1 Pelican AMR Gateway User Guide Document Reference: 8194 June 2016 Version: 2
2 Version Date Author Changes Number 1 Feb 2014 Bettina Rubek-Slater 2 Jun 2016 Sam Smith Branding updated API section updated Page 1
3 Contents 1 Introduction Pelican description Data recording and storing Pre-installation Technical specification Pelican Specification Antenna Specification Installation instructions Precautions General Precautions Disposal of the Pelican Product Uses and installation requirements Product Servicing Data Portal emig Portal Pelican APIs Example of Post Strings Messaging Breakdown Message Breakdown Illustrations Tracking with Google Earth How to view the Pelicans... 8 Page 2
4 1 Introduction Thank you for choosing an Eseye Pelican AMR Gateway! All Eseye products are M2M-grade and can include use of the AnyNet global managed connectivity. There are too many different connected applications for which this gateway can be used to include them all in this document. We regularly add user guides to the suite of guides for our products so if you need information that you do not find here please feel free to ask us for it. This guide has been written for use by technically competent persons with a good understanding of communications technologies used for AMR gateways, mobile networks and IP products, and of the requirements for their specific application. 2 Pelican description The Pelican from Eseye is a GSM enabled AMR gateway. It has been designed to be part of a meter connectivity integration project by providing pulse measurements for any standard utility meter such as for electricity, gas and water monitoring. The Eseye Pelican is designed specifically to interface with any standard utility meter and offers: GSM 900MHz / 1800MHz Any Network Embedded SIM External Antenna Options Single Channel Pulse Input Power Fail Alert Configurable Reporting Period Web Portal or API 2.1 Data recording and storing Data is stored in 30 minute intervals, a rate that was set to balance network data-transfer price and performance. It is possible to change these settings but it should be noted that if the data is sent more often, there will be a slight increase in the data charges. 3 Pre-installation Prior to installation, the equipment should be registered. For registration instructions please contact Eseye support on support@eseye.com or telephone +44 (0) Page 3
5 4 Technical specification The pelican is designed to interface to a certified meter with a pulse output. E.g. ABB s OD1365. All meter manufacturers have pulse output meters so there is no restriction. NOTE The Eseye Shoebill Utility Monitor is similar, but uses a current clamp to measure the electricity usage. However it is not as accurate as a meter (+-5%) so cannot be used for billing purposes. The Shoebill device can measure 2 separate circuits. 4.1 Pelican Specification Characteristics Voltage Maximum current Normal current consumption GSM Ambient Operating Temperature Minimum Maximum Specification 5 Volts 300 ma 30 ma 900MHz / 1800MHz 5 0 C 40 0 C 4.2 Antenna Specification ES QUAD ES DUAL Frequency range Gain MHz GSM850 band MHz GSM900 band MHz DCS1800 band MHz PCS1900 band GSM900 and DCS1800 GSM850 and PCS MHz GSM900 band MHz MHz DCS1800 band GSM900 and DCS1800 Impedance 50 Ohm 50 Ohm Input power > 2 W > 2 W VSWR 2:1 2:1 Please see more information in 8343 Pelican Specification Sheet. Page 4
6 5 Installation instructions The Eseye Pelican is designed to be DIN rail mounted. To mount the Pelican on a DIN rail 1. Line up the top of the equipment (the antenna side) against the DIN rail, 2. Push the bottom towards the rail until it locks into place. To remove the Pelican from the DIN rail mounting a screwdriver can be used to lever the white locking mechanism on the bottom underside of the Pelican. The power supply should be rated at 5 Volts DC, with a minimum current rating of 300 ma (1.5 Watt). Supply wiring should be suitably rated for the power requirements of the equipment. Once installed and powered on the ONLINE LED indicator will begin to flash, while the equipment has successfully established a GSM connection the indicator will go solid. ONLINE PULSE Antenna The safety of any system incorporating the equipment is the responsibility of the assembler of the system. An example of a Pelican in situ 5 Volts Ground Pulse 6 Precautions 6.1 General Precautions While in use, at least 20cm distance should be kept between the antenna and the human body. A drop or heavy impact may cause damage to the Pelican. If the Product experiences a drop or heavy impact safely dispose of it immediately, even if the equipment does not appear damaged. 6.2 Disposal of the Pelican Correct disposal of this product. The Pelican should not be disposed of with other household waste at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate the product from other types of waste and recycle it responsibly to promote the sustainable reuse of material resources. Users should contact either the supplier where they purchased this product, or their local government office, for details of where and how they can take these items for environmentally safe recycling. This product should not be mixed with other commercial wastes for disposal. This equipment is compliant with RoHS. Page 5
