a Nexans company Catalogue 2009
|
|
- Aldous Jefferson
- 6 years ago
- Views:
Transcription
1 a Nexans company Catalogue 2009
2 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: pre-moulded EPDM or silicone rubber connectors, terminations and joints for cables and epoxy s for transformers and switch gear, as well as a large range of cold-shrinkable terminations and joints from to 42 kv. Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group. ISO 9001 Certificate Since 1992, Euromold s commitment to quality is demonstrated by its ISO 9001 certification. International All our products meet the International like CENELEC HD 629.1, CENELEC EN 50180, IEC 137, IEEE 386 & 404 or country specifications. Official certificates, CESI, KEMA, ATEX prove the conformity of our products. Long duration tests of existing or new products are continuously performed in our test fields. Laboratory accreditation Since June 2000, Euromold s independent ELAB laboratory obtained the BELTEST accreditation no.192-t-iso conform with the European for laboratories ISO for electrical testing of medium voltage cable accessories according to the International IEC and HD 629. While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions n.v. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as and technology evolve. 1
3 EQUIPMENT BUSHINGS Table of contents 180AR-1 - interface A 180AR-2 - interface A 180AR-3 - interface A 180A-P-O - interface A in-air 250SFR-P - interface A 400T1 - interface B 400AR-1 - interface B 400AR-2 - interface B 400SFR-P - interface B 400AR-3 - interface C 400AR-4 - interface C 400AR-5 - interface C 400AR-6 - interface C 400A-B - interface C in-air 400SFR-B - interface C 2
4 Interface A Dimensions according to European CENELEC EN and (in mm). Dia ±0.2 Dia ±0.2 Dia Dia. for pin min. Dia ±0.2 Interface B Dimensions according to European CENELEC EN and (in mm). Dia. 56 ±0.2 Dia. 46 ±0.2 Dia. for pin min. 90 ± min. Dia. 70 ±0.2 Interface C Dimensions according to European CENELEC EN and (in mm). Dia. 56 ±0.2 Dia. 46 ±0.2 Dia. 22 min. M16 x 2-6H min. 90 ± min. Dia. 70 ±0.2 3
5 180AR-1 /180AR-2 /180AR-3 INTERFACE A EQUIPMENT BUSHINGS Application For use in insulated with oil fluid, typically for transformers, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. Specifications and The plug-in type s 180AR- meet the requirements of CENELEC EN and IEC 137. Up to kv A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Design The s are moulded epoxy insulated parts in accordance with CENELEC EN The 180AR-2 has a length B outside this standard. The standard s, (K)180AR-1 /-2 /-3, are equipped with 6 tabs for the bail restraint. The (K)180AR-1-G and (K)180AR-3-G are equipped with 4 tabs and 2 threaded inserts M6 (-G version). Type 180AR-1-G /-3-G Type 180AR-1 /-2 /-3 M A B To order the, specify the type. The s are supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. K180AR-1/J. Minimum oil level: - kv: 40 mm - kv: 50 mm Dia. 16 Dia. 75 Dia. 110 M10 19 Equipment type Voltage Ur (kv) Current Ir (A) A Dimensions (mm) B 180AR-1 K180AR-1 180AR-2 K180AR-2 180AR-3 K180AR
6 180AR-1/GS 180AR-1-G/GS 180AR-2/GS 180AR-3/GS and 180AR-3-G/GS Bushings To order the clamping kit, according to NFC , simply specify KBCNF Contents: - 3 x claw clamp NF - 1 x sealing gasket. FIXINGS FOR EQUIPMENT BUSHINGS 180AR-1/J 180AR-1-G/J 180AR-2/J 180AR-3/J and 180AR-3-G/J Bushings To order the clamping kit, according to DIN , simply specify: KBCD-200. Contents: - 1 x fixing flange A - 4 x stud clamp E - 1 x sealing gasket. interface fixing studs NF C clamp E DIN stud clamp sealing gasket tabs for bail restraint A DIN fixing flange earth plate earth jumper Fixing dimensions NF C French. Fixing dimensions DIN German. M8 or M10 M fixing studs Dia. 78 Dia. 6 4 fixing studs Dia. 78 Dia. 3 5
7 Application For use in insulated with air, typically for dry type transformers, motors, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 180A-P-O INTERFACE A IN-AIR BUSHING Up to kv A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Specifications and The plug-in type s 180A-P-O are moulded epoxy insulated parts and meet the requirements of CENELEC EN and IEC 137. Dia A Dia. 110 To order the, specify the type. The s are supplied with an earth jumper. To include the ring clamp, add: /B, if per British /D, if per German /F, if per French. E.g. 180A-P-O/F Dia B Dia. 80 M10 Equipment type Voltage Ur (kv) Current Ir (A) Creepage distance A-B (mm) 180A-P-O 180A-P-O
8 180A-P-O In-air interface fixing studs and nuts M10 earth jumper FIXINGS FOR EQUIPMENT BUSHINGS gasket fixing flange BCA-B or BCA-D fixing flange BCA-F F tabs for bail restraint Dia Dia Dia. 10 Dia Dia Dia F 6 BS 2562 stand.: 0 DIN stand.: 3 Dia. 150 Type BCA-B : BS 2562 British Type BCA-D : DIN German Fixing dimensions DIN German. M Dia. 150 Type BCA-F : NFC French M8 or M Fixing dimensions NF C French. 4 fixing studs 3 fixing studs Dia. 82 Dia. 3 Dia. 82 Dia. 6 7
9 Application For use in insulated with SF 6 gas. Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 250SFR-P INTERFACE A EQUIPMENT BUSHING Up to kv A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Design The is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN The 250SFR-P has a shank outside this standard, adapted to use in SF 6 gas. Specifications and The plug-in type s 250SFR-P meet the requirements of CENELEC EN and IEC 137. Dia. 70 Dia To order the, simply specify the type. M10 Dia. 20 Dia. 70 Dia. 109 Equipment type Voltage Ur (kv) Current Ir (A) 250SFR-P K250SFR-P
