Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)

Size: px
Start display at page:

Download "Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)"

Transcription

1 (general purpose valve) ADK11/ADK12 Series NC (normally closed) type, NO (normally open) type Port size: Rc1/4 to Rc1 Diaphragm structure Excluding ADK12 JIS symbol ADK11: NC (normally closed) type OUT IN ADK12: NO (normally open) type OUT IN Common specifications Item Standard specifications Optional specifications Working fluid Working pressure differential range MPa Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil ( mm 2 /s or less) ot water Max. working pressure MPa Withstanding pressure (water) MPa 2 4 Fluid temperature (Note 1) C -10 to to 90 Ambient temperature C -10 to 60 eat proof class Atmosphere Valve structure Valve seat leakage (Note 2) cm 3 /min. (ANR) Mounting attitude ody, sealant Place free of corrosive gas and explosive gas Pilot kick type poppet, diaphragm structure 1 or less (air) Free ronze, nitrile rubber 0 to 1.0 (refer to max. working pressure differential in individual specifications.) ronze, ethylene propylene diene rubber Note 1: No freezing Note 2: For ADK11 (NC (normally closed) type), these values apply to pneumatic pressure 0.02 to 1.0 MPa, and for ADK12 (NO (normally open) type), these apply to pneumatic pressure 0.02 to 0.6 MPa. When used at a pressure less than 0.02 MPa, the sealant may be unstable. Consult with CKD in this case. Individual specifications Item Port size Orifice (mm) Min. working pressure diff. (MPa) Max. working pressure diff. (MPa) Apparent power (VA) Power consumption (W) Air Water, kerosene Oil ( mm 2 /s) Rated voltage olding Starting AC DC AC DC AC DC AC DC z 60 z z 60 z /60 z NC (normally closed) type ADK11-8A Rc1/ VAC /60 z ADK11-10A Rc3/ VAC 60 z ADK11-1 Rc1/ VAC /60 z ADK11-20A ADK11-2 Rc3/4 Rc VAC 60 z 12 VDC NO (normally open) type 24 VDC ADK12-1 Rc1/ VDC ADK12-20A Rc3/ VDC ADK12-2 Rc1 28 *1: The model numbers above show the basic port size (Rc). Refer to ow to order for other combinations. *2: The value in ( ) is the power consumption for the type with DIN terminal box. *3: The value in [ ] is the power consumption for the coil with diode. *4: Refer to DC column for the maximum working pressure differential of coil with diode. *5: Voltage fluctuation should be within ±10% of the rated voltage. *6: Consider using the A71 Series if the pressure is 0.02 MPa or less. *7: When using with a low vacuum, vacuum the OUT port side /8 10/ / *2 (10.4) 14*3 [17] Weight (kg)

2 Optional specifications Sealant Coil (heat proof class) Fluid temperature Ambient temperature C C Valve seat leakage (Note 2) cm 3 /min. (ANR) Fluoro rubber Ethylene propylene diene rubber 5 to 60 5 to to 60 (Note 1) -10 to 90 (Note 1) -10 to 60 1 or less (air) Note 1: No freezing Note 2: For ADK11 (NC (normally closed) type), these values apply to pneumatic pressure 0.02 to 1.0 MPa, and for ADK12 (NO (normally open) type), these apply to pneumatic pressure 0.02 to 0.6 MPa. When used at a pressure less than 0.02 MPa, the sealant may be unstable. Consult with CKD in this case. N/ US/ FA/ F/ FV FW/ Flow characteristics Port size Orifice (mm) NC (normally closed) type ADK11-8A ADK11-10A ADK11-1 ADK11-20A ADK11-2 NO (normally open) type Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc ADK12-1 ADK12-20A ADK12-2 Rc1/2 Rc3/4 Rc *1: Effective sectional area S and sonic conductance C are converted as S 5.0 C. Flow characteristics C [dm 3 /(s bar)] b Cv flow factor S (mm 2 ) F FL A A AP/ AD APK/ ADK For dry air Explosion proof V/ VL SA/ SV NP/NAP/ NVP C/ MX/ Other.P. systems PD/FAD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve 283

3 ow to order NC (normally closed) type ADK11 25 A 0 3A S P6 A Port size Type of thread E Mounting plate I Rated voltage F Other options Copper and PTFE free D Coil housing Surge suppressor Symbol A Port size 8 1 / / / / C ody/sealant combination *1 *2 *3 *4 <Example 1 of model number> ADK C-AC100V Series: APK11 A Port size: 1/2 Type of thread: Rc C ody/sealant combination : ody - bronze, sealant - nitrile rubber D Coil housing: rommet lead wire E to : lank I Rated voltage : 100 VAC /60 z, 110 VAC 60 z A N C 0 D E J P L M R AC100V Type of thread Rc NPT Descriptions ody/sealant combination ody Sealant Treatment Remarks D to I Std. Option Nitrile rubber ronze Fluoro rubber Stainless Nitrile rubber steel Fluoro rubber Nitrile rubber ronze Fluoro rubber Ethylene propylene diene rubber Nitrile rubber Stainless steel Fluoro rubber Ethylene propylene diene rubber Refer to the following page for details on the coil housing, other options and voltage, etc. Oil free ot water (up to 90 C *1) ot water (up to 90 C *1) Refer to page 36 in the Introduction for details on the material combinations. <Example 2 of model number> ADK11-20N-4AS-AC200V Series: ADK11 A Port size: 3/4 Type of thread: NPT C ody/sealant combination : ody - bronze, sealant - fluoro rubber D Coil housing : Open frame lead wire (class coil) E Mounting plate: Selected F Other options: lank Surge suppressor: Selected I Rated voltage : 200 VAC /60 z, 220 VAC 60 z Note on model no. selection Note on C *1: C: When selecting 4A, 4M or 4N. *2: Only A (port size) 15 (1/2), 20 (3/4) or 25 (1) is available for C P/R. *3: The maximum working pressure differential is 0.6 MPa for the ethylene propylene diene rubber seal combination (C P/R). *4: The ethylene propylene diene rubber seal combination (C P/R) cannot be used with air. (Compressed air contains oil, and ethylene propylene diene rubber is not oil-resistant.) 284

