Evaluation of the COLI-BART system, a novel method for the quantitative detection of total and fecal coliform bacteria in water.

Size: px
Start display at page:

Download "Evaluation of the COLI-BART system, a novel method for the quantitative detection of total and fecal coliform bacteria in water."

Transcription

1 Evaluation of the COLI-BART system, a novel method for the quantitative detection of total and fecal coliform bacteria in water. Abstract Roy Cullimore and Lori Johnston. Droycon Bioconcepts Inc, Regina, Saskatchewan Detection of the coliform bacteria in water remains a very critical method for the determination of health risk. In the last two decades there has developed a need to be able to detect the total or fecal coliform bacteria at the presence / absence (P/A) level in a manner that could be applied at remote locations as well as in the microbiology laboratory. A number of test systems now exist that can undertake this at the P/A or semiquantitative level but quantitative tests still rely on either a version of the membrane filtration (MF) or the most probable number (MPN) technique. The system developed here is the patented COLI-BART system that utilizes the principles of the MPN method (gas production by fermentation) but detects the population size by the rate at which the gas is formed in the test rather than the number of tests in a dilution range that produce gas. Here the premise is that the faster the gas is produced, the greater the original population of coliform bacteria in the water sample. Experiments were conducted using ATCC pure cultures of Escherichia coli and other coliform bacteria as well as using natural samples with known coliform populations. It was found that the time lag measured in seconds by the elevation of a patented gas entrapment thimble could be related to the population size with an accuracy of R 2 of better than 0.8 in a logarithmic regression analysis. With natural samples it was demonstrated that the time lag could be used to generate the most probable population (MPP) with statistical accuracies similar to that of the MPN method. This test method has been found to be functional in the field as well as the laboratory and confirmatory studies are achievable where the completed positive test is returned to a suitable accredited laboratory. Historical Perspective It was as early as 1658, when Athanasius Kircher, a Jesuit priest, first documented a microscopic analysis of the nature of putrifaction. This investigation led to the discovery of bacteria, tiny organisms that can not be seen with the naked eye. Bacteria were first detailed by such great names as Leeuwenhoek, Koch, Pasteur and Lister. It was determined that through sanitation, many of these organisms could be controlled under certain circumstances. Groups of organisms were determined through their function or causation of disease. (Carter and Smith, 1953) The testing for bacteria commonly referred to as coliforms, has been going on for over 100 years. In 1885, colon bacteria, or coliform bacteria in today s common rhetoric, was not a single species of bacterium, but a name applied to a group of organisms whose appearance is too similar to permit differentiation. Many of these bacteria were 1

2 characterized by the available media in which they were cultured. In media containing peptone, idol is formed, where sugar was found, large volumes of gas was produced, sufficient to break apart the media. This can be confirmed through the use of a fermentation tube. Milk and Litmus solutions were also used in the early cultures, producing coagulation and where large quantities of acid was produced, discoloration occurred. (Zapffe, 285) By 1910, further evidence of the colon group, also called lactose fermenters, was confirmed. During this period in history, laboratory techniques remained similar with the use of milk and carbohydrate, particularily sugar, media. Acids produced include lactic, acetic, formic and succinic acids. The fermentation of sugars produce acid and gas, which was a definitive characterization of this group. Nearly all bacteria, 80%, within this group produce gas from the fermentation of lactose. (Park, ) It was also noted that the process of fermentation is not simply a hydrolytic process, but one in which the carbon and oxygen are sundered and formed. The change is through a process of breaking down the sugar molecules, a true decomposition. By the mid 20 th century, the colon group, or coliform group of bacteria continue to be a major issue. New techniques were developed to test for the presence of these organisms. The tests are based on the fact that the coliform organisms belong to a group which ferments lactose with the formation of acid and gas. The testing procedure is broken down into three steps, the presumptive, the partially confirmed and the confirmed test. The presumptive test examines samples for gas formation. If gas is formed it is considered a positive reaction and interpreted as containing lactose-fermenting organisms which may be coliform bacteria. The partially confirmed test consists of streaking the broth culture from step one onto a special lactose agar, such as eosin-methylene blue agar. Differential growth of the organisms assists in the separation of colonies. To confirm the presence of coliform bacteria, the specific colonies grown on agar are transferred to either agar slants or broth and Gram stain and microscopic analysis is done. (Thompson, 1954) There are many disparities when examining, in a quantitative manner, the coliform group. Traditional techniques such as the agar slants or plates, have inherent problems. Historically, the plating techniques have allowed for isolating organisms, obtaining pure cultures and classification or identifying individual types of bacteria as well as enumerating them. This technique is based on the assumption that when a microbial cell grows on solid medium, and care is taken to avoid cell aggregation and excessive cell numbers, that each individual cell will grow and produce an isolated colony Detection of the coliform bacteria in water remains a very critical method for the determination of health risk. In the last two decades there has developed a need to be able to detect the total or fecal coliform bacteria at the presence / absence (P/A) level in a manner that could be applied at remote locations as well as in the microbiology laboratory. A number of test systems now exist that can undertake this at the P/A or semiquantitative level but quantitative tests still rely on either a version of the membrane filtration (MF) or the most probable number (MPN) technique. The system developed 2

3 here is the patented COLI-BART system that utilizes the principles of the MPN method (gas production by fermentation) but detects the population size by the rate at which the gas is formed in the test rather than the number of tests in a dilution range that produce gas. Here the premise is that the faster the gas is produced, the greater the original population of coliform bacteria in the water sample. Experiments were conducted using ATCC pure cultures of Escherichia coli and other coliform bacteria as well as using natural samples with known coliform populations. It was found that the time lag measured in seconds by the elevation of a patented gas entrapment thimble could be related to the population size with an accuracy of R 2 of better than 0.8 in a logarithmic regression analysis. With natural samples it was demonstrated that the time lag could be used to generate the most probable population (MPP) with statistical accuracies similar to that of the MPN method. This test method has been found to be functional in the field as well as the laboratory and confirmatory studies are achievable where the completed positive test is returned to a suitable accredited laboratory. Introduction Coliform bacteria form a part of the enteric bacteria. Particularly important from the health risk viewpoint is that other members of the enteric bacteria play a significant role through causing diseases such as typhoid, food infections (salmonellosis), and bacterial dysentery (shigellosis). In addition there are many other genera of significance as plant pathogens, the causal agents of food spoilage, and of contributing to major activities in the environment. While they can be split into five tribes (Table One), the enteric bacteria are all gram negative rods that are catalase positive and, where motile, possess peritrichous flagella. Most genera will reduce nitrate to nitrite (denitrification). Some of this family are simple chemoorganotrophs able to use glucose as the sole source of carbon and energy, while others are very fastidious requiring various vitamins and amino-acids. All can grow in the presence or absence of oxygen. Table One Differentiation of the five tribes of the Enterobacteriaceae Tribe # I II III IV V Habitat Primarily parasitic in animals Primarily saprophytic, some can be pathogenic Saprophytic Plant pathogens Pathogenic using vectors for transmission The fecal coliform bacteria are represented in Tribe I, consists of five genera, all of which are primarily parasitic in animals with some causing serious diseases particularly in humans. The genera include: Escherichia, Edwardsiella, Shigella, Salmonella and Citrobacter. Escherichia includes many relatively benign strains that parasitize the 3