10 FIXINGS FOR EQUIPMENT BUSHINGS 250SFR-P Bushing for gas insulated switch gear UNMOUNTED M4 83 M6 Dia Dia MOUNTED interface 6 fixing screws M6 sealing O-ring gasket earth M4 9
11 400T1 /400AR-1 /400AR-2 INTERFACE B EQUIPMENT BUSHINGS Application For use in insulated with oil fluid, typically for transformers, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. Up to kv A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/ () kv Specifications and The plug-in type s are moulded epoxy insulated parts and meet the requirements of IEC 137. The (K)(M)400T1 also meets CENELEC EN C To order the, specify the type. The s are supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. K400AR-1/J. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 70 mm Dia. H B A E Dia. 70 Dia. F Dia. G D In mm Equipment type Voltage Ur (kv) Current Ir (A) Dimensions (mm) A B C D E Dia. F Dia. G Dia. H 400T1 K400T1 M400T1 400AR-1 K400AR-1 M400AR-1 400AR-2 K400AR-2 M400AR M M M M M M M16 M16 M
12 400AR-2/GS Bushing To order the clamping kit, according to NFC , simply specify KBCNF-400 (for type 400AR-2). Contents: - 4 x claw clamp NF - 1 x sealing gasket. FIXINGS FOR EQUIPMENT BUSHINGS 400AR-1/J and 400T1/J Bushings To order the clamping kit, simply specify: KBCD-400B. Contents: - 1 x fixing flange B - 6 x stud clamp E - 1 x sealing gasket. interface fixing studs NF C claw clamp fixing flange B DIN E DIN stud clamp sealing gasket tabs for the bail restraint earth jumper earth plate Fixing dimensions NF C French. Fixing dimensions DIN German. M10 or M M10 50 to fixing studs Dia. 105 Dia fixing studs Dia. 90 Dia. 140 In mm 11
13 Application For use in insulated with SF 6 gas. Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400SFR-P INTERFACE B EQUIPMENT BUSHING Up to kv A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Design The is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN The 400SFR-P has a shank outside this standard, adapted for use in SF 6 gas. Dia Specifications and The plug-in type 400SFR-P meets the requirements of CENELEC EN and IEC To order the, simply specify the type. 95 Dia. 25 Dia. 70 Dia. 109 M Equipment type Voltage Ur (kv) Current Ir (A) 400SFR-P K400SFR-P
14 FIXINGS FOR EQUIPMENT BUSHINGS 400SFR-P Bushing for gas insulated switch gear UNMOUNTED M4 83 M6 Dia Dia MOUNTED interface 6 fixing screws M6 sealing O-ring gasket earth M4 13
15 Application For use in insulated with oil fluid, typically for transformers, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400AR-3 INTERFACE C EQUIPMENT BUSHING Up to kv - 6 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/ () kv Specifications and The bolted type s 400AR-3 are moulded epoxy insulated parts and meet the requirements of CENELEC EN and IEC To order the, specify the type. The s can be supplied with an earth jumper (/J). E.g. M400AR-3/J. For use in potentially explosive atmospheres (for kv max), order: 400AR-3/ATEX. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 70 mm Dia M16 Dia. 70 Dia. 88 Dia. 8 Equipment type Voltage Ur (kv) Current Ir (A) 400AR-3 K400AR-3 M400AR
16 400AR-3/J Bushing FIXINGS FOR EQUIPMENT BUSHINGS To order the clamping kit, according to DIN , simply specify KBCD-400B. Contents: - 1 x fixing flange B - 6 x stud clamp E - 1 x sealing gasket. Fixing dimensions DIN German. M interface fixing studs B DIN fixing flange E DIN stud clamp 6 fixing studs Dia. 90 Dia. 140 sealing gasket earth jumper 15
17 Application For use in insulated with oil fluid, typically for transformers, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400AR-4 INTERFACE C EQUIPMENT BUSHING Up to kv - 50 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/ () kv Specifications and The bolted type s 400AR-4 are moulded epoxy insulated parts and meet the requirements of CENELEC EN and IEC To order the, specify the type. The s can be supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. M400AR-4/GS. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 70 mm Dia M16 Dia. 70 Dia. 100 Dia. 150 Equipment type Voltage Ur (kv) Current Ir (A) 400AR-4 K400AR-4 M400AR
18 400AR-4/GS Bushing FIXINGS FOR EQUIPMENT BUSHINGS To order the clamping kit, according to NFC , simply specify KBCNF-400. Contents: - 4 x claw clamp NF - 1 x sealing gasket. Fixing dimensions NF C French. M10 or M 50 to 70 interface fixing studs 4 fixing studs Dia. 105 Dia. 171 NF C claw clamp sealing gasket earth plate 17
19 Application For use in insulated with oil fluid, typically for transformers, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400AR-5 INTERFACE C EQUIPMENT BUSHING Up to kv - 50 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/ () kv Specifications and The bolted type s 400AR-5 are moulded epoxy insulated parts and meet the requirements of CENELEC EN and IEC To order the, specify the type. The s can be supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. M400AR-5/GS. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 70 mm Dia M16 Dia. 76 Dia. 150 Equipment type Voltage Ur (kv) Current Ir (A) 400AR-5 K400AR-5 M400AR
