Cooking Booth Construction and Location (See Figure 1 and 2 for diagrams):

Similar documents
FIRE REGULATIONS FOR OUTDOOR FESTIVALS CONCESSION BOOTHS (See Tents and Canopies Information Bulletin)

Marin County Fire Department. Fire Protection Standard 119. Tents and Awnings

TENTS, CANOPIES AND TEMPORARY MEMBRANE STRUCTURES

Bodega Bay Fisherman s Festival Food Vendor Information/Application

Inspection Check-off Sheet

Tents & Membrane Structures Information Packet

Clovis Fire Department

CODE SUMMARY TENTS AND OTHER MEMBRANE STRUCTURES

APPLICATION TO ERECT A TEMPORARY TENT OR CANOPY Fee: $147.00

EXCELSIOR FIRE DISTRICT

Outdoor Tent Permit Requirements

Tent Policy & Procedures for Washington University in St. Louis

Tents and Air Supported Membrane Structures

USE OF TENTS Guide. Frederick County Fire and Rescue Services Division. Office of the Fire Marshal

Tent /Membrane Structure Permit Application

Permit Application Requirements For Temporary Tents, and Membrane Structures

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

SPECIAL EVENTS --- TENTS --- COOKING

Tent Policy & Procedures for Danforth, North, West and South Campuses at Washington University in St. Louis

F I R E D E P A R T M E N T SANTA CLARA COUNTY

STANDARD DETAILS & SPECIFICATIONS

SUNY GENESEO ENVIRONMENTAL HEALTH AND SAFETY

Simplified Guide to Fire Prevention - Exhibition. March 2014 issue

Osceola County Department of Fire Rescue and Emergency Medical Services

Looking forward to a great Fair

TENT AND CANOPY POLICY

This document has changed! Please read carefully before signing!

Temporary Structure Permit Guide

EXCELSIOR FIRE DISTRICT

SFM HCD DSA OSHPD T-24 T-19* 1 2 1/AC AC SS

APPLICATION FOR TENTS/INFLATABLES

State of California Health and Human Services Agency California Department of Public Health

Flammable and Combustible Liquids. OSHA Office of Training and Education 1

PATHFINDER CAMP SAFETY INSPECTION FORM

TENT PERMIT APPLICATION AND CHECKLIST

Amber Long. Chief Pomeroy,

- Tents larger than 10 x 12 require a permit from Santa Rosa Island Authority and may require a permit from Escambia County, for inquiry.

COMMUNITY EVENTS PERMIT APPLICATION. Address to which Permit can be mailed:

University of California, Davis TEMPORARY FOOD FACILITY APPLICATION THIRD PARTY VENDOR

For Outdoor Use Only!

For Outdoor Use Only!

Style # Laguna Propane Tank Cover Owner s Manual

Required. When application not signed by owner Permit Fee V As per Fee By-law

10' x 20' MAX AP CANOPY EXTENSION KIT Assembly Instructions

Vendor Requirements Bikes Blues & BBQ

Colonial and Grand Colonial Fire Pit Tables. Installation Instructions for

TWO BURNER STAINLESS STEEL PROPANE STOVE

LP Grill and Gas Hose

Building Permit Application

Temporary Structure/Use Checklist

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

PROPANE SAFETY CHARACTERISTICS OF PROPANE

Camping Chef Folding Elite Camping Chef Folding Compact Camping Chef Folding

Exhibitor Terms and Conditions

SINGLE BURNER STOVE IMPORTANT OPERATING INSTRUCTIONS COOKING & STORAGE POSITION PARTS IDENTIFICATION

City of Redding Airports

280 Propane Barbecue Assembly Manual

MEMORANDUM Thomas J. Kaminski

SMART BIO-ETHANOL ELECTRONIC BURNER

2018 Tooele County Fair Booth Application August 2, 3, 4 TH, 2018

Gas Conversion Kits and Instructions

BARODA TOWNSHIP OPEN BURNING ORDINANCE. Ordinance No. 35

TUBULAR BURNER CONVERSION KIT AGCK-TBXX / AECK-UBXX

EB300. Ethanol Burner. User s Manual Installation Instructions

10' x 20' MAX AP CANOPY Assembly Instructions

Assembly Instructions & User s Manual 26 Florence Folding Leg Fire Pit

Operator's Manual. Model: RY10MK-PRO MPN: RA-MLT Gallon Direct Fire Melter Kettle Burner Model with Adjustable Flame-Out Valve