4 intestine (gastro-enteric tract) of many animals and are particularly dominant in the human species. Some are opportunistic pathogens and can cause forms of diarrhea. Edwardsiella is a common parasitic genus found in reptiles including snakes, toads and frogs. There are many similarities between Escherichia and Edwardsiella that makes differentiation challenging. Shigella is an intestinal pathogen causing bacillary dysentery. Salmonella causes three major infections related to enteric fevers (typhoid, paratyphoid), food infections that can cause gastro-enteritis, and also septicaemia. Citrobacter is essentially a border line genus with the tribe II and includes a range of opportunistic pathogens and also some commonly found in the environment. Fecal coliform bacteria are associated primarily with Escherichia coli in tribe I but some tribe II genera can also trigger as fecal coliform bacteria during coliform testing.. It is interesting to note that the sugar lactose is not commonly found throughout the environment but appears to be synthesized the most commonly in mammalian milk. Mammals when suckling during infancy therefore take in large quantities of lactose in the milk which biases the microflora in the gastroenteric tract to those bacteria that can anaerobically ferment lactose (i.e., coliform bacteria). These coliform bacteria also have to be able to resist the inhibitory effects of bile salts (excreted into the gastroenteric tract) and be able to grow at warm blooded temperatures (e.g., 35 o C). Because of these restrictors, coliform bacteria may be selectively grown in culture conditions where other contaminant bacteria would be suppressed. The restricting factors are the use of lactose as the major energy source; application of bile salts to selectively restrict competition to those bacteria normally found growing in the gastroenteric tract; and the use of an above environmental norm temperature for growing these coliform bacteria (i.e., 37 o C). Acid products are easily determined by colour shifts in ph indicators and the gas may be entrapped for direct or indirect observation 10. Where coliform bacteria are detected then confirmatory tests need to be performed if the presence of Escherichia coli is to be determined. The need to confirm that E. coli is present is important because some of the other coliform group are able to not only survive but also grow within the natural environment. Such microorganisms in a water system would therefore cause a positive coliform test. That test however remains presumptive until the presence of E. coli is confirmed. The most common genera causing these types of interferences are Enterobacter and Klebsiella. Massive increases in the human population and greater exploitation of fresh waters have led to an increasing public sensitivity to the hygienic quality of potable water. Even though many alternative methods for defining hygiene risk in water have been proposed, coliform bacteria have stood the test of time as a reliable indicator group. Consequently the industry to detect coliform bacteria has grown substantially and has been subjected to the latest molecular / immunological test methods such as the ONPG (coliform bacteria) and MUG (E. coli) tests. The recent events at Walkerton, Ontario and North Battleford, Saskatchewan delivered a message that a simple, reliable and robust coliform test was still needed particularly if it could have the following characteristics: Used in remote locations Could be performed by persons without extensive training Could provide positive tests that could then be easily subjected to traditional confirmation using the standard laboratory techniques. 4

5 Methodology Easy to interpret at the visual hands-on level but could also be easily integrated into a computer-controlled package where the data could be generated locally and observed remotely with a provable chain of custody. Long shelf life under minimal storage conditions. To be recognized, the COLI-BART system needs to deliver data comparable to the standard MPN test method with at least the same level of sensitivity to the detection of the targeted coliform bacteria group. This would require a successful statistical comparison of the time lag (TL generated in seconds to fermentation gas generated thimble elevation) to the statistically calculated population generated by the standard MPN method. The following objectives therefore form a part of the objectives to determine the validity of the COLI-BART system: A. The test would be fully quantitative and will generate a most probable population (MPP as opposed to an MPN) estimate for the population size of the coliform bacteria in the sample. B. Can be conducted at remote locations (with an assured repeatability and satisfactory chain of custody). C. Operator time is reduced to less than five minutes for initiating the test procedure. D. Test completed in 24 hours for the total coliform and 30 hours for the fecal coliform. E. Involves using a single test utilizing 100ml of water sample to conduct a quantitative test. F. Population of coliform bacteria is predicted on-screen as soon as the activities of the coliform bacteria are detected (usually from 4 to 27 hours depending upon the population size of coliform bacteria being detected in the sample). G. The COLI-BART readers would have a one-year over-the-counter replacement warranty and would be expected to last a minimum of three operating years. See product specifications (3.6) for more information on the readers. H. While the reader has been designed for use under common conditions where conditions are dry and cool, the reader has not been protected against extremely wet and corrosive conditions. Due diligence should be employed in the location of the reader. I. 100ml of sample is added to initiate the test and this act dilutes the selective medium to the correct strength for the particular coliform bacteria test being conducted. J. All completed COLI-BART testers would be returned to a laboratory for disposal (even where negative for coliform bacteria) with the option, where positive, for subsequent confirmation of the presence of the coliform bacteria in the culture created by the test. K. The double-wrapping of the completed COLI-BART tester provides additional protection from accidental spillage. This would be an advantage to the user since this would also provide a safe method of disposal or laboratory confirmation of the coliform bacteria present in the sample if required. L. Storage life for a COLI-BART tester is three years when stored in a sealed aluminum foil pouch (standard practice in all BART testers). It is recommended that the product 5

6 be stored in a cool dry environment. M. Variability resulting from minor differences between the various operators performing the coliform tests should be reduced since the number of operatorinitiated steps are reduced to simply filling the tester, burping the thimble, placing the tester into an available channel in a reader and initiating the test. Disposal parallels methods already in common use. N. To reduce risk to the human handling the container, the COLI-BART tester is provided with a second flexible plastic bag that is sealed once the sample has been added. This outer bag acts as a secondary barrier to prevent the release of any cultured material being generated within the test. Contact time for the operator setting up the test is minimized. O. A chain of custody is assured through a unique serial number that is etched onto the tester. Each tester would be shipped within an outer container (when not use in a laboratory) that would allow all used vials to be returned to a designated laboratory for any confirmatory work that may need to be conducted and safe disposal. The only direct exposure to the contents of the tester would be at the point of filling prior to sealing the outer protective bag and insertion into the reader. Shipping of new testers would be through normal courier services with the testers already in the containers that would be used to ship the completed test back to the laboratory for disposal. The chain of custody would be from the manufacturer to the wholesaler to the end user who returns the completed tester back to a suitable disposal / confirmatory facility. The serial number for each tester would allow the tracking of each tester through the chain of custody. P. All operators and operators of the COLI-BART system would have to go through a training program to assure that the testing process was conducted in a suitable manner. The principles of the COLI-BART system are based upon the ability of coliform bacteria to ferment selective culture media with the production of gas. Traditionally the gas, where it is used as the indicator of coliform presence, is collected within an inverted glass (Durham's) tube. The gas collects as a visible bubble at the upper (closed) end of this tube. Population assessment is made through a statistically appropriate multiplicity of diluents of the water sample in which only some generate gas. This method is known as the multiple tube method and generates a most probable number (MPN) statistically as an indicator of the size of the coliform population. In this technique, the Durham's tube is sometimes difficult to view under test conditions due to clouding of the culture medium. In the COLI-BART tester, the Durham's tube is replaced with a patented gas D thimble. The unique feature of this device is that it consists of a series of slots within an inverted plastic container having a density that is greater than the culture medium with the water sample added. This allows the D thimble to sink. The (patent pending) version II of the device allows for a free movement of cells and chemicals through the slots between the D thimble device (version II) and the rest of the liquid medium. This is not possible in the glass walled Durham's tube. When gases are produced by fermentation, some of theses gases will collect inside and reduce the density of the device. As the gas forms, therefore, the D thimble rises up (as the density drops) through the incubating 6

7 sample to the surface marking the fact that gas has been produced. Visible interpretation of the test is therefore simple (D thimble down is negative, D thimble up and floating is positive). There is a relationship existing between population and the time lag to the vertical relocation of the D thimble. Here, the greater the size of the population then the sooner the D thimble will elevate. In the statistical evaluation of the COLI-BART test method, comparisons were made between the time lag to elevation (TL) and the population sizes for various pure (ATCC) cultured and natural populations of coliform bacteria. Two formats of the biodetectors have been developed. The first system detects the total (general) coliform population and is known as the T-COLI BART. The medium includes beef extract, peptone, lactose, tryptone/tryptose, dipotassium hydrogen phosphate, potassium dihydrogen phosphate, sodium chloride, sodium lauryl sulfate and bromocresol purple. The second system is more specifically designed to detect the fecal coliform bacteria uses brilliant bile green broth (F-COLI BART). This culture medium restricts the range of coliform bacteria able to ferment and produce gas to the target group comprised mainly of Escherichia coli. All of the tests were performed at temperatures of 37±1.0 o C using a baseline of 100 ml of double strength medium which was diluted to the correct final strength with a 100 ml water sample which had been appropriately prepared (e.g., as a natural water sample or a suspension of a known diluent of a 24 hr broth culture of a specific bacterial strain). The cultural conditions would be similar to the standard MPN techniques bearing similar potentials for false negatives (failure to detect presence) and false positives (detected activity not confirmed for the targeted organism). The provisional limits and conditions for testing using the COLI-BART system would be: Threshold detection limit (minimal): 1 cell per 100ml of sample Threshold detection limit (maximal): 10 billion cells per 100ml of sample Time length limitation: Total coliform bacteria, 20 hours Fecal coliform bacteria, 27 hours E. coli bacteria, 24 hours Water sample size: 100±2ml Water sample clarity: < 40 N.T.U. Water sample density: 15 o C Water sample salinity: 15 o C Water sample storage: following the standard conditions laid down in the Standard Methods for the Examination of Water and Waste Water. Container: PET bottle with a capacity of 250ml Medium volume: 75±1ml ml of x2.34 strength sterile liquid selective medium Sample volume: 100±2ml Total Liquid volume: 175±3ml Height of detection light pathway to detect thimble elevation: 63mm to midpoint lateral 7

