Fiber attachment (E39-F9) 1.4 dia. 1 dia. (2) E32-TC200B dia. 1.2 dia max. Optical fiber, 2.2 dia Fiber attachment (E39-F9) 0.5 dia.

Size: px
Start display at page:

Download "Fiber attachment (E39-F9) 1.4 dia. 1 dia. (2) E32-TC200B dia. 1.2 dia max. Optical fiber, 2.2 dia Fiber attachment (E39-F9) 0.5 dia."

Transcription

1 s Through-beam (Sold in Pairs) E2-TL (T = 2.) M2.6 x (for M) 1. dia. 0.5 (nickelplated brass) M x Optical fiber, 2.2 dia. 0. E2-T12L 1. dia. 2. dia. (nickel-plated brass) dia. Optical fiber, 2.2 dia..2 (1) (1) E2-T21L 0.9 dia. M x 0.5 (nickel-plated brass) Optical fiber, 1 dia. Fiber attachment (E9-F9) E2-T22L 0.9 dia. 1.8 dia., 2 dia. (stainless) Heat-shrinkable tubing Optical fiber, 1 dia. Fiber attachment (E9-F9) 2.5 E2-TC0.2 E2-T dia. (1.) 1.0 dia. M2.6 x 0.5 SUS0 1.8 M x 0. (nickel-plated brass) Heat-shrinkable tubing Optical fiber, 1. dia. 1 dia. (2) E2-TC0B E2-TC0B Optical fiber, 2.2 dia..2 Fiber attachment (E9-F9) 1.0 dia. 1.2 dia max. E2-TC0E 0.5 dia Stainless tube (SUS0) (0) (see note) M x 0. (nickel-plated brass) 2. The value in the parentheses is for the E2-TC0B. M x 0.5 (nickel-plated brass) Optical fiber, 1 dia. Optical fiber, 2.2 dia. Fiber attachment (E9-F9) 2 dia E2-TC0F E2-TC0F Stainless tube (SUS0) 0.5 dia. 0.9 dia. min. M x 0.5 (nickel-plated brass) Optical fiber, 1 dia. Fiber attachment (E9-F9) 2.5 E2-TC0A 1.0 dia. 2.6 dia (0) (see note) M x 0.5 (nickel-plated brass) E2-T Sensing head (nickelplated brass) Sixteen, M x dia. M2.6 x 0.5 The value in the parentheses is for the E2-TC0F. Protective tube Optical fiber, 2.2 dia. (1.5) dia. Optical fiber, 2.2 dia.. 2. (1) 15

2 E2-T21 (nickel-plated brass) M x 0.5 Four, 0. dia. Protective tube Optical fiber, 1 dia. Fiber attachment (E9-F9) E2-TC0C dia. M2.6 x 0.5 Mx0. (nickelplated brass) (5) 22 dia. 2. Optical fiber, 2.2 dia. E2-TC0D E2-TC0D E2-T1L Stainless 1.0 dia. tube M x (SUS0) 0. (nickel-plated 1.2 brass) dia. max Optical fiber, 2.2 dia (0) (see note) 5, dia. (stainless) (when straight) (5) (when straight) Heat-shrinking tubing Optical fiber, 2.2 dia. 22 dia. The value in the parentheses is for the E2-TC0D. 2.8 dia Sensing surface E2-T2 1 dia. SUS0 2 dia. 1. dia. 5 Protective tube Optical fiber, 1 dia. Fiber attachment (E9-F9) E2-T1 Lens unit (PMMA). dia. 8.2 Heat resistive ABS Nitrile rubber E2-T1L (ABS) M1 x 1 -mm-dia. lens (PMMA) Optical fiber, 2.2 dia. R.5 Optical axis Two,.2 dia. Optical fiber, 2.2 dia ± ,000 E2-T12F -mmdia. lens, 5 dia. Fluoride resin dia. Optical fiber, 2.2 dia. 0 26

3 E2-T1F -mmdia. lens, 5 dia. Fluoride resin dia. Optical fiber, 2.2 dia. E2-T16 Optical axis (R) Mounting Holes 0.5-mm Wide Silt Seal (Sold in Pairs) Sensing head (ABS) (R) Two, M 2 (R) Black dia. Lens (2 x ) (PMMA).2 58 Two,.2 dia. 1-mm Wide Silt Seal (Sold in Pairs) 6 1 Mounting bracket E9-L 15 2 Black Fiber 2.2 dia. E2-T16P Two,.2 dia., 6-dia. counter sinking mm-wide Slit Seal (Sold in Pairs) E2-T16P with E9-L9 (Order Separately) Mounting 19 2 (2 x ) (PMMA) Two, M (heat-resistive ABS) Black mm-wide Slit Seal (Sold in Pairs). 1 Sensing head 19 Optical fiber 2.2-dia Black 2.2-dia. fiber E9-L9 Mounting Bracket 2.2 2

4 E2-M21 M x 0.5 (SUS0) Silicone tube Plastic fibers, four, 1 dia. One set of silicone tubes is black while the other set is grey for easy identification when they are connected to the emitter and receiver. Sleeve E2-T dia dia. 1 M x 0. (nickel-plated brass) Optical fiber, 2.2 dia. Resistant temperature is 150 C. Resistant temperature is 10 C when used continuously. E2-T5 Sensing surface dia. Resistant temperature is 150 C. Resistant temperature is 10 C when used continuously. 2 dia. (stainless) Optical fiber, 2.2 dia. E2-T dia. M2.6 x 0.5 SUS flexible tube Hexagon clamping screw M x dia. dia. 5 dia. Sleeve (SUS0) 2. dia. A 5 28 B (See note) 1 Section A resists 00 C and section B (which is inserted to the Amplifier) resists 1 C. The operating temperature of section B must also be within the withstand temperature range of the Amplifier. E2-T8S (standard length) (See note) dia. dia. 2.9-dia flexible tube (stainless) dia. 5 dia. Sleeve.5 dia. (stainless) dia. Lens (2 dia.) Section A resists 0 C and section B (which is inserted to the Amplifier) resists 1 C. The operating temperature of section B must also be within the withstand temperature range of the Amplifier. 28

5 Reflective E2-DL Two, 1. dia. dia. (nickel-plated brass) M6 x 0.5 Two optical fiber,2.2 dia E2-D12 dia (standard length) Two, 1 dia. (stainless) Heat-shrinkable tubing Optical fibers, two, 2.2 dia. E2-D21L Two, 0.9 dia. M x 0. (nickel-plated brass) Optical fiber, two, 1 dia. Two fiber attachments (E9-F9) E2-D22L Two, 0.9 dia. 2. dia. dia. (nickel-plated brass) Optical fiber, two, 1 dia. Two fiber attachments (E9-F9) 15 E2-DC0 Two, 1.0 dia. dia. M6 x 0.5 (ADC) Optical fiber,2.2 dia. E2-DC0B E2-DC0B.8 Two, 1.0 dia dia. max. Stainless tube (SUS0) (0) (see note) 2. 1 M6 x 0.5 (nickel-plated brass) Optical fiber,2.2 dia. The value in the parentheses is for the E2-DC0B. E2-DC0E Two, 0.5 dia. M x 0.5 (SUS0) Optical fiber, two, 1 dia. Two fiber attachments (E9-F9)

