DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing
|
|
- Camilla Fowler
- 5 years ago
- Views:
Transcription
1 Pushbuttons toggle switch 6,35 mm dia. toggle switch 6,35 mm dia. no. of poles material of contacts Switching position connection method colour part no. 2 silver 2 (maintained chromiumplated packaging of 20 pcs. 1 gold 2 (maintained silver 2 (maintained chromiumplated chromiumplated as of page.7, s as of page.10, circuit drawing as of page.11 circuit drawing.1
2 Pushbuttons toggle switch 10 mm dia. toggle switch 10 mm dia. no. of poles front protection material of contacts Switching position 1 IP 67 gold 2 (maintained soldering silver 2 (maintained soldering without gold 2 (maintained soldering silver 2 (maintained soldering 2 IP 67 silver 2 (maintained soldering without gold 2 (maintained soldering silver 2 (maintained soldering connection method colour part no. circuit drawing matt black matt chromiumplated matt chromiumplated chromiumplated chromiumplated matt chromiumplated chromiumplated chromiumplated as of page.7, s as of page.10, circuit drawing as of page.11 pushbutton 6,35 mm dia. pushbutton 6,35 mm dia. packaging of 10 pcs. no. of poles material of contacts contacts connection method colour part no. 1 gold 2(momentary silver 2(momentary chromiumplated matt black chromiumplated circuit drawing as of page.7, s as of page.10, circuit drawing as of page.11.2
3 Pushbuttons pushbutton 10 mm dia. pushbutton 10 mm dia. no. of poles front protection material of contacts contacts 1 IP 67 gold 2(momentary silver 2(momentary without gold 2(momentary 2 IP 67 gold 2(momentary silver 2(momentary without gold 2(momentary silver 2(momentary connection method colour part no. circuit drawing matt black matt chromiumplated matt chromiumplated chromiumplated matt black chromiumplated matt black chromiumplated chromiumplated chromiumplated as of page.7, s as of page.10, circuit drawing as of page.11.3
4 Pushbuttons protective cap for toggle switch 10 mm dia. protective cap for toggle switch 10 mm dia. for type , colour part no. chromiumplated as of page.7 cap for pushbutton 6,35 mm dia. cap for pushbutton 6,35 mm dia. colour part no. black red as of page.7, s as of page.10.4
5 Pushbuttons cap for pushbutton 10 mm dia. cap for pushbutton 10 mm dia. dimension colour part no. Ø 13 mm black red as of page.7, s as of page.10 protective cap for pushbutton 10 mm dia. protective cap for pushbutton 10 mm dia. for type , , colour part no. chromiumplated as of page.7, s as of page.10.5
6 Technical Data electrical characteristics contact resistance <10mΩ current nominal minimum: silver contacts: 50 ma, gold contacts: 100 µa insulation resistance at 500 VDC: > MΩ life time operations switch rating 220 VAC/1,5 A 110 VAC/2,5 A voltage minimum: silver contacts: 10 V gold contacts: 10 mv mechanical characteristics contacts gold contacts: gold/gold plated brass contacts, silver contacts: solid silver/silverplated contacts resistance to shock (IEC 5124) 100 g resistance to vibrations (IEC 5124) 10 to 2000 Hz, 10 cycles, 10 g climatic characteristics damp heat 56 days sealing as per version: to IP 67 service temperature 40 C to + 85 C storage temperature 40 C to + 85 C.6
7 Technical Drawing, Dimension Technical Drawing 1 toggle switch 6,35 mm dia. page.1 2 toggle switch 6,35 mm dia. page.1 3 toggle switch 10 mm dia. page.2 4 toggle switch 10 mm dia. page.2.7
8 Technical Drawing, Dimension 5 toggle switch 10 mm dia. page.2 6 pushbutton 6,35 mm dia. page.2 7 pushbutton 10 mm dia. page.3 8 pushbutton 10 mm dia. page.3 9 pushbutton 10 mm dia. page.3.8
9 Technical Drawing, Dimension 10 pushbutton 10 mm dia. page.3 11 pushbutton 10 mm dia. page.3 12 protective cove for toggle switch 10 mm dia. page.4 13 cap for pushbutton 6,35 mm dia. page.4 14 cap for pushbutton 10 mm dia. page.5.9
10 Technical Drawing, Dimension 15 protective cap for pushbutton 10 mm dia. page.5 Mounting Dimension 1 toggle switch 6,35 mm dia., pushbutton 6,35 mm dia. page.1,.2 2 toggle switch 10 mm dia., pushbutton 10 mm dia. page.2,.3.10