7 6.3 Product Uses and installation requirements The Eseye Pelican is designed for indoor use only. The product should not be exposed to any water, or other liquid. Use within an environment that exposes the product to any liquid is not recommended. Housing of the product within a suitably rated protective enclosure is recommended. 6.4 Product Servicing The Eseye Pelican contains no user serviceable parts; the product should not be dismantled for any reason. 7 Data Portal There are options as to how to access the data reported by the Pelican. One portal that Eseye can supply is emig and it is also possible to obtain API information from Eseye to ensure data flows to a 3 rd party portal. 7.1 emig Portal The data resulting from Pelican use can be viewed in the Energy Meter Information Gateway (emig) which is an online tool for remotely measuring and monitoring use as recorded by the Pelican. emig can provide warnings via and SMS messaging of system failures and abnormal events. Please see more about emig on Pelican APIs Eseye can send the data to a customer url. This section explains the format of the data presented Example of Post Strings Below are a couple of example post strings from a Shoebill/Pelican: imei= &message_id=33630&datetime= :35:36&message=Profile: 15 Interval=30 imei= &message_id=17838&datetime= :05:09&message=Status: Battery=4V, Power=Not Charging, Page 6
8 Location= , , SQ= Messaging Breakdown The IMEI of the device: imei= The unique message ID of the post: message_id=33630 Date of the message origination: datetime= :35:36 Message contents: message=profile: 15 Interval=30 Profile: <range start> : <range end> The IMEI of the device: imei= The unique message ID of the post: message_id=17838 Date of the message origination: datetime= :05: Message Breakdown Illustrations Page 7
9 8 Tracking with Google Earth IMPORTANT NOTE This will require you to have an Eseye Pelican file that can be provided by Eseye. 8.1 How to view the Pelicans 1. Open Google Earth (If you haven t already got it, it s free and easy to download from here 2. Save the Eseye Pelican file to your computer 3. Open the Eseye Pelican file In the Google earth File menu, Your meters will show as they are located. Page 8
STERILE CONTAINER SYSTEMS
»» Extra Long Size EXTRA LONG SIZE 280 mm 710 mm h Specificiations Lid (Perforated) Lid (Perforated) Sizes Box (Non Perforated) Box (Perforated) TK6-2010 TK6-2040 TK6-2011 TK6-2041 h=120 mm TK6-2012 TK6-2013
More informationINSTRUCTIONS FOR USING THIS SAMPLE FLIGHT MANUAL SUPPLEMENT
INSTRUCTIONS FOR USING THIS SAMPLE FLIGHT MANUAL SUPPLEMENT 1. For those installations not installed in accordance with GDL 82 Mooney M20 Series STC SA02573SE, a flight manual supplement may be created
More informationSmart-UPS Installation Guide 750/1000/1500/2200/3000 VA 120/230 Vac 500 VA 100 Vac Tower Important Safety Messages
Smart-UPS Installation Guide 750/1000/1500/2200/3000 VA 120/230 Vac 500 VA 100 Vac Tower Important Safety Messages SAVE THESE INSTUCTIONS - This manuals contains important instructions that should be followed
More informationModel Number Structure
Solid State Relays Refer to Safety Precautions for All Solid State Relays. Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via
More informationOREON GROW LIGHT 2.2
OREON GROW LIGHT 2.2 (GL 600 2.2 XXX) INSTALLATION MANUAL Version: 20180830US/CA IMPORTANT: READ CAREFULLY BEFORE STARTING INSTALLING THE FIXTURE. KEEP FOR FUTURE REFERENCE. MANUAL FOR INSTALLER Thank
More informationEmergency Stop Devices
New! Selection and Application of.. 278 Emergency Stop Rope Pull Switches........... 279 New! Emergency Stop Push Buttons............... 293 Banner Engineering Corp. Minneapolis, MN U.S.A. bannerengineering.com
More informationSTERILE CONTAINER SYSTEMS
»» Extra Long Size EXTRA LONG SIZE 280 mm 710 mm h h 1 Specificiations Lid (with barrier) Lid (with barrier) Box (Non Perforated) Box (with barrier) TK7-2010 TK7-2040 TK7-2011 TK7-2041 TK7-2012 TK7-2013
More informationProduct Guide LED OBSTRUCTION LIGHTS