6 E2-DC0F E2-DC0F Stainless tube Two, 0.5 dia. (SUS0) 1.2 dia. max. M x 0.5 (SUS0) Optical fiber, two, 1 dia. Fiber attachment (E9-F9) (0) (see note) The value in the parentheses is for the E2-TC0F. E2-D Sixteen, dia. (SUS0) M6 X 0.5 Protective tube Optical fiber, two, 2.2 dia E2-D21 (nickel-plated brass) M x 0.5 Four, 0. dia. Protective tube Optical fiber, two, 1 dia. Fiber attachment (E9-F9) E2-DC0C Two, 1.0 dia. M6 x 0.5 (nickelplated brass) (150) 22 dia Optical fiber, two, 2.2 dia. 90 (when straight) 00 E2-DC0D E2-DC0D The value in the (150) parentheses is for Stainless Two, 1.0 dia. tube the E2-DC0D. 2.5 dia. max. (SUS0) M6 x 0.5 (nickel-plated brass) 22 dia (0) (see note) Optical fiber, two, 2.2 dia. 90 (when straight) 00 E2-DC9G E2-DC9G 1.2 dia. max. Stainless tube Sleeve 8 15 Do not bent the stainless tube in this range (0) 1 1 (see note) The value in the parentheses is for the E2-DC9G. 0

7 E2-D Two, 0. dia. (SUS0) 0.8 dia. dia. Heat-shrinkable tubing Optical fiber, two, 1 dia. Fiber attachment (E9-F9) E2-CC0 Sixteen, 0. dia. for light reception 1.0 dia. for light emission 2.5 dia. M6 x 0.5 Optical fiber, two, 2.2 dia. (nickel-plated brass) The fiber for the emitter is identified by a white line. E2-D2 Light emission fiber (0.5 dia.) (SUS0) Optical fibers, two, 1 dia. 2 dia. dia. Heat-shrinkable tubing Two fiber attachments (E9-F9) Light reception fiber (four, 0. dia.) E2-D2L Light emission fiber (1 dia.) The fiber for the emitter is identified by a white line. (standard length) ,50 Light reception fiber (sixteen, dia.), dia. (stainless) Branching box, 6 dia. (heat-resistive ABS black resin) Optical fibers, two, 2.2 dia. The fiber for the emitter is identified by a yellow dotted line. E2-D1L (stainless) 5 Heat-shrinkable tubing Optical fiber, two, 2.2 dia dia Light baffle E2-D2 Sensing surface (SUS0) 2 dia. dia. Heat-shrinkable tubing Optical fibers, two, 1 dia. 5 Two fiber attachments (E9-F9) Light baffle Sensing surface 1

8 E2-D12F, 6 dia. Fluoride resin 5 dia. Optical fiber, two, 2.2 dia E2-D51.1 Two, 1.5 dia..9,m6 x 0.5* Optical fiber, two, 2.2 dia. *nickel-plated brass Resistant temperature is 150 C. Resistant temperature is 10 C when used continuously. E2-D61 1. dia. M x 0. (SUS0) M6 x dia..5 dia. SUS flexible tube Hexagon clamping screw SUS0 Sleeve A (see note) B Section A resists 00 C and section B (which is inserted to the Amplifier) resists 1 C. The operating temperature of section B must also be within the withstand temperature range of the Amplifier. E2-D 1.0 dia. 1. dia. 2.5 dia dia. M x 0. (SUS0) SUS flexible tube dia. 2.8 dia. SUS0 Hexagon clamping screw 5 dia. Sleeve (see note) A B C 6. E2-R21 (One Unit supplied for the E9-R Reflector) Lens (PMMA) Section A resists 00 C, section B resists 00 C, and section C (which is inserted to the Amplifier) resists 1 C. The operating temperature of section C must also be within the withstand temperature range of the Amplifier. (ABS) 5 dia. Two washers Silicone tube M6 x 0.5 Optical fibers, two, 1 dia. Two fiber attachments (E9-F9)

9 E2-R16 (One Unit supplied for the E9-R1 Reflector) Nameplate (6) (ABS) Lens (PMMA) ±0.2 Optical fiber, two, 2.2 dia. Standard length: 2 m Two, M screws (attachment) Mounting bracket (attachment) E2-L E2-LA 5 Sensing distance Sensing distance White line Optical fiber, two, 2.2 dia. (ABS) Two,.2 dia., 6 dia. spot facing Two,.2 dia., 6 dia. spot facing White line (ABS) The fiber for the emitter is identified by a white line. Optical fiber, two, 2.2 dia. E2-LL Lens, two,.2 dia. 18 Sensing distance Two fiber attachment (E9-F9) Optical fiber two, 1-dia. (PC) 6 dia. counter sinking E2-L2L Lens, two,.2 dia. 18 Side view prism (PC) Two fiber attachment (E9-F9) Optical axis Optical fiber two, 1-dia. (PC) 6 dia. counter sinking

10 Fine Through-beam E2-T22S 1. dia. (nickel-plated brass) Optical fiber 2.2-dia. dia E2-T2S (nickel-plated brass) Optical fiber 2.2 dia..5 dia Mounting bracket (attachment) 2 dia. 2 Sensing surface Slot Sensor E2-G1 (ABS) R1.6 R1.6 Mounting Holes Two, M R.5 2 Optical axis Lens (PMMA) Optical fiber, two, 2.2 dia.. Reflector Reflector (Miniature) E9-R Reflector E9-R1 Adhesive tape Two,.5 dia Mounting bracket is attached Two, M

11 Attachments E9-F1 Long-distance Lens Unit dia. M2.6 x 0.5 Effective depth:.8 Spot facing depth: 0.9 E9-F2 Side-view Unit dia. 2.8 dia M2.6 Effective depth:.2 Spot facing depth: 0.9 E9-F Lens-equipped Reflective Unit Two, dia. M toothed washers Two,.2 0 dia. Two, M x Slotted head machine screw 12 E9-F5 Side-view Reflective Unit One set includes two units E9-FA Small Spot Lens Unit 6. 8± M x 6 Angle fixing screw Sensing hole Two,.2 dia ± Two,.2 dia. Mounting hole Two, M mounting holes (E2-TC0A) dia. dia. Lens (. dia.) 2 1 M2 x dia. When mounting, remove all of the accompanying screws first and then screw the E2-TC0A into the E9-F5 until the stopper comes into contact. Installation Connection Connection with SD2 Sensor Controller Blue Black Brown IN1 +12 V 0 V A maximum of two Sensors can be connected. Power supply voltage Output Functions Model 0 to 20 VAC Relay AND, OR SD2-AK AND, OR, and timer SD2-CK Flip-flop SD2-BK Transistor AND, OR, and timer SD2-CC Relay 2 inputs, 2 outputs, SD2-DK 2 inputs, 2 outputs, and timer SD2-EK 2 VDC AND, OR SD2-AKD AND, OR, and timer SD2-CKD 5