11 Circuit Drawing circuit drawing
Model Number Structure
Solid State Relays Refer to Safety Precautions for All Solid State Relays. Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via
More informationPCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)
PCB Relay Small, Low-Cost 0-A Power Relay for PCB Applications Small, yet capable of switching up to a 0-A loads. Inexpensive. Ideal for home and industrial appliances, HVAC (heating, ventilating, and
More informationData Sheet for Precision Potentiometer
AL(R)17/19 soldering lugs The AL(R)17/19 potentiometers in 22 mm housing are suitable for applications where a precise and economical multiturn potentiometer is important. Economical and precise multiturn
More informationData Sheet for Precision Potentiometer
The ALI(R)17/19 potentiometers in mm housing are suitable for applications where a precise multiturn potentiometer increased radial shaft loads is important. ALI(R)17/19 reinforced bearing ALI(R)17/19
More informationGeneral Purpose High Power PCB Relays
T9 Series Two-pole 3A PCB or Panel Mount Relay n A, form A (NO) and form C (CO) switching capability n Designed to control compressor loads to 3.5 tons, LRA / 5.3FLA n Meets requirements of UL 58 and UL
More information10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC
Solid State Relays G3NE Compact, Low-cost, SSR Switching 5to20 A Wide load voltage range: 75 to 264 VAC. Dedicated, compact aluminum PCB and power elements used. Built-in varistor effectively absorbs external
More informationEmergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction
Emergency Stop Switch Install in 22-dia. or 25-dia. Panel Cutout Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1,. Safety Lock Mechanism prevents misuse.
More informationGeneral-purpose Relay
General-purpose Relay A Miniature Power Relay Equipped with arc barrier. Withstand : 2,000 V. RC+Y LR Ordering Information Open Relays Type Contact form Plug-in/solder terminals Plug-in/solder terminals
More informationType Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder
A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with
More informationDistinctive Characteristics
Distinctive Characteristics Base of heat resistant resin meets ULV-0 flammability rating. Maximized voltage capability of V allows use in medium source applications and increases operating life. Award-winning
More informationMounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B
A High-capacity, High-dielectricstrength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated coil that handles
More informationSystem pro M compact Miniature Circuit Breaker S 200 U and S 200 UP
Data Sheet System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP 2CDC021316F0004 2CDC021320F0004 The S 200 U and S 200 UP ranges are miniature circuit breakers conforming to UL, CS and IEC
More informationSmallest Connector with Removable Contacts
1 Ultra-Miniature 8STA Size 01 Connectors Smallest Connector with Removable Contacts Ultra compact design and very lightweight connector dedicated to the harshest of motorsport environments. Innovative
More informationPlug-in/solder terminals with LED indicator
General-purpose Relay LY Electromechanical Relays A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole
More informationSupplementary protector S 200 MR for ring-tongue applications acc. to UL 1077
Electrical installations in buildings for ring-tongue applications acc. to UL 1077 S 200 MR is a high-performance supplementary protector with ring cable lug connections conforming to UL, CSA, and IEC
More information630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.
SIDERMAT combination 630 to 1800 A sdmat_048_a_1_cat SIDERMAT combination are manually operated tri- or tetrapolar fuse disconnecting switches which can be triggered remotely. They provide breaking and
More informationPower Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops
Power Relay A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated
More informationNH MULTIBLOC fuse-switchdisconnector. terminal version reference no.
