Pushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Pushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction"

Transcription

1 Pushbutton Switch Install in 22-dia. or 25-dia. Panel Cutout Easy mounting and removal of Switch Unit. Increase wiring efficiency with three-row mounting of Switch Unit. Finger protection mechanism on Switch Unit provided as a standard feature. Use 25-dia. ring to install in 25-dia. panel cutouts. Install using either round, forked crimp terminals, or ferrules. Wide range of shapes and colors. IP65 oil resistance ( models) EN c This product was manufactured at OMRON Izumo. OMRON Izumo has obtained approvals from international certification bodies for its quality system and environmental control system. Ordering Information Construction Lock Fitting Operational Unit Available Colors : Red, green, yellow, white, blue, black Lighted: Red, green yellow, white, blue Lamp Light Source LED Lamp Incandescent Lamp The above illustration shows a lighted model. Switch Unit Contacts SPST-NO,, SPST-NO +, DPST-NO, DPST-NC Lighting Method Lighted (without transformer) Lighted (with transformer) Refer to the pages 48 to 64 for specifications, accessories, installation, and precautions. 1

2 Model Number Legend (Completely Assembled) Shipped as a set which includes the Operational Unit, LED (lighted only), and Switch Unit Lighted/ None L Lighted 2 Flange Shape F Round/Flat T Round/Projection G Round/Full-guard H Round/Half-guard C Square/Projection D Square/Full-guard S Round/Mushroom (30-dia. head) M Round/Mushroom (40-dia. head) Lighted T Round/Projection G Round/Full-guard H Round/Half-guard C Square/Projection D Square/Full-guard 3 Illumination Color R Red G Green Y Yellow W White A Blue B Black (for non-lighted only) 4 Light Source Without Transformer Code Rated Voltage 6D LED 6 VDC 6A 6 VAC 12A 12 VAC/DC 24A 24 VAC/DC With Transformer T1 LED 110 VAC *1 T2 220 VAC *2 Note: The LED lamp (24 VAC/DC) can be lit by directly applying 110 VAC/DC (220 VAC/DC) to the lamp terminal. LED incorporates the 24-VAC/DC. 5 Contacts 10 SPST-NO SPST-NO + 20 DPST-NO 02 DPST-NC Note: Refer to page 48 for contact ratings. 6 Switch Action M Momentary A Latching *1) Operational voltage: 95 to 115 VAC *2) Operational voltage: 190 to 230 VAC Pushbutton Switch (Completely Assembled) (Round Type) Appearance Output Momentary operation y e Illumination color Flat SPST-NO -F -10M -F -10A Insert one of the -F -01M -F -01A following letters into the SPST-NO + -F -11M -F -11A R (red) -F DPST-NO -F -20M -F -20A Y (yellow) DPST-NC -F -02M -F -02A Round/Projection ojec o SPST-NO -T -10M -T -10A -T -01M -T -01A B (black) SPST-NO + -T -11M -T -11A -T DPST-NO -T -20M -T -20A DPST-NC -T -02M -T -02A Round/Full-guard u d SPST-NO -G -10M -G -10A -G -01M -G -01A SPST-NO + -G -11M -G -11A -G DPST-NO -G -20M -G -20A DPST-NC -G -02M -G -02A 2

3 Appearance Output Momentary operation Illumination color Round/Half-guard d SPST-NO -H -10M -H -10A Insert one of the -H -01M -H -01A following letters into the SPST-NO + -H -11M -H -11A R (red) DPST-NO -H -20M -H -20A Y (yellow) -H DPST-NC -H -02M -H -02A Small-size Mushroom SPST-NO -S -10M -S -10A (30-dia. head) -S -01M -S -01A B (black) Medium-size Mushroom (40-dia head) SPST-NO + -S -11M -S -11A DPST-NO -S -20M -S -20A -S DPST-NC -S -02M -S -02A -M (Square Type) SPST-NO -M -10M -M -10A -M -01M -M -01A SPST-NO + -M -11M -M -11A DPST-NO -M -20M -M -20A DPST-NC -M -02M -M -02A Appearance Output Momentary operation (self-reset) Illumination color Square/Projection o SPST-NO -C -10M -C -10A Insert one of the -C -01M -C -01A following letters into the SPST-NO + -C -11M -C -11A R (red) DPST-NO -C -20M -C -20A -C Y (yellow) DPST-NC -C -02M -C -02A Square/Guard SPST-NO -D -10M -D -10A -D -01M -D -01A B (black) -D Lighted (Round Type) SPST-NO + -D -11M -D -11A DPST-NO -D -20M -D -20A DPST-NC -D -02M -D -02A Appearance Output Lighting Rated voltage Momentary operation Illumination color Round/Projection ojec o LED 6 VDC L-T -6D-10M L-T -6D-10A Insert one of 6 VAC L-T -6A-10M L-T -6A-10A the following letters into the LED lighting 12 VAC/DC L-T -12A-10M L-T -12A-10A (Without transformer) 24 VAC/DC L-T -24A-10M L-T -24A-10A R (red) S 6 VDC L-T -6D-01M L-T -6D-01A Y (yellow) 6 VAC L-T -6A-01M L-T -6A-01A 12 VAC/DC L-T -12A-01M L-T -12A-01A L-T 24 VAC/DC L-T -24A-01M L-T -24A-01A + 6 VDC L-T -6D-11M L-T -6D-11A 6 VAC L-T -6A-11M L-T -6A-11A 12 VAC/DC L-T -12A-11M L-T -12A-11A 24 VAC/DC L-T -24A-11M L-T -24A-11A DPST-NO 6 VDC L-T -6D-20M L-T -6D-20A 6 VAC L-T -6A-20M L-T -6A-20A 12 VAC/DC L-T -12A-20M L-T -12A-20A 24 VAC/DC L-T -24A-20M L-T -24A-20A DPST-NC 6 VDC L-T -6D-02M L-T -6D-02A 6 VAC L-T -6A-02M L-T -6A-02A 12 VAC/DC L-T -12A-02M L-T -12A-02A 24 VAC/DC L-T -24A-02M L-T -24A-02A 3

4 Appearance Round/Projection ojec o LED transformer lighting (With transformer) L-T Output Lighting Rated voltage Momentary operation Illumination color LED 110 VAC L-T -T1-10M L-T -T1-10A Insert one of 220 VAC L-T -T2-10M L-T -T2-10A the following letters into the S 110 VAC L-T -T1-01M L-T -T1-01A 220 VAC L-T -T2-01M L-T -T2-01A R (red) VAC L-T -T1-11M L-T -T1-11A Y (yellow) 220 VAC L-T -T2-11M L-T -T2-11A DPST-NO 110 VAC L-T -T1-20M L-T -T1-20A 220 VAC L-T -T2-20M L-T -T2-20A DPST-NC 110 VAC L-T -T1-02M L-T -T1-02A 220 VAC L-T -T2-02M L-T -T2-02A Round/Half-guard d 6 VDC L-H -6D-10M L-H -6D-10A 6 VAC L-H -6A-10M L-H -6A-10A LED lighting 12 VAC/DC L-H -12A-10M L-H -12A-10A (Without transformer) 24 VAC/DC L-H -24A-10M L-H -24A-10A S 6 VDC L-H -6D-01M L-H -6D-01A 6 VAC L-H -6A-01M L-H -6A-01A 12 VAC/DC L-H -12A-01M L-H -12A-01A L-H 24 VAC/DC L-H -24A-01M L-H -24A-01A + 6 VDC L-H -6D-11M L-H -6D-11A 6 VAC L-H -6A-11M L-H -6A-11A 12 VAC/DC L-H -12A-11M L-H -12A-11A 24 VAC/DC L-H -24A-11M L-H -24A-11A DPST-NO 6 VDC L-H -6D-20M L-H -6D-20A 6 VAC L-H -6A-20M L-H -6A-20A 12 VAC/DC L-H -12A-20M L-H -12A-20A 24 VAC/DC L-H -24A-20M L-H -24A-20A DPST-NC 6 VDC L-H -6D-02M L-H -6D-02A 6 VAC L-H -6A-02M L-H -6A-02A 12 VAC/DC L-H -12A-02M L-H -12A-02A 24 VAC/DC L-H -24A-02M L-H -24A-02A 4