12 Precautions General Do not impose any voltage exceeding the rated voltage on the EX- NH. Do not impose 0 VAC or more on models that operate with DC. In both cases, the may be damaged. Do not short-circuit the load connected to the, otherwise the may be damaged. When supplying power to the, make sure that the polarity of the power is correct, otherwise the may be damaged. The load must be connected to the in operation, otherwise the may be damaged. Tightening Force The tightening force applied to the should be as follows: Screw-mounting Model Spring mounting clip Toothed washers Fiber Connection and Disconnection The Amplifier has a lock button. Connect or disconnect the fibers to or from the Amplifier using the following procedures: 1. Connection Lock button Nuts (attachment) Cylindrical Model Retaining screw (M max.) Clamping torque kgf cm max. s Clamping torque M/M screw 8 kgf cm max. (0.8 N m) M6 screw kgf cm max. (0.98 N m) 2-mm-dia. column kgf cm max. (0.29 N m) -mm-dia. column kgf cm max. (0.29 N m) E2-D1L kgf cm max. (0.98 N m) E2-T12F 8 kgf cm max. (0.8 N m) E2-D12F 8 kgf cm max. (0.8 N m) E2-T16 5 kgf cm max. (0.9 N m) E2-R21 6 kgf cm max. (0.59 N m) E2-M21 Up to 5 mm to the tip: 5 kgf cm max. (0.9 N m) Up to 5 mm from the tip: 8 kgf cm max. (0.8 N m) E2-LA 8 kgf cm max. (0.8 N m) E2-T16P kgf cm max. (0.29 N m) E2-T2S E2-L2L E2-LL Use a proper-sized spanner. Fiber Fiber insertion mark After cutting the fibers using the Fiber Cutter (E9-F), place an insertion mark on the fiber so that it can be properly inserted into the Amplifier. Insert the fiber into the Amplifier up to this insertion mark. 2. Disconnection Be sure to press the lock button again to unlock before pulling out the fiber, otherwise the fiber may be deteriorated.. The fiber must be locked or released in a temperature range of C to 0 C. Fiber Insertion If the portion from the tip to the insertion mark of the fibers are not inserted into the Amplifier Unit, the sensing distance will be reduced. 2.2-mm-dia. Fiber Insert to the portion from the tip to the insertion mark of each fiber into the Amplifier Unit. Thin Fiber with the E9-F9 Attachment The portion from the tip to the insertion mark of each fiber into the. Fiber with Fixed Length The portion from the tip to the insertion mark of each fiber into the mm 12.6 mm Amplifier Unit Amplifier Unit Amplifier Unit 12.6 mm 6

13 Cutting Fiber Insert a fiber into the Fiber Cutter and determine the length of the fiber to be cut. Press down the Fiber Cutter in a single stroke to cut the fiber. An insertion mark can be placed on the fiber to serve as a reference when inserting the fiber into the Amplifier. Use the following procedure. Insert the fiber all the way into the cutter and confirm that you can see it in the hole at the back of the cutter, then press firmly down on the cutter. (2) Connection Do not pull or press the s. The s have a withstand force of 1 kgf (9.8 N) or kgf (29. N) max. (pay utmost attention because the fibers are thin). Do not bend the s beyond the permissible bending radius. Do not bend the edge of the s. Correct Amplifier Unit mm min. (1) Incorrect mm min. Insert the fiber into the Amplifier up to the insertion mark. Proper fiber performance will not be achieved unless the fiber is inserted all the way to the insertion mark. (This method is applicable to standard, 2.2-mm-diameter fibers only.) dia. Insertion mark The cutting holes cannot be used twice. If the same hole is used twice, the cutting face of the fiber will be rough and the sensing distance will be reduced. Always use an unused hole. Use either one of the two holes on the right (refer to the following figure) to cut a thin fiber as follows: 1. An attachment is temporarily fitted to a thin fiber before shipment. Do not apply excess force on the s. Correct Incorrect Nylon wireholder Metal holder The Fiber Head could be break by excessive vibration. To prevent this, the following is effective: A one-turn loop can absorb vibrations. Tape Temporarily fitted 2. Secure the attachment after adjusting the position of it in the direction indicated by the arrow.. Insert the fiber into the E9-F to cut. Cutter E9-F Two holes for thin fiber Three holes for standard fiber (2.2-mm dia.). Finished state (proper cutting state) Approx. 0.5 mm Insert the fiber in the direction indicated by the arrow.

14 Bending Radius E9-F Sleeve Bender The bending radius of the stainless tube should be as large as possible. The smaller the bending radius becomes, the shorter the sensing distance will be. Insert the tip of the stainless sleeve to the Sleeve Bender and bend the stainless sleeve slowly along the curve of the Sleeve Bender (refer to the figure). R 12.5 R dia. 1.2 dia. max. 1. dia. max. min. R R 5 Fiber tip position mark Stainless tube 90 o max. Do not bend here. Amplifier Units Mounting Mounting 1. Mount the front part on the mounting bracket (attachment) or a DIN track. 2. Press the back part onto the mounting bracket or the DIN track. Do not mount the back part onto the mounting bracket or the DIN track first and then mount the front part on the mounting bracket or the DIN track, or the mounting strength of the Amplifier Unit may decrease. Dismounting By pressing the Amplifier Unit in direction () and lifting the fiber insertion part in direction as shown in the following, the Amplifier can be dismounted with ease. () DIN track () (1) DIN track (2) In the case of side mounting, attach the mounting bracket on the Amplifier first, and secure the Amplifier with M screws and washers. The diameter of the washers should be 6 mm max. Washers (6 dia. max.) 8

15 Turning the Power On After the is turned on, the will be ready to operate in 0 ms maximum. If power is supplied to the and the load is connected to the independently, be sure to turn on the power supply connected to the first. Mutual Interference Protection Function Perform two-point teaching if two to three s are closely mounted together, at which time supply power only to the Unit in teaching operation in turn or block the emitters of the s not in teaching operation. EEPROM Writing Error Write errors may result at the time of teaching due to power failure or static noise, in which case the Unit beeps and the operation indicators flash. If any of these occur, re-input teaching using the teaching button on the Amplifier. Minute Sensing Object This datasheet shows typical examples for detecting minute objects. These typical examples are for reference use only, because these example operations were tested on Units sampled at random from a lot and the values described are average values. Do not assume that all Units ensure such operations. Others When the power is off: The moment power is turned off, the may output a pulse signal which could affect the operation of the devices connected to it. This will occur more often if power is supplied to the from an external power supply, thus affecting the connected timer and counter. Use a built-in power supply as much as possible to avoid this. In a case where the cord is extended, use a wire with 0. mm 2 min. The total length of the cord should be 0 m max. Power supply: If a standard switching regulator is used as a power supply, the frame ground (FG) terminal and the ground (G) terminal must be grounded, or otherwise the can malfunction influenced by the switching noise of the power supply. The supplied voltage must be within the rated voltage range. Unregulated full- or half-wave rectifiers must not be used as power supplies. Do not lay wiring to the Optical Sensor together with power lines in the same piping or ducts. Doing so will cause induction between the lines, possibly resulting in faulty operation or destruction. Always lay wiring to the Optical Sensor in separate or dedicated piping. Power line Attachment Units Applications E9-F Fiber Connector Use the following procedure (refer to the figure) to connect fibers via the Fiber Connector. Protective Spiral Tube Insert a fiber to the Protective Spiral Tube from the head connector side (screwed) of the tube. Retention unit Splice Retention unit Protective spiral tube Push the fiber into the Protective Spiral Tube. The tube should be straight so that the fiber is not twisted when inserted. Then turn the end cap of the spiral tube. Each should be as close as possible before they are connected. Sensing distance will be reduced by approximately % when fibers are connected. Only fibers with a 2.2-mm dia. can be connected. (Refer to page NO TAG for applicable s.) Protective spiral tube Secure the Protective Spiral Tube on a suitable place with the attached nut. Mounting panel Hexagon clamping nut Protective spiral tube Toothed washer 9