Product Guide LED OBSTRUCTION LIGHTS Certified to: FAA AC NO: 150/5345-43F FAA Engineering Brief No. 67 Compliant to: ICAO Annex 14, 4th Edition, July 2004 ICAO Aerodromes Design Manual, Chapter 18 Canadian
More informationVideo Media Center - VMC 1000 Getting Started Guide
Video Media Center - VMC 1000 Getting Started Guide Video Media Center - VMC 1000 Getting Started Guide Trademark Information Polycom, the Polycom logo design, Video Media Center, and RSS 2000 are registered
More informationL-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights
L-864 L-865 / L-864 L-810 L-810 Vigilant Series LED Based Obstruction Lights Certified to: FAA AC NO: 150/5345-43F FAA Engineering Brief No. 67 Compliant to: ICAO Annex 14, 4th Edition, July 2004 ICAO
More informationCover...0. Page #...0 TOC Index.0. Inside Back Cover..0. Outside Back Cover 0
Pg Chg Cover...0 Page #......0 TOC-1...0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8. 0 9.0 10..0 11.. 0 12.. 0 13.. 0 14.. 0 15..0 Index.0 Inside Back Cover..0 Outside Back Cover 0 AXP340 Mode S Transponder with ADS-B
More informationAWNING CONTROL KIT 98GCK-33B
AWNING CONTROL KIT 98GCK-33B REV.07282015 RV AWNING PRODUCTS 1361 CALLE AVANZADO, SAN CLEMENTE, CA 92673 (800) 382-8442 FAX (949)276-5500 www.girardrv.com AC MOTOR CONTROL MODULE GC274B INSTALLATION and
More informationSubject: Request for additional information regarding FCC ID: IHDT6EE1 (Portable PCS GSM Transceiver with Embedded Bluetooth)
Date: July 28, 2004 Subject: Request for additional information regarding FCC ID: IHDT6EE1 (Portable PCS GSM Transceiver with Embedded Bluetooth) Reference: Application Received: 07/16/2004 Correspondence
More informationMounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B
A High-capacity, High-dielectricstrength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated coil that handles
More informationGeneral-Use Auto-Tuning HPX-T Series
General-Use Auto-Tuning HPX-T Series Built-in Hyper-tuning automatically adjusts scanning characteristics. Adjustment steps, results and scanning conditions are digitally displayed by LED. Digital display
More informationSafety Interlock Switches
r Safety Interlock Switches TL19 TL19 Safety Interlock Switch with uard Door Locking High locking force of 10 N (270 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure enables
More informationTruma inet Box. Operating instructions Page 2 To be kept in the vehicle!
Truma inet Box Operating instructions Page 2 To be kept in the vehicle! Truma inet Box Table of Contents Symbols used... 14 Intended use... 14 Operating instructions Safety instructions... 15 Display and
More informationElectronic Temperature Controls
ETR-9090 series ETR-9200 series Figure 324 Figure 325 80-260 vac /60Hz PID auto tune/ or 1 set point 3 3 / 8 " depth 1 optional alarm Model Sensor type Output action Alarm ETR9090-121 any thermocouple
More informationModel Crosspoint Matrix
Model 3000 4380 256 Crosspoint Matrix 90401270 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part
More informationEU ECOLABEL USER MANUAL TOURIST ACCOMMODATION Commission Decision for the award of the EU Ecolabel for tourist accommodation (2017/175/EC)
Check-List This checklist (in blue table) summarises the documentation to be provided for each mandatory criterion. The documentation described below has to be submitted to the Competent Body. Applicant
More informationGavita Pro 1650 e LED ML
Pro line Gavita Pro 1650 e LED ML 1 Introduction Thank you for purchasing the Gavita Pro 1650 e LED ML. This manual describes the mounting and installing of the product and also describes how to use the
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-5480 www.cmafh.com Safety Interlock Switches TL19 Safety Interlock Switch with uard Door Locking High
More informationELOQUA INTEGRATION GUIDE
ELOQUA INTEGRATION GUIDE VERSION 2.2 APRIL 2016 DOCUMENT PURPOSE This purpose of this document is to guide clients through the process of integrating Eloqua and the WorkCast Platform and to explain the
More informationHiway Gateway Specification and Technical Data
L Hiway Gateway Specification and Technical Data HG03-400 8/92 detergant coffee chocolate Page 2 TDC 3000 Hiway Gateway Specification and Technical Data Introduction This publication defines the significant
More informationForm 91 Application for Approval of an EFB System
Form 91 Application for Approval of an EFB System This form must be completed by the Flight Representative (FOR) or Operator as recorded on the current Form 20. Please refer to RP4 Guidance to Operators
More informationPower Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops
Power Relay A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated
More informationNH MULTIBLOC fuse-switchdisconnector. terminal version reference no.