8 Height of gas detection thimble: Entrapment volume within the thimble: 3.6ml Volume of gas required to elevate the thimble in distilled water: 0.4±0.01ml Density of the gas detection thimble: 1.08 Ratio of slat area with closed area in lower part of the gas detection thimble: 1: 1.5 The patented components in the system are: COLI-BART system has a basic set-up that is similar to the BOD-BART system in that here are two components that form the system. These are described below as a tester (that performs an individual test) and the reader (that is able to monitor a multitude of testers concurrently and generate a predicted population for the samples under test). COLI-BART tester is a 250ml plastic sterile bottle that contains a dense plastic D thimble and 75ml of the appropriate selective culture medium that is recognized for the purposes of detecting either total coliform bacteria (T-COLI BART) or fecal coliform bacteria (F-COLI BART). The tester is sleeved in a clear plastic pouch to provide additional protection to the user, allow improved shipment of the final tester for disposal, and help to ensure that the culture within the positive finished tester could be securely taken to the laboratory for confirmatory testing and disposal. The technology for manufacturing the tester already exists. This would include aseptic procedures, clean air dispensing and adequate quality management. Outstanding issues relate to the form and functionality of the D thimble. The D thimble (version II) could also function in brackish (coastal) waters by the use of a density modifying attachment. COLI-BART reader primarily consists of the necessary hardware / software to be able to detect the upwards movement of the D thimble in the COLI-BART tester being incubated. This detection is achieved by the blocking off of an infra-red light pathway through the testers liquid medium by the D thimble once it has elevated by more than 4mm from its sunken position in the tester. Quantitative information is obtained by correlating the time lag to the thimble elevation given that the larger the population of coliform bacteria then the more rapid would be the generation of gases to cause the thimble to elevate. Product System Potential major users of coliform detection system is listed in Table Two. Table Two Potential User Groups for the Various BART Products Potable Water Waste Water Treatment Oil & Gas Industry Chemical Industry Environ. Industry Agriculture COLI-BART *** *** * ** *** *** Note: The potential for each industry listed in each column is shown by the number of asterisks defined below: 8

9 *** Could become an essential routine part of the testing / diagnostic procedure ** Under some circumstances could become a part of the routine testing but would be a valuable diagnostic tool under some conditions * May have considerable value under some limited conditions Results and Discussion At all stages, spreadplate analyses of the diluents and natural samples were used to obtain duplicate population assessments. Regression correlations (R 2 ) were calculated by linear regression analysis of the TL obtained to the populations of coliform bacteria determined by spreadplate analysis. In all cases the TL was determined as the time delay to the blocking of a near infra-red light pathway set 4 mm below the surface of the cultured medium. Monitoring for the TL event (elevation of the D thimble) was controlled by a microprocessor-driven software program. Three ATCC strains of Escherichia coli (ATCC 25922, and 11229) were subjected to triplicate trials using tenfold dilutions of the cell suspension down from 10 7 to 10-2 cells /100mL. Using the T-COLI BART protocol, triplicate analyses were performed. The correlations between the population density in the samples and the TL obtained for each individual trial were very good (R 2 values of 0.89, 0.96, 0.83, 0.81, 0.86, 0.96, 0.93, 0.83, 0.91). Pooling the data into a single scatter gram gave a reduced regression correlation with an R 2 value of 0.66 due to the variations inherent between the different strains of Escherichia coli used. The regression correlation equation for the pooled data was calculated to be: y = 0.5 x Where x is the time delay to D thimble elevation expressed in TL recorded as hours of delay. Y is the log population of coliform bacteria. The standard deviation around the y value was In general, higher levels of correlations were observed between the F-Coli BART tests using the same strains of Escherichia coli. Respective R 2 values were: 0.98, 0.96, 0.91, 1.00, 0.94, 0.60, 0.89, 0.88 and 0.83 to give a total scatter gram R 2 of 0.74 (compared to 0.66 for the T- protocol). The regression correlation equation for the pooled data was calculated to be: y = 0.47 x where x is the time delay to D thimble elevation expressed in TL recorded as hours of delay while y is the log population of coliform bacteria. The standard deviation around the y value was While the incubation time of 24 hours appears to be more than adequate to recover low populations of coliform bacteria using the T- protocol, there has been incidents (one in every six occasions) where very low populations of coliform bacteria (<4 cells/100 ml) fail to cause D thimble in 24 hours in the F- protocol. It is recommended that for the F-COLI BART test procedure, the incubation period should routinely be extended to 30 hours in order to recover these very low coliform samples as positive. In practise, it has generally been noticed that all D thimble elevation in these very low population conditions occurs by 28 hours. The recommendation of 30 hours for incubation provides an additional two hour "safety" window. 9

10 Investigations in the summer of 2002 at a Saskatchewan POTW were focussed on the comparison of the TL for the T- and F- COLI-BART and the bacteriological data generated by the POTW using spread plate agar techniques. Typical variability for a single duplicate run is shown in Table Three and a summary of the variability for samples drawn through the third week of July (15 22, 2002) is given in Table Four. Table Three Single day variability in TL (seconds) and bacterial plate counts (Bact. colony forming units/100ml) for tertiary influent (TI), tertiary effluent (TE) and final effluent (FE) COLI-BART system Bact. Bact. Bact. TI TE FE TI TE FE TC Average % 0.8% 3.0% 4.8% 20.2% 47.1% FC Average Stand. Dev % variability 1.4% 5.7% 6.2% 2.8% 22.5% 20.2% Table Four Summary of data comparisons for the T- and F- COLI BART tests against Bacteriological Counts (cfu/100ml) for POTW tertiary influent (TI), tertiary effluent (TE) and final effluent (FE) unit TI (T-Coli) TE (T-Coli) FE (T-Coli) TI (cfu/100ml) TE (cfu/100ml) FE (cfu/100ml) Average 35,802 43,254 50, ,000 54, TL Av ,154 4,416 21,213 17, Stand. Dev. % var. 2.8% 3.6% 8.5% 7.4% 27.3% 24.6% (F- COLI) (F- COLI) (F- COLI) Fecal bacteria Fecal bacteria Fecal bacteria Average 44,309 50,482 61,491 14, TL Av ,240 2, Stand. Dev. % var. 1.8% 11.6% 14.6% 2.8% 32.6% 50.7% 10

11 *Note: the percentage variability is an average of the variability determined from the means and standard deviations for all of the relevant trials. An inverse relationship between the TL (getting longer) as the bacterial population detected gets smaller through the treatment process (TI TE FE). Going downstream through the treatment variability increased from (T- : F- COLI BART TL) from % to % while, for the bacterial counts the variability was much more pronounced increasing from % and % for the total and fecal coliform bacteria. A similar trend was established for the seven day study period (given in Table Four) where the variability was (for the T- and F- COLI BART) % rising to % while the bacterial counts using the appropriate spreadplate techniques showed a variability rising from % to 24.6 and 50.7% from the TI to the FE. These differences are also shown in Figure One. Figure One Mean % variability for the four methods applied to the tertiary influent (1), Tertiary effluent (2) and final effluent (3). Variability of COLI-BART against spreadplate 60.0% 50.0% % varaition (sd/average) 40.0% 30.0% 20.0% T-Coli-BART Total Coli bacti F-Coli-BART Fecal Coli bacti 10.0% 0.0% TI, 2 - TE, 3 - FE The prime feature used in the MPN test is the determination of presence by the evolution of gases by fermentation during the test procedure. In the standard MPN using the small Durham s tube the total gas containment possible is 0.98 ml over a 50mm length meaning that each mm of gas entrapped within the tube would represent 0.02mL of gas collected. If the Durham s tube were to be used during an MPN procedure then the void volume (retained within the tube) ratio to the total volume (10mL) would be 1: 11