16 Use the attached saddle to secure the end cap of the Protective Spiral Tube. To secure the Protective Spiral Tube at a position other than the end cap, apply tape to the tube so that the portion becomes thicker in diameter.! WARNING The is not a safety component for ensuring the safety of people as defined in EC Directive 91/68/EEC, or as covered by separate European standards or by any other regulations or standards. Saddle Tube End cap Reflector Observe the Following Precautions when Using the Reflector (E9-R) Use detergent, etc., to remove any dust or oil from the surfaces where tape is applied. Adhesive tape will not be attached properly if oil or dust remains on the surface. The E9-R cannot be used in places where it is exposed to oil or chemicals. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by To convert grams into ounces, multiply by Cat. No. E8-E1-2 OMRON Corporation Systems Components Division H.Q. 28th Fl., Crystal Tower Bldg , Shiromi, Chuo-ku, Osaka 50 Japan Phone: Fax: In the interest of product improvement, specifications are subject to change without notice. Printed in Japan 09-1M (029) a 0

1,100 (2,600) *1 M4 screw

1,100 (2,600) *1 M4 screw # / 9 / ± µ D DD Ω H H I µ 99 Ω I : High-resolution mode : Standard mode : Super-high-speed mode ; 1,0 (2,600) *1 M4 screw 870 (2,000) 350 (840) 1,0 870 3-mm dia. 350 340 M3 screw 260 0 2-mm dia. 0 340

More information

HPF Series. Fiber Units. Wide range of models for various applications and environments COMPATIBLE AMPLIFIERS HPX-AG HPX-ET HPX-T

HPF Series. Fiber Units. Wide range of models for various applications and environments COMPATIBLE AMPLIFIERS HPX-AG HPX-ET HPX-T Fiber Units HPF Series Wide range of models for various applications and environments COMPATIBLE AMPLIFIERS Type Catalog listing Appearance Digital fiber-optic sensors HPX-AG Gang-mounted distributed remote

More information

General-Use Auto-Tuning HPX-T Series

General-Use Auto-Tuning HPX-T Series General-Use Auto-Tuning HPX-T Series Built-in Hyper-tuning automatically adjusts scanning characteristics. Adjustment steps, results and scanning conditions are digitally displayed by LED. Digital display

More information

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops Power Relay A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated

More information

Choose the performance you need

Choose the performance you need Choose the performance you need General application STEP 1: The fiber optic sensor heads Standard cylindrical Square shape Long distance Enhanced environment resistance Chemical resistant Heat resistant

More information

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC Solid State Relays G3NE Compact, Low-cost, SSR Switching 5to20 A Wide load voltage range: 75 to 264 VAC. Dedicated, compact aluminum PCB and power elements used. Built-in varistor effectively absorbs external

More information

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B A High-capacity, High-dielectricstrength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated coil that handles

More information

Model Number Structure

Model Number Structure Solid State Relays Refer to Safety Precautions for All Solid State Relays. Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via

More information

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately) PCB Relay Small, Low-Cost 0-A Power Relay for PCB Applications Small, yet capable of switching up to a 0-A loads. Inexpensive. Ideal for home and industrial appliances, HVAC (heating, ventilating, and

More information

Primrose Awnings - Full Cassette Manual & Electric Instructions

Primrose Awnings - Full Cassette Manual & Electric Instructions Primrose Awnings - Full Cassette Manual & Electric Instructions Contents Warning 2.0m - 3.5m Awnings 8 x Expansion bolts ** 2 x brackets 1 x Awning 1 x Winder 4.0m - 5.0m Awnings 12 x Expansion bolts **

More information

Blue Series Hot Melt Hose with RediFlext II Hanger System

Blue Series Hot Melt Hose with RediFlext II Hanger System Instruction Sheet P/N 1124594_01 Blue Series Hot Melt Hose with RediFlext II Hanger System Safety WARNING! Allow only personnel with appropriate training and experience to operate or service the equipment.

More information

Slit Loom Installation Tool. Spools and Bags. Bulk Boxes

Slit Loom Installation Tool. Spools and Bags. Bulk Boxes Looms and Tubing Polyethylene Slit Loom Slit seam construction allows for easy wire insertion and repair, yet retains wire even when bent or twisted. Maximum temperature 93 C (200 F). Ideal for protecting

More information

Contents. Awnings USA - Full Protective Hood Manual Instructions ft 11" - 11ft 6" Awnings

Contents. Awnings USA - Full Protective Hood Manual Instructions ft 11 - 11ft 6 Awnings Awnings USA - Full Protective Hood Manual Instructions Contents Warning We recommend that two or more people are required to lift the awning into place. 4ft 11" - 11ft 6" Awnings 8 x Expansion bolts **

More information

Safety Interlock Switches

Safety Interlock Switches r Safety Interlock Switches TL19 TL19 Safety Interlock Switch with uard Door Locking High locking force of 10 N (270 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure enables

More information

Smallest Connector with Removable Contacts

Smallest Connector with Removable Contacts 1 Ultra-Miniature 8STA Size 01 Connectors Smallest Connector with Removable Contacts Ultra compact design and very lightweight connector dedicated to the harshest of motorsport environments. Innovative

More information

NEWMAR SERVICE SCHOOL

NEWMAR SERVICE SCHOOL NEWMAR SERVICE SCHOOL TRAINING INFORMATION GUIDELINE FOR FEBRUARY 2013 OUR PRODUCTS: NOVA DUAL PITCH AWNING G-2000/ G-1500 2 P a g e G-2085 G-5000 3 P a g e G-LINKS 4 P a g e NOVA/ G-2000/ G-1500 BASIC

More information

HPX Series. General-Use Potentiometer Tuning

HPX Series. General-Use Potentiometer Tuning General-Use Potentiometer Tuning HPX Series High Sensitivity over a Long Scanning Distance of 00mm (Thru Scan Model), Easy-to-Use Functions/Structure, and High Reliability. Quick response (µs) plus mark

