SOLID FUEL STOVE ELITA and ELITA II

Similar documents
17500 VRANJE, SRBIJA Radnička 1, Tel.: 017/ INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT AND USE

APPENDIX TO THE INSTALLATION AND OPERATING MANUAL OF STOVEMAN SAUNA STOVE

USAGE AND MAINTENANCE MANUAL FOR A SOLID FUEL STOVE

HARVIA IRON STOVE Instructions for installation and use

Mod. MONTANA WOOD BURNING STOVE USAGE AND MAINTENANCE INSTRUCTIONS

MULTI-FUEL STOVE INSTALLATION AND USER INSTRUCTIONS

O P E R A T I O N AND INST A L L A T I O N M A N U A L

OPERATION AND INSTALLATION MANUAL OPUS TRIO FIRED BY DESIGN

Saltfire ST4 INSTALLATION AND OPERATING INSTRUCTIONS.

Installation Instructions

General Information. Construction of the stove. Top or rear outlet of gases

Saltfire ST1 INSTALLATION AND OPERATING INSTRUCTIONS.

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

How to use a multi fuel stove

Installation Instructions

Installation and Operating. Instructions. Multifuel Stove. Salamander. Model Lighting a solid fuel fire. 6.5 De-ashing the stove

Installation Instructions

User s manual. An der Bundesstraße Haren/Ems Germany Tel. +49(0) LUNA III H

Installation Instructions

Installation and Operating Instructions

Installation Instructions

EB300. Ethanol Burner. User s Manual Installation Instructions

User s manual. Titan. Ch. Leibfried GmbH An der Bundesstraße Haren/Ems Germany Tel: +49(0)

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

Installation and Operating Instructions

Asgård 7F User Manual Ecolabel - Sintef EN

Installation Instructions

PS Model INSTALLATION AND OPERATION MANUAL FOR WOOD-BURNING SAUNA STOVES

Installation Instructions

Harrie Leenders Fuga el - Instructions for Installation, Use and Maintenance INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

Lit Table Top Firepit Bio-Ethanol Fireplace. User Manual. Model: GF301650

INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE YSEN

Dear Viking-customer,

Alma Mons EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION

Intrepid 2 Intrepid 3

Installation instruction

Bloomsbury SE SMOKE EXEMPT WOODBURNING STOVE INSTALLATION & USER INSTRUCTIONS (TO BE LEFT WITH THE CUSTOMER) UK & IRELAND GUARANTEE

Aduro 10. User Manual. Ecolabel - Sintef EN Version 2

Aduro 6 / Aduro 6-5 / Aduro 6SK

User s manual. Eros I. An der Bundesstraße Haren/Ems Germany Tel. +49(0)

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

Installation Instructions

Asgård 3 / Asgård 4 / Asgård 6

Reference: Ottawa 12kw Operating Instructions Version 1 04/06/15. Installation and Operating Instructions

ASSEMBLY- AND INSTRUCTIONS FOR USE. Scan Congratulations on your new Scan wood-burning stove

Installation Instructions

Installation instruction

FUGA el MkII MANUAL EN

Read all instructions and warnings before using this fireplace. WARNING

DIANA EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION. Available in ceramic and metalsheet version.

OPERATION AND INSTALLATION MANUA L OPUS TEMPO

T e l: Operating Instructions for the Dean Forge Hembury 6 & 8

Installation instruction

Installation instruction

Installation instruction

Mounting and User Instructions. Lotus-Living-Series Stoves. Version 1,

Solid fuel stove GULIVER

Installation instructions

Varde Lyon Varde Nice

Glás Non Boiler Insert

Before using your stove for the first time, we would like to give you useful instructions and security advice for the correct use of our product.

OLYMBERYL Multi-Fuel Stove

ECO-FRIENDLY WOODBURNING STOVES

Please contact the olymberyl dealer in your area if you have any questions about your stove that are not covered in this manual.

Installation instruction

User Manual. 110 Cup (55 Cup Raw) Rice Cooker. Model: 177GRCLP, 177GRCNAT 10/2017. Please read and keep these instructions. Indoor use only.

instruction manual & security advices for decoration fire places of BFT (habee-feuer) /

SMART BIO-ETHANOL ELECTRONIC BURNER

Mounting and User Instructions. Lotus-Liva. Lotus Liva 5, Liva 5G, Liva 6, Liva 6G, Liva 7G, Liva 8G. Version 2 02/

ASSEMBLY- AND INSTRUCTIONS FOR USE. Congratulations on your new Scan wood-burning stove