5 Appearance Output Lighting Rated voltage Momentary operation Illumination color Round/Half-guard d LED 110 VAC L-H -T1-10M L-H -T1-10A Insert one of 220 VAC L-H -T2-10M L-H -T2-10A the following letters into the LED transformer S 110 VAC L-H -T1-01M L-H -T1-01A lighting (With transformer) 220 VAC L-H -T2-01M L-H -T2-01A R (red) VAC L-H -T1-11M L-H -T1-11A Y (yellow) 220 VAC L-H -T2-11M L-H -T2-11A DPST-NO 110 VAC L-H -T1-20M L-H -T1-20A L-H 220 VAC L-H -T2-20M L-H -T2-20A DPST-NC 110 VAC L-H -T1-02M L-H -T1-02A 220 VAC L-H -T2-02M L-H -T2-02A Round/Full-guard u d 6 VDC L-G -6D-10M L-G -6D-10A 6 VAC L-G -6A-10M L-G -6A-10A LED lighting 12 VAC/DC L-G -12A-10M L-G -12A-10A (Without transformer) 24 VAC/DC L-G -24A-10M L-G -24A-10A S 6 VDC L-G -6D-01M L-G -6D-01A L-G Round/Full-guard u d LED transformer lighting (With transformer) L-G + 6 VAC L-G -6A-01M L-G -6A-01A 12 VAC/DC L-G -12A-01M L-G -12A-01A 24 VAC/DC L-G -24A-01M L-G -24A-01A 6 VDC L-G -6D-11M L-G -6D-11A 6 VAC L-G -6A-11M L-G -6A-11A 12 VAC/DC L-G -12A-11M L-G -12A-11A 24 VAC/DC L-G -24A-11M L-G -24A-11A DPST-NO 6 VDC L-G -6D-20M L-G -6D-20A 6 VAC L-G -6A-20M L-G -6A-20A 12 VAC/DC L-G -12A-20M L-G -12A-20A 24 VAC/DC L-G -24A-20M L-G -24A-20A DPST-NC 6 VDC L-G -6D-02M L-G -6D-02A 6 VAC L-G -6A-02M L-G -6A-02A 12 VAC/DC L-G -12A-02M L-G -12A-02A 24 VAC/DC L-G -24A-02M L-G -24A-02A 110 VAC L-G -T1-10M L-G -T1-10A 220 VAC L-G -T2-10M L-G -T2-10A S 110 VAC L-G -T1-01M L-G -T1-01A VAC L-G -T2-01M L-G -T2-01A 110 VAC L-G -T1-11M L-G -T1-11A 220 VAC L-G -T2-11M L-G -T2-11A DPST-NO 110 VAC L-G -T1-20M L-G -T1-20A 220 VAC L-G -T2-20M L-G -T2-20A DPST-NC 110 VAC L-G -T1-02M L-G -T1-02A 220 VAC L-G -T2-02M L-G -T2-02A 5

6 Lighted (Square Type) Appearance Output Lighting Rated voltage Momentary operation Illumination color Square/Projection o LED 6 VDC L-C -6D-10M L-C -6D-10A Insert one of 6 VAC L-C -6A-10M L-C -6A-10A the following letters into the LED lighting 12 VAC/DC L-C -12A-10M L-C -12A-10A (Without transformer) 24 VAC/DC L-C -24A-10M L-C -24A-10A R (red) S 6 VDC L-C -6D-01M L-C -6D-01A Y (yellow) 6 VAC L-C -6A-01M L-C -6A-01A 12 VAC/DC L-C -12A-01M L-C -12A-01A L-C 24 VAC/DC L-C -24A-01M L-C -24A-01A + 6 VDC L-C -6D-11M L-C -6D-11A 6 VAC L-C -6A-11M L-C -6A-11A 12 VAC/DC L-C -12A-11M L-C -12A-11A 24 VAC/DC L-C -24A-11M L-C -24A-11A DPST-NO 6 VDC L-C -6D-20M L-C -6D-20A 6 VAC L-C -6A-20M L-C -6A-20A 12 VAC/DC L-C -12A-20M L-C -12A-20A 24 VAC/DC L-C -24A-20M L-C -24A-20A DPST-NC 6 VDC L-C -6D-02M L-C -6D-02A 6 VAC L-C -6A-02M L-C -6A-02A 12 VAC/DC L-C -12A-02M L-C -12A-02A 24 VAC/DC L-C -24A-02M L-C -24A-02A Square/Projection o 110 VAC L-C -T1-10M L-C -T1-10A 220 VAC L-C -T2-10M L-C -T2-10A LED transformer S 110 VAC L-C -T1-01M L-C -T1-01A lighting (With transformer) 220 VAC L-C -T2-01M L-C -T2-01A VAC L-C -T1-11M L-C -T1-11A 220 VAC L-C -T2-11M L-C -T2-11A L-C DPST-NO 110 VAC L-C -T1-20M L-C -T1-20A 220 VAC L-C -T2-20M L-C -T2-20A DPST-NC 110 VAC L-C -T1-02M L-C -T1-02A 220 VAC L-C -T2-02M L-C -T2-02A 6

7 Appearance Output Lighting Rated voltage Momentary operation Illumination color Square/Full-guard u LED 6 VDC L-D -6D-10M L-D -6D-10A Insert one of 6 VAC L-D -6A-10M L-D -6A-10A the following letters into the LED lighting 12 VAC/DC L-D -12A-10M L-D -12A-10A (Without transformer) 24 VAC/DC L-D -24A-10M L-D -24A-10A R (red) S 6 VDC L-D -6D-01M L-D -6D-01A Y (yellow) 6 VAC L-D -6A-01M L-D -6A-01A 12 VAC/DC L-D -12A-01M L-D -12A-01A L-D 24 VAC/DC L-D -24A-01M L-D -24A-01A + 6 VDC L-D -6D-11M L-D -6D-11A 6 VAC L-D -6A-11M L-D -6A-11A 12 VAC/DC L-D -12A-11M L-D -12A-11A 24 VAC/DC L-D -24A-11M L-D -24A-11A DPST-NO 6 VDC L-D -6D-20M L-D -6D-20A 6 VAC L-D -6A-20M L-D -6A-20A 12 VAC/DC L-D -12A-20M L-D -12A-20A 24 VAC/DC L-D -24A-20M L-D -24A-20A DPST-NC 6 VDC L-D -6D-02M L-D -6D-02A 6 VAC L-D -6A-02M L-D -6A-02A 12 VAC/DC L-D -12A-02M L-D -12A-02A 24 VAC/DC L-D -24A-02M L-D -24A-02A Square/Full-guard u 110 VAC L-D -T1-10M L-D -T1-10A 220 VAC L-D -T2-10M L-D -T2-10A LED transformer lighting S 110 VAC L-D -T1-01M L-D -T1-01A (With transformer) 220 VAC L-D -T2-01M L-D -T2-01A VAC L-D -T1-11M L-D -T1-11A 220 VAC L-D -T2-11M L-D -T2-11A L-D DPST-NO 110 VAC L-D -T1-20M L-D -T1-20A 220 VAC L-D -T2-20M L-D -T2-20A DPST-NC 110 VAC L-D -T1-02M L-D -T1-02A 220 VAC L-D -T2-02M L-D -T2-02A 7