4 For D to I, the combinations indicated with symbols can be manufactured. Note that if options E to are not required, no symbol is indicated. N/ D Coil housing E F Other options I Rated voltage Cable gland Conduit Descriptions (Marine cable gland) (Conduit pipe) Descriptions A-15a A-15b A-15c CTC19 1/2 2C 2E 2 2 3A 3M 3N 3I 3J 4A 4M 4N 5M 5N 5I 5J 2C Std. rommet lead wire DIN terminal box DIN terminal box DIN terminal box + small light (1/2) (Pg11) (Pg11) Lead wire Open P terminal box (1/2) frame type P terminal box + light (1/2) P terminal box (IP65 or equivalent) (1/2) P terminal box + light (IP65 or equivalent) (1/2) Lead wire Open frame type P terminal box (1/2) (eat proof class ) P terminal box + light(1/2) Lead wire Open P terminal box (1/2) frame type P terminal box + light (1/2) (Diode integrated) P terminal box (IP65 or equivalent) (1/2) P terminal box + light (IP65 or equivalent) (1/2) Option Mounting plate rommet lead wire 300 mm D E F D E F D E F Surge suppressor S S S Copper and PTFE free 100 VAC, 200 VAC 100 VAC, 200 VAC, P6 12 VCD, 24 VDC, 48 VDC, 100 VDC 100 VAC, 200 VAC, 24 VDC 100 VAC, 200 VAC 12 VCD, 24 VDC, 48 VDC, 100 VDC P6 100 VAC, 200 VAC, 12 VDC, 24 VDC, 100 VDC 100 VAC, 200 VAC, 12 VDC, 24 VDC, 48 VDC, 100 VDC 100 VAC, 200 VAC, 12 VDC, 24 VDC, 100 VDC P6 P6 100 VAC, 200 VAC 100 VAC, 200 VAC Refer to the following precautions for D to I. Conduit (CTC19) (1/2) US/ FA/ F/ FV FW/ F FL A A AP/ AD APK/ ADK For dry air Explosion proof V/ VL SA/ SV NP/NAP/ NVP 2E 2 2 DIN terminal box C/ MX/ 3A 4A 3M 3N 4M 4N 5M 5N 3I 3J 5I 5J Open frame grommet lead wire 300 mm 4A (heat proof class ) (diode integrated) Open frame P terminal box 4M, 4N (heat proof class ) 5M, 5N (diode integrated) Open frame P terminal box (IP65 or equivalent) 5I, 5J (diode integrated) Refer to page 224 for coil selection. Note on model no. selection Note on D *5:, 5M, 5N, 5I and 5J are coils for which AC power is converted to DC with a diode. Note on E to *6: Select one among D, E, F, and for F. *7: The surge suppressor is an accessory for the lead wire coil. When selecting a coil with terminal box, the surge suppressor is mounted in the terminal box. *8: As standard, the surge suppressor is incorporated in the coil with diode and the 24 VDC coil (D 2), so the surge suppressor symbol S cannot be selected. *9: Tropicalization (rust-proof coating) is available as a measure against rust. Contact CKD for more information. Note on I *10: 100 VAC coil is compatible with 100 VAC /60 z and 110 VAC 60 z, and 200 VAC coil is compatible with 200 VAC /60 z and 220 VAC 60 z. Note that the coils D /5M/5N/5I/5J can be used only with 100 VAC /60 z or 200 VAC /60 z. *11: For voltages other than above, consult with CKD. *12: The lead wire is available in the standard 300 mm length, and 0 mm, 1000 mm, 2000 mm and 3000 mm lengths. Contact CKD for more information. Other.P. systems PD/FAD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve 285

5 ow to order NO (normally open) type ADK12 15 A 0 3A S P6 AC100V A Port size Type of thread D Coil housing C ody/sealant combination *1 E Mounting plate F Other options Copper and PTFE free Surge suppressor Symbol A Port size 15 1 / / A N C D to I Type of thread Std. Option Rc NPT I Rated voltage Descriptions ody/sealant combination ody Sealant Treatment Remarks Nitrile rubber ronze Fluoro rubber Stainless Nitrile rubber steel 0 D E J P L M R Fluoro rubber Nitrile rubber ronze Fluoro rubber Ethylene propylene diene rubber Nitrile rubber Stainless steel Fluoro rubber Ethylene propylene diene rubber Oil free ot water (up to 90 C *1) ot water (up to 90 C *1) Refer to page 36 in the Introduction for details on the material combinations. Refer to the following page for details on the coil housing, other options and voltage, etc. <Example 1 of model number> ADK12-20A-03A-DC24V Series: ADK12 A Port size: 3/4 Type of thread: Rc C ody/sealant combination : ody - bronze, sealant - nitrile rubber D Coil housing: Open frame lead wire E to : lank I Rated voltage: 24 VDC <Example 2 of model number> ADK ND-AC100V Series: ADK12 A Port size: 1/2 Type of thread: C ody/sealant combination : ody - bronze, sealant - fluoro rubber D Coil housing: Open frame type with P terminal box + light (1/2) E Mounting plate: Selected F Other options: Cable gland A-15a Surge suppressor: lank I Rated voltage : 100 VAC /60 z, 110 VAC 60 z Note on model no. selection Note on C *1: C: When selecting 4A, 4M or 4N. 286

6 For D to I, the combinations indicated with symbols can be manufactured. Note that if options E to are not required, no symbol is indicated. D Coil housing Descriptions 3A 3M 3N 3I 3J 4A 4M 4N 5M 5N 5I 5J 3A 4A 3M 3N 4M 4N 5M 5N Lead wire P terminal box (1/2) Open P terminal box + light frame type (1/2) P terminal box (IP65 or equivalent) (1/2) (1/2) Std. Option Open frame type (eat proof class ) Open frame type (Diode integrated) P terminal box + light (IP65 or equivalent) Lead wire P terminal box P terminal box + light Lead wire P terminal box P terminal box + light (1/2) (1/2) (1/2) (1/2) P terminal box (IP65 or equivalent) (1/2) P terminal box + light (IP65 or equivalent) (1/2) E Mounting plate Open frame grommet lead wire 300 mm 4A (heat proof class ) (diode integrated) Open frame P terminal box 4M, 4N (heat proof class ) 5M, 5N (diode integrated) F Other options Cable gland Conduit (Marine cable gland) (Conduit pipe) A-15a A-15b A-15c CTC19 D E F D E F D E F 1/2 Surge suppressor S S Copper and PTFE free P6 P6 I Rated voltage Descriptions 100 VAC, 200 VAC 12 VDC, 24 VDC, 48 VDC, 100 VDC 100 VAC, 200 VAC, 12 VDC, 24 VDC, 100 VDC 100 VAC, 200 VAC, 12 VDC, 24 VDC, 48 VDC, 100 VDC 100 VAC, 200 VAC, 12 VDC, 24 VDC, 100 VDC 100 VAC, 200 VAC P6 100 VAC, 200 VAC Refer to the following precautions for D to I. Conduit (CTC19) (1/2) N/ US/ FA/ F/ FV FW/ F FL A A AP/ AD APK/ ADK For dry air Explosion proof V/ VL SA/ SV NP/NAP/ NVP 3I 3J 5I 5J Open frame P terminal box (IP65 or equivalent) 5I, 5J (diode integrated) Refer to page 224 for coil selection. Note on D *2:, 5M, 5N, 5I and 5J are coils for which AC power is converted to DC with a diode. *3: *4: *5: *6: Note on I *7: *8: *9: Note on model no. selection Note on E to Select one among D, E, F, and for F. The surge suppressor is an accessory for the lead wire coil. When selecting a coil with terminal box, the surge suppressor is mounted in the terminal box. The surge suppressor is incorporated in the coil with diode as standard. Tropicalization (rust-proof coating) is available as a measure against rust. Contact CKD for more information. 100 VAC coil is compatible with 100 VAC /60 z and 110 VAC 60 z, and 200 VAC coil is compatible with 200 VAC /60 z and 220 VAC 60 z. Note that the coils D /5M/5N/5I/5J can be used only with 100 VAC /60 z or 200 VAC /60 z. For voltages other than above, consult with CKD. The lead wire is available in the standard 300 mm length, and 0 mm, 1000 mm, 2000 mm and 3000 mm lengths. Contact CKD for more information. 287 C/ MX/ Other.P. systems PD/FAD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve

7 Internal structure and parts list ADK11-8A/10A IN OUT 10 8A/10A ADK11-1/20A/ IN OUT 10 1 to 2 No Parts name Core assembly Shading coil *1 Coil Plunger assembly Plunger spring Kick spring Stuffing Sealant Diaphragm assembly ody O ring Material SUS405 or equivalent, SUS316L, SUS403 Cu (Ag for stainless steel body) SUS405 or equivalent, SUS304, NR (SUS405 or equivalent, SUS304, FKM or EPDM) *2,3 SUS304 SUS304 C3771 (SCS13) NR (FKM, EPDM) SUS303, SUS304, NR (SUS303, SUS304, FKM or EPDM) *3 CAC408 (SCS13) NR (FKM, EPDM) Copper (silver for stainless steel body) rass (stainless steel casting) Nitrile rubber (fluoro rubber or ethylene propylene diene rubber), nitrile rubber (stainless steel, fluoro rubber or ethylene propylene diene rubber) ronze casting (stainless steel casting) Nitrile rubber (fluoro rubber or ethylene propylene diene rubber) ( ) shows options. *1: When using the DC coil or a coil with diode, no shedding coil is used. *2: SUS304 is not used for port size 15 (1/2) to 25 (1). *3: EPDM is not compatible with port size 8 (1/4) and 10 (3/8). 288

8 Internal structure and parts list ADK12 Series N/ US/ FA/ F/ 3 9 FV FW/ F FL A No Parts name Core assembly Shading coil *2 Coil Plunger Push rod Fixed ferrous core Spring Spring holder NO valve assembly Kick spring Stuffing Sealant Diaphragm assembly ody O ring Material SUS403, SUS316L, SUS304 *1 Cu (Ag for stainless steel body) - SUS405 or equivalent SUS304 SUS405 or equivalent SUS304 POM (SUS303) SUS303, SUS304, NR (SUS303, SUS304, FKM or EPDM) SUS304 C3771 (SCS13) NR (FKM, EPDM) SUS303, SUS304, NR (SUS303, SUS304, FKM or EPDM) CAC408 (SCS13) NR (FKM, EPDM) ( ) shows options. *1: When the body/sealant combination symbol is other than O and, the material is SUS430, SUS316L, SUS304. *2: When using the DC coil or a coil with diode, no shedding coil is used Copper (silver for stainless steel body) - Acetal resin (stainless steel), nitrile rubber (stainless steel, fluoro rubber or ethylene propylene diene rubber) rass (stainless steel casting) Nitrile rubber (fluoro rubber or ethylene propylene diene rubber), nitrile rubber (stainless steel, fluoro rubber or ethylene propylene diene rubber) ronze casting (stainless steel casting) Nitrile rubber (fluoro rubber or ethylene propylene diene rubber) A AP/ AD APK/ ADK For dry air Explosion proof V/ VL SA/ SV NP/NAP/ NVP C/ MX/ Other.P. systems PD/FAD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve 289

9 Dimensions: ADK11 Series rommet lead wire type ADK11-8A/10A-*2C Lead wire length (300) Rc1/4 (8A) Rc3/8 (10A) Note 1: The dimensions are the same for the or NPT thread port size. rommet lead wire type ADK11-1/20A/2-*2C Lead wire length (300) 38 C D E A' F Note 1: The dimensions are the same for the or NPT thread port size. Note 2: Dimensions shown in ( ) are for SUS body. A C D E F ADK C ADK11-20A-02C ADK C (29) 32 (35) 41 (45) Rc1/2 Rc3/4 Rc1 290

10 Optional dimensions: ADK11 Series DIN terminal box ADK11-8A to 2-* 2E 2 2 * Refer to the grommet lead wire type dimensions on the left page for common dimensions. Open frame lead wire ADK11-8A to 2-* 3A 4A N/ US/ FA/ K J L (300) 46 F/ FV 39 (41) M 29 FW/ F Pg11 (1/2) FL A Dimensions shown in ( ) are for 1/2. J K ADK11-8A~2-*2 -AC (53.5) ADK11-8A/10A-*2 -DC (54) ADK11-1~2-*2 -DC (60) L M A AP/ AD APK/ ADK Open frame type + P terminal box ADK11-8A to 2-* 3 M / 4M 5 N 4N I J Open frame type + conduit ADK11-8A to 2-* 3A 4A 57 (60) For dry air Explosion proof V/ VL SA/ SV NP/NAP/ NVP C/ 29 MX/ Mounting plate ADK11-8A/10A-*** 1/ Mounting plate ADK11-1/20A/2-*** CTC19 (1/2) Dimensions shown in ( ) are for 1/2. Other.P. systems PD/FAD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order 30 2-ø P M 2-Q ADK11-1-*** ADK11-20A-*** ADK11-2-*** 3.2 M N N P Q ø9 ø9 ø11 eneral purpose valve 291

11 Dimensions: ADK12 Series Open frame lead wire type ADK12-1/20A/2-*3A (300) 46 C D E CKD A F Note 1: The dimensions are the same for the or NPT thread port size. A C D E F ADK A ADK12-20A-03A ADK A (29) 32 (35) 41 (45) Rc1/2 Rc3/4 Rc1 292