VENDOR APPLICATION. Festival main address for map: Plaza DeLuna 900 S Palafox Street Pensacola, FL 32502

Assembly Instructions

10' x 20' 2-IN-1 MAX AP CANOPY & SCREEN KIT Assembly Instructions

ACCENDA Instructions for use and safety

ULTRAMAX CANOPY ENCLOSURE KIT Assembly Instructions

S.A.Q s: What are questions I should ask when contemplating into the design, specifying, or purchasing a fire pit?

Twin Basket Deep Fryer

Seattle RV SHOWS RULES & REGULATIONS

Lemont Fire Protection District Open Burning Regulations July 6, 2012

CARTARP CARTARP INSTRUCTIONS INSTRUCTION INDEX YOUR KELTY CARTARP SHOULD INCLUDE: Before you Start 2-5 Pitching your CarTarp 6-11 Notes 11 Warranty 12

Manufactured in New Zealand Metal Fab Industries Ltd PO Box Greenmount Auckland

Commander U. S. Coast Guard Eighth Coast Guard District

2018 Football Season Tailgate opens Monday, July 2, 2018.

Installer: Leave This Manual with Consumer Consumer: Save this Manual for Future Reference

INSTRUCTIONS MANUAL CAST IRON STOVE

OWNER S MANUAL 10x10 SUN SHELTER WITH NETTING

YELLOWSTONE YELLOWSTONE INSTRUCTIONS INSTRUCTION INDEX YOUR KELTY TENT SHOULD INCLUDE:

t420 Barbecue Assembly Manual

Vendor agrees that Mayfair at Cedar Crest College shall retain 20% of ticket sales income after adjusting for 6% sales tax payment by vendor.

Lit Table Top Firepit Bio-Ethanol Fireplace. User Manual. Model: GF301650

14' x 32' x 12' Round Top Round Style Shelter Assembly Instructions

Guidelines for Tents/Canopies on Campus

S420 Barbecue Assembly Manual

2 Burner ASSEMBLY MANUAL

TRAIL DOME TRAIL DOME INSTRUCTIONS INSTRUCTION INDEX YOUR KELTY TENT SHOULD INCLUDE: Before you Start 2-4 Pitching your Tent 5-7 Notes and Warranty 8

12 Holiday Safety Tips continued

Please read this manual before installation and use. We wish you many years of pleasure and warmth.

ASSEMBLY GUIDE. Customer Service: INCH² 2-BURNER & 864 INCH² 2-BURNER

Sportster II Dual Fuel Stove

NATURAL GAS CONVERSION KIT

Key Largo Fire Pit. Installation Instructions. 1 P a g e. NorthlineExpress.com. Toll-Free

Temporary Campground Plan Review Application

Fire Stats Cooking Fires

Transcription:

Page: 1 Of 9 Scope: This Standard shall apply to all cooking equipment, the including but not limited to: fryers, grills, BBQ s (both solid and LPG fuel supplied) and ovens. Use in or adjacent to booths tents and awnings associated with any public or private events. This standard is promulgated pursuant to uniform fire code, California fire code and Title 19 California Code of regulations. Permits: Permits are required for outdoor carnivals and fairs. Fees are based on time required for plan reviews and/or inspections and will vary depending upon location and size of event. This standard shall apply to individual tents, temporary structures or membrane structures less than 200 square feet in area and canopies less than 400 square feet in area used as outdoor carnival and fair booths. A site plan must be submitted indicating tent size, location, use, exits, seating arrangements, fire extinguisher location, emergency lighting, and fire lanes, parking area and side streets /adjacent buildings. A Novato Fire District Permit is required for all tents and temporary membrane structures having an area in excess of 200 square feet and canopies in excess of 400 square feet (see attached permit application). Definitions: Booths Are booths where food is prepared by a heating or cooking process such as but not limited to grilling, baking, warming, and boiling. Deep fat frying Is any cooking operation or process whereby the product floats or is submerged in hot oil during the cooking process. Include all booths other than cooking booths. Booth Construction and Location (See Figure 1 and 2 for diagrams): 1. Each temporary membrane structure, tent or canopy must have a permanently affixed label bearing the size and fabric material type, the date that the material was last treated with an approved flame retardant, the trade name and type of flame retardant utilized in the treatment, and the name of the person and firm that applied the flame retardant. 2. All fabrics or membranes covering cooking booths must be certified flame retardant or treated with a fire retardant paint or spray.