8 Model Number Legend (Subassembly) The Operational Unit, Lamp, or Switch Unit can be ordered separately. Use them in combination for models that are not available as assembled units. These can also be used as inventory for maintenance parts. Unit Combinations Operational Unit Switch Unit Lighted (without transformer) Operational Unit Lamp LED Incandescent Switch Unit (without transformer) Lighted (with transformer) Operational Unit Lamp LED Switch Unit (with transformer) 1. Operational Unit Lighted/ None L Lighted 2 Flange Shape F Round/Flat T Round/Projection G Round/Full-guard H Round/Half-guard C Square/Projection D Square/Full-guard S Round/Mushroom (30-dia. head) M Round/Mushroom (40-dia. head) Lighted T Round/Projection G Round/Full-guard H Round/Half-guard C Square/Projection D Square/Full-guard 3 Illumination Color R Red G Green Y Yellow W White A Blue B Black (for non-lighted only) 8

9 2. Lamp (Common Use) Operating Voltage (Rated Voltage) Incandescent 5 5 VAC (6 VAC) VAC (14 VAC) VAC (28 VAC) H1 100 VAC (130 VAC) LED 6D 6 VDC (6 VDC) 6A 6 VAC (6 VAC) 12A 12 VAC/DC (12 VAC/DC) 24A 24 VAC/DC (24 VAC/DC) 2 Illumination Color None Incandescent lamp R Red G Green Y Yellow A Blue 3. Switch Unit (General-purpose Load) Lighted/ None L Lighted 2 Contacts 10 SPST-NO SPST-NO + 20 DPST-NO 02 DPST-NC 3 Switch Action M Momentary A Latching 4 Transformer (Lighted Type Only) None Without transformer T1 110 VAC *1 T2 220 VAC *2 *1) Operational voltage: 95 to 115 VAC *2) Operational voltage: 190 to 230 VAC 9

10 Pushbutton Switches (Subassembly) Operational Unit Color o of Operational a Unit IP65 oil-resistant models Flat Projection Full-guard Half-guard Red -FR -TR -GR -HR Green -FG -TG -GG -HG Yellow -FY -TY -GY -HY White -FW -TW -GW -HW Blue -FA -TA -GA -HA Black -FB -TB -GB -HB Color o of Operational a Unit IP65 oil-resistant models Square/Projection Square/Full-guard Round/Mushroom (30-dia. head) Round/Mushroom (40-dia. head) Red -CR -DR -SR -MR Green -CG -DG -SG -MG Yellow -CY -DY -SY -MY White -CW -DW -SW -MW Blue -CA -DA -SA -MA Black -CB -DB -SB -MB Lighted Color o of Operational a Unit IP65 Projection Full-guard Half-guard Red L-TR L-GR L-HR Green L-TG L-GG L-HG Yellow L-TY L-GY L-HY White L-TW L-GW L-HW Blue L-TA L-GA L-HA Note: Common to incandescent lamps and LEDs. Color o of Operational a Unit Square/Projection IP65 Square/Full-guard Red L-CR L-DR Green L-CG L-DG Yellow L-CY L-DY White L-CW L-DW Blue L-CA L-DA 10

11 Lamps LED Rated voltage 6 VDC 6 VAC 12 VAC/DC 24 VAC/DC LED light Red -6DR -6AR -12AR -24AR Green -6DG -6AG -12AG -24AG Yellow (see note 2) -6DY -6AY -12AY -24AY Blue -6DA -6AA -12AA -24AA Note: 1. For transformer lighting, use the -24A. 2. Used when the Operational Unit color is yellow or white. Incandescent Rated voltage 6 VAC 14 VAC 28 VAC 130 VAC H1 Switch Unit (General-purpose Load) Switch action Contacts Model Momentary SPST-NO -10M SPST-NO + DPST-NO DPST-NC -01M -11M -20M -02M Latching ac SPST-NO -10A Lighted SPST-NO + DPST-NO DPST-NC -01A -11A -20A -02A Switch Action Contacts Transformer circuits Without transformer With transformer 110 VAC 220 VAC Momentary SPST-NO L-10M L-10M-T1 L-10M-T2 L-01M L-01M-T1 L-01M-T2 SPST-NO + L-11M L-11M-T1 L-11M-T2 DPST-NO L-20M L-20M-T1 L-20M-T2 DPST-NC L-02M L-02M-T1 L-02M-T2 Latching ac SPST-NO L-10A L-10A-T1 L-10A-T2 L-01A L-01A-T1 L-01A-T2 SPST-NO + L-11A L-11A-T1 L-11A-T2 DPST-NO L-20A L-20A-T1 L-20A-T2 DPST-NC L-02A L-02A-T1 L-02A-T2 11

12 Dimensions Note: 1. All units are in millimeters unless otherwise indicated. 2. The following illustrations are for momentary operation. Lighted/ Pushbutton Switches Flat Type -F For SPST-NO () Switches For DPST-NO (DPST-NC) Monoblock-contact Switches 29.7 dia dia. (see note 1) Half-guard Type -H, L-H Projection Type -T, L-T 29.7 dia dia. Full-guard Type -G, L-G 40-dia. Mushroom Type -M 29.7 dia. 40 dia. Square/Projection Type -C, L-C Square Full-guard Type -D, L-D 29.8 x x x 29.8 Note: 1. models are 9.2 mm longer. 2. Lighted models have the same dimensions as shown above, whether they are with transformers or without transformers. 12

13 Terminal Arrangement Terminal Arrangement (Bottom View) (SPST-NO + ) Lighted (SPST-NO + ) (DPST-NO + DPST-NC) Contact Blocks Contact Blocks Lamp Socket Contact Blocks Terminal Connection Type (SPST-NO + ) Terminal connection Bottom view Panel Cutout Dimensions dia dia. (DPST-NO + DPST-NC) Bottom view Note: When applying coating such as paint to the panel, the dimensions should be those after the application of coating. Lock fitting is provided as a standard item. Lighted without transformer (SPST-NO + ) Bottom view Lighted with transformer (SPST-NO + ) Bottom view ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by To convert grams into ounces, multiply by

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B A High-capacity, High-dielectricstrength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated coil that handles

More information

Plug-in/solder terminals with LED indicator

Plug-in/solder terminals with LED indicator General-purpose Relay LY Electromechanical Relays A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole

More information

General-purpose Relay

General-purpose Relay General-purpose Relay A Miniature Power Relay Equipped with arc barrier. Withstand : 2,000 V. RC+Y LR Ordering Information Open Relays Type Contact form Plug-in/solder terminals Plug-in/solder terminals

More information

Trapped Key Transfer System SHGV SVM SVE

Trapped Key Transfer System SHGV SVM SVE Trapped Key Transfer System SHGV SVM SVE Description Area of application Cost Savings The SHGV key transfer system occurs mainly in more complex manufacturing systems and equipment. It is especially suitable

More information

Electronic Temperature Controls

Electronic Temperature Controls ETR-9090 series ETR-9200 series Figure 324 Figure 325 80-260 vac /60Hz PID auto tune/ or 1 set point 3 3 / 8 " depth 1 optional alarm Model Sensor type Output action Alarm ETR9090-121 any thermocouple

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Safety Interlock Switches TL4024 Safety Interlock Switch with uard Door Locking High locking force of 1,500 N (7 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure withstands

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-5480 www.cmafh.com Safety Interlock Switches TL19 Safety Interlock Switch with uard Door Locking High

More information

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1 Parts B - Section B Parts. Introduction To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use the parts list, and the accompanying illustration, to describe

More information

Parts Catalog T7/T71/T73 M40000/M40001/M40003

Parts Catalog T7/T71/T73 M40000/M40001/M40003 T7/T71/T73 M40000/M40001/M40003 REPAIR PARTS CATALOG NO. M30202(R) For Machines with Serial No. T6183-T9031 ISSUED July 2009 ORDERS Please use Part Numbers when ordering and include the the machine Serial

More information

Parts Catalog T7/T71/T73 M40000/M40001/M40003

Parts Catalog T7/T71/T73 M40000/M40001/M40003 T7/T71/T73 M40000/M40001/M40003 REPAIR PARTS CATALOG NO. For machines starting with Serial No. T10001 ISSUED August 2010 ORDERS Please use Part Numbers when ordering and include the machine Serial Number

More information

Smallest Connector with Removable Contacts

Smallest Connector with Removable Contacts 1 Ultra-Miniature 8STA Size 01 Connectors Smallest Connector with Removable Contacts Ultra compact design and very lightweight connector dedicated to the harshest of motorsport environments. Innovative

More information

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product 996A106032 TUM 1024 REV. E 06.02.14 Tranberg AS P.O. Box 8033 N-4068 Stavanger

More information

DRAWER SYSTEMS HEAVY-DUTY STEEL & ALUMINUM Heavy-Duty Steel Drawer System. Heavy-Duty Aluminum Drawer System

DRAWER SYSTEMS HEAVY-DUTY STEEL & ALUMINUM Heavy-Duty Steel Drawer System. Heavy-Duty Aluminum Drawer System HEAVY-DUTY STEEL & ALUMINUM DRAWER SYSTEMS Heavy-Duty Steel Drawer System 500 lb. Rated Slides - Drawer slides are rated to hold up to the rigors of heavy-duty use and will support heavy tools and other

More information

a Nexans company Catalogue 2009

a Nexans company Catalogue 2009 a Nexans company Catalogue 2009 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium

More information

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1 Parts B - Section B Parts. Introduction To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use the parts list, and the accompanying illustration, to describe

More information

Relay Couplers. Product Selection Guide

Relay Couplers. Product Selection Guide Relay Couplers Product Selection Guide Relay Couplers in Weidmuller's World Switching, amplifying and multiplying. Weidmuller s relay couplers give their all! RSS Slim measuring and monitoring relays:

More information

Industrial Specification Grade Straight Blade Receptacles. Duplex and Single Receptacles

Industrial Specification Grade Straight Blade Receptacles. Duplex and Single Receptacles Industrial Specification rade 2 Pole, 3 ire rounding Duplex and Single A-5 STRAIHT BLADE TESTIN & CODE Spec. C-596 (file no. 15058). C22.2 no. 42, CSA (file no. 6233-01). 2.37" (60.2mm) 1.31" (33.3mm)

More information

FILTERED FAN PACKAGES

FILTERED FAN PACKAGES FILTERED FAN PACKAGES PLASTIC & METAL FILTERED FANS EFFICIENT, QUITE BALL BEARING MOTORS NEMA TYPE 1 AND 3R ALL KITS INCLUDE GASKETS, HARDWARE, AND TEMPLATE UL LISTED Plastic FILTER FAN PACKAGES Injection

More information

AEBN: Date: 12/3/07. Subject: Beacon Inrush Current

AEBN: Date: 12/3/07. Subject: Beacon Inrush Current AEBN: 120307 Date: 12/3/07 Subject: Beacon Inrush Current In addition to the nominal current rating for a beacon, often times there is an inrush current and, for flashing beacons, a repetitive surge current.

More information

Feature. Model comment JG 3NA B L - B - D3

Feature. Model comment JG 3NA B L - B - D3 Feature Device type universal nut terminals with safety protective cover -A Power Output Rated load voltage 20VAC/VAC Triac power switch Have DC-AC (DC signal to control the AC load) AC-AC (AC signal to

More information

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories) MX40-6043 Series MX40-7XXX Series MX40-6XXX Series Selection Guide Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional control from a DDC system

More information

Insulated Tools. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Insulated Tools. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1 F o r P Insulated Tools r o f e s s i o Klein insulated tools maintain the highest level of quality Klein is known for, and they offer added protection against shock from energized sources with voltage

More information

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077 Electrical installations in buildings for ring-tongue applications acc. to UL 1077 S 200 MR is a high-performance supplementary protector with ring cable lug connections conforming to UL, CSA, and IEC

More information

Seven-eighths-spacing Rackmount Kit/Chassis Rackmount Kit. Techmar enclosure designs include interchangeable modular components,

Seven-eighths-spacing Rackmount Kit/Chassis Rackmount Kit. Techmar enclosure designs include interchangeable modular components, SRK/CRK SERIES Seven-eighths-spacing Rackmount Kit/Chassis Rackmount Kit Techmar enclosure designs include interchangeable modular components, punched hole patterns and captive hardware, resulting in a

More information

Light Fittings & Accessories Tel: Fax:

Light Fittings & Accessories Tel: Fax: Email: sales@nlslight.com.au Light Fittings & Accessories Tel: 02 4732 5444 Fax: 02 4732 6600 Code Item Inner Outer Twin PLC D/L C/W Electronic Control Gear F&P 20161NLS 2 x 26Watt White Frost Glass 1

More information

Discount Schedule: C2. Subclass: DS0. Type 1 & 3R Double-Door Telephone Cabinet T-Handle Lock. Discount Schedule: C2.

Discount Schedule: C2. Subclass: DS0. Type 1 & 3R Double-Door Telephone Cabinet T-Handle Lock. Discount Schedule: C2. T-Handles Illustration Sheet and Type 3R Double-Door Enclosure Padlock Handle Type 3R Padlock Handle 25350 Type 3R padlock handle Type 3R Padlock Handle is intended to be used as a replacement mechanism

More information

NOTICE TO MEMBERS No February 5, 2003

NOTICE TO MEMBERS No February 5, 2003 NOTICE TO MEMBERS No. 2003-008 February 5, 2003 NEW EQUITY OPTION CLASSES Bourse de Montréal Inc.(The Bourse) and (CDCC) hereby inform you that at the opening of trading on Monday, February 10, 2003 the

More information

HANDWHEELS.