12 Optional dimensions: ADK12 Series Open frame type + P terminal box ADK12-1/20A/2-* 3 M / 4M 5 N 4N I J * Refer to the open frame lead wire type dimensions on the left page for common dimensions. Open frame type + cable gland ADK12-1/20A/2-* 3 M D 4 N E 5 F N/ US/ FA/ F/ FV FW/ 58 F FL A Open frame type + conduit ADK12-1/20A/2-* 3A 4A Mounting plate ADK12-1/20A/2-*** A AP/ AD APK/ ADK For dry air Explosion proof V/ VL SA/ SV NP/NAP/ NVP C/ P M 2-Q 3.2 N MX/ Other.P. systems ADK12-1-*** ADK12-20A-*** ADK12-2-*** M N P Q ø9 ø9 ø11 PD/FAD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve /2 57 (60) ø9 (A-15a) ø10 (A-15b) ø11 (A-15c) 28 CTC19 (1/2) Dimensions shown in ( ) are for 1/2. 293

PN 3000 Series Fail Closed Pneumatic Actuators

PN 3000 Series Fail Closed Pneumatic Actuators PN 3000 Series Fail Closed Pneumatic Description A of compact linear actuators having 5 diaphragm sizes for matching the requirements of 1/2" to 4" Spira-Trol valves at various differential pressures.

More information

BROEN UNIFLEX FITTINGS FOR WATER BROEN UNIFLEX TM FITTINGS FOR WATER

BROEN UNIFLEX FITTINGS FOR WATER BROEN UNIFLEX TM FITTINGS FOR WATER BROEN UNIFLEX FITTINGS FOR WATER TABLE OF CONTENTS Content Page Table of Contents 2 BROEN UniFlex TM BASIC 4 Product Overview 5 Water Fittings Bench Mounted Fitting with Swivel Spout... 6 Single Handle

More information

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series Dual Modular Safety Shutoff Valves with Proof of Closure Option DMV eco Series DMV-D eco Series DMV-DLE eco Series Two normally closed safety shutoff valves in one housing; each with the following approvals.

More information

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately) PCB Relay Small, Low-Cost 0-A Power Relay for PCB Applications Small, yet capable of switching up to a 0-A loads. Inexpensive. Ideal for home and industrial appliances, HVAC (heating, ventilating, and

More information

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination. SIDERMAT combination 630 to 1800 A sdmat_048_a_1_cat SIDERMAT combination are manually operated tri- or tetrapolar fuse disconnecting switches which can be triggered remotely. They provide breaking and

More information

B-Series Switches Temperature Switches

B-Series Switches Temperature Switches FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage treatment

More information

SIZE RANGE: 1 TO 10. PRESSURE RANGE: FULL VACUUM TO 275 psi

SIZE RANGE: 1 TO 10. PRESSURE RANGE: FULL VACUUM TO 275 psi 2 3 4 5 HANDLE OPTION ITEM DESCRIPTION STANDARD MATERIAL 1 Wrench - Locking Durcor -62 2 Hex Head Cap Screw 316 Stainless Steel 3 Washer 18-8 Stainless Steel 4 Wrench Stop Plate - Locking 304 Stainless

More information

Limit Switches. 6.2 E47 Precision Switches

Limit Switches. 6.2 E47 Precision Switches Limit Switches E47BMS02 E47BMS11 E47BMS40.2 Product Description............................................. 2 Approvals..................................................... 2 Features and Benefits...........................................

More information

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution sdmat_048_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Single, oversized roller compresses a low friction hose through a full 360-degree rotation

Single, oversized roller compresses a low friction hose through a full 360-degree rotation Graco EP Series Hose Pump Technology Single, oversized roller compresses a low friction hose through a full 360-degree rotation More flow per revolution than conventional designs One hose compression per

More information

Pressure relief valve VRH 5 / VRH 30 / VRH 60 / VRH 120

Pressure relief valve VRH 5 / VRH 30 / VRH 60 / VRH 120 Data sheet Pressure relief valve VRH 5 / VRH / VRH 60 / VRH hpp.danfoss.com Table of Contents Contents 1. Introduction...2 2. Features...2 3. Variants...2 4. Technical data...3 5. Flow...3 5.1 VRH 5 Max.

More information

Pressure relief valve VRH 5 / VRH 30 / VRH 60 / VRH 120

Pressure relief valve VRH 5 / VRH 30 / VRH 60 / VRH 120 Data sheet Pressure relief valve VRH 5 / VRH / VRH 60 / VRH 120 hpp.danfoss.com Table of Contents Contents 1. Introduction...2 2. Features...2 3. Variants...2 4. Technical data...3 5. Flow...4 5.1 VRH

More information

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation. DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_156_a_2_cat Direct

More information

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W CV5 Slim 12V Outdoor Converter 5 YEARS IP67 50.000 hrs The perfect partner to team up with any 12V LED solution Full power range from 15W to 200W SLIM profile (40x23mm) to fit in very thin applications

More information

Molded High-Voltage Bushing Wells

Molded High-Voltage Bushing Wells 66-10 Molded High-voltage Bushing Wells Howard Industries Components Division Molded High-Voltage Bushing Wells Catalog Section 66-10 INTRODUCTION Howard Industries molded high-voltage bushing wells are

More information

Ball Valve Manual Balance Hose Kits - Submittal

Ball Valve Manual Balance Hose Kits - Submittal Ball Valve Manual Balance Hose Kits - Submittal Hose Kit Size *MFR 1/2" 5 3/4" 11 1" 20 1-1/4" 30 **1-1/2" 44 **2" 78 Qty. *MFR (Max. Flow Recommendations) calculated at 8 fps. **1-1/2 and 2 hose kits

More information

Emergency Stop Devices

Emergency Stop Devices New! Selection and Application of.. 278 Emergency Stop Rope Pull Switches........... 279 New! Emergency Stop Push Buttons............... 293 Banner Engineering Corp. Minneapolis, MN U.S.A. bannerengineering.com

More information

DUPLEX STRAINERS BULLETIN NO KECKLEY COMPANY 3400 Cleveland Street P.O. Box 67 Skokie, Illinois 60076

DUPLEX STRAINERS BULLETIN NO KECKLEY COMPANY 3400 Cleveland Street P.O. Box 67 Skokie, Illinois 60076 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/keckley.php 800-876-006 847-6-066 BULLETIN NO. 9400- DUPLEX STRAINERS Shown with Optional Differential Pressure Indicator KECKLEY COMPANY 400

