ARMAGH 1 INVERCLYDE 2 RENFREWSHIRE 3 EAST RENFREWSHIRE 4 GLASGOW CITY 5 EDINBURGH CITY 6 LIVERPOOL 7 BOLTON 8 SALFORD 9 TRAFFORD 10 ROCHDALE 11 MANCHESTER 12 TAMESIDE 13 OLDHAM 14 CITY OF WOLVERHAMPTON 15 WALSALL 16 SANDWELL 17 DUDLEY 18 BIRMINGHAM 19 SOLIHULL 20 COVENTRY ANTRIM DOWN NORTH AYRSHIRE PPEMBROKESHIRE SOUTH AYRSHIRE ISLE OF ANGLESEY EAST AYRSHIRE GWYNEDD CERE D IGION SWANSEA SOUTH LANARKSHIRE D U M F R I E S A N D G A L L OWAY CARMARTHENSHIRE CONWY NEATH PORT TALBOT DEVON BRID GEND POWYS RHONDDA, CYNON, TAFF BLACKPOOL DENBIGHSHIRE FLINTSHIRE CAERPHILLY WIRRAL TORFAEN SCOTTISH BORDERS CUMBRIA 6 WREXHAM MONMOUTHSHIRE LANCASHIRE BRADFORD LEEDS CALDERDALE WAKEFIELD 10 KIRKLEES 7 13 DONCASTER BARNSLEY 8 11 12 9 ROTHERHAM ST HELENS TELFORD AND WREKIN WIGAN COUNTY OF HEREFORDSHIRE SOMERSET BURY CHESHIRE SHROPSHIRE NORTHUMBERLAND SOUTH GLOUCESTERSHIRE DORSET NEWCASTLE UPON TYNE GATESHEAD STOCKTON-ON-TEES STAFFORDSHIRE 14 15 16 17 18 WORCESTERSHIRE DURHAM GLOUCESTERSHIRE POOLE DARLINGTON SHEFFIELD DERBYSHIRE CITY OF DERBY WILTSHIRE 19 20 SWINDON CITY OF SOUTHAMPTON BOURNEMOUTH NORTH TYNESIDE SOUTH TYNESIDE SUNDERLAND WARWICKSHIRE HARTLEPOOL MIDDLESBROUGH NORTH YORKSHIRE ISLE OF WIGHT YORK CITY OF NOTTINGHAM CITY OF LEICESTER OXFORDSHIRE WEST BERKSHIRE NOTTINGHAMSHIRE LEICESTERSHIRE READING HAMPSHIRE REDCAR AND CLEVELAND EAST RIDING OF YORKSHIRE CITY OF PORTSMOUTH NORTH LINCOLNSHIRE RUTLAND NORTHAMPTONSHIRE BUCKINGHAMSHIRE LINCOLNSHIRE CITY OF PETERBOROUGH BEDFORDSHIRE LUTON SURREY WEST SUSSEX CAMBRIDGESHIRE HERTFORDSHIRE London CITY OF BRIGHTON & HOVE ESSEX THURROCK EAST SUSSEX NORFOLK MEDWAY KENT SUFFOLK SOUTHEND-ON-SEA CORNWALL CITY OF PLYMOUTH TORBAY 0 50 100 km Boundaries revised to April 2001 Crown copyright 2001 ISLES OF SCILLY