More information

INSTRUCTION MANUAL ALEKO RETRACTABLE AWNING

INSTRUCTION MANUAL ALEKO RETRACTABLE AWNING INSTRUCTION MANUAL for ALEKO RETRACTABLE AWNING www.alekoproducts.com FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY! 1 Important Safety Precautions WARNING NOTE: FOR PERSONAL SAFETY,

More information

Plug-in/solder terminals with LED indicator

Plug-in/solder terminals with LED indicator General-purpose Relay LY Electromechanical Relays A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole

More information

E32 Series. Fiber Units Support an Increasing Range of Applications. Fiber Units. Features. Standard Models First, Our Standard Lineup Page 18

E32 Series. Fiber Units Support an Increasing Range of Applications. Fiber Units. Features. Standard Models First, Our Standard Lineup Page 18 Photoelectric Units Units Support an Increasing Range of s Standard Models Models available in a wide variety of shapes customization service for virtually any application Environment-resistive Models

More information

HPX-ET Series. Gang-Mounted Remote Cluster

HPX-ET Series. Gang-Mounted Remote Cluster Gang-Mounted Remote Cluster HPX-ET Series Connector connection type 16-unit gang-mounting sensors strongly support the request for wiring and space savings. Distributed remote cluster arrangement is a

More information

Wire and Cable Holders

Wire and Cable Holders WIRE MANAGEMENT Wire and able Holders For low cost wire management. The push-mount style comes in vertical orientation for top entry and narrow width, and horizontal orientation for side entry and low

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-5480 www.cmafh.com Safety Interlock Switches TL19 Safety Interlock Switch with uard Door Locking High

More information

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product 996A106032 TUM 1024 REV. E 06.02.14 Tranberg AS P.O. Box 8033 N-4068 Stavanger

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Safety Interlock Switches TL4024 Safety Interlock Switch with uard Door Locking High locking force of 1,500 N (7 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure withstands

More information

Cabinet Mount Assist Lift n Lock Instructions

Cabinet Mount Assist Lift n Lock Instructions Cabinet Mount Assist Lift n Lock Instructions PART LIST 2 @ Gas Cylinder 1 @ Lock Bar 2 @ Rubber Sleeve (preset) 4 @ Stopper Pin (2pcs preset) 4 @ Saddle Block 8 @ 19mm Black PVC Cap 5 @ 14mm Black PVC

More information

FIBER OPTIC CLOSURES

FIBER OPTIC CLOSURES FIBER OPTIC CLOSURES In-line type and dome type - series CLS-I, CLS- IF2X, CLS-D, CLS-DF2X144 and CLS-DF2X240 PACIFIC INTERCONNECTIONS - connecting the world with fiber optics IN-LINE TYPE FIBER OPTIC

More information

USER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999)

USER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999) USER MANUAL BMU WORKCAGE CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999) All persons operating this equipment must read and completely understand this manual. Any operation in violation

More information

Primrose Awnings Half Cassette Manual & Electric Instructions

Primrose Awnings Half Cassette Manual & Electric Instructions Primrose Awnings Half Cassette Manual & Electric Instructions Contents for 2.5m, 3m Awnings 4 x Expansion bolts (2 per bracket)** 2 x brackets 1 x Awning Contents for 3.5m, 4m Awnings 6 x Expansion bolts

More information

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand is a trademark of Skyline Exhibits Patent Pending 1.1 1. Banner Stand Setup 1.1 Remove banner stand from standard case or Arrive Portable Display & Workstation and assemble pole. 1.2 Insert pole into base

More information

2522 and 2523 Fiber Optic Splice Organizer Tray

2522 and 2523 Fiber Optic Splice Organizer Tray 2522 and 2523 Fiber Optic Splice Organizer Tray Instructions February 1996 Issue 1, 34-7039-6256-2 1 Table of Contents 1. General... 3 2. Kit Contents... 3 3. Available Kits and Accessories... 4 4. Tray

More information

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G)

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G) Part B, ection Model Voltage This section covers the following unit configurations. 3400V All Pump Piston Pump (E or G) Manifold Control 4-Port (A) Vista tandard (V) Vista Pattern (PC) Vista Temperature

More information

An Improved Pedestal To A Version One Worksurface

An Improved Pedestal To A Version One Worksurface Steelcase, Inc. Grand Rapids, MI 49501 U.S.A. 1-888-783-3522 An Improved Pedestal To A Version One Worksurface NOTE: This installation applies to 25, 30, and 35 deep worksurfaces with lock rail only. VERSION

More information

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction Emergency Stop Switch Install in 22-dia. or 25-dia. Panel Cutout Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1,. Safety Lock Mechanism prevents misuse.

More information

RTA flexible conduits

RTA flexible conduits [ PROTETION OF LES ] Products and systems RT flexible conduits For each application and environmental stress there is a corresponding polyamide, PV or metal-plastic flexible conduit solution, ideal for

More information

Glass Door Fittings Glass Door Accessories

Glass Door Fittings Glass Door Accessories Angled striking plate Aluminium stainless steel coloured 981.27.983 Recess striking plate DIN left DIN right Steel nickel plated matt 911.39.285 911.39.28 WC thumbturn cylinder Area of application: For

More information

Darkly LabsR AIR-ASSIST. Installation Manual. English. Deutsch. Emblaser 2 Air-Assist Installation Manual 1.3

Darkly LabsR AIR-ASSIST. Installation Manual. English. Deutsch. Emblaser 2 Air-Assist Installation Manual 1.3 Darkly LabsR AIR-ASSIST Installation Manual English Deutsch Emblaser 2 Air-Assist Installation Manual 1.3 1. WHATS IN THE BOX Air-Assist pump Nozzle Bracket Nozzle Air-Assist pump with bracket, Nozzle

More information

Please read this guide carefully. It tells you how to prepare your cutting plotter for production use in a few easy steps.

Please read this guide carefully. It tells you how to prepare your cutting plotter for production use in a few easy steps. OPERATING GUIDE for Secabo mini Cutting Plotter Congratulations on purchasing your Secabo mini cutting plotter! Please read this guide carefully. It tells you how to prepare your cutting plotter for production

More information

General-purpose Relay

General-purpose Relay General-purpose Relay A Miniature Power Relay Equipped with arc barrier. Withstand : 2,000 V. RC+Y LR Ordering Information Open Relays Type Contact form Plug-in/solder terminals Plug-in/solder terminals

More information

Installation and Maintenance Manual

Installation and Maintenance Manual Freestanding Gas Stove MODEL: PGS2005 GPEBB20R GPEBW20R Installation and Maintenance Manual Warning Maintenance products should be carried out by professional and technical personnel with relevant qualification,

More information

Lab Skills: Introduction to the Air Track

Lab Skills: Introduction to the Air Track Lab Skills: Introduction to the Air Track 1 What is an air track? An air track is an experimental apparatus that allows the study of motion with minimal interference by frictional forces. It consist of