More information

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2  Certifications W isolating General Data Rated input voltage 208 - Rated output voltage 24-230 Vac Rated power 100-3200 VA Insulation class B Maximum ambient temperature 40 C Efficiency up to 96 % Degree of protection IP

More information

Smallest Connector with Removable Contacts

Smallest Connector with Removable Contacts 1 Ultra-Miniature 8STA Size 01 Connectors Smallest Connector with Removable Contacts Ultra compact design and very lightweight connector dedicated to the harshest of motorsport environments. Innovative

More information

MR98 Series Backpressure Regulators, Relief and Differential Relief valves

MR98 Series Backpressure Regulators, Relief and Differential Relief valves MR98 Series Instruction Manual January 2015 MR98 Series Backpressure Regulators, Relief and Differential Relief valves P1757 TyPe MR98L P1753 TyPe MR98H D103588X012 Figure 1. Typical MR98 Series Backpressure

More information

NEW PRODUCT. Turn to the Harris. Pros

NEW PRODUCT. Turn to the Harris. Pros NEW PRODUCT Turn to the Harris IRONWORKER KITS Pros harris makes a wide variety of industrial grade IRONWORKER KITS metalworking outfits. professionals know that when they want to get the job done fast

More information

Model Number Structure

Model Number Structure Solid State Relays Refer to Safety Precautions for All Solid State Relays. Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via

More information

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC Solid State Relays G3NE Compact, Low-cost, SSR Switching 5to20 A Wide load voltage range: 75 to 264 VAC. Dedicated, compact aluminum PCB and power elements used. Built-in varistor effectively absorbs external

More information

Grounding Clamp. Pins and Ball-Socket Clamps for Temporary Grounding

Grounding Clamp. Pins and Ball-Socket Clamps for Temporary Grounding Grounding Clamp Pins and Ball-Socket Clamps for Temporary Grounding Pins and Ball-Socket Clamps have been designed to solve several temporary grounding situations, where the physical space or the contact

More information

4F3*0E Series Discrete valve: Body porting Internal structure and parts list

4F3*0E Series Discrete valve: Body porting Internal structure and parts list 4F3* eries iscrete valve: Body porting Internal structure and parts list 4F3 (File name: Page 5 or nding 6) 4F3 (File name: Page 5 or nding 6) Rp/8 Rp/8 33 4 4 4 4 7.5 3-4.5 dia. 8 3 release 33 3-4.5 dia.

More information

Straight Gas Ball Valve, FIP x FIP

Straight Gas Ball Valve, FIP x FIP Series 0190200 Straight Gas all Valve, FIP x FIP S 3-88 5 psig, Z21.15a 1/2 psig SME 16.33 1 2 3 4 5 6 1 Nut Forged Steel STM-ISI-1010 2 Handle luminium, Red Enamel 3 Washer PTFE 4 O-Ring NR 5 Stem Forged

More information

Available materials: Stainless steel AISI 304 (Application in wet areas). Stainless steel AISI 316 (Application in aggressive areas).

Available materials: Stainless steel AISI 304 (Application in wet areas). Stainless steel AISI 316 (Application in aggressive areas). Manual hose reel type STKi2 The manual hose reel type STKi2 with closed hub is suitable for all industrial and vehicle applications. While extending the drum hub and the cross braces the length of the

More information

DUPLEX STRAINERS 800-KECKLEY ( ) BULLETIN NO / FAX: 847/ WEB SITE:

DUPLEX STRAINERS 800-KECKLEY ( ) BULLETIN NO / FAX: 847/ WEB SITE: BULLETIN NO. 9400- DUPLEX STRAINERS 800-KECKLEY (800-2-9) 847/674-8422 FAX: 847/674-206 E-MAIL: SALES@KECKLEY.COM WEB SITE: WWW.KECKLEY.COM NO QUESTION. WE HAVE THE ANSWERS. Shown with Optional Differential

More information

Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind.

Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind. Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind. Available materials: Steel, powder coated, RAL7032, RAL3000 (Application

More information

CENELEC SERIES. SXTB Page 2,3,4 EExe T6 IP66. ASTH Page 5,6,7,8. STH Page 9,10,11,12 EExd B T6 IP66. EXPLOSION PROOF TESTING EQUIPMENT Page 13,14

CENELEC SERIES. SXTB Page 2,3,4 EExe T6 IP66. ASTH Page 5,6,7,8. STH Page 9,10,11,12 EExd B T6 IP66. EXPLOSION PROOF TESTING EQUIPMENT Page 13,14 CENELEC SERIES SXTB Page,3,4 EExe T6 IP66 ASTH Page 5,6,7,8 EExe T6 IP66 STH Page 9,0,, EExd B T6 IP66 TESTING EQUIPMENT Page 3,4 INCREASED SAFETY TERMINAL BOX (EExe T6) SXTB APPLICATION: SPECIFICATION:

More information

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with

More information

ANACONDA SEALTITE CONDUIT TYPE NMFG BLUE

ANACONDA SEALTITE CONDUIT TYPE NMFG BLUE ANACONDA SEALTITE CONDUIT TYPE NMFG BLUE All-plastic, medium mechanical strength, food grade conduit.. NMFG is a conduit specially made for the food industry. The smooth jacket of FDA approved compound

More information

Daikin Fire Rated Hoses & Hose Kits for Water Source Heat Pumps. Catalog People and ideas you can trust.

Daikin Fire Rated Hoses & Hose Kits for Water Source Heat Pumps. Catalog People and ideas you can trust. Daikin Fire Rated Hoses & Hose Kits for Water Source Heat Pumps Catalog 1196-8 People and ideas you can trust. Contents General Information... 4 Daikin Water Source Heat Pump Hoses & Hose Kits 4 Summary

More information

FIBER OPTIC CLOSURES

FIBER OPTIC CLOSURES FIBER OPTIC CLOSURES In-line type and dome type - series CLS-I, CLS- IF2X, CLS-D, CLS-DF2X144 and CLS-DF2X240 PACIFIC INTERCONNECTIONS - connecting the world with fiber optics IN-LINE TYPE FIBER OPTIC

More information

OAsys OP0XX, Issue 01, February Outside Plant. Metallic joint closure NXOK 10 units. Features and Benefits

OAsys OP0XX, Issue 01, February Outside Plant. Metallic joint closure NXOK 10 units. Features and Benefits Metallic joint closure NXOK 10 units for OPGWs with steel tubes and for optical cables Prysmian Part Number: See the page no. 3 6 The NXOK 10 joint closure units are designed to be used for jointing optical

