60W Single Output Switching ower Supply LC-60 series SECIFICATION MODEL LC-60-1050 LC-60-1400 LC-60-1750 OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC OTHERS NOTE DC VOLTAGE RANGE RATED OWER LINE REGULATION LOAD REGULATION SETU, RISE TIME HOLD U TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT(max.) LEAKAGE CURRENT CURRENT LIMIT OVER VOLTAGE WORKING TEM. WORKING HUMIDITY SAFETY STANDARDS EMS IMMUNITY MTBF Note.6 Note.4 STORAGE TEM., HUMIDITY TEM. COEFFICIENT VIBRATION 9 ~ 48V 9 ~ 42V 9 ~ 34V 50.4W 58.8W 59.5W RILE & NOISE (max.) Note.2 200mVp-p 200mVp-p 200mVp-p VOLTAGE TOLERANCE Note.3 WITHSTAND VOLTAGE ISOLATION RESISTANCE 5.0% 1.0% 2.0% 500, 120 / 230VAC 500, 120 / 115VAC at full load 50/230VAC 90 ~ 264VAC 127 ~ 370VDC 47 ~ 63Hz 87% 1.2A/115VAC 0.7A/230VAC COLD START 30A/115VAC 0.25mA / 240VAC 60A/230VAC 85% 5% rated output current rotection type : Constant current limiting type 50.4 ~ 60V 44.1 ~ 56.7V rotection type : Shut off o/p voltage, clamping by TVS diode -30 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +80, 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 16/115VAC at full load 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes EMI CONDUCTION & RADIATION Compliance to EN55022 (CISR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2 Class A, EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 732Khrs min. MIL-HDBK-217F (25 ) 39.1 ~ 45.9V UL1310 Class 2, CAN/CSA C22.2 No. 223-M91(for LC-60-1750 only), I67 approved ; design refer to TUV EN60950-1, EN61347-2-13 I/-O/:3KVAC I/-O/:>100M Oh / 500VDC / 25 / 70% RH LS I67 RATED CURRENT 1050mA 1400mA 1750mA DIMENSION 162.5*42.5*32mm (L*W*H) ACKING 0.4Kg; 32pcs/13.8Kg/0.56CUFT 87% File Name:LC-60-SEC 2010-05-25
60W Single Output Switching ower Supply LC-60 series Mechanical Specification Case No. 976A Unit:mm 600 162.5 600 AC/N(Blue) AC/L(Brown) 18AWG 3.6 42.5 3.6 16AWG +V(Red) -V(Black) 32 Block Diagram fosc : 60KHz I/ EMI FILTER & RECTIFIERS OWER SWITCHING RECTIFIERS & FILTER +V -V O.C.. O.L.. WM CONTROL DETECTION CIRCUIT Derating Curve Static Characteristics Ta=25 100 100 90 80 80 60 70 LOAD (%) 40 20 LOAD (%) 60 50 40-30 -15 0 15 30 40 50 60 70 (HORIZONTAL) 90 100 125 135 145 155 165 175 180 200 230 264 AMBIENT TEMERATURE ( ) INUT VOLTAGE (V) 60Hz File Name:LC-60-SEC 2010-05-25
60W Single Output Switching ower Supply LC-60 series MODEL:LC-60-1400 OUTUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 200 mvp-p (Max ) I/: 230VAC O/:FULL LOAD V1: 96 mvp-p (Max ) 2 OUTUT VOLTAGE CH1: 9 V~ 42 V I/: 230 VAC 0 V~ 41.90 V/ 230 VAC RANGE I/: 115 VAC O/:MIN LOAD 0 V~ 41.90 V/ 115 VAC 3 OUTUT VOLTAGE V1: 5 %~ -5 % (Max) I/: 100 VAC / 264 VAC V1: 0.06 %~ -0.06 % TOLERANCE O/:FULL/ MIN LOAD 4 LINE REGULATION V1: 1 %~ -1 % (Max) I/: 100VAC ~ 264 VAC O/:FULL LOAD V1: 0.02 %~ -0.02 % 5 LOAD REGULATION V1: 2 %~ 2 % (Max) I/: 230 VAC O/:FULL ~MIN LOAD V1: 0.06 %~ -0.06 % 6 SET U TIME 230VAC: 115 VAC: 500 500 (Max) (Max) I/: 230 VAC I/: 115 VAC O/:FULL LOAD 230VAC/ 115VAC/ 170 103 7 RISE TIME 230VAC: 120 (Max) I/: 230 VAC 230VAC/ 46 115VAC: 120 (Max) I/: 115 VAC 115VAC/ 23 O/:FULL LOAD 8 HOLD U TIME 230VAC: 115VAC: 50 16 (TY) (TY) I/: 230 VAC I/: 115 VAC O/:FULL LOAD 230VAC/ 115VAC/ 103 23 9 OVER/UNDERSHOOT TEST < +5% I/: 230 VAC TEST: <5 % O/:FULL LOAD 10 DYNAMIC LOAD V1: 4200 mvp-p I/: 230 VAC O/:FULL /Min LOAD 90%DUTY/1KHZ 373 mvp-p Model: LC-60-1400 Test Report 1 / 5
60W Single Output Switching ower Supply LC-60 series INUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 INUT VOLTAGE RANGE 90VAC~264 VAC I/:TESTING O/:FULL LOAD I/: LOW-LINE-3V= 87 V HIGH-LINE+15%=300 V O/:FULL/MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF ) TEST: OK 49V~264V 2 INUT FREQUENCY RANGE 47HZ ~63 HZ OSC I/: 100 VAC ~ 264 VAC O/:FULL~MIN LOAD 3 EFFICIENCY 85% (TY) I/: 230 VAC O/:FULL LOAD 4 INUT CURRENT 230V/ 0.7 A (TY) I/: 230 VAC TEST: OK 88.7% I = 0.5 A/ 230 VAC 115V/ 1.2 A (TY) I/: 115 VAC I = 0.9 A/ 115 VAC O/:FULL LOAD 5 INRUSH CURRENT 230V/ 60 A (TY) I/: 230 VAC I = 51 A/ 230 VAC 115V/ 30 A(TY) I/: 115 VAC I = 26 A/ 115 VAC COLD START O/:FULL LOAD 6 LEAKAGE CURRENT < 0.25 ma / 240 VAC I/: 240 VAC O/:Min LOAD L-FG: 0.01 ma N-FG: 0.01 ma ROTECTION FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 OVER LOAD ROTECTION 95 %~ 105 % I/: 230 VAC I/: 115 VAC O/:TESTING 102.7%/ 230 VAC 102.8%/ 115 VAC Constant Current Limiting 2 OVER VOLTAGE ROTECTION CH1: 44.1 V~ 56.7 V I/: 230 VAC I/: 115 VAC O/:MIN LOAD 51.4V/ 230 VAC 51.4V/ 115 VAC Shut down Re- power ON 3 SHORT ROTECTION SHORT EVERY OUTUT 1 HOUR I/: 264 VAC O/:FULL LOAD Constant Current Limiting Model: LC-60-1400 Test Report 2 / 5
60W Single Output Switching ower Supply LC-60 series ENVIRONMENT TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 TEMERATURE RISE TEST MODEL: LC-60-1750 1. ROOM AMBIENT BURN-IN:2 HRS I/: 230VAC O/: FULL LOAD Ta= 30.9 2. HIGH AMBIENT BURN-IN:8 HRS I/: 230VAC O/: FULL LOAD Ta= 63.2 NO osition /N ROOM AMBIENT Ta= 30.9 HIGH AMBIENT Ta= 63.2 1 U1 NC1230D65R2G 74.2 96.3 2 BD1 D3SB60 4A/600V 72.7 94.4 3 LF1 LF158 66.0 87.6 4 C5 120u/400V 105 KMG 78.8 100.0 5 Q1 STF6NM60N :600 V/ 4.6A 86.3 107.8 6 D1 EG20J 2A/600V 84.8 105.1 7 ZD1 6KE180A 80.4 98.7 8 D40 1A/100V 1N4002 80.7 102.6 9 C40 47u/50V UL10Kh YXM 81.8 103.3 10 T1 TF1780 81.5 105.7 11 D100 SF10LC40 10A/400V 83.2 104.1 12 C105 220u/50V L7Kh YXG 76.6 97.6 13 L100 RB010E 70.5 92.0 14 CASE UCASE 59 87.9 2 OVER LOAD BURN-IN TEST 1 HOUR ( MIN ) 3 LOW TEMERATURE TURN ON AFTER 2 HOUR TURN ON TEST I/: 230 VAC O/:101 % LOAD Ta:32.7 I/: 264 VAC O/:100 % LOAD Ta= -35 4 HIGH HUMIDITY HIGH TEMERATURE HIGH VOLTAGE TURN ON TEST 5 TEMERATURE COEFFICIENT AFTER 12 HOURS IN CHAMBER ON CONTROL 50 I/: 272 VAC O/:FULL LOAD Ta= 50 HUMIDITY= 95 %R.H + 0.03 %(0~50 ) I/: 230 VAC O/:FULL LOAD 6 VIBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) + 0.004 %(0~50 ) Model: LC-60-1400 Test Report 3 / 5