More information

Otter Pro X-Over Lodge Installation and Set-Up Instructions

Otter Pro X-Over Lodge Installation and Set-Up Instructions Otter Pro X-Over Lodge Installation and Set-Up Instructions Otter Pro X-Over Lodge Fits Magnum Otter II & Pro Sled Only Parts Identification and Check List MODEL NUMBERS: Complete Pkg Pro X-Over Lodge

More information

Primrose Awnings Half Cassette Manual & Electric Instructions

Primrose Awnings Half Cassette Manual & Electric Instructions Primrose Awnings Half Cassette Manual & Electric Instructions Contents Contents for 2m, 2.5m, 3m Awnings 2 x wall brackets 4 x expansion bolts (2 per bracket)** 1 x Awning Contents for 3.5m, 4m and 4.5m

More information

INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL AWNINGS. For trailers & motor homes with straight sides TOOLS REQUIRED

INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL AWNINGS. For trailers & motor homes with straight sides TOOLS REQUIRED AWNINGS INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL For trailers & motor homes with straight sides TOOLS REQUIRED 1/4" electric drill Ratchet handle kit 3/8" & 7/16" socket No. 1 and No. 2 screwdriver

More information

OAsys OP0XX, Issue 01, February Outside Plant. Metallic joint closure NXOK 10 units. Features and Benefits

OAsys OP0XX, Issue 01, February Outside Plant. Metallic joint closure NXOK 10 units. Features and Benefits Metallic joint closure NXOK 10 units for OPGWs with steel tubes and for optical cables Prysmian Part Number: See the page no. 3 6 The NXOK 10 joint closure units are designed to be used for jointing optical

More information

Table Legs & Extensions 7.1

Table Legs & Extensions 7.1 .0 Table Legs & Extensions.1 Installation example: With end frame and bracket ( 633.13.200) With visible lifting column With concealed/invisible lifting column Installation example: With two brackets (

More information

Primrose Awnings Full Cassette Manual & Electric Instructions

Primrose Awnings Full Cassette Manual & Electric Instructions Primrose Awnings Full Cassette Manual & Electric Instructions Contents for Full Cassette Awning 1 x Remote control receiver box 2 x Remote hand-held zappers 1 x 5 metre cable 1 x Template sticker **The

More information

quick and easy installation guide

quick and easy installation guide www.directdriveopener.com quick and easy installation guide Back 2 Front. Motor Carriage 2. C-rail. Chain. Limit stops. Slide in part (tensioner) Rail assembly Insert C-rail parts () into the connecting

More information

READ ME FIRST! IMPORTANT WARNING! ENG. Roof top tent

READ ME FIRST! IMPORTANT WARNING! ENG. Roof top tent Roof top tent ENG TENT031 220 min READ ME FIRST! Thank you for purchasing a Front Runner Roof Top Tent. Before you start, take a moment to familiarize yourself with these Fitting Instructions and the components

More information

Optional Controls (Depends which set was purchased) Set A (Remote control kit)

Optional Controls (Depends which set was purchased) Set A (Remote control kit) Primrose Awnings - Half Cassette Manual & Electric Instructions Contents Warning 1.5m - 3.0m Awnings 4 x Expansion bolts (2 per bracket)** 2 x brackets 1 x Awning 1 x Winder handle 3.5m - 4.0m Awnings

More information

Data Sheet for Precision Potentiometer

Data Sheet for Precision Potentiometer The ALI(R)17/19 potentiometers in mm housing are suitable for applications where a precise multiturn potentiometer increased radial shaft loads is important. ALI(R)17/19 reinforced bearing ALI(R)17/19

More information

Data Sheet for Precision Potentiometer

Data Sheet for Precision Potentiometer AL(R)17/19 soldering lugs The AL(R)17/19 potentiometers in 22 mm housing are suitable for applications where a precise and economical multiturn potentiometer is important. Economical and precise multiturn

More information

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1 Parts B - Section B Parts. Introduction To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use the parts list, and the accompanying illustration, to describe

More information

Hose Reel Series L701/G701

Hose Reel Series L701/G701 Hose Reel Series L70/G70.0 WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal

More information

ipad mini 4 LTE Home Button Assembly Replacement

ipad mini 4 LTE Home Button Assembly Replacement ipad mini 4 LTE Home Button Assembly Replacement Replace the home button assembly in an ipad mini 4 LTE. Written By: Evan Noronha ifixit CC BY-NC-SA www.ifixit.com Page 1 of 25 INTRODUCTION Follow the

More information

Installation procedure for solenoid starter connector kit part no a

Installation procedure for solenoid starter connector kit part no a Date: 22/02/2018 Subject: Models: Installation procedure for solenoid starter connector kit part no.69928501a Multistrada 1200 Model Year 2015-2017 (all model and country versions) Multistrada 1200 Enduro

More information

Otter Pro XT Cabin Installation and Set-Up Instructions

Otter Pro XT Cabin Installation and Set-Up Instructions Otter Pro XT Cabin Installation and Set-Up Instructions Otter Pro XT Cabin Fits Medium Otter Pro and Otter II Sled Only Parts Identification and Check List MODEL NUMBERS: Complete Pkg Pro XT Thermal Cabin

More information

PL500A Platform Extension

PL500A Platform Extension PL500A Platform Extension Operator Manual Copyright 2009 ServerLift Corporation 821 N 2nd Street Phoenix, AZ 85004 VOICE: 602.254.1557 FAX: 602.412.4479 821 N 2nd Street Phoenix, AZ 85004 VOICE: 602.254.1557

More information

Primrose Awnings - Standard Manual Instructions

Primrose Awnings - Standard Manual Instructions Primrose Awnings - Standard Manual Instructions Contents Warning 1.5m - 3.0m Awnings 4 x Expansion bolts (2 per bracket)** 2 x brackets 1 x Awning 1 x Winder handle 3.5m - 4m Awnings 6 x Expansion bolts

More information

Optional Controls (Depends which set was purchased) Set A (Remote control kit)

Optional Controls (Depends which set was purchased) Set A (Remote control kit) Primrose Awnings - Full Cassette Manual & Electric Instructions Contents Warning 1.5m - 3.5m Awnings 8 x Expansion bolts ** 2 x brackets 1 x Awning 1 x Winder 4.0m - 5.0m Awnings 12 x Expansion bolts **

More information

CRD120SC TUBING CUTTER

CRD120SC TUBING CUTTER CRD120SC TUBING CUTTER OPERATIONS MANUAL 1 VERSION 2.1 LAST EDITED 05.01.2018 cleanroomdevices.com Table of Contents Table of Contents....2 1.0 General Product & Safety Information... 3 1.1 Product Information

More information

I- 39. Liquidtight Connectors and Hubs for Liquidtight Flexible Metal Conduit General Information and special features.

I- 39. Liquidtight Connectors and Hubs for Liquidtight Flexible Metal Conduit General Information and special features. Liquidtight Connectors and Hubs for Liquidtight Flexible Metal Conduit General nformation and special features. - 39 Seal out oil, water, dirt, dust and fumes wherever liquidtight flexible metal conduit

More information

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions Therme storage water heater Table of contents Symbols used... 8 Installation instructions Water supply... 9 Choice of location... 9 Installation of the Therme... 9 Fitting the draining and venting valve...