12 0.098 which means that much of the fermentation gases generated outside of the tube would not be captured leaving the efficiency of the system at collecting gas at less than 10%. In the COLI-BART system the D thimble has a constricted volume of 19.8 ml and a contained volume (total gas entrapment) of 5.29 ml. Elevation of the D thimble occurs when 0.4 ml of gas has been collected and the liquid medium has been displaced from the top 0.9 mm under the top plate of the D thimble. For the D thimble then the void volume (retained within the tube) ratio to the total volume (10mL) would be 1: 0.12which means that much of the fermentation gases generated outside of the tube would not be captured leaving the efficiency of the system at collecting gas at 12 % when submerged but this would increase as the D thimble elevates to the surface of the medium. This may be witnessed by the ongoing movement of the D thimble out of the liquid medium (Table Five) after a positive detection has been declared. Table Five Elevation of the D thimble out of the liquid medium after a COLI-BART Has been declared positive. Volume gas Entrapped (ml) T-COLI Volume gas Entrapped (ml) F-COLI Height (cm) T-COLI thimble Height (cm) F-COLI thimble TI cm 1.0 cm cm 1.0 cm TE cm 1.2 cm cm 1.1 cm FE cm 0.6 cm cm 0.5 cm *Note: the maximum contained volume in the D thimble would be 5.3 ml before gases would bleed out of the underside of the device. The data establishes the potential for an effective quantitative link between the traditional MPN test for the coliform bacteria that are present in waters and waste waters and the proposed possible population number (PPN) that would be based on the time lag preceding the evolution of sufficient gases to trigger the elevation of the D thimble. Such a COLI-BART system-based biotechnology would allow the use of a single vessel to determine quantitatively the population of the targeted coliform bacteria in the water or waste water sample. In this PPN system the major diversion from the standard protocols would be the replacement of the Durham s tube with the D thimble and then the quantification of the population using the time lag measured in seconds from the start of the test to the elevation of the D thimble to the medium/air interface. 12

13 Conclusions The patented COLI-BART system when applied to comparable studies against pure culture and natural samples showed a relationship existed between the time lag to the population size (from the pure culture studies) and also indicated a better precision in the quantitative determination of coliform bacteria populations in water and waste water samples. There are clear advantages in the proposed system in that it would be simpler to operate, have the potential to contain re-usable components (vessel, D thimble and cap) and would develop data that would have precision. Further testing is planned now to compare this system to the other commercially available methods for the determination of the presence of coliform bacteria. Acknowledgements The authors wish to acknowledge the very significant help that was received through the supply of samples, data and encouragement that was received from the many operators at the various sewage treatment plants who provided samples and data Also the financial assistance of the National Research Council of Canada through the Research Development Assistance program operated by the Industrial Research Assistance Program is acknowledged. References Alford, G. A., Rogers, W. and Cullimore, D.R., Well Cleaning Methods and Apparatus. U.S. Patent Number: Buchanan, R.E., and N.E. Gibbons, Bergey s Manual of Determinative Bacteriology. R.E. Buchanan and N.E. Gibbons, Co-ed., The Williams & Wilkins Company, Baltimore, MD. Carter, Charles F., and Alice L. Smith, Microbiology and Pathology. Fifth Edition. The C.V. Mosby Company, St. Louis, MI. Cullimore, D.R., Practical Manual of Groundwater Microbiology. Lewis Publishers, Chelsea, MI. Cullimore, D.R., Microbiology of Well Biofouling. Sustainable Water Well Series, D.R. Cullimore, Series ed., Lewis Publishing/CRC Press, Boca Raton, Florida. Cullimore, D.R., Practical Atlas for Bacterial Identification. D.R. Cullimore, Lewis Publishing/CRC Press, Boca Raton, Florida. Cullimore, D.R. and Alford, G.A., Method and Apparatus Producing Analytic Culture. U.S. Patent Number: 4,906,

14 Cullimore, D.R. and Johnston, L., Microbial Issues in Water Using an Innovative Detection System. Water Conditioning & Purification Magazine. November Issue. Droycon Bioconcepts Incorporated, BART User Manual, 2000 Edition. Inhouse Publication. Hattori, T., The Viable Count. Science Technology Publishers, Madison Wisconsin. Park, William Hallock and Anna W. Williams, Pathogenic Micro-organisms including Bacteria and Protozoa. Fourth Edition. Lea & Febiger, New York, NY. Thompson, LaVerne Ruth, Introduction to Microorganisms. Third Edition. W.B. Saunders Company, Philadelphia, PA. Vinebrooke, R. D. and Cullimore, D.R., Natural Organic Matter and the Bound- Water Concept in Aquatic Ecosystems. Reviews of Environmental Contamination and Toxicology. Volume 155. Zapffe, Fred C. M.D., Bacteriology, A Manual for Students and Practitioners. Series ed., Bern B. Gallaudet, M.D. Lea Brother & Co, New York. 14

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE Translated English of Chinese Standard: GB4789.3-2016 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA GB 4789.3-2016 National food safety standard

More information

Petrifilm. Interpretation Guide. Coliform Count Plate. Brand

Petrifilm. Interpretation Guide. Coliform Count Plate. Brand Petrifilm Brand Interpretation Guide The 3M Petrifilm is a sample-ready culture medium system that contains modified Violet Red Bile nutrients, a cold-water-soluble gelling agent and a tetrazolium indicator

More information

3M TM Petrifilm TM. Petrifilm TM 3M TM. 3M TM Petrifilm TM Serie 2000 Rapid Coliform Count Plates - Ref.: / 50 Unit - Ref.

3M TM Petrifilm TM. Petrifilm TM 3M TM. 3M TM Petrifilm TM Serie 2000 Rapid Coliform Count Plates - Ref.: / 50 Unit - Ref. 3M TM Aerobic Count Plates - Ref.: 06400 / 100 Unit - Ref.: 06406 / 1000 Unit 3M TM Enterobacteriaceae Count Plates 3M TM Coliform Count Plates - Ref.: 06420 / 50 Unit - Ref.: 06421 / 1000 Unit - Ref.:

More information

HSCC. Interpretation Guide. High-Sensitivity Coliform Count Plate

HSCC. Interpretation Guide. High-Sensitivity Coliform Count Plate Interpretation Guide The 3M Petrifilm High-Sensitivity Coliform Count Plate is a sample-ready-culture medium system which contains modified Violet Red Bile (VRB) nutrients, cold-water-soluble gelling agent,

More information

Interpretation Guide. Coliform Count Plate

Interpretation Guide. Coliform Count Plate Interpretation Guide The 3M Petrifilm is a sample-ready-culture medium system which contains modified Violet Red Bile nutrients, a cold-water-soluble gelling agent and a tetrazolium indicator that facilitates

More information

Food Microbiological Examination: Enumeration of Coliforms

Food Microbiological Examination: Enumeration of Coliforms Translated English of Chinese Standard: GB4789.3-2010 Translated by: www.chinesestandard.net Wayne Zheng et al. Email: Sales@ChineseStandard.net NATIONAL STANDARD GB OF THE PEOPLE S REPUBLIC OF CHINA GB

More information

Gently apply pressure on spreader to distribute over circular area. Do not twist or slide the spreader. Interpretation

Gently apply pressure on spreader to distribute over circular area. Do not twist or slide the spreader. Interpretation 0 With flat side down, place spreader on top film over inoculum. Gently apply pressure on spreader to distribute over circular area. Do not twist or slide the spreader. 2 Lift spreader. Wait at least one

More information

REC. Interpretation Guide. Rapid E. coli/coliform Count Plate

REC. Interpretation Guide. Rapid E. coli/coliform Count Plate Interpretation Guide The M Petrifilm Rapid E. coli/coliform Count Plate is a selective and differential sample-ready-culture medium system which contains proprietary nutrients, a cold-watersoluble gelling

More information

Interpretation Guide 3M Petrifilm Rapid Coliform Count Plates

Interpretation Guide 3M Petrifilm Rapid Coliform Count Plates 3M Petrifilm Interpretation Guide 3M Petrifilm Rapid Coliform Count Plates This guide should familiarize you with results on Petrifilm Rapid Coliform Count (RCC) plates as defined by three of the most

More information

Comparison of Gelman and Millipore Membrane Filters for Enumerating Fecal Coliform Bacteria

Comparison of Gelman and Millipore Membrane Filters for Enumerating Fecal Coliform Bacteria APPLIED MICROBIOLOGY, Sept. 1973, p. 332-336 Copyright 0 1973 American Society for Microbiology Vol. 26, No. 3 Printed in U.S.A. Comparison of Gelman and Millipore Membrane Filters for Enumerating Fecal

More information

Addressing challenges associated with the detection of faecal coliform organisms in water matrices. Neil Leat Rand Water Date 30/09/2014

Addressing challenges associated with the detection of faecal coliform organisms in water matrices. Neil Leat Rand Water Date 30/09/2014 Addressing challenges associated with the detection of faecal coliform organisms in water matrices Neil Leat Rand Water Date 30/09/2014 What are coliforms? Definitions of coliforms are based on biochemical

More information

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE CC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE CC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE CC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES INTRODUCTION Peel Plate CC (Coliform Count) tests diffuse the

More information

Coliform Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Coliform Count Plate