20 400AR-5/GS Bushing FIXINGS FOR EQUIPMENT BUSHINGS To order the clamping kit, according to NFC , simply specify KBCNF-400. Contents: - 4 x claw clamp NF - 1 x sealing gasket. Fixing dimensions NF C French. M10 or M interface 50 to 70 fixing studs 4 fixing studs Dia. 81 Dia. 171 NF C claw clamp sealing gasket earth plate 19
21 Application For use in insulated with oil fluid, typically for transformers, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400AR-6 INTERFACE C EQUIPMENT BUSHING Up to kv - 6 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/ () kv Specifications and The bolted type s 400AR-6 are moulded epoxy insulated parts and meet the requirements of CENELEC EN and IEC 137. To order the, specify the type. The s can be supplied with an earth jumper (/J). This earth must be specified when ordering. E.g. M400AR-6/J Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 70 mm Dia Dia. 70 Dia. 88 Dia. 8 M16 Equipment type Voltage Ur (kv) Current Ir (A) 400AR-6 K400AR-6 M400AR
22 400AR-6/J Bushing FIXINGS FOR EQUIPMENT BUSHINGS To order the clamping kit, according to DIN , simply specify KBCD-400B. Contents: - 1 x fixing flange B - 6 x stud clamp E - 1 x sealing gasket. Fixing dimensions DIN German. interface fixing studs M fixing flange B DIN E DIN stud clamp 6 fixing studs Dia. 80 Dia. 140 sealing gasket earth jumper 21
23 Application For use in insulated with air, typically for dry type transformers, motors, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400A-B INTERFACE C IN-AIR BUSHING Up to kv - 6 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Specifications and The bolted type s 400A-B are moulded epoxy insulated parts and meet the requirements of CENELEC EN and IEC To order the, specify the type. The s are supplied with an earth jumper. To include the ring clamp, add: /B, if per British /D, if per German /F, if per French. E.g. 400A-B/D. For use in potentially explosive atmospheres (for kv max), order: -/ATEX. A Dia. 80 Dia. 110 Dia B Dia. 80 M16 Equipment type Voltage Ur (kv) Current Ir (A) Creepage distance A-B (mm) 400A-B 400A-B
24 400A-B In-air FIXINGS FOR EQUIPMENT BUSHINGS interface fixing studs and nuts M10 earth jumper gasket fixing flange BCA-B or BCA-D fixing flange BCA-F F Dia Dia Dia. 10 Dia. 10 Dia Dia F 6 BS 2562 stand.: 0 DIN stand.: 3 Dia. 150 Type BCA-B : BS 2562 British Type BCA-D : DIN German Fixing dimensions DIN German. 0 Dia. 150 Type BCA-F : NFC French Fixing dimensions NF C French. M10 M8 or M fixing studs 3 fixing studs Dia. 82 Dia. 3 Dia. 82 Dia. 6 In mm 23
25 Application For use in insulated with SF 6 gas. Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400SFR-B INTERFACE C EQUIPMENT BUSHING Up to kv 6 A & 50 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Design The is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN The 400SFR-B has a shank outside this standard, adapted to use in SF 6 gas. Dia Specifications and The bolted type 400SFR-B meets the requirements of CENELEC EN and IEC To order the, simply specify the type. M Dia. D Dia. 70 Dia. 109 Equipment type Voltage Ur (kv) Current Ir (A) Dia. D (mm) 400SFR-B K400SFR-B M400SFR-B 400SFR-B 50 A K400SFR-B 50 A M400SFR-B 50 A
26 FIXINGS FOR EQUIPMENT BUSHINGS 400SFR-B Bushing for gas insulated switch gear UNMOUNTED M4 83 M6 Dia Dia MOUNTED interface 6 fixing screws M6 sealing O-ring gasket earth M4 25
27 Additional catalogue information on power cable accessories is available by contacting us at the address below: Distributed by: Nexans Network Solutions N.V. - Div. Euromold Zuid III, Industrielaan, B-9320 Erembodegem Tel.: +32 (0) Fax: +32 (0) info.euromold@nexans.com Catalogue also available on CD-ROM
Molded High-Voltage Bushing Wells
66-10 Molded High-voltage Bushing Wells Howard Industries Components Division Molded High-Voltage Bushing Wells Catalog Section 66-10 INTRODUCTION Howard Industries molded high-voltage bushing wells are
More informationSIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution sdmat_048_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationNH MULTIBLOC fuse-switchdisconnector. terminal version reference no.
NH fuse-switch-disconnector NH fuse-switchdisconnector ~ 690V screw fixing of disconnectors onto plates size rated current in A no. of poles terminal version art. group 00 160 1 screw M8 both sides F229292
More informationFLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing
FLFE..L FLF..L - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time Ex e terminal board housing Simplified maintenance 4 Joule shock resistant borosilicate glass White painted
More informationSpare parts list ( ) Spare parts list BR 40/10 C
Spare parts list (59708360) Spare parts list BR 40/10 C 2011-05-09 www.kaercher.com EN Spare parts list BR 40/10 C (59708360)... 6 10 Retaining bracket and switch (02010300)... 7 11 Retaining bracket
More informationSERVICE SHEET 34" WALK-BEHIND POWER TROWEL MODEL FT34 (THIS SERVICE SHEET APPLIES TO THE TROWELS WITH SERIAL NUMBER AND AFTER) WARNING
34" WALK-BEHIND POWER TROWEL (THIS APPLIES TO THE TROWELS WITH SERIAL NUMBER 0837 AND AFTER) WARNING To reduce the risk of injury, all operators and maintenance personnel must read and understand these
More informationS36 230V MOTOR COVER
S36 230V MOTOR COVER S36 230V MOTOR COVER Pos Article Number Description QTY 1 590450601 AC FOAM PACKING 1 2 590396701 MANOMETER KIT 1 3 590415301 COUNTER SET 1 4 590450201 CORD SET PACKING 1 5 590449601
More information630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.