HANDWHEELS. HANDWHEELS 5 Handwheels Aluminum Angular Solid Handwheel...5.2 Aluminum Angular Spoked Handwheel... 5.2 Aluminum Finger Wheel... 5.10 Cast Angular Spoked Handwheel... 5.3 Cast Iron Angular Spoked Handwheel...

More information

CEELOK FAS-T CONNECTORS

CEELOK FAS-T CONNECTORS CEELOK FAS-T CONNECTORS Small Form Factor, Field Terminable Connectors CeeLok FAS-T connectors ofer a small form factor, ield terminable I/O connector capable of 0 Gb/s Ethernet. Crimpsnap contacts enable

More information

Table of Contents. Riser Rings. Riser Rings. Riser Rings. Product Description Page

Table of Contents. Riser Rings. Riser Rings. Riser Rings. Product Description Page Riser Ring Catalog Table of Contents Riser Rings Product Description Page Riser Rings Steel And Cast Iron Riser Rings Adjustable Riser Rings Steel Manhole Riser Rings Steel Catch Basin Riser Rings Steel

More information

PRODUCT MANUAL - M096

PRODUCT MANUAL - M096 PRODUCT MANUAL - M096 MODEL 270 ELECTRIC CAN OPENER 1 I. LABELS L087--CAUTION 2 II. SPECIFICATIONS MODEL NO. 270 POWER 115 VOLT, 1.5 AMP, 50-60HZ REQUIREMENTS 230 VOLT, 0.8 AMP, 50-60 HZ NORMAL SPEED 200-250

More information

ARONOFF CENTER FOR THE ARTS JARSON-KAPLAN THEATER TECHNICAL SPECIFICATIONS. Stage and Dock Information

ARONOFF CENTER FOR THE ARTS JARSON-KAPLAN THEATER TECHNICAL SPECIFICATIONS. Stage and Dock Information Stage and Dock Information Seating Capacity: Orchestra 260 inc 20 loose chairs/10 each side Inc 26 pit seats Rows AA and BB Balcony 1 90 inc 20 loose chairs/10 each side Balcony 2 87 inc 20 loose chairs/10

More information

5/16 x 20 3, /8 x 20 5, /2 x 20 9, /8 x 20 13, PART NUMBER

5/16 x 20 3, /8 x 20 5, /2 x 20 9, /8 x 20 13, PART NUMBER Binder Chains & Load Binders Binder Chains High Test - Grade 4 SIZE APPROX. WEIGHT CROSBY CAMPBELL /6 x 20,900 2899 02266 2 /8 x 20,400 29004 022292 4 /2 x 20 9,200 29022 -- 60 /8 x 20,000 290 -- 90 Transport

More information

EPIC Rectangular Connectors HBE 24 Plugs & Receptacles

EPIC Rectangular Connectors HBE 24 Plugs & Receptacles HBE 24 Plugs & Receptacles HBE 24 SCREW & CRIMP TERMINATED INSERTS SCREW TERMINATED View from Cable Side CRIMP TERMINATED Contacts Sold Separately Description Screw Terminated with wire protection Screw

More information

Display Systems. 1. General. A. Multi-Function Display (MFD) B. Primary Flight Display (PFD)

Display Systems. 1. General. A. Multi-Function Display (MFD) B. Primary Flight Display (PFD) CIRRUS AIRPLANE MAINTENANCE MANUAL Display Systems CHAPTER 31-60: DISPLAY SYSTEMS GENERAL 31-60: DISPLAY SYSTEMS 1. General This section covers those systems and components which give visual display of

More information

Bourdon Tube Pressure Switches

Bourdon Tube Pressure Switches Bourdon Tube es Ranges to 8000 psi (55. bar) FEATURES Visible calibrated dial On/off indication (except hermetically sealed snap switch models) Adjustable or fixed deadband SPT snap-action, hermetically

More information

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web:  - SVL Essential DIN Rail Series SVL Series power supplies are perfect for high volume, controlled environment applications where essential features are the only requirement. When space inside an enclosure

More information

Weatherproof Boxes, Covers, Lampholders and Lighting Fixtures

Weatherproof Boxes, Covers, Lampholders and Lighting Fixtures commercial and industrial fittings: Weatherproof Boxes, Covers and Lighting Fixtures Weatherproof Boxes, Covers, Lampholders and Lighting Fixtures Applications Use in branch circuit wiring for wet, damp

More information

ER36D Range. IMPORTANT: This model is not approved for field conversions of gas types or altitude settings.

ER36D Range. IMPORTANT: This model is not approved for field conversions of gas types or altitude settings. ER6D Range Page Description Page Description Cooktop Assembly Cooktop Parts Burners & Tubes 5 Manifold Assembly 6 Manifold Parts 7 Control Panel Assy 9 Oven Assembly 0 Oven Parts Exterior Components Exterior

More information

DRESS NUTS .312 DIA. (7,92Ø) .280 (7,11) UNS .215 DIA. (5,46) .070 (1,78) .040 (1,02) NICKEL PLATED BLACK

DRESS NUTS .312 DIA. (7,92Ø) .280 (7,11) UNS .215 DIA. (5,46) .070 (1,78) .040 (1,02) NICKEL PLATED BLACK Switchlocks: Y, H & A Series DRESS UTS.280 (7,11).312 DIA. (7,92Ø) 10-48 US.215 DIA. (5,46).040 (1,02).070 (1,78) 531300201 175052745 ALUMIIUM AODIZE 298D01201 298D01A56 580700201 Pushbuttons: 8020, 8060,

More information

Table of Contents. DS107 LUXEON Rebel PLUS Product Datasheet Lumileds Holding B.V. All rights reserved.

Table of Contents. DS107 LUXEON Rebel PLUS Product Datasheet Lumileds Holding B.V. All rights reserved. Illumination LUXEON Rebel PLUS The original high power LED LUXEON Rebel PLUS is designed with the highest possible efficacy and light output from an industry standard 4530 package with a 2.5mm 2 dome.

More information

Accessories. LED AWNING LIGHT RGB External LED light available in white or multi-colored (RGB).

Accessories. LED AWNING LIGHT RGB External LED light available in white or multi-colored (RGB). RAFTER LED The classic central rafter for the fabric, equipped with 36 LED lights. AWNING ARMS LED Two pairs of LED strips for the arms of the awning. KIT AWNING LED Pair of LED to be fixed on the front

More information

Portable Power Distribution for Generator Applications

Portable Power Distribution for Generator Applications Portable Power Distribution for Generator Applications PowerHOUSE Portable Distribution Boxes PowerFLEX Cable Assemblies PowerGATE Switches & Panels PowerPARTS Wiring Devices 060308 About Lex Products

More information

Assembly TOOLS REQUIRED: 17mm and 14mm or equivalent wrenches.