NH fuse-switch-disconnector NH fuse-switchdisconnector ~ 690V screw fixing of disconnectors onto plates size rated current in A no. of poles terminal version art. group 00 160 1 screw M8 both sides F229292
More informationPlease read this guide carefully. It tells you how to prepare your cutting plotter for production use in a few easy steps.
OPERATING GUIDE for Secabo mini Cutting Plotter Congratulations on purchasing your Secabo mini cutting plotter! Please read this guide carefully. It tells you how to prepare your cutting plotter for production
More informationTable of Contents. DS107 LUXEON Rebel PLUS Product Datasheet Lumileds Holding B.V. All rights reserved.
Illumination LUXEON Rebel PLUS The original high power LED LUXEON Rebel PLUS is designed with the highest possible efficacy and light output from an industry standard 4530 package with a 2.5mm 2 dome.
More information12V MOTION SENSOR 98GC779G INSTALLATION & PROGRAMMING GUIDE REV RV AWNING PRODUCTS
12V MOTION SENSOR 98GC779G INSTALLATION & PROGRAMMING GUIDE REV.07242015 RV AWNING PRODUCTS 1361 CALLE AVANZADO, SAN CLEMENTE, CA 92673 (800) 382-8442 FAX (949)276-5500 www.girardrv.com Girard Systems
More informationUSER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4
KRAMER ELECTRONICS LTD. USER MANUAL MODEL: Tavor 8-T Active Ceiling Speaker P/N: 2900-300343 Rev 4 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions
More informationC11.15 HANDLES AND LOCKCASES C11 SIDE HUNG WINDOWS
C11 SIDE HUNG WINDOWS C11.15 HANDLES AND LOCKCASES 01.05.2017 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. Handles
More informationSPEDESTER Series QUICK REFERENCE GUIDE
Spedester series Digital DC Drives come with an extensive range of standard software blocks, it can take control of the most demanding motion control tasks. Designed for industrial applications, Spedester
More informationLimit Switches. 6.2 E47 Precision Switches
Limit Switches E47BMS02 E47BMS11 E47BMS40.2 Product Description............................................. 2 Approvals..................................................... 2 Features and Benefits...........................................
More informationGarrecht TRX 1500 Traffic-Sensor
SECTION 9 Pilot s Operating Handbook Supplement Garrecht TRX 1500 Traffic-Sensor This supplement is applicable and must be integrated into the Airplane Flight Manual if a Garrecht Traffic-Sensor is installed
More informationInstallation and Maintenance Manual
Freestanding Gas Stove MODEL: PGS2005 GPEBB20R GPEBW20R Installation and Maintenance Manual Warning Maintenance products should be carried out by professional and technical personnel with relevant qualification,
More informationMX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)
MX40-6043 Series MX40-7XXX Series MX40-6XXX Series Selection Guide Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional control from a DDC system
More informationAquastream. Thermo. Thermostatic integral power shower. Installation guide. Aquastream Thermo installation instructions Page 1
Aquastream Thermo Thermostatic integral power shower Installation guide Aquastream Thermo installation instructions Page 1 Aquastream Thermo Aquastream Thermo Thermostatic integral power shower Satin chrome
More information630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.