SIDERMAT combination 630 to 1800 A sdmat_048_a_1_cat SIDERMAT combination are manually operated tri- or tetrapolar fuse disconnecting switches which can be triggered remotely. They provide breaking and
More informationAPV PUMPS. Puma Pump Series III FREEPHONE: Pump assembly (Series III) Shrouded Type. Unshrouded Type
Puma Pump Series III Shrouded Type Unshrouded Type 2 Pump assembly (Series III) Freephone lines are open between 8.00am and 5.30pm Monday to Friday FREEFAX: 0800 801404 PUMA PUMP SERIES III (PAGE 2) PUMP
More informationSmallest Connector with Removable Contacts
1 Ultra-Miniature 8STA Size 01 Connectors Smallest Connector with Removable Contacts Ultra compact design and very lightweight connector dedicated to the harshest of motorsport environments. Innovative
More informationSpare parts list ( ) Spare parts list BR 30/4 C Bp
Spare parts list (59712300) Spare parts list BR 30/4 C Bp 2011-05-09 www.kaercher.com EN Spare parts list BR 30/4 C Bp (59712300)... 6 10 Housing individual parts (02096890)... 7 11 Housing (02096900)...
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION ISO 900 Certification was achieved in December 997, and reflects the strict adherence to quality management techniques from the first day of production. This certification was given
More informationV 50.1 BR2. Vario Clamp Spare Parts List (until week 13/2013) Spare parts
Vario Clamp Spare Parts List (until week 13/2013) V 50.1 BR2 Spare parts Pos. Part-No. Quantity Description Type Flag 1 10 232038 1 housing complete V 50.1 20 232000 1 cylinder tube V 50.1 30 276993 1
More informationFIBER OPTIC CLOSURES
FIBER OPTIC CLOSURES In-line type and dome type - series CLS-I, CLS- IF2X, CLS-D, CLS-DF2X144 and CLS-DF2X240 PACIFIC INTERCONNECTIONS - connecting the world with fiber optics IN-LINE TYPE FIBER OPTIC
More informationCOLGED. Isytech
COLGED SPARE PARTS CATALOGUE ERSATZTEILKATALOG CATALOGUE PIECES DETACHEES CATALOGO PARTI RICAMBIO CATALOGO DE PIEZAS DE RECAMBIO CATALOGO PECAS, DE REPOSICAO Isytech -0. --0 9 0 R L 8 4 8 0 L R 4 MOD T0
More informationParts Catalog. Slicing Machine G10. Model:
, 07 995079 ECN 96 Parts Catalog Slicing Machine G0 Model: G0 /8/7N Rev. E, Serial Number 4048 and Up IMPORTANT! TO EXPEDITE SHIPMENT OF PARTS, ALWAYS SPECIFY MODEL, REV, PART NUMBER, AND SERIAL NUMBER
More informationPower Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops
Power Relay A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated
More informationMounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B
A High-capacity, High-dielectricstrength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated coil that handles
More informationXENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL
TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product 996A106032 TUM 1024 REV. E 06.02.14 Tranberg AS P.O. Box 8033 N-4068 Stavanger
More informationTherme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions
Therme storage water heater Table of contents Symbols used... 8 Installation instructions Water supply... 9 Choice of location... 9 Installation of the Therme... 9 Fitting the draining and venting valve...