60W Single Output Switching ower Supply LC-60 series SAFETY TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 WITHSTAND VOLTAGE I/-O/: 3 KVAC/min I/-O/: 3.6 KVAC/min I/-O/: 2.632 ma 2 ISOLATION RESISTANCE I/-O/:500VDC>100MΩ I/-O/: 500 VDC I/-O/: 30 GΩ /70%RH 3 AROVAL TUV: Certificate NO : UL: File NO : N/A E.M.C TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 HARMONIC EN61000-3-2 CLASS A 2 CONDUCTION EN55022 CLASS B I/: 230/240/220 VAC/50HZ O/:100/75/50/25% LOAD I/: 230 VAC (50HZ) O/:FULL/50% LOAD 3 RADIATION EN55022 CLASS B I/: 230 VAC (50HZ) O/:FULL LOAD 4 E.S.D EN61000-4-2 LIGHT INDUSTRY AIR:8KV / Contact:4KV I/: 230 VAC/50HZ O/:FULL LOAD ASS ASS Test by certified Lab ASS Test by certified Lab CRITERIA A 5 E.F.T EN61000-4-4 LIGHT INDUSTRY INUT: 1KV I/: 230 VAC/50HZ O/:FULL LOAD CRITERIA A 6 SURGE IEC61000-4-5 LIGHT INDUSTRY L-N :1KV L,N-E:2KV I/: 230 VAC/50HZ O/:FULL LOAD CRITERIA A 7 Test by certified Lab & Test Report repare M.T.B.F & LIFE CYCLE CALCULATION NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 CAACITOR LC-60-1750:SUOSE C105 IS THE MOST CRITICAL COMONENT LIFE CYCLE I/: 230VAC O/:FULL LOAD Ta=25 LIFE TIME=86553 HRS I/: 230VAC O/:FULL LOAD Ta=50 LIFE TIME=33481 HRS 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 732K HRS 3 ORT (Ongoing Reliability test) LC-60-1400:I/:230VAC O/:95% LOAD TA=50 Sample=10pcs TEST TIME=2856HRS Model: LC-60-1400 Test Report 4 / 5
60W Single Output Switching ower Supply LC-60 series COMONENT STRESS TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 ower Transistor ( D to S) or (C to E) eak Voltage 2 Diode eak Voltage D100Rated Q1 Rated STF6NM60N :600 V/4.6A SF10LC40 10A/400V 3 Clamp Diode eak Voltage D1 Rated EG20J:2A/600V I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2) Output Short I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2)Output Short I/:High-Line +3V = 267 V O/: (1) Dynamic Load 90%Duty/1KHz (1) 580 V (2) 538 V (1) 362 V (2) 364 V (1) 516 V 4 Input Capacitor Voltage C5 Rated 120u/400V 105 VZ I/:High-Line +3V = 267 V O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 376 V (2) 380 V (3) 380 V 5 Control IC Voltage Test U1 NC1200/ 18V I/:High-Line +3V = 267 V O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 12.11 V (2) 10.14 V (3) 12.11 V DATE SAMLE TEST RESULT TESTER AROVAL 2008/4/9 RD SAMLE ASS SANFORD SU VINCENT TSENG 2008/9/4 2008/11/10 RODUCT SAMLE W0806B59 RODUCT SAMLE W0809E06 ASS SANFORD SU VINCENT TSENG ASS SANFORD SU VINCENT TSENG 2003/12/12 A50-F023 Model: LC-60-1400 Test Report 5 / 5