Coliform Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Coliform Count Plate M Food Safety M Petrifilm Coliform Count Plate Coliform Count Interpretation Guide This guide familiarizes you with results on M Petrifilm Coliform Count Plates. For more information, contact the official

More information

COLILERT - WHAT'S AL THE FUSS ABOUT? Elizabeth Hanko. Elizabeth Hanko, Senior Consultant. AWT, Victoria

COLILERT - WHAT'S AL THE FUSS ABOUT? Elizabeth Hanko. Elizabeth Hanko, Senior Consultant. AWT, Victoria COLILERT - WHAT'S AL THE FUSS ABOUT? Paper Presented by : Elizabeth Hanko Author: Elizabeth Hanko, Senior Consultant AWT, Victoria 63 rd Annual Water Industry Engineers and Operators Conference Civic Centre

More information

Interpretation Guide

Interpretation Guide 3M Petrifilm Interpretation Guide 3M Petrifilm Coliform Count Plates This guide familiarizes you with results on 3M Petrifilm Coliform Count Plates (CC). For further information, please contact the 3M

More information

Interpretation Guide

Interpretation Guide 3M Petrifilm Interpretation Guide 3M Petrifilm Coliform Count Plates This guide familiarizes you with results on 3M Petrifilm Coliform Count Plates (CC). For further information, please contact the 3M

More information

TACWA September Meeting CHALLENGES IN MEETING THE TEXAS BACTERIAL LIMITS WITH UV ALONG THE COAST AND BAYS. Gennady Boksiner, P.E. September 30, 2011

TACWA September Meeting CHALLENGES IN MEETING THE TEXAS BACTERIAL LIMITS WITH UV ALONG THE COAST AND BAYS. Gennady Boksiner, P.E. September 30, 2011 TACWA September Meeting CHALLENGES IN MEETING THE TEXAS BACTERIAL LIMITS WITH UV ALONG THE COAST AND BAYS Gennady Boksiner, P.E. September 30, 2011 Bacterial Groups Intestinal bacteria of humans and other

More information

Coliforms as Indicator of Faecal Pollution

Coliforms as Indicator of Faecal Pollution World Bank & Government of The Netherlands funded Training module # WQ - 22 Coliforms as Indicator of Faecal Pollution New Delhi, June 1999 CSMRS Building, 4th Floor, Olof Palme Marg, Hauz Khas, New Delhi

More information

Evaluation copy. Fecal Coliform. Computer INTRODUCTION

Evaluation copy. Fecal Coliform. Computer INTRODUCTION Fecal Coliform Computer 9 INTRODUCTION The concentration of fecal coliform bacteria in water is measured to determine the likelihood of contamination by microbiological organisms. While fecal coliform

More information

Oregon Department of Human Services HEALTH EFFECTS INFORMATION

Oregon Department of Human Services HEALTH EFFECTS INFORMATION Oregon Department of Human Services Office of Public Health Systems (503) 731-4030 Emergency 800 NE Oregon Street #611 (503) 731-4381 Portland, OR 97232-2162 (503) 731-4077 FAX (503) 731-4031 TTY-Nonvoice

More information

Sampling for Microbial Analysis

Sampling for Microbial Analysis Sampling for Microbial Analysis Linda J. Harris, Ph.D. Department of Food Science and Technology ljharris@ucdavis.edu Microbial Testing One of the most apparent but poorly understood parts of food microbiology

More information

Gas Chromatographic Presumptive Test for Coliform Bacteria in Water

Gas Chromatographic Presumptive Test for Coliform Bacteria in Water AmPID MICROBIOLOGY, Oct. 1975, P. 584-588 Copyright X) 1975 American Society for Microbiology Vol. 30, No. 4 Printed in U.SA. Gas Chromatographic Presumptive Test for Coliform Bacteria in Water JUDITH

More information

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE EC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE EC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES Peel Plate EC-E.coli and Coliform Peel Plate EC-E.coli and Coliform Peel Plate EC-E.coli INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE EC TESTS. FOR MORE INFORMATION,

More information

Core practical 13: Isolate an individual species from a mixed culture of bacteria using streak plating

Core practical 13: Isolate an individual species from a mixed culture of bacteria using streak plating Core practical 13 Teacher sheet Core practical 13: Isolate an individual species from a mixed culture of Objectives To successfully use streak plating techniques to isolate a single species of bacteria

More information

Project Summary. Principal Investigators: Lawrence D. Goodridge 1 ; Phil Crandall 2, and Steven Ricke 2. Study Completed 2010

Project Summary. Principal Investigators: Lawrence D. Goodridge 1 ; Phil Crandall 2, and Steven Ricke 2. Study Completed 2010 Project Summary Validation of the use of Citrus Essential Oils as a Post Harvest Intervention against Escherichia coli O157:H7 and Salmonella spp. on Beef Carcasses Principal Investigators: Lawrence D.

More information

Comparison of the Novel ColiPlate

Comparison of the Novel ColiPlate Comparison of the Novel ColiPlate TM Kit and the Standard Membrane Filter Technique for Enumerating Total Coliforms and Escherichia coli Bacteria in Water Ran Lifshitz, 1 Renu Joshi 2 1 Environmental Biodetection

More information

Overview of Microbial Indicator Monitoring Lab Methods. Jim Ferretti, USEPA Region 2 DESA, Laboratory Branch May 23, 2018

Overview of Microbial Indicator Monitoring Lab Methods. Jim Ferretti, USEPA Region 2 DESA, Laboratory Branch May 23, 2018 Overview of Microbial Indicator Monitoring Lab Methods Jim Ferretti, USEPA Region 2 DESA, Laboratory Branch May 23, 2018 Water Contamination and Public Health 1854- John Snow mapped and correlated incidence

More information

Kit Information 3. Sample Preparation 4. Procedure 4. Analysis of Results 5. Quality Control 6. Disposal 6. Technical Support 6. Order Information 6

Kit Information 3. Sample Preparation 4. Procedure 4. Analysis of Results 5. Quality Control 6. Disposal 6. Technical Support 6. Order Information 6 Contents Kit Information 3 Introduction......................................... 3 Kit Contents, Storage, and Testing Conditions..................... 3 Principle...........................................3

More information

VALIDATION OF DRY-AGING AS AN EFFECTIVE INTERVENTION STEP AGAINST ESCHERICHIA COLI O157:H7

VALIDATION OF DRY-AGING AS AN EFFECTIVE INTERVENTION STEP AGAINST ESCHERICHIA COLI O157:H7 VALIDATION OF DRY-AGING AS AN EFFECTIVE INTERVENTION STEP AGAINST ESCHERICHIA COLI O157:H7 ON BEEF CARCASSES A UNIVERSITY OF WISCONSIN-MADISON RESEARCH REPORT BY STEVEN C. INGHAM AND DENNIS R. BUEGE 2003

More information

3M Food Safety 3M Petrifilm Plates and 3M Petrifilm Plate Reader

3M Food Safety 3M Petrifilm Plates and 3M Petrifilm Plate Reader 3M Food Safety 3M Petrifilm Plates and 3M Petrifilm Plate Reader brilliant. This red dot changed microbiology. Imagine what it can do for your lab. In today s environment of heightened focus on food safety

More information

Colilert * -18 A faster, easier way to test for total coliforms and E. coli

Colilert * -18 A faster, easier way to test for total coliforms and E. coli Colilert * -18 A faster, easier way to test for total coliforms and E. coli With Colilert * -18, coliforms and E. coli have nowhere to hide At IDEXX, we re unequivocally committed to ensuring that the

More information

Pr oject Summar y. Survey of the prevalence of Escherichia coli O157:H7 on the surface of subprimal cuts of beef during winter months (Phase I)

Pr oject Summar y. Survey of the prevalence of Escherichia coli O157:H7 on the surface of subprimal cuts of beef during winter months (Phase I) Pr oject Summar y Survey of the prevalence of Escherichia coli O157:H7 on the surface of subprimal cuts of beef during winter months (Phase I) Principal Investigators: J. E. (Ken) Kennedy ABC Research

More information

3M Food Safety 3M Petrifilm Plates and Reader. Simply. Prompt. Precise. Productive.