NH fuse-switch-disconnector NH fuse-switchdisconnector ~ 690V screw fixing of disconnectors onto plates size rated current in A no. of poles terminal version art. group 00 160 1 screw M8 both sides F229292
More informationYEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W
CV5 Slim 12V Outdoor Converter 5 YEARS IP67 50.000 hrs The perfect partner to team up with any 12V LED solution Full power range from 15W to 200W SLIM profile (40x23mm) to fit in very thin applications
More informationSIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution sdmat_048_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationUniversal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W
isolating General Data Rated input voltage 208 - Rated output voltage 24-230 Vac Rated power 100-3200 VA Insulation class B Maximum ambient temperature 40 C Efficiency up to 96 % Degree of protection IP
More informationDEUTSCH H91 Series Filter Connectors MIL-DTL SERIES I
MIL-DTL-38999 Series I connectors are subminiature, environmental-class connectors with high and mediumdensity insert arrangements. They are used where a quickdisconnect coupling system is required for
More informationYEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W
OCV5 Slim 12V Outdoor Converter 5 YEARS IP67 50.000 hrs The perfect partner to team up with any 12V LED solution Full power range from 15W to 200W SLIM profile (40x23mm) to fit in very thin applications
More informationPushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction
Pushbutton Switch Install in 22-dia. or 25-dia. Panel Cutout Easy mounting and removal of Switch Unit. Increase wiring efficiency with three-row mounting of Switch Unit. Finger protection mechanism on
More informationDefinite Purpose Contactors 1, 2 and 3 pole Type GDP
Definite Purpose Contactors 1, 2 and 3 pole Type l Definite Purpose Contactors l Switching up to 100A resistive, 90A inductive l Line Voltage up to 600VAC on most sizes l Control voltage up to 480VAC l
More informationReferences. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_156_a_2_cat Direct
More informationtttttt www.wealdelectronics.com This publication is issued to provide outline information only and unless specifically agreed to the contrary by WEALD ELECTRONICS LTD. in writing, is not to form part of
More informationAISI 316L PERFORMANCE RANGE INSTALLATION AND USE
CP-ST Stainless steel centrifugal pumps CP-ST4 Pump body: stainless steel AISI 304 Impeller: stainless steel AISI 304 Shaft: stainless steel AISI 431 CP-ST6 Pump body: stainless steel AISI 316L Impeller:
More informationFLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing
FLFE..L FLF..L - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time Ex e terminal board housing Simplified maintenance 4 Joule shock resistant borosilicate glass White painted
More informationLimit Switches. 6.2 E47 Precision Switches
Limit Switches E47BMS02 E47BMS11 E47BMS40.2 Product Description............................................. 2 Approvals..................................................... 2 Features and Benefits...........................................
More informationINSAVER LED. One area endless possibilities. In support of. United Nations Educational, Scientific and Cultural Organization
In support of United Nations Educational, Scientific and Cultural Organization International Year of Light 2015 INSAVER LED Insaver 75 LED 16W LED white downlight Ideal for applications such as reception
More informationOAsys OP0XX, Issue 01, February Outside Plant. Metallic joint closure NXOK 10 units. Features and Benefits
Metallic joint closure NXOK 10 units for OPGWs with steel tubes and for optical cables Prysmian Part Number: See the page no. 3 6 The NXOK 10 joint closure units are designed to be used for jointing optical
More informationFeature. Model comment JG 3NA B L - B - D3
Feature Device type universal nut terminals with safety protective cover -A Power Output Rated load voltage 20VAC/VAC Triac power switch Have DC-AC (DC signal to control the AC load) AC-AC (AC signal to