More informationNK Multi-stage submersible pumps
NK Multi-stage submersible pumps PERFORMANCE RANGE Flow rate up to 120 l/min (7.2 m³/h) Head up to 10 m APPLICATION LIMITS Maximum liquid temperature +40 C Maximum sand content 0 g/m³ 20 m maximum immersion
More informationAmphenol RF Interconnects TNC 31 Series Threaded Lock RF Connector System Materials
TNC 31 Series Threaded Lock RF Connector System Materials Body/Finish Contacts Centre MALE Centre FEMALE Insulator Gasket Crimp Ferrules* *Metal finishes Durability Brass/Nickel Brass/Gold Plated (Au)
More informationSpecial Three-Phase Motors with HSK-C Tool Holder for Manual Quick Tool Change
Special Three-Phase Motors with HSK-C Tool Holder for Manual Quick Tool Change Catalogue 21 E High speed three-phase motors with HSK-C tool holder for manual tool change protection type: IP54 Motor description
More information2M804 Push-Pull Crimp Receptacles Ordering Guide for 2M , 002, 003, 004
Push-Pull Crimp Receptacles Ordering Guide for -001, 002, 003, 004 Micro38999 1. 2. 3. 4. 5. 6. 7. SERIES SHELL SERVICE SHELL SIZE-INSERT CONTACTS KEYING SUFFIX STYLE CLASS ARANGEMENT -00X -06 ZNU 6-7
More informationProduct Range. Switches Spur Units Sockets Communication Accessories Other Modules Front Plates & Frames 23-28
Interplast is a member of the Harwal Group of companies, and is an internationally recognized manufacturer of technical solutions to the electrical industry with a strong commitment to quality and service
More informationUltraflow Compact Housing and Winter Kit
Ultraflow Compact Housing and Winter Kit Operating instructions Page 2 Installation instructions Page 8 To be kept in the vehicle! Comfort on the move Ultraflow Compact Housing and Winter Kit 1 Compact
More informationSupplementary protector S 200 MR for ring-tongue applications acc. to UL 1077
Electrical installations in buildings for ring-tongue applications acc. to UL 1077 S 200 MR is a high-performance supplementary protector with ring cable lug connections conforming to UL, CSA, and IEC
More information10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC
Solid State Relays G3NE Compact, Low-cost, SSR Switching 5to20 A Wide load voltage range: 75 to 264 VAC. Dedicated, compact aluminum PCB and power elements used. Built-in varistor effectively absorbs external
More informationSection B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1
Parts B - Section B Parts. Introduction To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use the parts list, and the accompanying illustration, to describe
More informationAXELENT WIRE TRAY Wire Trays, Fittings, Mountings and Accessories. Technical manual
AELENT WIRE TRAY Wire Trays, Fittings, Mountings and Accessories Technical manual ver. 02-2015 Article Page Article Page 1 Fitting 11 2 Fitting 11 3 Angled Fitting 11 4 Fitting 11 5 Joining Fitting 11
More informationSpare parts list PVX open loop CW
Spare parts list PVX-066... 250 open loop CW Directory 1 Spare parts (general) 3 2 Basic pump 2.1 Basic pump explosion view 4 2.2 Basic pump rotating group 1 5 2.3 Basic pump rotating group 2 6 2.4 Basic
More informationBlue Series Hot Melt Hose with RediFlext II Hanger System
Instruction Sheet P/N 1124594_01 Blue Series Hot Melt Hose with RediFlext II Hanger System Safety WARNING! Allow only personnel with appropriate training and experience to operate or service the equipment.
More informationSection B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1
Parts B - Section B Parts. Introduction To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use the parts list, and the accompanying illustration, to describe
More informationUniversal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W
isolating General Data Rated input voltage 208 - Rated output voltage 24-230 Vac Rated power 100-3200 VA Insulation class B Maximum ambient temperature 40 C Efficiency up to 96 % Degree of protection IP
More informationtttttt www.wealdelectronics.com This publication is issued to provide outline information only and unless specifically agreed to the contrary by WEALD ELECTRONICS LTD. in writing, is not to form part of
More informationTotal solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL
Total solder points: 129 Difficulty level: beginner 1 2 3 4 5 advanced LIQUID LEVEL CONTROLLER K2639 Forgotten to turn off the tap, leaking washing machines,... Prevention is better than cure. So use this
More informationGrounding Clamp. Pins and Ball-Socket Clamps for Temporary Grounding
Grounding Clamp Pins and Ball-Socket Clamps for Temporary Grounding Pins and Ball-Socket Clamps have been designed to solve several temporary grounding situations, where the physical space or the contact
More informationEmergency Stop Devices
New! Selection and Application of.. 278 Emergency Stop Rope Pull Switches........... 279 New! Emergency Stop Push Buttons............... 293 Banner Engineering Corp. Minneapolis, MN U.S.A. bannerengineering.com
More informationAXICOM COMPOSITE HOLLOW CORE INSULATORS STANDARD TYPES
AXICOM COMPOSITE HOLLOW CORE INSULATORS STANDARD TYPES Normal sheds 2 AXICOM composite hollow core Table of contents Table of contents Presentation 3 I Normal sheds How to design your own AXICOM Insulator?
More informationGeneral Purpose High Power PCB Relays
T9 Series Two-pole 3A PCB or Panel Mount Relay n A, form A (NO) and form C (CO) switching capability n Designed to control compressor loads to 3.5 tons, LRA / 5.3FLA n Meets requirements of UL 58 and UL
More informationAutomatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind.
Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind. Available materials: Steel, powder coated, RAL7032, RAL3000 (Application
More informationPARTS LIST eforce Burnisher
PARTS LIST eforce Burnisher HEAD ASSEMBLY ITEM PART NO. DESCRIPTION QTY 101 6496721 MOTOR 36 VOLT, 2100 RPM, 3.6HP [see pages 16,17] 1 102 9121410 5/16 EXTERNAL STAR LOCK WASHER PACK OF 10 2 103 6492051
More informationPARTS LIST CHARGER 2022 ABLT
PARTS LIST CHARGER 2022 ABLT HEAD ASSEMBLY ITEM PART NO. DESCRIPTION QTY 101 5990731 SPRING CLIP PAD HOLDER SET INCLUDES: 1 101A 9120205 #8 X 1/2 PAN HEAD PHILLIPS SHEET METAL SCREW PACK OF 3 3 102 9121490
More informationParts Catalog EVM/EVM2/EVM3 REPAIR PARTS CATALOG NO. M50206(V)
EVM/EVM2/EVM3 REPAIR PARTS CATALOG NO. ISSUED APRIL 2016 ORDERS Please use Part Numbers when ordering and include the machine Serial Number (found on the electrical data plate) to insure that you will
More informationBruna Epdm Neopr Sizes: ½, ¾, 1, 1 ¼, 1 ½, 2, 2 ½, 3, 4, 5, 6 Full Teflon Viton CAM ARMS - PINS RINGS FOR CAMLOCKS
Bestline Mining Supplies Ltd, are appointed distributors of superior AIRLINE COUPLINGS HOSE CLAMPS HOSE AND PIPE FITTINGS. We work closely with our manufacturers in South Africa to bring you the best quality
More informationTECHNICAL DATA SHEET
ITEM: Eurocoup flexible couplings, flange adapters and dismantling joints PN6. Place of Manufacturer: Rozenobel 15 City Country Sizes: DN 50 - mm. 6 Bar Flangeadapterbody: Flangeadapterbody: PAS 30 Follower
More informationSIZE RANGE: 1 TO 10. PRESSURE RANGE: FULL VACUUM TO 275 psi
2 3 4 5 HANDLE OPTION ITEM DESCRIPTION STANDARD MATERIAL 1 Wrench - Locking Durcor -62 2 Hex Head Cap Screw 316 Stainless Steel 3 Washer 18-8 Stainless Steel 4 Wrench Stop Plate - Locking 304 Stainless
More informationNORMACLAMP Hose Clamps
NORMACLAMP NORMACLAMP NORMACLAMP S/SP Sealing clamps (NORMACLAMP S) to DIN 3017, Retaining clamps (NORMACLAMP SP) to DIN 3016 Thanks to their robust clamping brackets with metric bolts the clamping force
More informationDual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series
Dual Modular Safety Shutoff Valves with Proof of Closure Option DMV eco Series DMV-D eco Series DMV-DLE eco Series Two normally closed safety shutoff valves in one housing; each with the following approvals.