SIDERMAT combination 630 to 1800 A sdmat_048_a_1_cat SIDERMAT combination are manually operated tri- or tetrapolar fuse disconnecting switches which can be triggered remotely. They provide breaking and
More informationEC-DECLARATION OF CONFORMITY
EC-DECLARATION OF CONFORMITY Brand: JBL Professional Family Name: VTX Series Suspension Hardware Model Names: VTX-V25-AF, VTX-V25-AF-EB, VTX-V20-AF, VTX-V20-AF-EB, VTX-F12- UB, VTX-F15-UB We, Harman International,
More informationGarmin GNC 420 GPS Navigator with VHF COM
Cirrus Design Section 9 Pilot s Operating Handbook and FAA Approved Airplane Flight Manual Supplement for Garmin GNC 420 GPS Navigator with VHF COM When a GARMIN GNC 420 GPS Navigator with VHF COM is installed
More informationProduct instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E
Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E The Trimfast Ream Cutters are reliable, high performance cutters that will give you the results you need quickly
More informationPGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI
PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI INTRODUCTION The LineGard 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore
More informationTRAFFIC TRANSPONDER / WEATHER. ADS-B compliance is just the beginning. Aviation Products
TRAFFIC TRANSPONDER / WEATHER ADS-B compliance is just the beginning. Aviation Products LYNX ADS-B TRANSPONDER & DISPLAY SYSTEMS ADS-B compliance just got easy. The Lynx ADS-B transponder and display systems
More informationEmergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction
Emergency Stop Switch Install in 22-dia. or 25-dia. Panel Cutout Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1,. Safety Lock Mechanism prevents misuse.
More informationBUILT-IN OVEN SAFETY
UILT-IN OVN SFTY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. lways read and obey all safety messages.
More informationMYOB EXO OnTheGo. Release Notes 1.2
MYOB EXO OnTheGo Release Notes 1.2 Contents Introduction 1 What s New in this Release?... 1 Installation 2 Pre-Install Requirements... 2 Installing the EXO API... 2 Installing EXO OnTheGo... 2 New Features
More informationS&S POWER SWITCHGEAR. Founded by N S Sethuramon and A R Shanthanakrishnan way back in 1978
S&S POWER SWITCHGEAR Founded by N S Sethuramon and A R Shanthanakrishnan way back in 1978 S&S POWER SWITCHGEAR 40 Years of Experience 20,000 Units Installed in Field SF6 Circuit Breakers Vacuum Circuit
More informationQK-CE220RL V02 230V. CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR PLUG & PLAY. 433,92 MHz
user manual QK-CE220RL V02 CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR 230V 433,92 MHz PLUG & PLAY CONTENTS INTRODUCTION MAIN FEATURES OF THE CONTROL BOARD TECHNICAL DATA INSTALLATION LAYOUT AND CONNECTIONS
More informationINFORMATION PAPER ON APPLICATION SPECIFIC MESSAGES (ASM)
INFORMATION PAPER ON APPLICATION SPECIFIC MESSAGES (ASM) Edition 1.1 Version: 09-05-2017 Author: Vessel Tracking and Tracing Expert Group: Sup group ASM Table of Content 1 Inland AIS State of the art...
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches TL4024 Safety Interlock Switch with uard Door Locking High locking force of 1,500 N (7 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure withstands
More informationFIXING THE PLASTIC TO GREENHOUSE STRUCTURE: THE RIGHT CHOICE OPTIONS USED IN LOCKING THE PLASTIC TO GREEENHOUSE STRUCTURE METHODS:
FIXING THE PLASTIC TO GREENHOUSE STRUCTURE: THE RIGHT CHOICE The basic idea of greenhouse agriculture is to provide optimum growing conditions for the plant. Heavy investment is made in making strong greenhouse
More information6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description
.1 PSG Series Contents Description PSG Series Catalog Number Selection................ Technical Data and Specifications.......... Power Derating Curves.................. Dimensions...........................