Page: 2 Of 9 3. Decorative materials must be inherently fire resistive, or must be treated with a fireretardant paint or spray. 4. Flooring material used within a cooking booth and under cooking equipment shall be noncombustible or fire-retardant treated. EXCEPTION: 3/8" plywood or similar material. Note: For items 1, 2 and 3, a flame test may be required for non-certified flame retardant or treated materials. A field flame test will require a sample of material measuring 2 inches by 12 inches. 5. Each cooking booth shall have at least one exit way, minimum 3 feet wide by 6'8" high (booth frame shall not obstruct exit path). 6. booths shall have a minimum clearance of 10 feet on at least two sides with clearance of at least 20 feet from any vendor booth or building. 7. A 10-foot wide separation shall be provided for every 10 connected cooking booths. Equipment: 1. All interior cooking equipment shall be of an approved type and open flame cooking shall be a minimum of 18 inches from booth back/side drop materials. 2. Camping type stoves may be used only with approved fuel under the following conditions: Do not add liquid fuel to stoves in booth. Maximum of two gallons of fuel capacity for each appliance is allowed with no additional fuel storage inside of booth. Do not use kerosene or gasoline. 3. Butane or Propane equipment shall conform to the following: appliances must have an on-off valve and located far enough away to be safely shut off in case of fire. Shut-off valves must be provided at each fuel source. Hoses must be of type approved for use with the equipment and fuel type. Tank must be protected from damage and secured in an upright position. No storage of extra butane or propane tanks is allowed in the booth. Tanks not in use must be turned OFF. Maximum quantity for use inside booths is ten gallons.

Page: 3 Of 9 The booth operator shall test all connections for leaks with a soap and water solution prior to use. Unused fuel cylinders shall be stored in a secured position. Maximum outside storage is 10 gallons. Portable Propane Containers: Each container must be kept outside of the temporary membrane structure, tent or canopy, 10 feet from any combustibles, and 10 feet from tents, secured and protected from tampering, tipping over or other hazard or damage. Note: Specialized-cooking equipment, used outside of the booth may have larger tanks, when approved by Fire Marshal, but may require greater separation. Vendor Booth Construction and Location (See Figure 3): 1. Each vendor booth shall have at least one exit way, a minimum of 3 feet wide by 6'8" high (booth frame shall not obstruct exit path). 2. Vendor booths shall have a minimum clearance of 20 feet on at least one side with clearance of at least 20 feet from any cooking booth. 3. A 10-foot wide separation shall be provided for every 200-lineal feet of vendor booths. Electrical Power: 1. Generators shall be placed in approved locations. 2. Generators or other internal combustion power sources must be separated from each temporary membrane structure, tent or canopy by a minimum of 20 feet and be isolated from contact by the public by fencing, enclosure or other approved means. 3. Refueling of generators is prohibited during event hours. No extra fuel shall be stored onsite during event hours. 4. During approved refueling times, no smoking or open flames are allowed within 25 feet of the refueling operation. 5. Extension cords shall be of a grounded type and approved for exterior use. 6. Extension cord use should be kept to a minimum. Use fused power strips to plug in appliances. Zip cords will not be allowed. 7. Cords shall be protected to prevent trips, slips and falls or other physical damage.