Installation instructions

EKOL CRYSTAL-8 INSTALLATION AND OPERATING INSTRUCTIONS

Instructions for use, installation, and connection. Gas Built in Hob

Chimney Stove. Nominal heating capacity Power range Efficiency. Swirl combustion chamber. schneeweiss schneeweiss weichsel Sonderglasur Serpentin

CONTENTS. INSTALLATION INSTRUCTIONS Building regulations 4 Positioning and Clearances 4 Chimney 4 Flue connection 5 Problem solving 6 PRODUCT DATA

Installation & User Manual EW5000 Outdoor Cooking Fire

ECO-FRIENDLY WOOD-BURNING STOVES OF DANISH DESIGN

Dean Forge Fabrication Ltd. Dean Prior, Buckfastleigh, Devon TQ11 0LS. T e l:

User and mounting manual. Stove models: TT10 + TT10S + TT10H + TT10HS + TT10G

125SE SMOKE EXEMPT WOODBURNING STOVE INSTALLATION & USER INSTRUCTIONS (TO BE LEFT WITH THE CUSTOMER) UK & Ireland GB IE GUARANTEE

FREESTANDING OWNER'S MANUAL WOOD STOVES

Mounting and User Instructions Lotus M Series Stoves

BRANSDALE DOUBLE SIDED WOOD BURNING STOVE

BLOOMSBURY SE INSTALLATION & USER INSTRUCTIONS. Smoke Exempt Multi-Fuel Stove (TO BE LEFT WITH THE CUSTOMER) UK & IRELAND

SIMPLY SOME OF THE FINEST STOVES AVAILABLE

SINGLE BURNER STOVE IMPORTANT OPERATING INSTRUCTIONS COOKING & STORAGE POSITION PARTS IDENTIFICATION

This booklet applies to following Westfire stoves WF UNIQ 4 / WF4 WF UNIQ 18 /WF 18 WF UNIQ 16 /WF16 WF UNIQ 23 /WF 23 WF UNIQ 32 /WF32

Inspecting your combustor

Installation Instructions. Woolly Mammoth Stoves Albert Road, Braintree, Essex, CM7 3JQ

Mounting and User Instructions. Lotus-Prestige Series Stoves. (Lotus Prestige, Prestige S) Version 2, 23/

Inserts. Model 100, 200. Installation instructions Care and firing instructions

T e l: Operating Instructions for the Dean Forge Clearburn Range (Excluding Junior and Junior SE)

Installation and Operating Instructions. Ottawa 12kw

WIKING Mini 2. Installation and User Instructions /

ECO-FRIENDLY WOOD-BURNING STOVES

1 GENERAL 2 TECHNICAL SPECIFICATION 3 DESIGN MODEL 4 OPERATION SAFETY

INSTALLATION AND USER INSTRUCTIONS

The wall where the product will be placed must not be constructed in wood, or in any case, made of an

Saltfire ST3 INSTALLATION AND OPERATING INSTRUCTIONS.

Transcription:

17500 VRANJE, SERBIA Radnicka 1, tel.: 017 421 121 SOLID FUEL STOVE ELITA and ELITA II INSTRUCTIONS FOR INSTALLATION AND USE

GENERAL DATA Generally it is necessary to adhere to the construction rules and regulations about fireboxes applicable in the country, as well as all necessary local, national and European standards. Important before use: - So that your stovecould function properly, it is important that you carefully read this manual and strictly adhere to the listed instructions herein. - Use only a recommended fuel type that is, wood logs and brown coal briquettes. - The requireddischarge pressure during normal operating load should be ca. 12 Pa. At discharge pressure over 15 Pa a built-in vent damper should be used in the outlet pipe. - In the room where the stove is being placed, it is necessary to ensure that there is enough intake of fresh air in the firebox. If the windows and door are hermetically sealed or if other devices such as steam extractor, clothes dryer, fans etc. draw away the air in the room where the stove is placed, then, if needed, the combustion air (fresh air) must be brought from outside. In this regard, in any case before installing the stove, consult with a competent organization for flues. - No type of flammable materials should be kept in the ash box. The height of filling must not exceed the height of the lateral sides of the ash box. - The door of the stove and the space for ash must always be kept closed (except during ignition, inserting fuel and cleaning ash), in order to prevent release of hot air. - The stove must not be changed, except with our offered, checked original parts of accessories and if work is performed by ourfactory repair service. - In case of fire in the flue, the door of the stove must be kept closed, and close the air regulator! Never attempt to extinguish fire in the flue by pouring water. Due to the water vapor which is then created in the flue, an explosion in the flue might occur. If necessary call the fire department on emergency their number! - If there are faults, close all air regulators and do not insert new fuel in the stove until the cause for the fault is eliminated!