More informationParts Catalog. S-Series Slicer Manual S13. Model:
, 08 99506 ECN 035 Parts Catalog S-Series Slicer Manual Model: S3 S3 /3/08 Rev. M IMPORTANT! TO EXPEDITE SHIPMENT OF PARTS, ALWAYS SPECIFY MODEL, REV, PART NUMBER, AND SERIAL NUMBER OF UNIT. GLOBE FOOD
More informationData Sheet for Precision Potentiometer
The ALI(R)17/19 potentiometers in mm housing are suitable for applications where a precise multiturn potentiometer increased radial shaft loads is important. ALI(R)17/19 reinforced bearing ALI(R)17/19
More informationEclipse Hermetic Gas Boosters Series HB
Datasheet 620 7/6/2012 Eclipse Hermetic Gas Boosters Series HB Version 1.1 Type Designations The booster is identified by catalog model, assembly number, and ordering part number. The catalog model number
More informationELECTRA MAGIC RV and Marine Recirculating Toilets
ELECTRA MAGIC RV and Marine Recirculating Toilets Because We Take Your Leisure Seriously Electrical Hookup RV and Marine Models Connect your 12-Volt or 24-Volt model Electra Magic directly to the appropriate
More informationFlange. Connection Trunnion Ball Valves.
Flange Connection Trunnion Ball Valves www.smstork.com TRUNNION BALL VALVES Where to use On/Off Shore Oil and Gas Production Subsea Oil and Gas Production Oil and Gas Storage Oil and Gas Transportation
More informationAirfield Lighting. 12" Bidirectional High/Medium-Intensity Inset Light (INL-RN) Product Description
Product Description 12" Bidirectional High/Medium-Intensity Inset Light (INL-RN) Runway Threshold Runway End Approach (medium-intensity) Note: This page is blank for convenient double-sided printing. Safegate
More informationPARTS BOOK CATALOG SIDE HD FLAIL HEADS TRACTOR MID-MOUNT
PARTS BOOK CATALOG SIDE HD FLAIL HEADS TRACTOR MID-MOUNT DIAMOND MOWERS, Inc. 350 E 60 th St. North Sioux Falls, SD 57104 FOR WARRANTY CALL DIAMOND MOWERS DIRECT: 888-960-0364 OUR TECHNICIANS WILL DIAGNOSE
More informationPOSEIDON 4. Part List US-English
POSEIDON 4 Model: POSEIDON 4-18 POSEIDON 4-25 POSEIDON 4-28 POSEIDON 4-29 POSEIDON 4-30 POSEIDON 4-36 POSEIDON 4-36 POSEIDON 4-41 Part List US-English Table of Contents POSEIDON 4 Motor 3 Motor - suspension
More informationSUBMITTAL PACKAGE FLEXIBLE SPRINKLER DROP
SUBMITTAL PACKAGE FLEXIBLE SPRINKLER DROP BRAIDED CONNECTIONS...pg 2-6 UNBRAIDED CONNECTIONS...pg 7-9 INSTALLATION...pg 10 ACCESSORIES...pg 11 6/26/2018 BRAIDED CONNECTIONS ARGCO Flexible Sprinkler Drops
More informationAvailable materials: Stainless steel AISI 304 (Application in wet areas). Stainless steel AISI 316 (Application in aggressive areas).
Manual hose reel type STKi2 The manual hose reel type STKi2 with closed hub is suitable for all industrial and vehicle applications. While extending the drum hub and the cross braces the length of the
More informationSUB-STRUCTURES. SUB - STRUCTURES III Page 1 of 28. Overhead Electric Distribution Standards INTRODUCTION
SUB-STRUCTURES INTRODUCTION 1. This section is comprised of insulator and shield plates that are the building blocks to all of the vertical primary plates and parts of others. Plates not including required
More informationContents. Introduction...3 Description...3. Pack Contents...4. Rada Heavy Duty EV Shower Fittings Right Angled Connector (RAC)...