Assembly TOOLS REQUIRED: 17mm and 14mm or equivalent wrenches. Instructions for 3 Trimmer Rack, 3TR* *Patents Pending Assembly TOOLS REQUIRED: 17mm and mm or equivalent wrenches. 15 26 26 16 15 16 Attach the lower mounting brackets to the Trimmer Rack poles as shown

More information

TENDABOX BX3000. Cassette awning with folding arms BX3000. Description. Options:

TENDABOX BX3000. Cassette awning with folding arms BX3000. Description. Options: TENDABOX Description One-piece U-shaped protective cover (Dimension 179 x 145 mm), as from 500 cm total width protective cover inner reinforcement (Dimension 179 x 145 mm), of extruded aluminium profile

More information

CONTENTS. Gold Bond Fasteners Bolts 1 Clamps 3 Nuts 4 Washers 5. Hoist Rings Center Pull 6 Side Pull 7. Socket Head Stripper Bolts Inch 8 Metric 9

CONTENTS. Gold Bond Fasteners Bolts 1 Clamps 3 Nuts 4 Washers 5. Hoist Rings Center Pull 6 Side Pull 7. Socket Head Stripper Bolts Inch 8 Metric 9 CONTENTS PAGE NUMBER Gold Bond Fasteners Bolts 1 Clamps 3 Nuts 4 Washers 5 Hoist Rings Center Pull 6 Side Pull 7 Socket Head Stripper Bolts Inch 8 Metric 9 Punch Holder Shanks 10 Roller Stock Guides 11

More information

uickship Guide 2018 Vol. 1

uickship Guide 2018 Vol. 1 uickship Guide 2018 Vol. 1 Index Quickship Policies...2 Aerion LED...3 Amica 2...4 Amica LED...5 Equation 2...6 Luna LED...7 Veer LED...8 Avenue B & 6 LED...9 Covert Lite... 10 Focus Wall Wash... 11 Seem

More information

Installation and Maintenance Manual

Installation and Maintenance Manual Freestanding Gas Stove MODEL: PGS2005 GPEBB20R GPEBW20R Installation and Maintenance Manual Warning Maintenance products should be carried out by professional and technical personnel with relevant qualification,

More information

uickship Guide 2017 Vol. 3

uickship Guide 2017 Vol. 3 uickship Guide 2017 Vol. 3 Index Quickship Policies... 2 Aerion LED... 3 Amica 2... 4 Amica LED... 5 Equation 2... 6 Luna LED... 7 Avenue B & 6 LED... 8 Focus Wall Wash... 9 Seem 2, 4, 4-LP & 6 LED...

More information

MOSQUITO PROTECTION. Effective, convenient, season-long * mosquito protection for your entire deck, porch or patio!

MOSQUITO PROTECTION. Effective, convenient, season-long * mosquito protection for your entire deck, porch or patio! MOSQUITO PROTECTION Effective, convenient, season-long * mosquito protection for your entire deck, porch or patio! Haven Backyard Light & Mosquito Repellent Fixture combines attractive, efficient LED lighting

More information

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions Therme storage water heater Table of contents Symbols used... 8 Installation instructions Water supply... 9 Choice of location... 9 Installation of the Therme... 9 Fitting the draining and venting valve...

More information

TIN KNOCKER TK NO. 30 CLEAT BENDER INSTRUCTIONS & PARTS DIAGRAM. TK No. 30 CLEAT BENDER

TIN KNOCKER TK NO. 30 CLEAT BENDER INSTRUCTIONS & PARTS DIAGRAM. TK No. 30 CLEAT BENDER 1 TIN KNOCKER TK NO. 30 CLEAT BENDER INSTRUCTIONS & PARTS DIAGRAM TK No. 30 CLEAT BENDER Sheet Metal Equipment Sales Inc. Dean P. O'Connell, President Green Bay, Wisconsin Phone - (920)-662-9966 Fax -

More information

Owner's Guide A Installation Instructions Service Data Sheet

Owner's Guide A Installation Instructions Service Data Sheet Product No. Series 30" slide-in Color stainless Market North America Owner's Guide A00539301 Installation Instructions 318201697 Service Data Sheet 807880414 FFGS3026TS.jpg C.wmf BRLFGS3025PFH.wmf BFFGS3025PBG.wmf

More information

Parts List & Exploded View SETTE MAIN ASSEMBLY. Sette 30/270/270W Main Exploded View SA6 SA3 SA1 SA2 SA7 32 SA4 SA SA5 20 REV

Parts List & Exploded View SETTE MAIN ASSEMBLY. Sette 30/270/270W Main Exploded View SA6 SA3 SA1 SA2 SA7 32 SA4 SA SA5 20 REV Sette 30/270/270W Main Exploded View SA6 Parts List & Exploded View SETTE MAIN ASSEMBLY 8 24 SA3 5 6 7 8 25 23 SA 22 64 93 8 5 27 SA2 28 29 9 30 3 5 SA7 32 26 SA4 9 0 SA7 2 7 SA5 2 4 8 20 REV 09257 Page

More information

TURN YOUR BACKYARD INTO A HAVEN. A preferred choice of electrical pros since 1936.

TURN YOUR BACKYARD INTO A HAVEN. A preferred choice of electrical pros since 1936. TURN YOUR BACKYARD INTO A HAVEN A preferred choice of electrical pros since 1936. DAY TO NIGHT, Turn your backyard into a HAVEN all season long. NuTone Haven Backyard Lighting & Mosquito Repellent System

More information

X-Series Hexapod Assembly Instructions

X-Series Hexapod Assembly Instructions X-Series Hexapod Assembly Instructions General Warnings and Cautions Danger (May cause serious injury or death) Keep water, flammables, solvents and other liquids clear from actuator. Never place fingers,

More information

Power Tong Torque Manual

Power Tong Torque Manual Power Tong Torque Manual 1 Contents Power Tong Torque Monitor 1. Description:... 3 2. System Functions:... 3 3. Future Optional Functionality:... 3 4. Panel Display and Operation:... 6 4.1. Setting the

More information

60W Single Output LED Power Supply MODEL:PLP OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

60W Single Output LED Power Supply MODEL:PLP OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT 60W Single Output LED ower Supply L-60 series MODEL:L-60-48 OUTUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 4.8 Vp-p (Max ) I/: 230VAC V1: 3.58 Vp-p (Max

More information

MIRAGE PATIO AWNING. This publication covers installation for the following models: Mirage w/ Direct Response

MIRAGE PATIO AWNING. This publication covers installation for the following models: Mirage w/ Direct Response RV INSTALLATION MANUAL MIRAGE PATIO AWNING This publication covers installation for the following models: Mirage w/ Direct Response Read this manual before installing or servicing this product. Failure

More information

[Docket No. FAA ; Directorate Identifier 2007-CE-053-AD; Amendment ; AD ]

[Docket No. FAA ; Directorate Identifier 2007-CE-053-AD; Amendment ; AD ] [Federal Register: July 2, 2008 (Volume 73, Number 128)] [Rules and Regulations] [Page 37783-37786] From the Federal Register Online via GPO Access [wais.access.gpo.gov] [DOCID:fr02jy08-5] DEPARTMENT OF

More information

SECTION 8 PARTS LIST WITH EXPLODED VIEWS

SECTION 8 PARTS LIST WITH EXPLODED VIEWS GAS COOKTOP- SERIES Parts List with Exploded Views SECTION PARTS LIST WITH EXPLODED VIEWS -1 Parts List with Exploded Views GAS COOKTOP- SERIES CTG- PARTS LIST (INCLUDING I & ICB MODEL PARTS) Domestic