Page: 4 Of 9 Charcoal : 1. Use only an electric starter or commercial sold lighter fluid. 2. Charcoal cooking and storage of lighter fluid is prohibited inside booths. 3. Charcoal cooking shall be located a minimum of 10 feet away from booths and in areas away from public access. 4. Charcoal cooking shall be 10 feet away from combustible structures and parked vehicles. 5. Coals shall be disposed in metal containers approved by the authority having jurisdiction. Deep Fat Frying/Flambé/Open Flame : 1. Deep fat frying, flambé or open flame cooking operations shall be located outside the booth and no closer than 20 feet (CFC 3216.3.3) from any combustible material. 2. The cook area shall not be accessible by the general public. 3. Deep fat frying equipment must be equipped with a temperature regulating device or other method of regulating temperatures approved by the Fire Department. 4. Separation shall be maintained with a minimum of 3 feet clearance between deep fat frying and flambé or open flame cooking. 5. A K class fire extinguisher is required on site for all deep fat fryers. Fire Extinguishers: 1. Portable Fire Extinguishers: Each temporary membrane structure, tent or canopy must have a fire extinguisher with a minimum rating of 2A:10B:C. The extinguisher must have a current State Fire Marshal s tag attached indicating that it has been serviced and inspected. Extinguishers must be placed in a location that is readily available and not blocked in any manner. Pressurized water fire extinguishers having a 2A rating will be required for solid fuel fired BBQ s in addition to the 2A:10B:C. 2. For vendor booths, the maximum travel distance to a fire extinguisher with a minimum rating of 2A:10B:C shall not exceed 75 feet. 3. Fire extinguishers in cooking booths shall be mounted adjacent to the exit and must be visible and accessible. 4. Fire extinguishers shall be properly maintained and serviced. 5. Each generator shall be provided with a fire extinguisher with a minimum 40B:C rating. The extinguisher shall be located near the generator and accessible at all times.

Page: 5 Of 9 Sources of Ignition: 1. Keep all combustibles away from ignition sources. Smoking shall not be permitted inside any temporary membrane structure, tent or canopy. NO SMOKING signs must be conspicuously posted. No candles or open flame will be permitted in tents unless specifically permitted an approved by the Fire Marshal. Housekeeping: 1. The floor surface inside a temporary membrane structure, tent or canopy and the perimeter shall be kept clear of combustible waste. 2. All compressed gas cylinders shall be secured in an upright position. 3. Clean all cooking areas regularly to prevent the build-up of grease. Fire Safety: 1. Know where the fire extinguisher is and how to use it. 2. DO NOT leave cooking unattended. 3. DO NOT wear loose fitting clothing while cooking 4. Remove trash accumulation regularly. 5. Keep combustibles away from heat sources. 6. In case of emergency, DIAL 9-1-1. If using a cell phone call 892-1511 for fire or medical emergency. Fire Lanes, Access, Location, and Parking: 1. Fire apparatus access shall be provided as outlined in CFC 902.2. Access roads shall have an unobstructed width of not less than 20 feet with vertical clearance of 14 feet. 2. Temporary membrane structures, tents, and canopies shall not be located within 20 feet of buildings, property lines, parked vehicles, internal combustion engines, or other temporary membrane structures, tents, or canopies. For the purpose of determining required distances, support ropes and guy wires shall be considered as part of the temporary membrane structure, tent, or canopy.

Page: 6 Of 9 Inspections: Fire District inspections will include, but may not be limited to, the following: Tent flame resistance, portable fire extinguishers, and sources of ignition, protection and security of portable LP-gas containers, generators and housekeeping and Fire Lanes (20ft width minimum) and turn around areas, and soap test for all LPG piping and valves. Inspections will be conducted in the morning of each day prior to the event s start. Verification of the 20ft fire access lane.

Page: 7 Of 9 Figure 1 Booth Setup 10 Feet

Page: 8 Of 9 Figure 2 Booth Locations INTERNAL COMBUSTION ENGINES, GENERATOR OR PARKING PROPERTY LINES PERMANENT STRUCTURES 100 Feet Max. ASILE/EMERGENCY ACCESS ASILE/EMERGENCY ACCESS VENDOR BOOTHS 100 Feet Max. Figure 3 Vendor Booth Locations

Page: 9 Of 9 200 Feet Max-Double Row 200 Feet Max-Double Row ASILE/EMERGENCY ACCESS 200 Feet Max-Double Row 200 Feet Max-Double Row ASILE/EMERGENCY ACCESS 200 Feet Max.- Single Row VENDOR BOOTHS INTERNAL COMBUSTION ENGINES, GENERATOR OR PARKING PROPERTY LINES PERMANENT STRUCTURES Other referenced standards: Tents and Awnings