SHOWER FITTINGS PRODUCT MANUAL IMPORTANT Installer: This manual is the property of the customer and must be retained with the product for maintenance and operational purposes. Contents Introduction...3
More informationModel Number Structure
Solid State Relays Refer to Safety Precautions for All Solid State Relays. Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via
More informationParts Catalog T7/T71/T73 M40000/M40001/M40003
T7/T71/T73 M40000/M40001/M40003 REPAIR PARTS CATALOG NO. For machines starting with Serial No. T10001 ISSUED August 2010 ORDERS Please use Part Numbers when ordering and include the machine Serial Number
More informationGlass Door Fittings Glass Door Accessories
Angled striking plate Aluminium stainless steel coloured 981.27.983 Recess striking plate DIN left DIN right Steel nickel plated matt 911.39.285 911.39.28 WC thumbturn cylinder Area of application: For
More informationPilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)
(general purpose valve) ADK11/ADK12 Series NC (normally closed) type, NO (normally open) type Port size: Rc1/4 to Rc1 Diaphragm structure Excluding ADK12 JIS symbol ADK11: NC (normally closed) type OUT
More informationSection 11 Workstation Components
1 Section Quick and easy access to parts is made possible by the wide variety of trays, bins, and framing components available from Bosch. Individual workstation grab trays, containers, and ledges place
More informationWRANGLER 1710AB, 2010AB
WRANGLER 1710AB, 2010AB WIRING DIAGRAM ITEM PART NO. DESCRIPTION QTY 1 1393251 WIRE ASSEMBLY - CIRCUIT BREAKER TO BRUSH SWITCH 1 2 1393261 WIRE ASSEMBLY - CIRCUIT BREAKER TO VACUUM SWITCH 1 3 1393271 WIRE
More information2M Hermetic General Information. Why 2M Hermetic? GHEC 81. Amphenol s 2M Micro38999 Connector Series The New Aerospace Standard. Page Guide.
2M General Information Amphenol s 2M Micro38999 Connector Series The New Aerospace Standard Averaging less than half the size and weight of their 38999 ancestors, Amphenol s 2M Micro38999 series are an
More informationMahavir Enterprises.
+91-8071801335 Mahavir Enterprises https://www.indiamart.com/mahavir-ent/ We are a distinguished manufacturer and supplier of an immaculate array of Electrical,Rubber, PVC and Industrial Products. Our
More informationParts Catalog T7/T71/T73 M40000/M40001/M40003
T7/T71/T73 M40000/M40001/M40003 REPAIR PARTS CATALOG NO. M30202(R) For Machines with Serial No. T6183-T9031 ISSUED July 2009 ORDERS Please use Part Numbers when ordering and include the the machine Serial
More informationInstallation Instructions for Wall Mount, Deck Mount and Pre-rinse Faucets
Installation Instructions for Wall Mount, Deck Mount and Pre-rinse Faucets SAVE FOR END USER ELKAY 2222 CAMDEN COURT OAK BROOK, IL 60523 USA WALL MOUNT ASSEMBLY General Instructions Turn off the water
More informationTuf-Lite and Tuf-Lite II Fans 6000M Series Hub
Tuf-Lite and Tuf-Lite II Fans 6000M Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 32.8 or 10 Meter Diameter Hudson Tuf-Lite and Tuf-Lite II fan blades Hudson Tuf-Lite (black) fan blades
More informationSTIH) Technical Information Cut-off machine STIHL Cutquik TS 410, 420 Series Guard with defined adjustment range
STIH) Technical Information 5.009 Cut-off machine STIHL Cutquik TS 40, 40 Series 48 Contents. Guard with defined adjustment range. Belt guard, screw. Set of instruction labels 4. Summary. Guard with defined
More informationParts Catalog Issued: Jul 22, ICCI IH820 Series
Parts Catalog Issued: Jul, 04 ICCI IH80 Series Parts Catalog Usage Guide The information contained in this document is subject to change without notice. This catalog contains service parts for. If you
More informationAirfield Lighting. 12" Unidirectional High/Medium-Intensity Inset Light (INL-AP) Product Description
Product Description 12" Unidirectional High/Medium-Intensity Inset Light (INL-AP) Runway Threshold Wing Bars Runway End Approach - Centre Line - Crossbars - Side Row Barrettes Note: This page is blank
More informationSafety Interlock Switches
r Safety Interlock Switches TL19 TL19 Safety Interlock Switch with uard Door Locking High locking force of 10 N (270 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure enables
More informationRTA flexible conduits
[ PROTETION OF LES ] Products and systems RT flexible conduits For each application and environmental stress there is a corresponding polyamide, PV or metal-plastic flexible conduit solution, ideal for
More informationPARTS LIST COLT COLT HEPA
PARTS LIST COLT 800-1250 - 1450 COLT HEPA - 1250-1450 MOTOR / LID ITEM PART NO. PART DESCRIPTION QTY. 101 0891201 TOP COVER 1 102 0294341 TOP MOTOR SEAL 1 103 0299861 STRAIN RELIEF CORD CLAMP 1 104 0891131
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS C24DA/GA-SERIES STEAMERS C24GA6 C24GA10 C24DA6 C24DA10 ML-138085 ML-138088 ML-152022 ML-152023 VULCAN-HART DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC 3600 NORTH POINT BLVD.,
More informationHydraclaw Jacks. *dimensions are in mm. Powerful: 5 tonne capacity on head or toe. High Lift: 178mm. Fast Operation: 5.5mm lift per stroke
Hydraclaw Jacks Powerful: 5 tonne capacity on head or toe High Lift: 178mm Fast Operation: 5.5mm lift per stroke Stable: Substantial base offers stability under load Versatile: Horizontal or vertical operation
More informationData Sheet for Precision Potentiometer
AL(R)17/19 soldering lugs The AL(R)17/19 potentiometers in 22 mm housing are suitable for applications where a precise and economical multiturn potentiometer is important. Economical and precise multiturn
More informationAISI 316L PERFORMANCE RANGE INSTALLATION AND USE
CP-ST Stainless steel centrifugal pumps CP-ST4 Pump body: stainless steel AISI 304 Impeller: stainless steel AISI 304 Shaft: stainless steel AISI 431 CP-ST6 Pump body: stainless steel AISI 316L Impeller:
More informationMK3000. Operating and Calibration Instructions
MK3000 Operating and Calibration Instructions CONTENT 1. INTRODUCTION 3 1.1. GENERAL INFORMATION. 3 1.2. WORKING PRINCIPLE. 3 1.3. SECTION THROUGH CUTTER.. 4 1.4. SPECIFICATIONS.. 5 2. INSTRUCTIONS FOR
More informationTB131. Gas Conversion Kits for NVx & VPC Heaters. Issue 1.0 May Applies to models: NVx & VPC
TB131 Issue 1.0 May 2018 Applies to models: NVx & VPC Gas Conversion Kits for NVx & VPC Heaters www.powmatic.co.uk +44 (0) 1460 53535 info@powrmatic.co.uk General Information Heater conversion between
More informationBR-2250/BR Burnisher. Operator and Parts Manual. Model No.: BR BR-2250 Can. Pac BR BR-2500 Can.