More information

Big SHOT III Hybridization Oven

Big SHOT III Hybridization Oven Big SHOT III Hybridization Oven Models 230402 and 230402-2 Whether you are working with Northern Blots, Southern Blots, Microarrays or another application that requires incubation, you will find the Big

More information

Lighting Fixtures. Assemblies and Components. Lighting Fixtures Assemblies and Components

Lighting Fixtures. Assemblies and Components. Lighting Fixtures Assemblies and Components Lighting Fixtures Assemblies and Components The finest quality, delivered on time and on budget. Polymer Products offers a host of solutions for your light fixturing needs: Small Wall Brackets Ceiling

More information

E32 Series. Fiber Units Support an Increasing Range of Applications. Fiber Units. Features. Standard Models First, Our Standard Lineup Page 18

E32 Series. Fiber Units Support an Increasing Range of Applications. Fiber Units. Features. Standard Models First, Our Standard Lineup Page 18 Photoelectric Units Units Support an Increasing Range of s Standard Models Models available in a wide variety of shapes customization service for virtually any application Environment-resistive Models

More information

FIBER OPTIC CLOSURES

FIBER OPTIC CLOSURES FIBER OPTIC CLOSURES In-line type and dome type - series CLS-I, CLS- IF2X, CLS-D, CLS-DF2X144 and CLS-DF2X240 PACIFIC INTERCONNECTIONS - connecting the world with fiber optics IN-LINE TYPE FIBER OPTIC

More information

UnicOne Projector Powerful effects

UnicOne Projector Powerful effects Lighting UnicOne Projector Powerful effects UnicOne Projector Mini MCS/MRS551 C The UnicOne Projector range offers powerful lighting accents in a small, appealing package, making it ideal for retail and

More information

tttttt www.wealdelectronics.com This publication is issued to provide outline information only and unless specifically agreed to the contrary by WEALD ELECTRONICS LTD. in writing, is not to form part of

More information

KAWNEER 1786 RIM EXIT DEVICE

KAWNEER 1786 RIM EXIT DEVICE FEBRUARY, 2015 1 DOOR STILE Device C L 40" 41-9/32" Cylinder C L Bottom of door RIM EXIT DEVICE LOCATION DOGGING KEY EXIT DEVICE FILLER PLATE CYLINDER & CYLINDER RING HOUSING COVER CYLINDER INSTALLATION

More information

BR-2250/BR Burnisher. Operator and Parts Manual. Model No.: BR BR-2250 Can. Pac BR BR-2500 Can.

BR-2250/BR Burnisher. Operator and Parts Manual. Model No.: BR BR-2250 Can. Pac BR BR-2500 Can. BR-220/BR-200 Burnisher Model No.: 608342 BR-220 609248 BR-220 Can. Pac 608340 BR-200 609247 BR-200 Can. Pac Operator and Parts Manual NOBLES 1287 RANSOM STREET HOLLAND MI 49424 U.S.A. CUSTOMER SERVICE:

More information

Blue Series Hot Melt Hose with RediFlext II Hanger System

Blue Series Hot Melt Hose with RediFlext II Hanger System Instruction Sheet P/N 1124594_01 Blue Series Hot Melt Hose with RediFlext II Hanger System Safety WARNING! Allow only personnel with appropriate training and experience to operate or service the equipment.

More information

Media facade RGB LED lighting solution. Sustainable architectural LED lighting systems

Media facade RGB LED lighting solution. Sustainable architectural LED lighting systems Media facade LED lighting solution Sustainable architectural LED lighting systems Media facade LED lighting solution The LumenfacadeFX is a unique architectural video MediaFacade lighting solution that

More information

^sffip' ^ffl^p fflfctt ^M^F B^^kk.H. Service Bulletin. rrnm WOIIDTTMTW. bl/bu SUKoiNh

^sffip' ^ffl^p fflfctt ^M^F B^^kk.H. Service Bulletin. rrnm WOIIDTTMTW. bl/bu SUKoiNh ^sffip' ^ffl^p fflfctt ^M^F B^^kk.H Service Bulletin Subject:. rrnm WOIIDTTMTW bl/bu SUKoiNh Bulletin No:. Date: Manager. Parts Service. GT-36 Read and Initial NOTICE: Certain GT750's equipped with Constant

More information

Test Report: EPP

Test Report: EPP Test Report: E 150 24 150W Single Output with FC Function DESIGN VERIFY TEST Output Function Test Input Function Test rotection Function Test Control Function Test Component Stress Test SAFETY & E.M.C.

More information

HardSID Uno / UPlay user s guide HardSID Uno HardSID UPlay

HardSID Uno / UPlay user s guide HardSID Uno HardSID UPlay HardSID Uno / UPlay user s guide HardSID Uno HardSID UPlay HardSID Uno / UPlay user s guide 2010 Hard Software, Hungary 1 Safety information... 4 Introduction:... 5 Package contents... 5 System requirements...

More information

Hawker Beechcraft Corporation

Hawker Beechcraft Corporation Hawker Beechcraft Corporation CH-SECT-FIG PAGE NO. DATE CH-SECT-FIG PAGE NO. DATE 11-CONTENTS 1 11-20-01 0 11-20-01 1 11-20-01 2 11-20-01 3 11-20-01 4 11-20-01 5 11-20-01 6 11-30-01 0 11-30-01 0A 11-30-01

More information

2019 may september alaska cruises & cruisetours

2019 may september alaska cruises & cruisetours 2019 may september alaska cruises & cruisetours Whether this is your first cruise to Alaska or a return to the Great Land, the opportunity to study new beauty awaits. The 2019 season marks Princess 50

More information

QUALITY TIME 2013/14

QUALITY TIME 2013/14 QUALITY TIME 2013/14 PHIL OSO PHY Ever since Dick Allen turned metal tubing, straps, and padding into the first trunk mounted bicycle carrier in 1965, Allen s design philosophy has been governed by the

More information

Portable Banner Stands

Portable Banner Stands Portable Banner Stands OrchId 33.5 ORCHID - quick to assemble and easy to use - bamboo base, rail and pole are a sustainable choice - slide graphic rail - includes carry bag 1BANNER STANDS RETRACTABLE

More information

Terminals & Connectors

Terminals & Connectors Your Connection Since 1970 Terminals & Connectors 2 TABLE OF CONTENTS Adapters........................... 13 Brazed Barrel Lugs................... 16-17 Bullet Connectors....................9-10 Butt Connectors.......................3

More information

VILLAGE OF WINNETKA, ILLINOIS DEPARTMENT OF COMMUNITY DEVELOPMENT

VILLAGE OF WINNETKA, ILLINOIS DEPARTMENT OF COMMUNITY DEVELOPMENT AWN VILLAGE OF WINNETKA, ILLINOIS DEPARTMENT OF COMMUNITY DEVELOPMENT AWNING PERMIT APPLICATION Important note regarding Awning Code changes Effective March 4, 2003, awning regulations were modified to

More information

Hose Fitting Selection Chart

Hose Fitting Selection Chart LOW/MEIUM Hose Fitting Selection hart PERMNENT REUSLE SERIES SERIES N SH SIZE RNGE* Zinc Plated Steel 903 3630 (-03 to -12), 3R30, 3130, 37L, 3800, 3840, 3580, 3440 (-04 to -08), 30T (-04 to-08) 90H 3630

More information

SERIE SP60 - SP60 SERIES

SERIE SP60 - SP60 SERIES Schemi elettrici disponibili - Wiring diagrams available Interruttore unipolare Single-pole switch Pag 3 4 Interruttore bipolare luminoso (spia dipendente) Illuminated double-pole switch (dependent light)

More information

Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1

Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1 3-18.3-5 Specifications of OXY-THERM TITAN burners Typical burner data Fuel: natural gas at 15 C with 10.9 kwh/nm 3 HHV - sg = 0.6 Oxygen: 90-100% purity Stated pressures are indicative. Actual pressures

More information

2016 PRODUCTS & PRICES

2016 PRODUCTS & PRICES 2016 PRODUCTS & PRICES LENGTH STOPS THAT ARE USER FRIENDLY Orders 1-800-821-3491 Phone 1-717-484-0230 Fax 1-717-484-0933 E-mail mayaposi@att.net Web mayaposi-stop.com MAYA POSITIONING EQUIPMENT MFG CO.

