35W Single Output Switching Power Supply

Similar documents
60W Single Output Switching Power Supply

60W Single Output Switching Power Supply


320W Single Output with PFC Function


20W Single Output Switching Power Supply MODEL:LPV OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT O/P:FULL LOAD

240W Single Output with PFC Function

60W Single Output LED Power Supply MODEL:PLP OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

60W Single Output LED Power Supply

CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection

Jameco SKU Number:

Jameco SKU Number:

15W Single Output Switching Power Supply MODEL:RS OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT


62.5W Rated output power for convection; 80W with 18CFM min. forced air

50W Single Output Switching Power Supply


Test Report: EPP

Test Report: EPS 15 12

MODEL:RT-65B OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT I/P: 230 VAC O/P:FULL LOAD

600W with PFC and Parallel Function PSP-600 series

LPS 20V 24V. COLD START 40A(t width=1030 s measured at 50% I peak) <0.75mA / 240VAC

IP65 IP67 MODEL CLG CLG CLG CLG CLG CLG CLG V 15 ~ 20V 24V 18 ~ 24V

Test Report: EPP

Test Report: EDR-75-12

120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

75W Single Output with PFC Function

Test Report: APC

Test Report: IRM-05-24

PB 300/360 P 12 PB PB V 28.8V 13.6V 27.2V 26 ~ 28.8V. 40 ~ 125Ah 10.5A 6.25A

Test Report: IRM-05-05

Test Report: IRM-20-24

Test Report: IRM-10-12

Test Report: GSM40A18

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST

1000W Single Output Power Supply

1000W Single Output Power Supply

MODEL CEN CEN CEN CEN CEN CEN CEN V 24V 30V 36V 42V

Test Report: HB

1000W Intelligent Single Output Battery Charger MODEL:PB OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT.

Test Report: LCM 60DA





Test Report: HEP

20W Single Output Industrial DIN Rail Power Supply MODEL:MDR OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT





Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Model Number Structure

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

General-Use Auto-Tuning HPX-T Series

Plug-in/solder terminals with LED indicator

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

General-purpose Relay

General Purpose High Power PCB Relays

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

Feature. Model comment JG 3NA B L - B - D3

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

Model Number Structure

Electrical Specifications. Input range Vac (Operating) 115/230 Vac (Nominal) Internal fuse on both L and N lines.

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

Limit Switches. 6.2 E47 Precision Switches

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

Reliable high-power LED that gives you the design flexibility and performance you need

CPFE1000Fi-48 EVALUATION DATA TDK-LAMBDA

SPECIFICATION FOR LCD MODULE

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

Product Guide LED OBSTRUCTION LIGHTS

SPEDESTER Series QUICK REFERENCE GUIDE

Type CGS High-Cap Screw Terminal Aluminum Electrolytic Capacitor

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

HEATER POWER CONTROLLER

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL

AVIONICS MOUNTS Low Profile, All-Axis Vibration Isolators

Electric Smoke Damper Actuators

Dialight LED High Bay - High Output. Technical Specification Sheet - Americas

Data Sheet for Precision Potentiometer

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

Table of Contents. DS107 LUXEON Rebel PLUS Product Datasheet Lumileds Holding B.V. All rights reserved.

Transcription:

35W Single Output Switching ower Supply LV-35 series SECIFICATION MODEL LV-35-5 LV-35-12 LV-35-15 LV-35-24 LV-35-36 OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED OWER RILE & NOISE (max.) Note.2 80mVp-p VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETU, RISE TIME HOLD U TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT(max.) LEAKAGE CURRENT OVER CURRENT OVER VOLTAGE WORKING TEM. WORKING HUMIDITY SAFETY STANDARDS EMS IMMUNITY MTBF Note.6 Note.4 STORAGE TEM., HUMIDITY TEM. COEFFICIENT VIBRATION WITHSTAND VOLTAGE ISOLATION RESISTANCE 5V 12V 15V 24V 36V 5A 3A 2.4A 1.5A 1A 0 ~ 6A (Note.7) 0 ~ 3A 0 ~ 2.4A 0 ~ 1.5A 0 ~ 1A 30W 36W 36W 36W 36W 6.0% 1.0% 4.0% 120mVp-p 5.0% 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load 50ms/230VAC 90 ~ 264VAC 127 ~ 370VDC 47 ~ 63Hz 2.0% 77% 84% 1.1A/115VAC 0.7A/230VAC COLD START 30A/115VAC 0.25mA / 240VAC 110 ~ 150% rated output power 60A/230VAC 120mVp-p 150mVp-p 150mVp-p 84% 85% 85% rotection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 41.4 ~ 48.6V rotection type : Shut down o/p voltage, re-power on to recover -30 ~ +75 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +80, 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 16ms/115VAC at full load 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1310 Class 2, CAN/CSA C22.2 No. 223-M91, I67 approved ; design refer to TUV EN60950-1, EN61347-2-13 I/-O/:3KVAC I/-O/:>100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2 Class A, EN61000-3-3 / 70% RH Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 74Khrs min. MIL-HDBK-217F (25 ) LS I67 DIMENSION 148*40*30mm (L*W*H) ACKING 0.34Kg; 40pcs/14.6Kg/0.63CUFT File Name:LV-35-SEC 2010-05-25

35W Single Output Switching ower Supply LV- 35 series Mechanical Specification Case No.975A Unit:mm 600 148 600 AC/N(Blue) AC/L(Brown) 18AWG 3.6 40 3.6 16AWG +V(Red) -V(Black) 30 Block Diagram fosc : 65KHz I/ EMI FILTER & RECTIFIERS OWER SWITCHING RECTIFIERS & FILTER +V -V O.L.. WM CONTROL DETECTION CIRCUIT O.V.. Derating Curve Static Characteristics Ta=25 100 80 Others 100 90 80 60 5V 70 LOAD (%) 40 20 LOAD (%) 60 50 40-30 0 15 30 40 50 60 70 75 80 (HORIZONTAL) 90 100 125 135 145 155 165 175 180 200 230 264 AMBIENT TEMERATURE ( ) INUT VOLTAGE (V) 60Hz File Name:LV-35-SEC 2010-05-25

35W Single Output Switching ower Supply LV-35 series MODEL:LV-35-36 OUTUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1:150 mvp-p (Max ) I/: 230VAC O/:FULL LOAD V1: 53 mvp-p (Max ) 2 OUTUT VOLTAGE TOLERANCE V1:5 %~ -5 % (Max) I/: 100VAC / 264 VAC O/:FULL/ MIN LOAD V1: 0.09 %~ -0.09 % 3 LINE REGULATION V1: 1 %~ -1 % (Max) I/: 100 VAC ~ 264 VAC O/:FULL LOAD V1: 0.03 %~ -0.03 % 4 LOAD REGULATION V1: 2%~ -2% (Max) I/: 230 VAC O/:FULL ~MIN LOAD V1: 0.09 %~ -0.09 % 5 SET U TIME 230VAC: 500 ms (Max) I/: 230 VAC 230VAC/ 155 ms 115 VAC: 500 ms (Max) I/: 115 VAC 115VAC/ 117 ms O/:FULL LOAD 6 RISE TIME 230VAC: 20 ms (Max) I/: 230 VAC 230VAC/ 11 ms 115VAC: 20 ms (Max) I/: 115 VAC 115VAC/ 10 ms O/:FULL LOAD 7 HOLD U TIME 230VAC: 50 ms (TY) I/: 230 VAC 230VAC/ 123 ms 115VAC: 16 ms (TY) I/: 115 VAC 115VAC/ 27 ms O/:FULL LOAD 8 OVER/UNDERSHOOT TEST < +5% I/: 230 VAC O/:FULL LOAD 9 DYNAMIC LOAD V1: 3600 mvp-p I/: 230 VAC O/:FULL /Min LOAD 90%DUTY/1KHZ TEST: <5 % 196 mvp-p Model: LV-35-36 Test Report 1 / 5