Fig. 1 Solid fuel stove 1. Flue connection 2. Stove panel 3. Secondary air intake 4. Stove door 5. Grate shaker 6. Primary air regulator 1. Technical data - width......455 mm - depth......422 mm - height.865 mm - rated heating power.6,0 kw - diameter of flue pipe connection....ø120 mm - draft 12 Pa - stove weight 67 kg - flue engagement upwards - mass flow of flue gases - wood logs... 3,5 g/s - browncoal briquettes.. 4,1 g/s - waste gases temperature - wood logs... 260 C - browncoal briquettes.. 225 C - requireddischarge pressure - wood logs.... 12 Pa - browncoal briquettes... 12 Pa - content CO2 - wood logs...... 9,61 % - browncoal briquettes. 9,03 %

2. Stove description The stove consists of sheet-metal parts with a cast iron grate, cast iron panel and sheet-metal door. The firebox is covered with replaceable panels of fire clay. The external coating is enameled or painted. The opening for adjusting air needed for combustion is located on the stove door. 3. Air regulation Air regulation is done on the stove door. The air regulator on the stove door provides ignition and fuel combustion. Pay attention that the ash box is not overfull. Its emptying should be regular in order to provide unobstructed air intake. The secondary air intake is on the stove door. The secondary air supplies fire with the oxygen needed for clean combustion (burning of previous incomplete combustion products). Due to poor oxygen intake, a great emission of harmful substances occurs, which can lead to blockage of the flue. 3.1 Primary air Fig. 2 Reliable fuel combustion is determined on the basis of primary air for combustion. This air is adjusted by regulating the primary air on the stove door in the ashtray part (figure 2, position 7). The air regulation on the stove door in the part of the space for ash (figure 2, position 7) indicates the direction of closing and opening ofregulator. For wood ignition, the regulator should be maximally open. WARNING: To avoid stove overheating, fuel quantity must not exceed 2,0 kg of dry wood logs or coal briquettes per hour, when the combustion air is properly adjusted. 3.2 Use of knobs on firebox door As the knobs on the firebox door become very hot during stove combustion, closing and opening of the firebox door is possible only with a special wrench from the enclosed stove accessories (see figure 3).

4. Stove installation When installing the stove adhere to the applicable regulations regarding construction and fire preventive requirements. The placement site should be horizontal and must have sufficient bearing capacity,otherwise appropriate measures must be implemented for even load distribution. In case of flammable floor (wood, plastic, textile ) it is necessary to put steel sheet, copper or other inflammable material under the stove. This pad must pass at least 30 cm from the stove profile and on the side of the knobthat pad should be bigger than 50 cm distance from the stove. The distance between wooden parts of furniture or plastic and other flammable objects that need to be protected must be at least 30 cm on the sides and 30 cm on the back of the stove. Inflammable objects must have a distance of at least 80 cm from the opening for filling the stove. There should be enough distance between the stove and flammable objects (with timber paneling, furniture, curtains etc.) Embedding objects above the stove is not allowed when a stove with cast iron plate is used. When installing the used air outlet pipe, the distance from flammable materials should be at least 40 cm. Before connecting the stove to the flue, a competent local flue institution should certainlybe consulted. The connection of the stove to the flue is performed through the connection elements according to SRPS.M.R4.031 (DIN 1298 or DIN EN 18562). Pay attention that connection parts for the flue do not protrude in the waste gasses outlet section and they should seal properly. In order to achieve the best stove power, the stove installation should be properly performed and flawless flue function should be provided. In any case, the existing flue pressure should be checked before stove commissioning by putting a burning candle under the flue opening. The flue draft is sufficient if the candle flame bends towards the flue opening. Slight candle flame bending indicates insufficient air draft. If two fireboxes are installed on one flue on one floor (multiple engagements), the distance between the connections should not be less than 50 cm. 5. Stove commissioning Before stoking for the first time, enameled surfaced should be wiped with a damp cloth, in order to prevent creation of stains. Do not touch painted surfaces and do not leave any objects on the stove to prevent damage of paint. The paint finally hardens even after few hours of heating. After reading Instructions for use, the first commissioning follows. When stoking for the first time, open the windows since the anticorrosion protection creates an unpleasant smell and some smoke. This is a normal occurrence and it stops after a short time. If necessary, also switch on the fan for fast air circulation. Stoke up to the maximum temperature load at least for 1 hour. If the maximum temperature is not reached during the first process of stoking, problems with unpleasant smell might occur later as well. Persons such as pregnant women and small children should be outside that room during this stoking stage. Keep in mind that some built-in stove parts (outlet pipe, door for filling, stove door) etc. become very hot during operation and there is a risk of burns. Keep small children away from the stove. When stoking the stove for the first time, small quantities of fuel should be stoked three times in order to prevent fire clay bursting.