21 EN40 EN40 Rationalised Wind Zones (PD6547) 2004 Light & medium areas Holophane code: Heavy areas Holophane code: Extra heavy areas Holophane code: Aberdeen Aberdeenshire Angus Antrim Argyll & Bute Armagh Bath & North East Somerset Bedfordshire Blackburn & Darwen Blackpool Blaenau Gwent Bournemouth Bracknell Forest Bridgend Brighton & Hove Bristol Buckinghamshire Caerphilly Carmarthenshire Cambridgeshire Cardiff Ceredigion Channel Islands Cheshire Clackmannanshire Conwy Cornwall Cumbria Darlington Denbighshire Derby Derbyshire Devon Dorset Down Dumfries & Galloway Dundee Durham East Ayrshire East Dunbartonshire East Lothian East Renfrewshire East Riding of Yorkshire East Sussex Edinburgh Essex Falkirk Fermanagh Fife Flintshire Glasgow Gloucestershire Greater London Greater Manchester Gwynedd Halton Hampshire Hartlepool Herefordshire Hertfordshire Highland Inverclyde Isle of Anglesey Isle of Man Isle of Wight Isles of Scilly Kent Kingston upon Hull Lancashire Leeds City Leicester Leicestershire Lincolnshire Londonderry Luton Medway Merseyside Merthyr Tydfil Mid Lothian Middlesbrough Milton Keynes Monmouthshire & Newport Moray Neath Port Talbot Norfolk North Ayrshire North East Lincs North Lanarkshire North Lincs North West Somerset North Yorkshire Northamptonshire Northumberland Nottingham Nottinghamshire Orkney Oxfordshire Pembrokeshire Perth & Kinross Peterborough Plymouth Poole Portsmouth Powys Reading Redcar & Cleveland Renfrewshire Rhondda Cynon Taff Rutland Scottish Borders Shropshire Slough Somerset South Ayrshire South Gloucester South Lanarkshire South Yorkshire Southampton Southend Staffordshire Stirling Stockton on Tees Stoke-on-Trent Suffolk Surrey Swansea Swindon Telford and Wrekin Thurrock Torbay Torfaen Tyne and Wear Tyrone Vale of Glamorgan Warrington Warwickshire & Coventry West Berkshire and Newbury West Dunbartonshire West Lothian West Midlands West Sussex West Yorkshire Western Isles Wiltshire Windsor & Maidenhead Wokingham Worcestershire Wrexham York

22 Disclaimer Holophane columns of 8m and above are suitable for Terrain Category II to IV, as specified in EN 40, whereas columns below 8m are suitable for location of Terrain Category III and IV only. While it is the purchasers responsibility to specify the Terrain Category for the location of the columns, it is considered that the Terrain Categories specified above, which are recommended in PD 6547 (guidance on the use of EN 40), will be suitable for the vast majority of lighting columns installed within the UK. It is of course possible that a small number of columns will be installed in more severe Terrain Categories than those above. Such locations include coastal sites (within 5Km of the coast), columns mounted on elevated locations such as bridges or installed on sites above 250m altitude. Locations with known local wind funnelling also need to be considered as a special case. Where special conditions exist or there are concerns that columns designed for the standard Terrain Categories detailed above may not be suitable, please contact your local Holophane Sales Engineering who will pass your specific site details to our Unique Solutions Department. The information required to ensure a suitable column is specified for your particular set of circumstances is. The addition of locally applied signs and banners can significantly increase the load on the column. In such cases, a higher specification column is likely to be required. Please give your local Holophane Engineer details of the additional loading you wish to apply, i.e. maximum area and mounting height. In the case of light strings (Christmas lights) the weight/m, distance of the span and the minimum centre sag dimension you will be installing. Under no circumstances should lighting columns be drilled or additional items welded to columns as this will locally reduce the strength of the column and may cause a significant safety hazard. Mounting height. Column type e.g. Conical Number and type of luminaire. Bracket type if appropriate Administrative area of installation. Altitude if above 250m. Details of site including any relevant or special conditions. Mounting method - direct embedment or flange base.

Holophane Europe Limited Bond Avenue, Bletchley, Milton Keynes MK1 1JG United Kingdom Telephone: +44 ( 0 ) 1908 649292 UK Fax: +44 ( 0 ) 1908 367618 International Fax: +44 ( 0 ) 1908 272029 E-mail: info@holophane.co.uk www.holophane.co.uk decorative columns and brackets range Publication No. CB 0314 UK