More information

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns: 7-1 Section 7 Using the Illustrated List The parts lists provided in this section are organized into the following columns: Item Identifies illustrated parts that are available from Nordson Corporation.

More information

NORMACLAMP Hose Clamps

NORMACLAMP Hose Clamps NORMACLAMP NORMACLAMP NORMACLAMP S/SP Sealing clamps (NORMACLAMP S) to DIN 3017, Retaining clamps (NORMACLAMP SP) to DIN 3016 Thanks to their robust clamping brackets with metric bolts the clamping force

More information

Color Light Streams Lighted Bubbler Spillway Pot (CLSDLP) Installation Manual

Color Light Streams Lighted Bubbler Spillway Pot (CLSDLP) Installation Manual Color Light Streams Lighted Bubbler Spillway Pot (CLSDLP) Installation Manual 27.75 23.75 25.50 20.75 Specifications: 8-13 GPM 12-14 VAC only (Class 2 transformer required) 3W max. 100 ft. cord, conduit

More information

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001 QUALITY MANAGEMENT SYSTEM CERTIFIED HEALTH & SAFETY MANAGEMENT SYSTEM Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING ISO 9001:2008 REGISTERED COMPANY EN ISO 10380 PRODUCED AND TESTED OHSAS 18001

More information

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with

More information

Gas Conversion Kits and Instructions

Gas Conversion Kits and Instructions Gas Conversion Kits and Instructions INSTALLATION FORM RGM 432/433-GC (Version D.1) Obsoletes Form RGM 432/433-GC (Version D) APPLIES TO: Model FT and Model SFT All gas conversion must be done by a qualified

More information

ELE-3COP-375 Title - Braid termination using a Band Strap Adaptor.

ELE-3COP-375 Title - Braid termination using a Band Strap Adaptor. Before starting work please read this document carefully and note the guidance given. 1 Purpose and Scope This COP describes the procedure to be used when carrying out the installation of a Band Strap

More information

Advantage Plus TIM-3600 Series Reel

Advantage Plus TIM-3600 Series Reel Read the following precautions and instructions before you begin assembly or using. Failure to comply with these instructions could result in personal injury or property damage. Keep these instructions

More information

BILLY GOAT KV HOSE KIT (P/N ) PURPOSE: To allow for vacuuming in hard to reach places.

BILLY GOAT KV HOSE KIT (P/N ) PURPOSE: To allow for vacuuming in hard to reach places. BILLY GOAT KV HOSE KIT (P/N 891125) PURPOSE: To allow for vacuuming in hard to reach places. Part No 891061-1 - Form No F052209A INSTALLATION: Step 1. Attach nozzle wear guards. 1. Disconnect spark plug

More information

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: Tavor 8-T Active Ceiling Speaker P/N: 2900-300343 Rev 4 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions

More information

Urea/Adblue Hose Reel

Urea/Adblue Hose Reel www.scintex.com.au sales@scintex.com.au Model: SHR3408 Urea/Adblue Hose Reel Product Manual Specifications Spring driven drum: for automatic rewind. Locking ratchet: to maintain the desired length of hose

More information

Colonial and Grand Colonial Fire Pit Tables. Installation Instructions for

Colonial and Grand Colonial Fire Pit Tables. Installation Instructions for Colonial and Grand Colonial Fire Pit Tables Installation Instructions for Colonial-48-M-K, Col-48-MNB-K, Grand-Colonial-48-K, CM-48-DIN-K, MNB-48-DIN-K, GC-48-DIN-K, CM-48-PUB-K, MNB-48-PUB-K, GC-48-PUB-K

More information

Reverse Osmosis system 50 GPD Instruction manual EN

Reverse Osmosis system 50 GPD Instruction manual EN Reverse Osmosis system 50 GPD Instruction manual EN Contents 1. Unpacking 2. Scope of supply 3. Insertion of the membranes 4. Connecting the lines 5. Installation 6. First commissioning 7. Consumables

More information

P3000 UNIVERSAL Clamp-On

P3000 UNIVERSAL Clamp-On IHI INSTRUCTION MANUAL Required Tools P3000 UNIVERSAL Clamp-On Wrench Allen Key P3001 65 ENDCAPS P3011 65 BLACK P300 7 ENDCAPS P301 7 WHITE P3003 ENDCAPS P3013 SILVER PART# DESCRIPTION ENDCAPS SIDE SUPPORTS

More information

Auxiliary 63.5l Fuel Tank Ford/Mazda Pick-up Truck 2012-Current READ ME! IMPORTANT WARNING!

Auxiliary 63.5l Fuel Tank Ford/Mazda Pick-up Truck 2012-Current READ ME! IMPORTANT WARNING! Auxiliary 63.5l Fuel Tank Ford/Mazda Pick-up Truck 2012-Current ENG FTFM006 90 min READ ME! Thank you for purchasing a Front Runner Ford/Mazda Pick-Up Truck 2012 - Current Fuel Tank. Before you start,

More information

AND LOAD CANOPY RACK SPECIFICATIONS

AND LOAD CANOPY RACK SPECIFICATIONS 8MAY15 INSTRUCTIONS for the LOCK AND LOAD CANOPY RACK SPECIFICATIONS and SAFE LOADING REQUIREMENTS The Lock and Load ladder carrier for Truck Caps is a rack designed to mount to the top of a pickup truck

More information

IMPORTANT OWNER-OPERATOR INSTALLATION INSTRUCTIONS. Part # A7006

IMPORTANT OWNER-OPERATOR INSTALLATION INSTRUCTIONS. Part # A7006 IMPORTANT OWNER-OPERATOR INSTALLATION INSTRUCTIONS Part # A7006 Parts List Wobble Stopper Body Wobble Stopper Shaft Camper Bracket Lower Bracket Assembly Upper Bracket Upper Bracket Clamp 3/8 SAE Flat

More information

BR-2250/BR Burnisher. Operator and Parts Manual. Model No.: BR BR-2250 Can. Pac BR BR-2500 Can.

BR-2250/BR Burnisher. Operator and Parts Manual. Model No.: BR BR-2250 Can. Pac BR BR-2500 Can. BR-220/BR-200 Burnisher Model No.: 608342 BR-220 609248 BR-220 Can. Pac 608340 BR-200 609247 BR-200 Can. Pac Operator and Parts Manual NOBLES 1287 RANSOM STREET HOLLAND MI 49424 U.S.A. CUSTOMER SERVICE:

More information

Swagelok Thermoplastic Hose Hand Swager User s Manual

Swagelok Thermoplastic Hose Hand Swager User s Manual Swagelok Thermoplastic Hose Hand Swager User s Manual Thermoplastic Hose Hand Swager User s Manual Contents Hand Swager Components....................... 2 Setup Swager.......................................