More informationTest Report: HEP
Test Report: HEP-600-24 600W Single Output Switching Power Supply DESIGN VERIFY TEST Output Function Test Input Function Test Protection Function Test Control Function Test Component Stress Test SAFETY
More informationNK Multi-stage submersible pumps
NK Multi-stage submersible pumps PERFORMANCE RANGE Flow rate up to 120 l/min (7.2 m³/h) Head up to 10 m APPLICATION LIMITS Maximum liquid temperature +40 C Maximum sand content 0 g/m³ 20 m maximum immersion
More informationLSC19 Lighting Cable Assemblies and Connectors
PowerFLEX Cable Assemblies PowerPARTS Wiring Devices ISO 9001:2008 LSC19 Lighting Cable Assemblies and Connectors PowerFLEX and PowerPARTS Introducing a new generation of Lex Products 19 pin, 6-circuit
More informationLOCAL DISCONNECT SWITCHES Manual Motor Controllers
LOCAL DISCONNECT SWITCHES Manual Motor Controllers 1 2 Ensto Manufacturer of electrical components and systems This brochure presents the economical, versatile and reliable Ensto Origin manual motor controllers
More informationProduct Guide LED OBSTRUCTION LIGHTS
Product Guide LED OBSTRUCTION LIGHTS Certified to: FAA AC NO: 150/5345-43F FAA Engineering Brief No. 67 Compliant to: ICAO Annex 14, 4th Edition, July 2004 ICAO Aerodromes Design Manual, Chapter 18 Canadian
More informationAmbient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage
SSR Power Controller SSR 1 SSR 2 SSR 3 Phase Single 2 Leg Switching 3 Phase DIN Rail/Panel Mounting Both Both Both Cooling Fan Optional Optional Optional Control MethodZero Cross Trigger / high isolation
More informationDuroSite LED Floodlight - CE. for Outdoor Industrial Applications #
DuroSite LED Floodlight - CE for Outdoor Industrial Applications # On when it matters most. Products and solutions that protect your business 2 www.dialight.com Dialight_LED_Floodlight_SpecSheet_CE_100-277_VAC
More informationL-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights
L-864 L-865 / L-864 L-810 L-810 Vigilant Series LED Based Obstruction Lights Certified to: FAA AC NO: 150/5345-43F FAA Engineering Brief No. 67 Compliant to: ICAO Annex 14, 4th Edition, July 2004 ICAO
More information6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description
.1 PSG Series Contents Description PSG Series Catalog Number Selection................ Technical Data and Specifications.......... Power Derating Curves.................. Dimensions...........................
More informationSLP. Contents. SLP Ordering Details... 12/2 Technical Data... 12/5 12/1 1SBC R1001
12 Contents SLP Ordering Details... 12/2 Technical Data... 12/5 12/1 Ordering Details Item Description Type Order code Units Per Weight Designation Package Per Unit SLP SLP 100 100A NHP 138902R0005 0,8
More informationSWL Series VALVE REGULATED LEAD-ACID BATTERIES SWL
SWL Series VALVE REGULATED LEAD-ACID BATTERIES SWL SWL VALVE REGULATED LEAD-ACID BATTERIES (VRLA) The SWL range is an enhanced NPL design resulting in an improved energy to density ratio, giving up to
More informationGeneral-Use Auto-Tuning HPX-T Series
General-Use Auto-Tuning HPX-T Series Built-in Hyper-tuning automatically adjusts scanning characteristics. Adjustment steps, results and scanning conditions are digitally displayed by LED. Digital display
More informationSIGNAL. Product Data Sheet. LED Technology. Lighting Facts. Signal 24 AE-024L4-02F-40K. Signal 32 AE-032L3-04F-40K
Signal is an important new addition to the 35 Collection of integrated site elements created in collaboration with frog design. A high-performance light for pedestrian and streetscape lighting, it is innovative
More informationSafeSite LED Stainless Steel Linear - ATEX / IECEx for Indoor and Outdoor Industrial Applications
SafeSite LED Stainless Steel Linear - ATEX / IECEx for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 www.dialight.com Dialight_LED_Stainless_Steel_Linear_Specsheet_AtexIECEx_RevI_Jan2018
More informationPorcelain II - Bold and compact, the Porcelain II works well on its own or in a series, illuminating interiors with soft white light.