More informationReferences. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_156_a_2_cat Direct
More information6275-S1 PNEUMATIC DRILL OPERATING MANUAL ORIGINAL INSTRUCTIONS. P/N November 2014 Revision 1
6275-S1 PNEUMATIC DRILL OPERATING MANUAL ORIGINAL INSTRUCTIONS P/N 80749 November 2014 Revision 1 2014 Climax Portable Machining and Welding Systems or its subsidiaries. All rights reserved. Except as
More informationTRT800 ATC Transponder Mode A, A-C, S P/N 800ATC-(1XX)-(1XX) Operation Manual. Document No.: e Revision 1.00 Datum:
TRT800 ATC Transponder Mode A, A-C, S P/N 800ATC-(1XX)-(1XX) Operation Manual Document No.: 03.2101.010.11e Revision 1.00 Datum: 19.04.2006 Gewerbestraße 2 86875 Waal phone: 08246 / 96 99-0 fax: 08246
More informationSupplementary protector S 200 MR for ring-tongue applications acc. to UL 1077
Electrical installations in buildings for ring-tongue applications acc. to UL 1077 S 200 MR is a high-performance supplementary protector with ring cable lug connections conforming to UL, CSA, and IEC
More informationUser manual for awning blind AMZ Z-Wave
GB User manual for awning blind AMZ ZWave Contents 1. Safety standards...2 2. Description...3 3. Programming the appliance...4 4. Association Groups...5 5. Compatibility of other producers appliances in
More information10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC
Solid State Relays G3NE Compact, Low-cost, SSR Switching 5to20 A Wide load voltage range: 75 to 264 VAC. Dedicated, compact aluminum PCB and power elements used. Built-in varistor effectively absorbs external
More informationLOCAL DISCONNECT SWITCHES Manual Motor Controllers
LOCAL DISCONNECT SWITCHES Manual Motor Controllers 1 2 Ensto Manufacturer of electrical components and systems This brochure presents the economical, versatile and reliable Ensto Origin manual motor controllers
More informationSafeSite LED Stainless Steel Linear - ATEX / IECEx for Indoor and Outdoor Industrial Applications
SafeSite LED Stainless Steel Linear - ATEX / IECEx for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 www.dialight.com Dialight_LED_Stainless_Steel_Linear_Specsheet_AtexIECEx_RevI_Jan2018
More informationProgrammable Safety Systems PSS-Range
Programmable Safety Systems PSS-Range PROFIBUS-DP for Compact 3rd Generation PSS Operating Manual Item No. 20 962-04 All rights to this manual are reserved by Pilz GmbH & Co. KG. Copies may be made for
More informationA11.15 HANDLES AND LOCKCASES A11 TURN-TILT WINDOWS
A11 TURN-TILT WINDOWS A11.15 HANDLES AND LOCKCASES 01.05.2017 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. Handles
More information212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad
International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad Stand Alone Keypad-Installation Manual Features: 120 User Capability
More informationPROCESS BURNERS INSTALLATION, COMMISSIONING AND MAINTENANCE MANUAL HMA2A SERIES AIR HEATING BURNERS
PROCESS BURNERS INSTALLATION, COMMISSIONING AND MAINTENANCE MANUAL HMA2A SERIES AIR HEATING BURNERS The information contained in this manual is advisory and in general terms only and does not constitute
More informationUSER INFORMATION For AcuTemp PX1L Carrying Case and AcuTemp PXC Coolant Packs (Formerly VaxiPac and VaxiSafe )
USER INFORMATION For AcuTemp PX1L Carrying Case and AcuTemp PXC Coolant Packs (Formerly VaxiPac and VaxiSafe ) AcuTemp Thermal Systems 2900 Dryden Road Dayton, Ohio 45439 U.S.A. Tel: 937.312.0114 Fax:
More informationSINGLE BURNER STOVE IMPORTANT OPERATING INSTRUCTIONS COOKING & STORAGE POSITION PARTS IDENTIFICATION