35W Single Output Switching ower Supply LV-35 series INUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 INUT VOLTAGE RANGE 90VAC~264 VAC I/:TESTING O/:FULL LOAD I/: LOW-LINE-3V= 87 V HIGH-LINE+15%=300 V O/:FULL/MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF ) TEST: OK 57 V~264V 2 INUT FREQUENCY RANGE 47HZ ~63 HZ OSC I/: 100VAC ~ 264 VAC O/:FULL~MIN LOAD 3 EFFICIENCY 85% (TY) I/: 230 VAC O/:FULL LOAD 4 INUT CURRENT 230V/ 0.7 A (TY) I/: 230 VAC TEST: OK 85.9 % I = 0.36 A/ 230 VAC 115V/ 1.1 A (TY) I/: 115 VAC I = 0.62 A/ 115 VAC O/:FULL LOAD 5 INRUSH CURRENT 230V/ 60 A (TY) I/: 230 VAC I = 51 A/ 230 VAC 115V/ 30 A(TY) I/: 115 VAC I = 26 A/ 115 VAC COLD START O/:FULL LOAD 6 LEAKAGE CURRENT < 0.25 ma / 240 VAC I/: 264 VAC O/:Min LOAD L-FG: 0.01 ma N-FG 0.01 ma : ROTECTION FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 OVER LOAD ROTECTION 110%~ 150 % I/: 230 VAC I/: 115 VAC O/:TESTING Hiccup Mode 137 %/ 230 VAC 132 %/ 115 VAC 2 OVER VOLTAGE ROTECTION CH1: 41.4V~48.6V I/: 230 VAC I/: 115 VAC O/:MIN LOAD 45 V/ 230 VAC 41 V/ 115 VAC Shut down Re- power ON 3 SHORT ROTECTION SHORT EVERY OUTUT 1 HOUR I/: 264 VAC O/:FULL LOAD Hiccup Mode Model: LV-35-36 Test Report 2 / 5

35W Single Output Switching ower Supply LV-35 series ENVIRONMENT TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 TEMERATURE RISE TEST MODEL: LV-35-24 1. ROOM AMBIENT BURN-IN:2.5 HRS I/: 230VAC O/: FULL LOAD Ta= 28.4 2. HIGH AMBIENT BURN-IN:3 HRS I/: 230VAC O/: FULL LOAD Ta= 67.2 NO osition /N ROOM AMBIENT Ta=28.4 HIGH AMBIENT Ta= 67.2 1 LF1 LF-158 48.4 83.3 2 BD1 2A/800V KB208G 57.2 92.7 3 C5 100u/400V 105 KMG 60.3 96.1 4 D1 EG20J 2A/600V 78.3 114.9 5 T1 TF-1793 71.6 107.3 6 U1 NC1230D65R2G 59.6 95.1 7 Q1 STF6NM60N :600 V/ 4.6A 86.1 105 8 C40 47u/50V UL10Kh YXM 69.2 106.0 9 D40 1A/100V 1N4002 74.8 112.6 10 D100 FMX-12SL 10A/200V 78.6 113.2 11 C105 330u/35V L7Kh 10*16 YXG 65.8 100.3 12 L100 RB010E-R2 67.4 101.8 13 LF100 TR574 54.2 88.9 14 CASE UCASE 53.6 90 2 OVER LOAD BURN-IN TEST 1 HOUR ( MIN ) 3 LOW TEMERATURE TURN ON AFTER 2 HOUR TURN ON TEST I/: 230 VAC O/:125 % LOAD Ta:32.9 I/: 230 VAC O/: 100 % LOAD Ta= -35 4 HIGH HUMIDITY HIGH TEMERATURE HIGH VOLTAGE TURN ON TEST 5 TEMERATURE COEFFICIENT AFTER 12 HOURS IN CHAMBER ON CONTROL 65 I/: 272 VAC O/:FULL LOAD Ta= 65 HUMIDITY= 95 %R.H + 0.03 %(0~50 ) I/: 230 VAC O/:FULL LOAD 6 VIBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) + 0.005 %(0~50 ) Model: LV-35-36 Test Report 3 / 5