More information

Couplings for Gates Hoses 7 Combination Nipple

Couplings for Gates Hoses 7 Combination Nipple Supersedes 1 Long Shank Couplings for Gates Hoses 7 Combination Nipple Description: Cast brass, serrated shank, set has hex male and hex swivel female couplings, with a washer seal. Threads are GHT or

More information

SPECIFICATIONS. For 1 8 OD Tubing FERRULES FOR 1 8 OD TUBING. One piece PTFE ferrule with SS casing1. One piece PTFE ferrule with SS casing2 008FT32

SPECIFICATIONS. For 1 8 OD Tubing FERRULES FOR 1 8 OD TUBING. One piece PTFE ferrule with SS casing1. One piece PTFE ferrule with SS casing2 008FT32 4 OMNI-LOK FITTING SYSTEMS OMNI-LOK TYPE P For 1 16, 1 8 or 3 16 OD semi-rigid tubing and ¼ -28 UNF, M6 or 5 16-24 UNF threaded flat-bottom ports Pressure rated up to 1000psi (69 bar) when hand-tight High

More information

Frame - Front fork 01 1 Ball ring set, complete - - - city 8000101 1 Ball ring set, complete - - - rac 8000034 1 2 Spacer SP3 - - - - 8000035 1 3 Spacer SP1,5 - - - city 8000194 1 Spacer SP10 - - - rac

More information

O D U L. AEC Illuminazione S.r.l. Zona Industriale di Castelnuovo Subbiano (Ar) Tel. +39.(0) Fax +39.(0)575.

O D U L. AEC Illuminazione S.r.l. Zona Industriale di Castelnuovo Subbiano (Ar) Tel. +39.(0) Fax +39.(0)575. AC Illuminazione S.r.l. Zona Industriale di Castelnuovo 256 52010 Subbiano (Ar) Tel. +39.(0)575.041 Fax +39.(0)575.420878 n e w www.aecilluminazione.it aec@aecilluminazione.it 9 led 6 optics type only

More information

TWO PERSON WALL MOUNT

TWO PERSON WALL MOUNT ONE TIER TWO TIER THREE TIER FOUR TIER FIVE TIER SIX TIER 16 PERSON TWO PERSON WALL MOUNT Specifications Body: Entire unit (bottom, sides, top, back, and shelves) constructed of mild cold rolled 24 ga.

More information

SCHLAGE Cylinders and Keys. Introduction

SCHLAGE Cylinders and Keys. Introduction Introduction Schlage full size cylinders are available in a large number of keyways in either the (obverse) family or the C family. Restricted keyways are also available to order.you must specify the keyway

More information

TABLE & FURNITURE LEGS

TABLE & FURNITURE LEGS LEGS & LEVELERS TABLE & FURNITURE LEGS Furniture Levelers Furniture levelers from, perfect for entertainment and built-in shelving units. Table Legs The PMI Table Leg line has been very popular for more

More information

Preft j Lt-Modification Class or Type Manufacturer Model Prefix: X - Experimental (Army or Navy) Y - Service Test Or Limited Procurement (Army only)

Preft j Lt-Modification Class or Type Manufacturer Model Prefix: X - Experimental (Army or Navy) Y - Service Test Or Limited Procurement (Army only) 46-9 AIRCRAFT IDENTIFICATION STANDARDS US MILITARY AIRPLANE MODEL DESIGNATION Example: X PB 4 U -I Navy Y P -2 - A Army Preft j Lt-Modification Class or Type Manufacturer Model Prefix: X - Experimental

More information

VDE 1000V Insulated Tools

VDE 1000V Insulated Tools Tools Safety Caution 189 Insulated VDE Pliers PM-910 Insulated Wire Stripping Plier Certified to IEC 60900, VDE, DIN 1,000V safety standards and bear GS sign. High visibility molded ergonomic cushion handle

More information

Tall Cabinet Drawer Keyless Double Lock Installation [ xx]

Tall Cabinet Drawer Keyless Double Lock Installation [ xx] Tall Cabinet Drawer Keyless Double Lock Installation [002-97-xx] Note This install can be used for any Tall Cabinet Double Drawer Keyless Lock installation. The assembly process will be the same. The will

More information

Crimp & Cleave Termination Instructions

Crimp & Cleave Termination Instructions Your Optical Fiber Solutions Partner Crimp & Cleave Termination Instructions for 200 µm Harsh Environment SMA For Use With: 200 µm HE SMA Termination Kit 200 µm HCS Fiber-Optic Cable HE SMA 200 µm Crimp

More information

10x Corrosion Resistance 5x Abrasion Resistance 2x Chip Resistance 2x Scratch Resistance. 10x 5x 2x 2x. Textured Powder Paint Finish

10x Corrosion Resistance 5x Abrasion Resistance 2x Chip Resistance 2x Scratch Resistance. 10x 5x 2x 2x. Textured Powder Paint Finish On-Site Storage The latest JOBOX innovations for unmatched security, versatility and durability New Textured Powder Paint Finish For Improved Durability* 10x 5x 2x 2x Site-Vault Security System 50% more

More information

Insulated Screwdrivers and Nut Drivers

Insulated Screwdrivers and Nut Drivers Insulated Screwdrivers and Nut Drivers Features: Klein insulated tools meet or exceed the IEC 60900 and ASTM F1505 standards, for insulated tools, and are clearly marked with the official 1000-volt rating

More information

ACCORD GENERAL SUR RESTRICTED ET LE COMMERCE. Agreement on Trade in Civil Aircraft Original: English/ anglais TECHNICAL SUB-COMMITTEE.

ACCORD GENERAL SUR RESTRICTED ET LE COMMERCE. Agreement on Trade in Civil Aircraft Original: English/ anglais TECHNICAL SUB-COMMITTEE. GENERAL AGREEMENT ON TARIFFS AND TRADE ACCORD GENERAL SUR RESTRICTED AIR/TSC/W/24/Rev.1 LES TARIFS DOUANIERS24 March 1982 Special Distribution ET LE COMMERCE Agreement on Trade in Civil Aircraft Original:

More information

Test Report: EPP

Test Report: EPP Test Report: E 100 24 100W Single Output with FC Function DESIGN VERIFY TEST Output Function Test Input Function Test rotection Function Test Control Function Test Component Stress Test SAFETY & E.M.C.

More information