More information

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B A High-capacity, High-dielectricstrength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated coil that handles

More information

Hydraclaw Jacks. *dimensions are in mm. Powerful: 5 tonne capacity on head or toe. High Lift: 178mm. Fast Operation: 5.5mm lift per stroke

Hydraclaw Jacks. *dimensions are in mm. Powerful: 5 tonne capacity on head or toe. High Lift: 178mm. Fast Operation: 5.5mm lift per stroke Hydraclaw Jacks Powerful: 5 tonne capacity on head or toe High Lift: 178mm Fast Operation: 5.5mm lift per stroke Stable: Substantial base offers stability under load Versatile: Horizontal or vertical operation

More information

2-3-5 Valve Manifolds

2-3-5 Valve Manifolds 2-3-5 Valve Manifolds range of Valve Manifolds offer a safe and economical method of installation to control and measure pressure of liquids and gaseous media. They are ruggedly manufactured and precision

More information

Valves valves

Valves valves Valves 4.0 4.0 valves 4.0 Index Gate valves Angle valves In-Line valves All-Metal valves Precision Leak valves Bottle gas valve 2-3 4 5 6 7 8 4.0 gate valves 1 Gate Valves 4.1 Our gate valve is manufactured

More information

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing FLFE..L FLF..L - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time Ex e terminal board housing Simplified maintenance 4 Joule shock resistant borosilicate glass White painted

More information

FBO-10 and FBO-14. Fuel Filter/Water Separator For High-Flow Applications. Product Features. Contact Information

FBO-10 and FBO-14. Fuel Filter/Water Separator For High-Flow Applications. Product Features. Contact Information FBO-0 and FBO-4 Fuel Filter/Water Separator For High-Flow Applications These versatile housings have three filter options to meet various requirements: a fuel filter/water separator, a silicone treated

More information

ACCESSORIES 5:05 5:05 PRODUCT CATALOGUE 189

ACCESSORIES 5:05 5:05 PRODUCT CATALOGUE 189 ACCESSORIES 5:05 5:05 PRODUCT CATALOGUE 189 HYDROSCAND ACCESSORIES PRODUCT GROUP 500, 505, 507 OCH 510 This product group includes products that complement Hydroscand s range of hoses and fluid connectors,

More information

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction Emergency Stop Switch Install in 22-dia. or 25-dia. Panel Cutout Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1,. Safety Lock Mechanism prevents misuse.

More information

General-purpose Relay

General-purpose Relay General-purpose Relay A Miniature Power Relay Equipped with arc barrier. Withstand : 2,000 V. RC+Y LR Ordering Information Open Relays Type Contact form Plug-in/solder terminals Plug-in/solder terminals

More information

Pushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Pushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction Pushbutton Switch Install in 22-dia. or 25-dia. Panel Cutout Easy mounting and removal of Switch Unit. Increase wiring efficiency with three-row mounting of Switch Unit. Finger protection mechanism on

More information

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops Power Relay A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated

More information

Dual-Lock. dixonvalve.com Customer Service:

Dual-Lock. dixonvalve.com Customer Service: UFCTURING QULITY SERVICE MNUFCTURING QULITY SERVICE MNUFCTURING QULITY SERVICE MNUFCTU Dual-Lock dixonvalve.com Customer Service: 877.963.4966 Quick cting Couplings Dual-Lock couplings allow full air flow

More information

MR95 Series Pressure Regulators

MR95 Series Pressure Regulators Instruction Manual MR95 Series October 2014 MR95 Series Pressure Regulators P1757 TYPE MR95L P1753 TYPE MR95H PRESSURE REDUCING REGULATORS Figure 1. Typical MR95 Series Pressure Regulators D103587X012

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Safety Interlock Switches TL4024 Safety Interlock Switch with uard Door Locking High locking force of 1,500 N (7 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure withstands

More information

SFC /SFCS

SFC /SFCS FLAME-PROOF EXPLOSION- PROTECTED FLEXIBLE CONDUIT (d2g4) Type Number System SFCS- Size Length (5:500mm, 7:700mm, 10:1000mm) Stainless Steel Coupling Part Description Used in the hazardous locations as

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-5480 www.cmafh.com Safety Interlock Switches TL19 Safety Interlock Switch with uard Door Locking High

More information

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing Pushbuttons toggle switch 6,35 mm dia. toggle switch 6,35 mm dia. no. of poles material of contacts Switching position connection method colour part no. 2 silver 2 (maintained chromiumplated 02.17312.21

More information

General Purpose High Power PCB Relays

General Purpose High Power PCB Relays T9 Series Two-pole 3A PCB or Panel Mount Relay n A, form A (NO) and form C (CO) switching capability n Designed to control compressor loads to 3.5 tons, LRA / 5.3FLA n Meets requirements of UL 58 and UL

More information

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product 996A106032 TUM 1024 REV. E 06.02.14 Tranberg AS P.O. Box 8033 N-4068 Stavanger

More information

The Shand & Jurs Model Pressure Relief Vent

The Shand & Jurs Model Pressure Relief Vent PRODUCT DATA SHEET Designed for high efficiency & economy Provides maximum flow capacity Reduces maintenance and replacement costs Suitable for corrosive and toxic applications Standard flange base for

More information

Eclipse Hermetic Gas Boosters Series HB

Eclipse Hermetic Gas Boosters Series HB Datasheet 620 7/6/2012 Eclipse Hermetic Gas Boosters Series HB Version 1.1 Type Designations The booster is identified by catalog model, assembly number, and ordering part number. The catalog model number

More information

Plug-in/solder terminals with LED indicator

Plug-in/solder terminals with LED indicator General-purpose Relay LY Electromechanical Relays A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole

More information

Safety Interlock Switches

Safety Interlock Switches r Safety Interlock Switches TL19 TL19 Safety Interlock Switch with uard Door Locking High locking force of 10 N (270 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure enables

More information

Data Sheet for Precision Potentiometer

Data Sheet for Precision Potentiometer AL(R)17/19 soldering lugs The AL(R)17/19 potentiometers in 22 mm housing are suitable for applications where a precise and economical multiturn potentiometer is important. Economical and precise multiturn

More information

BROEN-LAB UNIFLEX FITTINGS FOR WATER BROEN-LAB UNIFLEX TM FITTINGS FOR WATER

BROEN-LAB UNIFLEX FITTINGS FOR WATER BROEN-LAB UNIFLEX TM FITTINGS FOR WATER BROEN-LAB UNIFLEX FITTINGS FOR WATER TABLE OF CONTENTS Content Page Table of Contents 2 BROEN-LAB UniFlex TM BASIC 4 Product Overview 5 Water Fittings Bench Mounted Fitting with Swivel Spout... 6 Single