35W Single Output Switching ower Supply LV-35 series SAFETY TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 WITHSTAND VOLTAGE I/-O/: 3 KVAC/min I/-O/: 3.6 KVAC/min I/-O/: 1.912 ma 2 ISOLATION RESISTANCE I/-O/:500VDC>100MΩ I/-O/: 500 VDC I/-O/: 22.1 GΩ /70%RH 3 AROVAL TUV: Certificate NO : UL: File NO : N E.M.C TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 HARMONIC EN61000-3-2 CLASS A I/: 230/240/220 VAC/50HZ O/:100/75/50/25% LOAD ASS 2 CONDUCTION EN55022 I/: 230 VAC (50HZ)/115V(60HZ) ASS CLASS B O/:FULL/50% LOAD Test by certified Lab 3 RADIATION EN55022 I/: 230 VAC (50HZ) /115(60HZ) ASS CLASS B O/:FULL LOAD Test by certified Lab 4 E.S.D EN61000-4-2 I/: 230 VAC/50HZ CRITERIA A LIGHT INDUSTRY AIR:8KV / Contact:4KV O/:FULL LOAD 5 E.F.T EN61000-4-4 I/: 230 VAC/50HZ CRITERIA A LIGHT INDUSTRY INUT: 1KV O/:FULL LOAD 6 SURGE IEC61000-4-5 I/: 230 VAC/50HZ CRITERIA A LIGHT INDUSTRY L-N :1KV O/:FULL LOAD L,N-E:2KV 7 Test by certified Lab & Test Report repare M.T.B.F & LIFE CYCLE CALCULATION NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 CAACITOR LV-35-24:SUOSE C105 IS THE MOST CRITICAL COMONENT LIFE CYCLE I/: 230VAC O/:FULL LOAD Ta=25 LIFE TIME=158798 HRS I/: 230VAC O/:FULL LOAD Ta=65 LIFE TIME=13343 HRS I/: 230VAC O/:75% LOAD Ta=65 LIFE TIME=19559 HRS 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 74 KHRS 3 ORT (Ongoing Reliability test) LV-35-24:I/:230VAC O/:FULL LOAD TA=50 Sample=10pcs TEST TIME=3504HRS Model: LV-35-36 Test Report 4 / 5

35W Single Output Switching ower Supply LV-35 series COMONENT STRESS TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 ower Transistor ( D to S) or (C to E) eak Voltage 2 Diode eak Voltage D100Rated Q1 Rated STF6NM60N :600 V/ 4.6A SF10LC40 10A/400V 3 Clamp Diode eak Voltage D1 Rated EG20J:2A/600V I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2) Output Short I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2)Output Short I/:High-Line +3V = 267 V O/: (1) Dynamic Load 90%Duty/1KHz (1) 576 V (2) 584 V (1) 344 V (2) 346 V (1) 518 V 4 Input Capacitor Voltage C5 Rated 120u/400V 105 KMG I/:High-Line +3V = 267 V O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 369 V (2) 374 V (3) 374 V 5 Control IC Voltage Test U1 NC1230/ 18V I/:High-Line +3V = 267 V O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 12.34 V (2) 10.29 V (3) 12.34 V DATE SAMLE TEST RESULT TESTER AROVAL 2008/5/5 RD SAMLE ASS SANFORD SU VINCENT TSENG 2008/9/4 2008/9/16 RODUCT SAMLE W0806C09 RODUCT SAMLE W0808D12 ASS SANFORD SU VINCENT TSENG ASS SANFORD SU VINCENT TSENG 2003/12/12 A50-F023 Model: LV-35-36 Test Report 5 / 5