3M Food Safety 3M Petrifilm Plates and Reader. Simply. Prompt. Precise. Productive. 3M Food Safety 3M Petrifilm Plates and Reader Simply Prompt. Precise. Productive. brilliant. This red dot changed microbiology. Imagine what it can do for your lab. In today s environment of heightened

More information

Indicator organisms. !Group of microorganisms use to reflect the quality and safety of a process food product

Indicator organisms. !Group of microorganisms use to reflect the quality and safety of a process food product Indicator Organisms Indicator organisms!group of microorganisms use to reflect the quality and safety of a process food product!indicator organism in water!vibrio cholera!salmonella typhi!shigella spp!coliforms

More information

Food Stamp Hygiene control on food and food Environment

Food Stamp Hygiene control on food and food Environment Food Stamp Hygiene control on food and food Environment Table of contents 1. Introduction... 3 2. Features and benefits... 4 3. Product Overview... 5 4. Instructions for use... 7 5. How to read colonies...

More information

IDEXX Summary. D P Sartory and C Allaert Vandevenne

IDEXX Summary. D P Sartory and C Allaert Vandevenne IDEXX Summary 2T Topic Title Authors Review of studies in France leading to AFNOR Certification Validation mark for Colilert -18 / Quanti-Tray for the testing of drinking water samples Improved methods

More information

Loyalsock Creek Bacterial Coliforms. Presented By: Dr. Mel Zimmerman Clean Water Institute Lycoming College Matthew Bennett Jim Rogers

Loyalsock Creek Bacterial Coliforms. Presented By: Dr. Mel Zimmerman Clean Water Institute Lycoming College Matthew Bennett Jim Rogers Loyalsock Creek Bacterial Coliforms Presented By: Dr. Mel Zimmerman Clean Water Institute Lycoming College Matthew Bennett Jim Rogers What is E. coli? Short for Escherichia coli (a bacteria) It is a

More information

Protecting Consumers. Improving lab efficiency. 3M Petrifilm Plates and Reader

Protecting Consumers. Improving lab efficiency. 3M Petrifilm Plates and Reader Protecting Consumers. Improving lab efficiency. 3M Petrifilm Plates and Reader Simply brilliant. This red dot changed microbiology. Imagine what it can do for your lab. In today s environment of heightened

More information

Food Stamp Hygiene control on food and food environment

Food Stamp Hygiene control on food and food environment Food Stamp Hygiene control on food and food environment Table of contents 1. Introduction... 3 2. Features and benefits... 4 3. Product Overview... 5 4. Instructions for use... 7 5. How to read colonies...

More information

Bacteriological testing of water

Bacteriological testing of water MOBILE NOTE 6 Bacteriological testing of water Introduction Bacteriological water testing is a method of collecting water samples and analysing those samples to estimate the numbers of bacteria present.

More information

r., C D C5,) -I2ET dun 241,%3 Sco C)6 C-.) TISIA TECHNICAL DOCUMENTARY REPORT AAL-TDR-6Z-55 AAL- TDR-62-55

r., C D C5,) -I2ET dun 241,%3 Sco C)6 C-.) TISIA TECHNICAL DOCUMENTARY REPORT AAL-TDR-6Z-55 AAL- TDR-62-55 AAL- TDR-62-55 ItHANGES IN THE INTESTINAL FLORA OF GROUND SQUIRRELS DURING PERIODS OF HIBERNATION J. P. Schmidt R. E. Becker S0 Sco C)6 TECHNICAL DOCUMENTARY REPORT AAL-TDR-6Z-55 March 1963 LLJ r., C D

More information

FINAL Water Year 2012 Bacteria Sampling Report for the Klamath River Estuary

FINAL Water Year 2012 Bacteria Sampling Report for the Klamath River Estuary FINAL Water Year 2012 Bacteria Sampling Report for the Klamath River Estuary Prepared by: Patrick Fox Yurok Tribe Environmental Program April 2013 Acknowledgements The Yurok Tribe Environmental Program

More information

Tufts University Water: Systems, Science, and Society (WSSS) Program

Tufts University Water: Systems, Science, and Society (WSSS) Program To: From: John Foster, Elbow Cay, the Bahamas; Friends of the Environment, Marsh Harbor, the Bahamas Alex Bedig, Amanda Garfield, Shonda Gaylord, Jack Melcher, Melissa Ng, Nathan Rawding, Kendall Webster,

More information

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE Table of Contents TEACHER S MANUAL Overview....3 Objectives............................................................. 3 Correlation to Science Standards...3

More information

Kit Information 4 Introduction. 4 Kit Contents, Storage, and Testing Conditions. 4 Equipment Needed. 4 Applicability. 4 Precautions... 4.

Kit Information 4 Introduction. 4 Kit Contents, Storage, and Testing Conditions. 4 Equipment Needed. 4 Applicability. 4 Precautions... 4. Contents 3 Kit Information 4 Introduction. 4 Kit Contents, Storage, and Testing Conditions. 4 Equipment Needed. 4 Applicability. 4 Precautions.......................... 4 Procedure 6. Analysis of Results

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Certified Laboratories of the Midwest, Inc.

More information

Project Summary. Principal Investigators: Chance Brooks, Mindy Brashears, Mark Miller, Alejandro Echeverry, and Cassandra Chancey

Project Summary. Principal Investigators: Chance Brooks, Mindy Brashears, Mark Miller, Alejandro Echeverry, and Cassandra Chancey Project Summary The Effect of Lactic Acid and Cooking on the Survivability of E. coli O157:H7 in Needle Tenderized Beef Steaks Managed Under Simulated Industry Conditions Principal Investigators: Chance

More information

BACTERIAL CONTAMINATION OF WATER WELLS AND SPRINGS

BACTERIAL CONTAMINATION OF WATER WELLS AND SPRINGS 4/15/215 BACTERIAL CONTAMINATION OF WATER WELLS AND SPRINGS Bryan Swistock Water Resources Specialist Penn State Extension Department of Ecosystem Science and Management Microbiological Parameters Standard

More information

BACTERIOLOGICAL MONITORING 109 TRAINING COURSE $ HOUR RUSH ORDER PROCESSING FEE ADDITIONAL $50.00

BACTERIOLOGICAL MONITORING 109 TRAINING COURSE $ HOUR RUSH ORDER PROCESSING FEE ADDITIONAL $50.00 Registration form BACTERIOLOGICAL MONITORING 109 TRAINING COURSE $50.00 48 HOUR RUSH ORDER PROCESSING FEE ADDITIONAL $50.00 Start and finish dates: You will have 90 days from this date in order to complete

More information

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT 4-3616-UV blank WARNING! This set contains chemicals that may be harmful if misused. Read cautions on individual containers carefully. Not to be used

More information

Comparison of Enterococci and Coliform Microorganisms in

Comparison of Enterococci and Coliform Microorganisms in Comparison of Enterococci and Coliform Microorganisms in Commercially Produced Pecan Nut Meats JAMES B. HYNDMAN U.S. Department of Health, Education, and Welfare, Food and Drug Admninistration, Dallas

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Certified Laboratories of the Midwest, Inc.

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI National Accreditation Board 11617 Coldwater Road, Fort Wayne, IN 46845 USA This is to certify that Applied Industrial Microbiology 2321 South Melrose Drive Vista, CA

More information

Pathogens and Grazing Livestock

Pathogens and Grazing Livestock Pathogens and Grazing Livestock Steve Ensley DVM, PhD 10/16/09 Water Borne Pathogens This presentation will have a specific emphasis on water borne pathogens. NUMBERS OF IOWA WATER SOURCES WITH Stream/River

More information

NordVal International / NMKL c/o Norwegian Veterinary Institute PB 750 Sentrum, 0106 Oslo, Norway

NordVal International / NMKL c/o Norwegian Veterinary Institute PB 750 Sentrum, 0106 Oslo, Norway Issued for: 3M TM Petrifilm TM / Coliform Count Plate NordVal No: 014 First approval date: 5 May 2003 Renewal date: 1 June 2017 Valid until: 1 June 2019 3M TM Petrifilm TM / Coliform Count Plate Manufactured

More information

Productivity. Technician. Maximized. Interpretation Guide

Productivity. Technician. Maximized. Interpretation Guide 3M Food Safety 3M Petrifilm Aqua Heterotrophic Count Plate 3M Petrifilm Aqua Coliform Count Plate Technician Productivity Maximized Interpretation Guide Introducing 3M Petrifilm Aqua Heterotrophic Count

More information

Convenient Media Solutions For food and water testing

Convenient Media Solutions For food and water testing Convenient Media Solutions For food and water testing The life science business of Merck KGaA, Darmstadt, Germany operates as MilliporeSigma in the U.S. and Canada. Convenient Media Solutions Convenient

More information

There are 7 kinds of unique dry medium for hygienic testing and detection of food poisoning bacteria.