SINGLE BURNER STOVE OPERATING INSTRUCTIONS PARTS IDENTIFICATION Electronic Lighter Ignites the burner. Liquid Guard Holds liquid overflow. Windshield Prevents flame from being extinguished by wind. Ensures
More informationNordic ID HH53 User Guide Version 1.0 NORDIC ID HH53 USER GUIDE
NORDIC ID HH53 USER GUIDE TABLE OF CONTENTS GETTING STARTED... 3 1.1. GENERAL... 3 1.2. VARIANTS... 3 NORDIC ID HH53 VARIANTS... 3 1.3. AVAILABLE ACCESSORIES... 4 1.4. INBOX CONTENT... 4 1.5. INSTALLING
More informationcode: NEWS _EN s/p LED 2016 NEWS 03 D U R A S T R I P -EN
ED 2016 EN NEWS 03 D U R A S T R I P 2 Technical data are subject to tolerances and may vary; any update is published on the website www.duralamp.it THE NEW SEECT RANGE: QUAITY STRIPS FOR ANY BUDGET ED
More informationInstallation Guide Smart-UPS C 1000/1500 VA 120/230 Vac 2000/3000 VA 230 Vac Rack-Mount 2U
Installation Guide Smart-UPS C 1000/1500 VA 120/230 Vac 2000/3000 VA 230 Vac Rack-Mount 2U Important Safety Messages SAVE THESE INSTUCTIONS - This manuals contains important instructions that should be
More informationSafeSite. Series LED Based Signaling for Hazardous Locations
SafeSite Series LED Based Signaling for Hazardous Locations Index 02 SafeSite L-864 Red LED Beacon 03 SafeSite LED Based L-864/L-865 Flashing Dual (White/Red) Strobe 04 SafeSite L-810 Red LED Obstruction
More informationSIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution sdmat_048_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationelectric knife sharpener
electric knife sharpener USER GUIDE Now that you have purchased a Kitchen Living product you can rest assured in the knowledge that as well as your year parts and labour guarantee you have the added peace
More informationClay Adaptors & Insert Stove Kits
Clay Adaptors & Insert Stove Kits September 2014 Tel: +353 46 95 58030 Fax: +353 46 95 58034 Email: sales@miflues.ie Web: www. miflues.ie INTRODUCTION CLAY ADAPTORS Mi-Flues Clay Adaptors are specially
More informationSurge-Trap Pluggable STPT2 Series - 40kA
EDS1249-001 Surge-TraEDp Pluggable STPT2 Series - 40kA Surge-Trap Pluggable STPT2 Series - 40kA SURGE PROTECTION FOR POWER LINES DIN-RAIL IEC TYPE 2 / CLASS II FEATURES & BENEFITS Maximum discharge current
More informationBlue Series Hot Melt Hose with RediFlext II Hanger System
Instruction Sheet P/N 1124594_01 Blue Series Hot Melt Hose with RediFlext II Hanger System Safety WARNING! Allow only personnel with appropriate training and experience to operate or service the equipment.
More informationUM1868. The BlueNRG and BlueNRG-MS information register (IFR) User manual. Introduction
User manual The BlueNRG and BlueNRG-MS information register (IFR) Introduction This user manual describes the information register (IFR) of the BlueNRG and BlueNRG-MS devices and provides related programming
More informationSERVICE BULLETIN TITLE NAVIGATION - GARMIN G1000 ENHANCED SEARCH AND RESCUE ENABLEMENT
TITLE NAVIGATION - GARMIN G1000 ENHANCED SEARCH AND RESCUE ENABLEMENT EFFECTIVITY The following G1000-equipped airplanes with system software version 0563.24 (or later) installed: MODEL 172R 172S 182T
More informationPower Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -
SVL Essential DIN Rail Series SVL Series power supplies are perfect for high volume, controlled environment applications where essential features are the only requirement. When space inside an enclosure
More informationLegacy Basic Acoustical Shell
Owner s Manual Legacy Basic Acoustical Shell CONTENTS Safety Precautions.................................. 2 General....................................... 2 Set Up and Usage..............................