More information

Levels & Measuring Tools

Levels & Measuring Tools Levels & Measuring Tools Quick, easy and accurate measurements can mean the difference between a job well done and one that misses the mark. Klein offers a variety of levels and other measuring devices

More information

Roller Bar End Cap (w/round Drive Shaft) Replacement Instructions for Vista and Motorized Awnings * Helpers needed *

Roller Bar End Cap (w/round Drive Shaft) Replacement Instructions for Vista and Motorized Awnings * Helpers needed * RETRACTABLE AWNINGS For Technical Support visit us at www.sunsetter.com/ownerscorner or Call Toll Free 800-670-7071 Fax 877-224-4944 Roller Bar End Cap (w/round Drive Shaft) Replacement Instructions for

More information

Meat Slicer INSTRUCTION MANUAL CAUTION! ONE YEAR LIMITED WARRANTY

Meat Slicer INSTRUCTION MANUAL CAUTION! ONE YEAR LIMITED WARRANTY ONE YEAR LIMITED WARRANTY INSTRUCTION MANUAL The original registered owner of this product should contact SKYFOOD EQUIPMENT LLC at 305-868-16 for any warranty problems or service. SKYFOOD EQUIPMENT LLC

More information

Synflex. Mini Catalog

Synflex. Mini Catalog Synflex Mini Catalog Table of Contents Hose Selection Chart Core 5 Hoses (Application/Product) 2 3R30, 3130, 3580, 30CT, 3R80 Core 5 Hoses (Product) 2 3R30, 3130, 3580, 30CT, 3R80 Hose 3R30 Low Pressure

More information

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E The Trimfast Ream Cutters are reliable, high performance cutters that will give you the results you need quickly

More information

AXELENT WIRE TRAY Wire Trays, Fittings, Mountings and Accessories. Technical manual

AXELENT WIRE TRAY Wire Trays, Fittings, Mountings and Accessories. Technical manual AELENT WIRE TRAY Wire Trays, Fittings, Mountings and Accessories Technical manual ver. 02-2015 Article Page Article Page 1 Fitting 11 2 Fitting 11 3 Angled Fitting 11 4 Fitting 11 5 Joining Fitting 11

More information

Otter XT Cabin Installation and Set-Up Instructions

Otter XT Cabin Installation and Set-Up Instructions Otter XT Cabin Installation and Set-Up Instructions Otter XT Cabin Fits Medium Otter Wild Sled Only Parts Identification and Check List MODEL NUMBERS: Complete Pkg Otter XT Cabin 200962 2 1 PARTS LIST

More information

SPIRAL SLICER Instruction Manual Model #5280 & 5280M. Part No Revised Feb. 2010

SPIRAL SLICER Instruction Manual Model #5280 & 5280M. Part No Revised Feb. 2010 SPIRAL SLICER Instruction Manual Model #5280 & 5280M Part No. 82876 Revised Feb. 2010 SAFETY PRECAUTIONS INSTALLATION INSTRUCTIONS Inspection of Shipment: 5280 & 5280M SPIRAL SLICER Unpack all cartons

More information

HEATER POWER CONTROLLER

HEATER POWER CONTROLLER HEATER POWER CONTROLLER /04 Rev 0 - - ii PROCON MODEL HPC TABLE OF CONTENTS DESCRIPTION... MANUAL REVISIONS... 5 WARRANTY... 5 SPECIFICATIONS... 6 DRAWINGS PHYSICAL DIMENSIONS 44-090095-0-00... 7 PANEL

More information

Thomas Scientific Swedesboro, NJ U.S.A.

Thomas Scientific Swedesboro, NJ U.S.A. Thomas Scientific Swedesboro, NJ 08085-0099 U.S.A. Wiley Laboratory Mill, Model 4 3375-E10 (115 V, 50/60 HZ) USE AND CARE OF CATALOG NUMBER: 3375-E10 Wiley Laboratory Mill, Model 4 (115 V, 50/60 HZ) UNPACKING

More information

Tidland Series 'C' Knifeholder MAINTENANCE MANUAL Crush Cartridge Class I, II, III Crush Slitting

Tidland Series 'C' Knifeholder MAINTENANCE MANUAL Crush Cartridge Class I, II, III Crush Slitting Tidland Series 'C' Knifeholder MAINTENANCE MANUAL Crush Cartridge Class I, II, III Crush Slitting Please read and understand all the instructions before you start to maintain the Tidland Series 'C' Knifeholder.

More information

4A1-114/114KR & 4A1-2 MANUAL TENSIONERS

4A1-114/114KR & 4A1-2 MANUAL TENSIONERS M L. C O O N AL TO 4A1-114/114KR & 4A1-2 W W W.T R AD IT IO MANUAL TENSIONERS READ THESE INSTRUCTIONS CAREFULLY. FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SEVERE PERSONAL INJURY. GENERAL SAFETY

More information

Contents. Introduction...3 Description...3. Pack Contents...4. Rada Heavy Duty EV Shower Fittings Right Angled Connector (RAC)...

Contents. Introduction...3 Description...3. Pack Contents...4. Rada Heavy Duty EV Shower Fittings Right Angled Connector (RAC)... SHOWER FITTINGS PRODUCT MANUAL IMPORTANT Installer: This manual is the property of the customer and must be retained with the product for maintenance and operational purposes. Contents Introduction...3

More information

Written By: Sam Lionheart

Written By: Sam Lionheart ipad Air Wi-Fi LCD Replacement Use this guide to replace the LCD screen in your ipad Air. Written By: Sam Lionheart ifixit CC BY-NC-SA www.ifixit.com Page 1 of 27 INTRODUCTION Replace a damaged or nonfunctioning

More information

Gas Go Anywhere /23/01

Gas Go Anywhere /23/01 Gas Go Anywhere 55014 02/23/01 FOR OUTDOOR USE ONLY This grill does not include an LP fuel tank. Check Package Contents You should have received the parts listed below. While we give much attention to

More information

INSTALLATION INSTRUCTIONS TOWNSEND

INSTALLATION INSTRUCTIONS TOWNSEND INSTALLATION INSTRUCTIONS TOWNSEND.00 DECK MOUNT BATH FILLER.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly-please

More information

PARTS LIST COLT COLT HEPA

PARTS LIST COLT COLT HEPA PARTS LIST COLT 800-1250 - 1450 COLT HEPA - 1250-1450 MOTOR / LID ITEM PART NO. PART DESCRIPTION QTY. 101 0891201 TOP COVER 1 102 0294341 TOP MOTOR SEAL 1 103 0299861 STRAIN RELIEF CORD CLAMP 1 104 0891131

More information

* * 4023 KR. Step 1 Prepare the Keyed Removable Unit. Not for use on electric or fire rated removable mullions

* * 4023 KR. Step 1 Prepare the Keyed Removable Unit. Not for use on electric or fire rated removable mullions condition. *64009-00* 64009-00 Keyed Removable Mullions 403 KR Installation Instructions Not for use on electric or fire rated removable mullions This kit includes the following parts: (Not to scale) 5/6

More information