porcelain tala Porcelain II - Bold and compact, the Porcelain II works well on its own or in a series, illuminating interiors with soft white light. Porcelain III - The largest of the Porcelain trio, this
More informationAVIONICS MOUNTS Low Profile, All-Axis Vibration Isolators
AVIONICS MOUNTS Low Profile, All-Axis Vibration Isolators Avionics mounts are compact, lightweight vibration isolators that provide excellent vibration protection in all axes. Specially designed for the
More informationModel Number Structure
The reliable choice for Hockey-puck-style Solid State Relays. Available in a wide Range of Currents and Voltage. (5 to 90A, max 660 VAC) All models feature the same compact dimensions to provide a uniform
More informationSafeSite LED Floodlight - ATEX / IECEx. for Outdoor Industrial Applications. 1 MDTEXSSFLX001_B
SafeSite LED Floodlight - ATEX / IECEx for Outdoor Industrial Applications 1 www.dialight.com MDTEXSSFLX001_B On when it matters most. Products and solutions that protect your business 2 www.dialight.com
More informationGrounding Clamp. Pins and Ball-Socket Clamps for Temporary Grounding
Grounding Clamp Pins and Ball-Socket Clamps for Temporary Grounding Pins and Ball-Socket Clamps have been designed to solve several temporary grounding situations, where the physical space or the contact
More informationGlass Door Fittings Glass Door Accessories
Angled striking plate Aluminium stainless steel coloured 981.27.983 Recess striking plate DIN left DIN right Steel nickel plated matt 911.39.285 911.39.28 WC thumbturn cylinder Area of application: For
More informationSERIE SP60 - SP60 SERIES
Schemi elettrici disponibili - Wiring diagrams available Interruttore unipolare Single-pole switch Pag 3 4 Interruttore bipolare luminoso (spia dipendente) Illuminated double-pole switch (dependent light)
More informationFIBER OPTIC CLOSURES
FIBER OPTIC CLOSURES In-line type and dome type - series CLS-I, CLS- IF2X, CLS-D, CLS-DF2X144 and CLS-DF2X240 PACIFIC INTERCONNECTIONS - connecting the world with fiber optics IN-LINE TYPE FIBER OPTIC
More informationEngineering Design Assurance Test Report ( S )
TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424
More informationWaterproof Switches 01
Waterproof Switches SL 9 BMASK 9 SA 9 RMASK 96 SLR 98 9 SWITCHES SL TYPICAL APPLICATIONS Steam cleaners S SPST, momentary or not SPST, illuminated or not DPST, momentary or not DPST, illuminated or not
More informationElectric Smoke Damper Actuators
Bulletin Issue Date May 20, 2004 Electric Smoke Damper Actuators The Modulating Electric Smoke Damper Actuators are oil immersed, spring return, linkage coupled actuator for modulating damper control designed
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. 480W Single Output Industrial DIN RAIL with FC Function SECIFICATION MODEL
More informationParts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:
7-1 Section 7 Using the Illustrated List The parts lists provided in this section are organized into the following columns: Item Identifies illustrated parts that are available from Nordson Corporation.
More informationMAIN SWITCHES, CONTROL SWITCHES, COMMAND AND SIGNALLING DEVICES
W COMMAND SERIES MM GENERAL INFORMATION SERIES MM Actuating Betätigungs- and und signalling Signalisierungselemente elements M20x1,5 Ø29,7 Ø29,5 29,7 Full LED technology 100,000 h service life 3 LEDs for
More informationEngineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax
TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424
More informationEngineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:
TEST EQUIPMENT LIST: INPUT FUNCTION TEST AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy
More informationProduct Specification
HDBNC-BH1 Jack, Right Angle Orientation, PCB Terminated HDBNC-CA Plug, Straight Orientation, Cable Terminated Other configurations available for: Vertical cable-to-board applications Through-hole, edge
More informationEngineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:
TEST EQUIPMENT LIST: INPUT FUNCTION TEST AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy
More informationULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES
ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES UPS MIL-SPEC COMPLIANT 1-5 KVA 1-5 U UNIVERSAL 120/240 VAC PFC INPUT SNMP COMMUNICATIONS WHEN EVERY POUND COUNTS! APPLICATIONS Shelters Tactical Systems Shipboard
More informationParts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:
7-1 Section 7 Using the Illustrated List The parts lists provided in this section are organized into the following columns: Item Identifies illustrated parts that are available from Nordson Corporation.