5.1 Stove commissioning and stove operation - Maximally open the primary air regulation (figure 2, position 7) - Open the stove door - Put wood wool, wood chips or paper - Put two pieces of wood over this - Ignite - Close the stove door - Let the wood burn away. After ember is created, put new fuel through the opening for stoking and adjust the air regulator for primary air according to the fuel type. Never put new fuel on a flame! In case of sudden opening of the stove door, certain quantity of smoke is released. When adding fuel, the stove door should be slowly open, in order to remove smoke. This way smoke entering the room is avoided. Rated heating power is reached with the following fuel quantities, followed by adjusting the primary air regulator. Fuel type Fuel quantity Combustion time Air regulation on the stove door in the ashtray part Kg h Degree Wood logs 2,0 1 20 mm open Brown coal briquettes 1,7 1 30 mm open The stove may be stoked only with natural, wood logs and brown coal briquettes. Wood logs are inserted in wood pieces with a length of 32 cm and certain number of pieced is inserted in case of brown coal briquettes. Lacquered, painted, veneered and impregnated firewood or wood treated with glue is not allowed for use in the stove. In this case every guarantee and responsibility of the manufacturer ceases. The firewood that you need to use should be dry (wood humidity up to 20%). The wet wood has low calorific value and creates sediments in the drain channels as well as in the flue. In cases of the most adverse weather conditions, a fault may occur in the flue (for example bad weather conditions). In such cases, stove operation is not allowed for safety reasons. 5.2 Stove maintenance and cleaning The entire stove should be regularly controlled by an expert. The stove, smoke pipe and flue must be regularly cleaned several times a year, and at least once in the heating season. Regular maintenance and cleaning of the stove has special importance for good and reliable stove operation. Maintenance of the enameled painted surfaces is recommended only when the stove is cold. The stove is washed with clean water and soft cloth. Painted surfaces of the stove are cleaned with a dust brush or a dry cloth.

Fig. 7 Do not use water or dump cloths for painted stoves. The period between stove cleanings depends on the fuel type, that is, on the duration and the type of stove usage. The ash box (figure 7, position 11) should be regularly emptied before every stove ignition. The grate should be cleaned 1-2 times a week. In case of clogged air intakes with clayor other combustion residues, these should be immediately removed. For this purpose, the grate must be completely removed and cleaned. When stoking, creation of smokeon the glass should be avoided. During combustion, smokeis created for the following reasons: - poor draft in theflue (bad flue) - the stove is improperly used, for example, the oxygen supply is stopped too early. We donot have any influence on the previously listed facts. For this reason we cannot take over any guarantee for clean glass. Shaking of the grate is performed via the knobspresented on figure 8. Fig. 8 6. General data If you adhere to the instructions for installing and use of the stove, this stove will be a reliable source of heat. All problems with Your stove can be resolved by our service. In case of complaints regarding problems or mistakes about the functions, please contact our service. They will help You as well as for orders of spare parts. 7. TIME OF GUARANTEED SERVICING This implies the period during which we guarantee the service, accessories and space parts, starting from the day of purchase of the device. The time of guaranteed servicing is in accordance with the valid legal regulations. In case of change of the model and the design of the device, the term for change of parts that have modified design is within the legal term. After this term we provide the modified parts in the new designs. 7.1 CONDITIONS OF THE GUARANTEE The guarantee of the product is valid within the legally defined term. The guarantee is not valid for the glass, the glass-ceramic panel and the physical damages that have occurred after purchase. THE MANUFACTURER RETAINS ALL THE RIGHTS TO MAKE CHANGES.

The device will properly function within the guaranteed term only if it is used in accordance with these guidelines for connection and application. The guarantee cases to apply if it is determined that: -the connection or the repair of the product was performed by an unauthorized person, that is, if unoriginal parts have been embedded, - if the device has not been properly used in accordance with these guidelines, - if some mechanical damaging of the device occurred during usage, - if the repairs of defects were performed by an unauthorized person, - if the device has been used for commercial purposes, - if the damage has occurred during transportation after the device was sold, - if the defects occurred due to improper mounting, improper maintenance or mechanical damaging by the buyer, - if the defect occurred after too strong or insufficient power, as well due to force major. We can repair the defects of Your device also outside the guaranteed period, with original spare parts for which we also provide a guarantee under the same conditions. This guarantee does not exclude or affect the rights of the customer in regard to the conformity of the goods pursuant to the legal regulations. If the delivered product does not conform to the agreement, the customer has the right to ask the seller to repair that lack of conformity without any reimbursement, by repair or change of the product in accordance with the valid legal regulations.