More informationFIBER OPTIC CLOSURES
FIBER OPTIC CLOSURES In-line type and dome type - series CLS-I, CLS- IF2X, CLS-D, CLS-DF2X144 and CLS-DF2X240 PACIFIC INTERCONNECTIONS - connecting the world with fiber optics IN-LINE TYPE FIBER OPTIC
More informationModule TW8. Level crossings - drivers instructions. GE/RT8000/TW8 Rule Book. Issue 7. September 2015
GE/RT8000/TW8 Rule Book Module TW8 Level crossings - drivers instructions Issue 7 September 2015 Comes into force 05 December 2015 Published by: RSSB The authoritative version of this document is available
More informationDJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing
Pushbuttons toggle switch 6,35 mm dia. toggle switch 6,35 mm dia. no. of poles material of contacts Switching position connection method colour part no. 2 silver 2 (maintained chromiumplated 02.17312.21
More informationQuick Start Guide 3500 AquaVent
Quick Start Guide 3500 AquaVent Please read this document carefully before using the AquaVent. High Quality Groundwater and Surface Water Monitoring Instrumentation Note: For information on using your
More informationXENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL
TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product 996A106032 TUM 1024 REV. E 06.02.14 Tranberg AS P.O. Box 8033 N-4068 Stavanger
More information2013 Taiwan Innovative Unmanned Aircraft Design Competition
2013 Taiwan Innovative Unmanned Aircraft Design Competition Fundamental Motor-Powered Cargo UAV I. Date, Location and Grading Revised: 2012/08/06 1. Date: The competition is planed to be held on March
More informationAssembling & Fitting Instruction August 2015
Assembling & Fitting Instruction August 2015 Wave Curtain Heading System Silent Gliss 6010, 6020, 6100, 6103, 6290, 6380, 6465 Silent Gliss 3840, 6120 Silent Gliss 5090, 5200, 5400 Silent Gliss 5100, 5600
More informationUniversal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W
isolating General Data Rated input voltage 208 - Rated output voltage 24-230 Vac Rated power 100-3200 VA Insulation class B Maximum ambient temperature 40 C Efficiency up to 96 % Degree of protection IP
More informationAluminum Extendable Trolley
L_060_13_Anl-Alu-Rollw-.pdf 1 12.02.14 09:32 Aluminum Extendable Trolley User manual English... 2 1877 318 8039 Type: ARW-150 L_060_13_Anl-Alu-Rollw-.pdf 2 12.02.14 09:32 ALUMINUM EXTENDABLE TROLLEY OUR
More informationFagronLab FG. Semi-automatic capsule filling machine. User Manual
Semi-automatic capsule filling machine User Manual Table of contents 1. Introduction... 4 2. Service.. 4 3. Warranty... 4 4. Overview... 5 System features... 5 FagronLab FG-1 Filler Base & Orienter Base...
More informationApplications: MultiCam Knife Accessories. Signs and Graphics Digital Print Cutting Packaging Aerospace And More
MultiCam Knife Accessories Complete EZ Knife Accessory Line Enhances Any Application MultiCam developed the EZ Knife System to serve markets that require mechanized knife cutting, creasing and perforation
More informationRoller Coaster Information Sheet Please Print Roller Coasters will NOT be allowed on the stage for judging unless they are accompanied by this sheet School Name: Teacher Name: Coaster Name: Members of
More informationStorybook Theme Park Ride
Storybook Theme Park Ride Level: Elementary School Type of Contest: Team Composition of Team: 2 4 students per team Number of Teams: One entry per school Next Generation Science Standards: 3-5-ETS1-1.,
More informationAntenna Tower Positioning System
Model 1052 Antenna Tower Positioning System User Manual (Antenna not included) ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design,
More informationSOLHARO ASSEMBLY & INSTALLATION INSTRUCT IONS
A. Introduction: SOLHARO ASSEMBLY & INSTALLATION INSTRUCT IONS Rev. 01/30/2012 The Solharo is an external, retractable, tensioned sun shading system designed to fit over a sunroom or wood pergola. The
More informationHardSID Uno / UPlay user s guide HardSID Uno HardSID UPlay
HardSID Uno / UPlay user s guide HardSID Uno HardSID UPlay HardSID Uno / UPlay user s guide 2010 Hard Software, Hungary 1 Safety information... 4 Introduction:... 5 Package contents... 5 System requirements...
More informationAREMA C&S Manual Index (Includes 2018 Revisions) Volume SECTION 3 - HIGHWAY RAIL GRADE CROSSING WARNING SYSTEMS
SECTION 3 - HIGHWAY RAIL GRADE CROSSING WARNING SYSTEMS 3.1 General Recommendations 3.1.1 36-1 Recommended Guidelines for Grade Crossing Warning Devices 5 Reaffirmed 2017 3.1.5 36-1 Recommended References
More informationA3200 Automation Controller Hardware Manual
RESET A3200 Automation Controller Hardware Manual Revision: 1.02.00 AEROTECH.COM Motion Server AEROTECH.com POWER HDD/SSD Automation Controller 4U Rack Mount POWER SUPPLY 240V~ MAX 50/60Hz 10A MAX L N
More informationFlammable and Combustible Liquids. OSHA Office of Training and Education 1
Flammable and Combustible Liquids OSHA Office of Training and Education 1 Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and
More informationPower Tong Torque Manual
Power Tong Torque Manual 1 Contents Power Tong Torque Monitor 1. Description:... 3 2. System Functions:... 3 3. Future Optional Functionality:... 3 4. Panel Display and Operation:... 6 4.1. Setting the
More information