More informationABB Kabeldon. Laboratory Report. Mechanical test of Service Distribution Cabinets, SDC and SDCM
Title: Mechanical test of Service Distribution Cabinets, SDC and SDCM Date: 2004-06-16 Page 1 of 29 Reference: Author: Approved by: Bertil T Larsson Claes H Söderström Report No.: 1141 Distribution: Summary
More informationEmergency Stop Devices
New! Selection and Application of.. 278 Emergency Stop Rope Pull Switches........... 279 New! Emergency Stop Push Buttons............... 293 Banner Engineering Corp. Minneapolis, MN U.S.A. bannerengineering.com
More informationDuroSite LED Bulkhead / Wallpack - CE / UL. for Indoor and Outdoor Industrial Applications
for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 www.dialight.com Dialight_LED_Wallpack_Bulkhead_Specsheet_Industrial_Jan2018
More informationPallet Feet & Fittings SQUARE
SQUARE 1410 Thickness: 2.3 Weight (Kg/100): 25 Post size(mm): 40 per ft (Tonne): 2.46 PALLET FOOT 89MM SQUARE X 2.3 mm THICK 0138 Thickness: 2.3 Weight (Kg/100): 50 per ft (Tonne): 2.19 PALLET FOOT 127MM
More informationCEELOK FAS-T CONNECTORS
CEELOK FAS-T CONNECTORS Small Form Factor, Field Terminable Connectors CeeLok FAS-T connectors ofer a small form factor, ield terminable I/O connector capable of 0 Gb/s Ethernet. Crimpsnap contacts enable
More informationConservatory awning W8 Description
1 3 4 Application Large-area external sun shading system for shading glazed conservatories, patio roofs and pergolas with flat pitch roofs. Function principle: tensioning system via toothed belt with steel
More informationE2 Motors and Motor Starting. #1 Fan Motors
E2 Motors and Motor Starting #1 Fan Motors Basic Electric Motor Stator Stationary electromagnet Rotor Rotating magnet Movement of the rotor Rotates by repulsion and attraction of stator 2005 Refrigeration
More informationEngineering Design Assurance Test Report ( S )
TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424
More informationHome Improvement Fittings Wardrobe Fittings
Wardrobe rail Wardrobe rail, welded Finish: Chrome plated Material thickness: 0.8 1.5 mm Height: 30 mm Material thickness 0.8 mm 801.03.220 1.0 mm 801.13.220 1.2 mm 801.10.229 1.5 mm 801.09.22 Packing:
More informationSPECIAL-TWEEZERS FOR THE SMD-TECHNIQUE
SPECIAL-TWEEZERS FOR THE SMD-TECHNIQUE high precision tweezers from special steel stainless matt finish anti magnetic acid resisting - alternative with ESD coating (-13) - Finish Weight 5-049 110 4 3 /8''
More informationMX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)
MX40-6043 Series MX40-7XXX Series MX40-6XXX Series Selection Guide Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional control from a DDC system
More informationPGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI
PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI INTRODUCTION The LineGard 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore
More informationTable and Furniture Base Fittings Furniture Feets
Aluminium base plate Material: Steel screw Finish: Screw galvanized Installation: With M8 screw Aluminium 14 634.50.465 Accessories Aluminium 634.50.460 Packing: 20 pcs. Aluminium 634.50.469 Packing: 20
More informationJameco SKU Number:
Jameco SKU Number: 2105560 SECIFICATION MODEL OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED OWER LINE REGULATION LOAD REGULATION HOLD U
More informationSurge-Trap Pluggable STPT2 Series - 40kA
EDS1249-001 Surge-TraEDp Pluggable STPT2 Series - 40kA Surge-Trap Pluggable STPT2 Series - 40kA SURGE PROTECTION FOR POWER LINES DIN-RAIL IEC TYPE 2 / CLASS II FEATURES & BENEFITS Maximum discharge current
More informationFastLine. Contents. FastLine Description... 14/2 Ordering Details... 14/3 Technical Data... 14/7 14/1 1SBC R1001
14 Contents FastLine Description... 14/2 Ordering Details... 14/3 Technical Data... 14/7 14/1 Description FS / FST : IP 20 Busbar - assembly plate system FS : 400-1200 A Width : 150-1000 mm FST : 1200-2500
More informationTest Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST
Test Report 240W Single Switching ower Supply DESIGN VERIFY TEST Function Test Input Function Test rotection Function Test Other Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C. Test