There are 7 kinds of unique dry medium for hygienic testing and detection of food poisoning bacteria. Simple and Easy Dry Media for Microbial Count and Detection There are 7 kinds of unique dry medium for hygienic testing and detection of food poisoning bacteria. s Small and compact dry media (sterilized)

More information

Bacterial Quality of Crystalline Rock and Glacial Aquifers in New England

Bacterial Quality of Crystalline Rock and Glacial Aquifers in New England Bacterial Quality of Crystalline Rock and Glacial Aquifers in New England By Sarah Flanagan and Charles Culbertson, U.S. Geological Survey 2012 New Hampshire Water and Watershed Conference Plymouth State

More information

The Mercer Island E. coli Event PNWS AWWA Spring Conference Bellevue Washington 2015

The Mercer Island E. coli Event PNWS AWWA Spring Conference Bellevue Washington 2015 The Mercer Island E. coli Event PNWS AWWA Spring Conference Bellevue Washington 2015 Steve Deem, PE & Bob James, PE Office of Drinking Water Washington State Department of Health Office of Drinking Water

More information

Proficiency Testing FINAL REPORT Check sample program 16CSP02 February 2016

Proficiency Testing FINAL REPORT Check sample program 16CSP02 February 2016 Proficiency Testing FINAL REPORT Check sample program 16CSP2 February 216 Proficiency Testing Provider Certificate Number 3189-2. Program Coordinator: Ingrid Flemming IFM Quality Services Pty Ltd PO Box

More information

Water Quality Trends for Conscience Bay

Water Quality Trends for Conscience Bay Water Quality Trends for Conscience Bay 2018 This report summarizes water quality data for fecal coliform and total coliform in Conscience Bay for the years 1998-2018. Prepared by: Brian M. McCaffrey Stormwater

More information

Pr oject Summar y. Impact of ground beef packaging systems and temperature abuse on the safety of ground beef

Pr oject Summar y. Impact of ground beef packaging systems and temperature abuse on the safety of ground beef Pr oject Summar y Impact of ground beef packaging systems and temperature abuse on the safety of ground beef Principal Investigators: J Chance Brooks, Mindy M. Brashears, Mark F. Miller, and Adam Tittor

More information

Bacterial Occurrence in Kitchen Hand Towels

Bacterial Occurrence in Kitchen Hand Towels PEER-REVIEWED ARTICLE Food Protection Trends, Vol 34, No. 5, p.312-317 Copyright 2014, International Association for Food Protection 6200 Aurora Ave., Suite 200W, Des Moines, IA 50322-2864 Charles P. Gerba,

More information

Finding sources of fecal coliform bacteria in stormwater runoff

Finding sources of fecal coliform bacteria in stormwater runoff Finding sources of fecal coliform bacteria in stormwater runoff David Tomasko, Ph.D. May 12, 2016 Why the concern over bacteria? Cholera Tens of millions killed over the centuries > 100,000 Americans 11

More information

Jonathan Howarth Ph.D and Tina Rodrigues BS Enviro Tech Chemical Services Modesto, CA 95258

Jonathan Howarth Ph.D and Tina Rodrigues BS Enviro Tech Chemical Services Modesto, CA 95258 The Effectiveness of Water, Sodium Hypochlorite Bleach, and Peroxyacetic Acid (PAA) in Eradicating a Wild Field Strain of E. coli O157:H7 from the Surface of Cucumbers Background Jonathan Howarth Ph.D

More information

Microbial Hygiene Considerations with Mechanical Harvesting of Blueberries

Microbial Hygiene Considerations with Mechanical Harvesting of Blueberries Microbial Hygiene Considerations with Mechanical Harvesting of lueberries Renée Allen UGA Extension, Alma, GA Dr. Harald Scherm UGA Plant Pathology, Athens, GA Dr. Jinru Chen UGA Food Science, Griffin,

More information

Portland Water District Sebago Lake Monitoring Programs Lower Bay Bacteria Monitoring Presenting data from 1977 to 2018 Laurel Jackson

Portland Water District Sebago Lake Monitoring Programs Lower Bay Bacteria Monitoring Presenting data from 1977 to 2018 Laurel Jackson Portland Water District Sebago Lake Monitoring Programs Lower Bay Bacteria Monitoring Presenting data from 1977 to 2018 Laurel Jackson Introduction Sebago Lake is the primary drinking water supply for

More information

Learning Styles: Visual, auditory, kinesthetic, and synthesis

Learning Styles: Visual, auditory, kinesthetic, and synthesis Miriam Sawyer Tate High School/ Escambia County, FL Title: Let s get sterile and learn to problem solve!!!! Key Questions: (Unit on safety and scientific method) 1. How well do we wash our hands and why

More information

E. coli and Coliform Bacteria Levels of Edgewood s Watershed Katie Schneider and Leslie Reed

E. coli and Coliform Bacteria Levels of Edgewood s Watershed Katie Schneider and Leslie Reed E. coli and Coliform Bacteria Levels of Edgewood s Watershed Katie Schneider and Leslie Reed Abstract Bacteria levels throughout the Lake Wingra watershed are a concern to the Lake Wingra community. Local

More information

UNITED STATES DEPARTMENT OF AGRICULTURE FOOD SAFETY AND INSPECTION SERVICE WASHINGTON, DC

UNITED STATES DEPARTMENT OF AGRICULTURE FOOD SAFETY AND INSPECTION SERVICE WASHINGTON, DC UNITED STATES DEPARTMENT OF AGRICULTURE FOOD SAFETY AND INSPECTION SERVICE WASHINGTON, DC FSIS NOTICE 05-09 1/7/09 MEASURES TO ADDRESS E. coli O157:H7 AT ESTABLISHMENT THAT RECEIVE, GRIND, OR OTHERWISE

More information

BSc (Hons) Food Science and Technology (Minor: Food Microbiology) (Full-Time)

BSc (Hons) Food Science and Technology (Minor: Food Microbiology) (Full-Time) BSc (Hons) Food Science and Technology (Minor: Food Microbiology) (Full-Time) 1. Objectives The programme is designed to develop the necessary attitude and competence for the application of scientific

More information

CITY OF LYNDEN STORMWATER MANAGEMENT PROGRAM REPORT MARCH 1, 2016

CITY OF LYNDEN STORMWATER MANAGEMENT PROGRAM REPORT MARCH 1, 2016 CITY OF LYNDEN STORMWATER MANAGEMENT PROGRAM 2015 WATER QUALITY MONITORING REPORT CITY OF LYNDEN 300 4 TH STREET LYNDEN, WASHINGTON 98264 PHONE (360) 354-3446 MARCH 1, 2016 This document serves as an attachment

More information

ISPUB.COM. Microbiological Quality Of Sweetmeat With Special Reference To Staphylococci. S Chakraborty, A Pramanik, A Goswami, R Ghosh, S Biswas

ISPUB.COM. Microbiological Quality Of Sweetmeat With Special Reference To Staphylococci. S Chakraborty, A Pramanik, A Goswami, R Ghosh, S Biswas ISPUB.COM The Internet Journal of Microbiology Volume 1 Number 1 Microbiological Quality Of Sweetmeat With Special Reference To Staphylococci S Chakraborty, A Pramanik, A Goswami, R Ghosh, S Biswas Citation

More information

Bacterial Interference with Coliform Colony Sheen Production on

Bacterial Interference with Coliform Colony Sheen Production on APPLIED AND ENVIRONMENTAL MICROBIOLOGY, Jan. 4, p. 56-6 99-2/4/6-5$2./ Copyright 4, American Society for Microbiology Vol., No. 1 Bacterial Interference with Coliform Colony Sheen Pruction on Membrane

More information

Drinking Water Microbiology 2010:2, September

Drinking Water Microbiology 2010:2, September Rapport 2-21 Proficiency Testing Drinking Water Microbiology 21:2, September by Christina Lantz, Tommy Šlapokas and Irina Boriak 2 16 36 E s c h e ric h ia c o li (M F ) No. of results 12 8 4 * 15 3 45

More information

Laboratories & Consulting Group

Laboratories & Consulting Group Final Report Efficacy of Hypobromous Acid as a Hide Intervention Performed July 18-20, 2011 Submitted to Mike Harvey Technical Operations Mgr. Enviro Tech 500 Winmoore Way Modesto, CA 95358 209-232-2211

More information

MICROBIAL ANALYSIS OF RAW AND BOILED MILK SOLD AT BARATON CENTER IN NANDI COUNTY, KENYA

MICROBIAL ANALYSIS OF RAW AND BOILED MILK SOLD AT BARATON CENTER IN NANDI COUNTY, KENYA MICROBIAL ANALYSIS OF RAW AND BOILED MILK SOLD AT BARATON CENTER IN NANDI COUNTY, KENYA Ogot, H. A.*, Ochuodho, H. O., & Machoka, R. University of Eastern Africa, Baraton, P. O. Box 2500-30100, Eldoret,