More information

General-Use Auto-Tuning HPX-T Series

General-Use Auto-Tuning HPX-T Series General-Use Auto-Tuning HPX-T Series Built-in Hyper-tuning automatically adjusts scanning characteristics. Adjustment steps, results and scanning conditions are digitally displayed by LED. Digital display

More information

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no. NH fuse-switch-disconnector NH fuse-switchdisconnector ~ 690V screw fixing of disconnectors onto plates size rated current in A no. of poles terminal version art. group 00 160 1 screw M8 both sides F229292

More information

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE CP-ST Stainless steel centrifugal pumps CP-ST4 Pump body: stainless steel AISI 304 Impeller: stainless steel AISI 304 Shaft: stainless steel AISI 431 CP-ST6 Pump body: stainless steel AISI 316L Impeller:

More information

tttttt www.wealdelectronics.com This publication is issued to provide outline information only and unless specifically agreed to the contrary by WEALD ELECTRONICS LTD. in writing, is not to form part of

More information

B-Series Switches Pressure, Differential Pressure, Temperature & Hydraulic

B-Series Switches Pressure, Differential Pressure, Temperature & Hydraulic B-Series Switches Pressure, Differential Pressure, FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills

More information

MR95 Series Pressure Regulators

MR95 Series Pressure Regulators Instruction Manual D103587X012 MR95 Series July 2017 MR95 Series Pressure Regulators TYPE MR95L TYPE MR95H PRESSURE REDUCING REGULATORS Figure 1. Typical MR95 Series Pressure Regulators Specifications

More information

Inch Solvent Cement Sockets

Inch Solvent Cement Sockets abs Durapipe VKD Double Union Ball Valve Description: In-line double union ball valve Seats: PTFE End Connections: Solvent Sockets, Option: Electric or Pneumatic Actuation 3 /8 HO DKA 101 58.00 1 /2 HO

More information

Flange. Connection Trunnion Ball Valves.

Flange. Connection Trunnion Ball Valves. Flange Connection Trunnion Ball Valves www.smstork.com TRUNNION BALL VALVES Where to use On/Off Shore Oil and Gas Production Subsea Oil and Gas Production Oil and Gas Storage Oil and Gas Transportation

More information

a Nexans company Catalogue 2009

a Nexans company Catalogue 2009 a Nexans company Catalogue 2009 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium

More information

Strut Clamp Pipe & Conduit

Strut Clamp Pipe & Conduit PRODUCT SPECIFICATIONS 0F Strut Clamp Pipe & Conduit Size: Steel pipe sizes 2" through 0" Finish: Electro-Galvanized Pipe clamps are designed to fit into the opening of 5 /8" wide channel profiles Pre-Assembled

More information

Russellstoll. Electrical Interconnection Systems. Dura-Gard Nonmetallic Waterproof Connections. The Next Generation: Dura-Gard

Russellstoll. Electrical Interconnection Systems. Dura-Gard Nonmetallic Waterproof Connections. The Next Generation: Dura-Gard Dura-Gard Washdown Duty, Chemical, Outdoor, Industrial and Marine Use Nonmetallic Plugs, Connectors Receptacles and Inlets 20, 30 and, Maximum 600 VAC/250 VDC The Next Generation: Dura-Gard Severe environments

More information

5. Exploded Views and Parts List 5-1 Indoor Unit

5. Exploded Views and Parts List 5-1 Indoor Unit 5. Exploded Views and Parts List 5-1 Indoor Unit 5-1 Exploded Views and Parts List Parts List No. Code No. Description Specification Q TY AQV09VBAN AQV12VBAN 1 DB92-00927C ASSY PANEL FRONT ASS Y 1 1 SA

More information

Section 4 Strapping & Accessories

Section 4 Strapping & Accessories Section 4 Contents Cable Ties...114 Edge Protectors...111-112 Lashing...113 Poly Strapping...101-102 PET Strapping...109 Poly Strapping Tools...103 Poly Woven Strap...104 Rope...113 Strapping Seals...98-99

More information

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage SSR Power Controller SSR 1 SSR 2 SSR 3 Phase Single 2 Leg Switching 3 Phase DIN Rail/Panel Mounting Both Both Both Cooling Fan Optional Optional Optional Control MethodZero Cross Trigger / high isolation

More information

Trunk Connection Type (provided) FNPT (Std.) MNPT FSWT

Trunk Connection Type (provided) FNPT (Std.) MNPT FSWT Siemens PICV 2-Way Automatic Balance Hose Kits - Submittal Hose Kit Size Normally Closed Flow Range 1/2 L.3-2.7 1/2 L.2 -.9 1/2 H 1.0-7.5 1/2 H.5-2.5 3/4 L.5-4.5 3/4 L 1.0-5.8 3/4 H 1.0-8.9 1 1.0-8.9 1-1/4

More information

Advanced Customization Type 1. White Paper

Advanced Customization Type 1. White Paper Advanced Customization Type 1 White Paper Table of contents Introduction... 4 Scope... 6 Special dimensions... 6 Machining... 8 Finish... 10 Mounting facilities... 14 Assembly... 18 Printed panels...

More information

PortesPivotantes PivotTüren Porta-a-Bilico PivotDoors Taatsdeuren Пивот-дверь от компании PuertasPivotantes. يروحملا بابلا 轴门 PortasPivotantes

PortesPivotantes PivotTüren Porta-a-Bilico PivotDoors Taatsdeuren Пивот-дверь от компании PuertasPivotantes. يروحملا بابلا 轴门 PortasPivotantes PortesPivotantes PivotTüren Porta-a-Bilico PivotDoors Taatsdeuren Пивот-дверь от компании PuertasPivotantes يروحملا بابلا 轴门 PortasPivotantes -90 0 0 90 90 2 165 mm 143 mm 8 mm 4 5 6 7 8 9 10 11 12 13

More information

Data Sheet for Precision Potentiometer

Data Sheet for Precision Potentiometer The ALI(R)17/19 potentiometers in mm housing are suitable for applications where a precise multiturn potentiometer increased radial shaft loads is important. ALI(R)17/19 reinforced bearing ALI(R)17/19

More information

Technical Specifications

Technical Specifications Standard couplings with poppet valve. Faster interchangeability (except size 12,5). Standard couplings for general purpose applications with poppet valve shut-off system. Faster proprietary profile ( 1/2