More informationElectronic Temperature Controls
ETR-9090 series ETR-9200 series Figure 324 Figure 325 80-260 vac /60Hz PID auto tune/ or 1 set point 3 3 / 8 " depth 1 optional alarm Model Sensor type Output action Alarm ETR9090-121 any thermocouple
More informationOperational Unit. Number of Positions: 2 Positions/3 Positions. Applicable Colors. Non-illuminated: Black Illuminated: Red, green, yellow, blue
Complete Assemblies Knob-type Selector Switch Install in 22-mm dia. or 25-mm dia. Panel Cutout H Illuminated and Non-illuminated models H Locking lever ensures easy mounting and removal of switch unit
More informationSurge-Trap Pluggable STPT12 Series kA
EDS1250-001 Surge-Trap Pluggable STPT12 Series - 12.5kA Surge-Trap Pluggable STPT12 Series - 12.5kA SURGE PROTECTION FOR POWER LINES DIN-RAIL IEC TYPE 1+2 / CLASS I+II FEATURES & BENEFITS Lightning impulse
More informationSafety and process lock Knox
Safety and process lock is a robust lock in stainless steel available in a variety of models: process locks and safety locks, and for most types of doors. All models offer an interlocking function reaching
More informationElectrical Specifications. Dimensions (inches)
Page 7203 Electrical Specifications Valve Position Control 0.1 angular degree resolution Flow Control ± 1% of flow reading over a turndown of 20: 1 ir/fuel Ratio Control ± 2% with turndown of 20: 1 Power
More informationTrapped Key Transfer System SHGV SVM SVE
Trapped Key Transfer System SHGV SVM SVE Description Area of application Cost Savings The SHGV key transfer system occurs mainly in more complex manufacturing systems and equipment. It is especially suitable
More informationTest Report: EDR-75-12
Test Report: EDR-75-12 75W Single Output Industrial DIN RAIL DESIGN VERIFY TEST Output Function Test Input Function Test rotection Function Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C.
More informationElectrical Specifications. Dimensions (inches)
Page 7203 Electrical Specifications Valve Position Control 0.1 angular degree resolution Flow Control ± 1% of flow reading over a turndown of 20: 1 ir/fuel Ratio Control ± 2% with turndown of 20: 1 Power
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. 60W Single Output Industrial DIN Rail ower Supply DR-60 s e ries SECIFICATION
More informationTest Report: APC
Test Report: AC-25-500 25W Single Output Switching ower Supply DESIGN VERIFY TEST Output Function Test Input Function Test rotection Function Test Component Stress Test SAFETY & E.M.C. TEST Safety Test
More informationPilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)
(general purpose valve) ADK11/ADK12 Series NC (normally closed) type, NO (normally open) type Port size: Rc1/4 to Rc1 Diaphragm structure Excluding ADK12 JIS symbol ADK11: NC (normally closed) type OUT
More information20W Single Output Industrial DIN Rail Power Supply MODEL:MDR OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT
20W Single Outut Industrial DIN Rail Power Suly MODEL:MDR-20-12 OUTPUT FUNCTION TEST 1 RIPPLE & NOISE V1: 120 mv- (Max ) I/P: 230VAC V1: 19 mv- (Max ) 2 OUTPUT VOLTAGE CH1: 10.8 V~ 13.2 V 10.21 V~ 13.85
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches TL4024 Safety Interlock Switch with uard Door Locking High locking force of 1,500 N (7 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure withstands
More informationHEATER POWER CONTROLLER
HEATER POWER CONTROLLER /04 Rev 0 - - ii PROCON MODEL HPC TABLE OF CONTENTS DESCRIPTION... MANUAL REVISIONS... 5 WARRANTY... 5 SPECIFICATIONS... 6 DRAWINGS PHYSICAL DIMENSIONS 44-090095-0-00... 7 PANEL
More informationTherme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions
Therme storage water heater Table of contents Symbols used... 8 Installation instructions Water supply... 9 Choice of location... 9 Installation of the Therme... 9 Fitting the draining and venting valve...
More informationELECTRICAL PROPERTIES PVC FILLER NOMINAL VOLTAGE 0,6/1 kv CLOURS CORES CLOURS
STANDART PRODUCT CODE TS IEC 60502-1 / IEC 60502 / VDE 0276-603 COPPER CLASS 1&2 PVC INSULATION NYRY 0,6/1kV 0.6/1 kv PVC insulated steel wire armoured multi-core cables with copper ELECTRICAL PROPERTIES
More information