More information

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation BSK Associates Vancouver

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation BSK Associates Vancouver MATRIX Reference Code Analyte Code Description Drinking EPA 300.0 2.1 10053200 Methods for the Determination of Inorganic Substances in Environmental Samples 1575 Chloride 1730 Fluoride 1810 Nitrate as

More information

NETWORK MANAGER - SISG SAFETY STUDY

NETWORK MANAGER - SISG SAFETY STUDY NETWORK MANAGER - SISG SAFETY STUDY "Runway Incursion Serious Incidents & Accidents - SAFMAP analysis of - data sample" Edition Number Edition Validity Date :. : APRIL 7 Runway Incursion Serious Incidents

More information

IMPACT OF ŠABAC INDUSTRY ON THE ENVIRONMENTAL CONDITION OF THE SAVA RIVER 1

IMPACT OF ŠABAC INDUSTRY ON THE ENVIRONMENTAL CONDITION OF THE SAVA RIVER 1 IMPACT OF ŠABAC INDUSTRY ON THE ENVIRONMENTAL CONDITION OF THE SAVA RIVER 1 Aleksandar Pavić Vera Blagojević High Scool (Gimnazija), Šabac, Yugoslavia ABSTRACT Microbiological, chemical and physico-chemical

More information

Alberta Agriculture and Forestry s Response to the 2014 Outbreak of E. coli O157:H7 in Alberta

Alberta Agriculture and Forestry s Response to the 2014 Outbreak of E. coli O157:H7 in Alberta Alberta Agriculture and Forestry s Response to the 2014 Outbreak of E. coli O157:H7 in Alberta Jeff Stewart Alberta Agriculture and Forestry Industry Days April 9, 2016 E. coli O157:H7: What is it and

More information

Fecal Coliform Bacteria Monitoring for the Sleepy Creek Watershed Incremental 319 Project Final Report

Fecal Coliform Bacteria Monitoring for the Sleepy Creek Watershed Incremental 319 Project Final Report Fecal Coliform Bacteria Monitoring for the Sleepy Creek Watershed Incremental 319 Project Final Report Prepared for: West Virginia Conservation Agency Prepared by: Cacapon Institute Back Creek Road PO

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Certified Laboratories of Northern California

More information

3M Molecular Detection Assay E. coli O157 (including H7) Performance Summary

3M Molecular Detection Assay E. coli O157 (including H7) Performance Summary 3M Food Safety Technical Bulletin Number: TB.171058.02 Effective Date: Feb 15, 2012 Supersedes: TB.171058.01 Technology Platform: Pathogens Originating Location: St. Paul, MN 3M Molecular Detection Assay

More information

The UK s leading supplier of compliance training materials. E.Coli 0157 Guidance

The UK s leading supplier of compliance training materials. E.Coli 0157 Guidance The UK s leading supplier of compliance training materials E.Coli 0157 Guidance A bit about Eschericia Coli Many types of E. coli are harmless. Some types of E. coli can produce toxins (Shiga toxins).

More information

No Longer Fond of the Local Pond

No Longer Fond of the Local Pond No Longer Fond of the Local Pond by Stephanie L. Luster-Teasley, Janie G. Locklear, and Niva S. King Department of Civil, Architectural and Environmental Engineering North Carolina A&T State University,

More information

HOSE ASSEMBLY CLEANLINESS

HOSE ASSEMBLY CLEANLINESS November 18, 2002 HOSE ASSEMBLY CLEANLINESS Preface Hydraulic system cleanliness is a term used to describe the level of solid and liquid contamination found in hydraulic systems. Contamination may be

More information

Investigation of the effect of antibiotics on bacterial growth. Introduction. Apparatus. Diagram of Apparatus

Investigation of the effect of antibiotics on bacterial growth. Introduction. Apparatus. Diagram of Apparatus Investigation of the effect of antibiotics on bacterial growth Introduction Antimicrobials are agents that are able to kill bacteria or halt their growth. They are widely used in medicine to treat bacterial

More information

Adult Diapers. Anti Bacteria Anti Odour Anti Allergy Wetness Indicator Extra Absorbent Leak Proof

Adult Diapers. Anti Bacteria Anti Odour Anti Allergy Wetness Indicator Extra Absorbent Leak Proof Adult Diapers Anti Bacteria Anti Odour Anti Allergy Wetness Indicator Extra Absorbent Leak Proof Face Mask The Face Masks are extensively used by the healthcare staff for facial protection against air

More information

Design of E. coli O157:H7 sampling and testing programs by Industry

Design of E. coli O157:H7 sampling and testing programs by Industry Design of E. coli O157:H7 sampling and testing programs by Industry FSIS EIAO Correlation March 3, 2011 Peter Evans, Ph. D, M.P.H Senior Microbiologist FSIS Office of Public Health Science peter.evans@fsis.usda.gov

More information

Monash University Procedure. Cooling Tower Management Procedure. PROCEDURE STATEMENT

Monash University Procedure. Cooling Tower Management Procedure. PROCEDURE STATEMENT Procedure Title Parent Policy Cooling Tower Management Procedure n/a Date Effective June 2014 Review Date June 2017 Procedure Owner Category Manager, OH&S Operational Version Number 1.1 Content Enquiries

More information

AllPure Technologies

AllPure Technologies AllPure Technologies aseptic tube sealing November 2011 Patent Pending PLEASE READ BEFORE USING THIS PRESENTATION Slides 1 through 10 can be shown to the customer. Slides 13-17 are comparison tables with

More information

9 LABORATORY ACCESSORY

9 LABORATORY ACCESSORY 9 NORMAG - LABORATORY GLASSWARE L 309 e.1 DRYING TUBES They serve for drying of gas with suitable desiccants. To avoid sticking of the packing during the process, not shape resistant desiccants (e.g. phosphorus

More information

Effect of food safety systems on the microbiological quality of beef

Effect of food safety systems on the microbiological quality of beef Effect of food safety systems on the microbiological quality of beef by Papiso Ariette Tshabalala Thesis submitted in partial fulfilment of the requirements for the degree Doctor of Philosophy (PhD) in

More information

Water Quality Trends for Patchogue Bay

Water Quality Trends for Patchogue Bay Water Quality Trends for Patchogue Bay 2018 This report summarizes water quality data for fecal coliform and total coliform in Patchogue Bay for the years 2003-2017. Prepared by: Brian M. McCaffrey Stormwater

More information

A Statistical Method for Eliminating False Counts Due to Debris, Using Automated Visual Inspection for Probe Marks

A Statistical Method for Eliminating False Counts Due to Debris, Using Automated Visual Inspection for Probe Marks A Statistical Method for Eliminating False Counts Due to Debris, Using Automated Visual Inspection for Probe Marks SWTW 2003 Max Guest & Mike Clay August Technology, Plano, TX Probe Debris & Challenges

More information

A Study of the Role of Air-borne Particulates as the Cause of Unexplained Coliform Contamination in Drilled Wells.

A Study of the Role of Air-borne Particulates as the Cause of Unexplained Coliform Contamination in Drilled Wells. A Study of the Role of Air-borne Particulates as the Cause of Unexplained Coliform Contamination in Drilled Wells. Marie T. Trest, Jon H. Standridge, Sharon M. Kluender, and Jeremy M. Olstadt University

More information

Coliform Species Recovered from Untreated Surface Water

Coliform Species Recovered from Untreated Surface Water APPLIED AND ENVIRONMENTAL MICROBIOLOGY, Mar. 1981, p. 657-663 0099-2240/81/030657-07$02.00/0 Vol. 41, No. 3 Coliform Species Recovered from Untreated Surface Water and Drinking Water by the Membrane Filter,

More information

UNITED STATES DEPARTMENT OF AGRICULTURE FOOD SAFETY AND INSPECTION SERVICE WASHINGTON, DC

UNITED STATES DEPARTMENT OF AGRICULTURE FOOD SAFETY AND INSPECTION SERVICE WASHINGTON, DC UNITED STATES DEPARTMENT OF AGRICULTURE FOOD SAFETY AND INSPECTION SERVICE WASHINGTON, DC FSIS TICE 80-08 10/30/08 THIS TICE REISSUES THE CONTENT OF FSIS TICE 68-07 IN ITS ENTIRETY ROUTINE SAMPLING AND

More information