BR-220/BR-200 Burnisher Model No.: 608342 BR-220 609248 BR-220 Can. Pac 608340 BR-200 609247 BR-200 Can. Pac Operator and Parts Manual NOBLES 1287 RANSOM STREET HOLLAND MI 49424 U.S.A. CUSTOMER SERVICE:
More informationCassette-folding arm-awning markilux 990
Cassette-folding arm-awning markilux 990 Mounting instructions 1. Overview 1 Projection profile 2 Folding arm 3 Fabric 4 Console 5 Cassette 6 Covering cap 7 Wall bracket 2. Mounting brackets 2.1 Overview
More informationINSTALLATION GUIDELINES
IMPORTANT: To ensure this product is installed properly, you must read and follow these guidelines. The owner/user of this product must keep this information for future reference. This product must be
More informationUser Manual for Separera 40
User Manual for Separera 40 User Manual for Separera 40 Congratulations on your purchase of a Separera 40. Before installing your new Separera 40, we recommend that you read through this instruction in
More informationManual Actuator. CR / CM Levers. Type Series Booklet
Manual Actuator CR / CM Type Series Booklet Legal information/copyright Type Series Booklet CR / CM All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited
More informationTerminals & Connectors
Your Connection Since 1970 Terminals & Connectors 2 TABLE OF CONTENTS Adapters........................... 13 Brazed Barrel Lugs................... 16-17 Bullet Connectors....................9-10 Butt Connectors.......................3
More informationType Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder
A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with
More informationEC BRUSHLESS MOTOR APPLICATIONS
APPLICATIONS Due to their high efficiency are often used into applications that requires low power consumption combined to high performance. Many versions are available to meet various application requirements:
More informationIntroduction 2. Other Applicable Documents 2. Scope of Delivery 3. Attaching the Snap-on Ferrite Suppressor 4
H-206.F2 6-Axis Precision Alignment System Contents Introduction 2 Other Applicable Documents 2 Scope of Delivery 3 Attaching the Snap-on Ferrite Suppressor 4 Connecting the Hexapod to the C-887 with the
More informationDJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing
Pushbuttons toggle switch 6,35 mm dia. toggle switch 6,35 mm dia. no. of poles material of contacts Switching position connection method colour part no. 2 silver 2 (maintained chromiumplated 02.17312.21
More informationWARNING DEVICES ATEX. V.le Rimembranze, Sesto S. G. (MI) ITALY Ph.: a.r. Fax:
WARNING DEVICES G1 : EExd IIB ROTARY SYREN MCL - MCL/S G2 : EExd IIB ELECTRIC HORN ETH G3 : EExd IIC DOUBLE TONE ACOUSTIC WARNING SACK G4 : EExd IIC FLASHING BEACON EVC/F G5 : EEx de IIC FLASHING VISUAL
More informationCEELOK FAS-T CONNECTORS
CEELOK FAS-T CONNECTORS Small Form Factor, Field Terminable Connectors CeeLok FAS-T connectors ofer a small form factor, ield terminable I/O connector capable of 0 Gb/s Ethernet. Crimpsnap contacts enable
More informationIB 7/40 Classic. Automatic residual ice discharge. Outstanding mobility. Efficient airflow in the device. Clear display
IB 7/40 Classic Thanks to airflow optimisations, our Ice Blaster IB 7/40 impresses with excellent results during dry ice cleaning, even when working with low air pressures. Compact device. 1 Automatic
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches TL4024 Safety Interlock Switch with uard Door Locking High locking force of 1,500 N (7 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure withstands
More informationConservatory awning W8 Description
1 3 4 Application Large-area external sun shading system for shading glazed conservatories, patio roofs and pergolas with flat pitch roofs. Function principle: tensioning system via toothed belt with steel
More informationFastLine. Contents. FastLine Description... 14/2 Ordering Details... 14/3 Technical Data... 14/7 14/1 1SBC R1001
14 Contents FastLine Description... 14/2 Ordering Details... 14/3 Technical Data... 14/7 14/1 Description FS / FST : IP 20 Busbar - assembly plate system FS : 400-1200 A Width : 150-1000 mm FST : 1200-2500
More information