More information

Hoses for foodstuff and drink processing. Food quality hoses

Hoses for foodstuff and drink processing. Food quality hoses Hoses for foodstuff and drink processing for various food and beverage industrial processes Oy s food quality hoses are produced on clean anodized aluminium mandrels by experienced professionals. This

More information

SafeSite. Series LED Based Signaling for Hazardous Locations

SafeSite. Series LED Based Signaling for Hazardous Locations SafeSite Series LED Based Signaling for Hazardous Locations Index 02 SafeSite L-864 Red LED Beacon 03 SafeSite LED Based L-864/L-865 Flashing Dual (White/Red) Strobe 04 SafeSite L-810 Red LED Obstruction

More information

Feature. Model comment JG 3NA B L - B - D3

Feature. Model comment JG 3NA B L - B - D3 Feature Device type universal nut terminals with safety protective cover -A Power Output Rated load voltage 20VAC/VAC Triac power switch Have DC-AC (DC signal to control the AC load) AC-AC (AC signal to

More information

T&B Fittings. Industrial Fittings. Liquidtight Flexible Nonmetallic Conduit Fittings. Specifications Type A Conduit Fittings

T&B Fittings. Industrial Fittings. Liquidtight Flexible Nonmetallic Conduit Fittings. Specifications Type A Conduit Fittings T& Fittings Liquidtight Flexible Nonmetallic onduit Fittings Specifications Type onduit Fittings Series 6302 Liquidtight Flexible Nonmetallic onduit Fittings pplication To provide a liquidtight, dustight

More information

CEELOK FAS-T CONNECTORS

CEELOK FAS-T CONNECTORS CEELOK FAS-T CONNECTORS Small Form Factor, Field Terminable Connectors CeeLok FAS-T connectors ofer a small form factor, ield terminable I/O connector capable of 0 Gb/s Ethernet. Crimpsnap contacts enable

More information

NK Multi-stage submersible pumps

NK Multi-stage submersible pumps NK Multi-stage submersible pumps PERFORMANCE RANGE Flow rate up to 120 l/min (7.2 m³/h) Head up to 10 m APPLICATION LIMITS Maximum liquid temperature +40 C Maximum sand content 0 g/m³ 20 m maximum immersion

More information

TECHNICAL DATA SHEET

TECHNICAL DATA SHEET ITEM: Eurocoup flexible couplings, flange adapters and dismantling joints PN6. Place of Manufacturer: Rozenobel 15 City Country Sizes: DN 50 - mm. 6 Bar Flangeadapterbody: Flangeadapterbody: PAS 30 Follower

More information

LSC19 Lighting Cable Assemblies and Connectors

LSC19 Lighting Cable Assemblies and Connectors PowerFLEX Cable Assemblies PowerPARTS Wiring Devices ISO 9001:2008 LSC19 Lighting Cable Assemblies and Connectors PowerFLEX and PowerPARTS Introducing a new generation of Lex Products 19 pin, 6-circuit

More information

WARNING DEVICES ATEX. V.le Rimembranze, Sesto S. G. (MI) ITALY Ph.: a.r. Fax:

WARNING DEVICES ATEX. V.le Rimembranze, Sesto S. G. (MI) ITALY Ph.: a.r. Fax: WARNING DEVICES G1 : EExd IIB ROTARY SYREN MCL - MCL/S G2 : EExd IIB ELECTRIC HORN ETH G3 : EExd IIC DOUBLE TONE ACOUSTIC WARNING SACK G4 : EExd IIC FLASHING BEACON EVC/F G5 : EEx de IIC FLASHING VISUAL

More information

4567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901 23456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234567890123

More information

Insulated Scissors. Handles made with shock-proof plastic. Length Blade Std. Part No. Type mm shape Pk.

Insulated Scissors. Handles made with shock-proof plastic. Length Blade Std. Part No. Type mm shape Pk. Cutting Tools Cable Cutter - For copper and aluminum cables only. Extremely high cutting capacity with adjustable screw joint. for cable Length Std. Part No Type Ømm mm 2 AWG mm Pk. AP1017 N 15 50 1/0

More information

Toll Free:

Toll Free: Breathing Air Supply Hose Bullard offers a variety of hoses and fittings to deliver breathable air to the worker from a clean air source. V5 Series Coiled hose is ideal for working at varying distances

More information

Product Guide LED OBSTRUCTION LIGHTS

Product Guide LED OBSTRUCTION LIGHTS Product Guide LED OBSTRUCTION LIGHTS Certified to: FAA AC NO: 150/5345-43F FAA Engineering Brief No. 67 Compliant to: ICAO Annex 14, 4th Edition, July 2004 ICAO Aerodromes Design Manual, Chapter 18 Canadian

More information

technical documentation

technical documentation FritsJurgens Pivot Door System technical documentation FRITSJURGENS MPDS-S0 RVS F9000-SERIES 1 index 4 7 product description content of hinge package setting options 15 mm 11 14 technical drawings optional

More information

Fiber attachment (E39-F9) 1.4 dia. 1 dia. (2) E32-TC200B dia. 1.2 dia max. Optical fiber, 2.2 dia Fiber attachment (E39-F9) 0.5 dia.

Fiber attachment (E39-F9) 1.4 dia. 1 dia. (2) E32-TC200B dia. 1.2 dia max. Optical fiber, 2.2 dia Fiber attachment (E39-F9) 0.5 dia. s Through-beam (Sold in Pairs) E2-TL (T = 2.) M2.6 x (for M) 1. dia. 0.5 (nickelplated brass) M x Optical fiber, 2.2 dia. 0. E2-T12L 1. dia. 2. dia. (nickel-plated brass) dia. Optical fiber, 2.2 dia..2

More information

UNODOS + / FLOCDOS +

UNODOS + / FLOCDOS + Operation manual UNODOS+ / FLOCDOS+ (01-09) page 1 of 7 UNODOS + / FLOCDOS + Table of contents page 1. Technical description... 2 1.1 The function... 2 1.2 Technical details... 2 1.3 The dosing performance...

More information

Ground Clamps Cable Tray

Ground Clamps Cable Tray COMMERCIAL AND INDUSTRIAL FITTINGS: GROUNDING FITTINGS AND SOLDERLESS CONNECTORS Clamps Cable Tray Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both

More information

HPF Series. Fiber Units. Wide range of models for various applications and environments COMPATIBLE AMPLIFIERS HPX-AG HPX-ET HPX-T

HPF Series. Fiber Units. Wide range of models for various applications and environments COMPATIBLE AMPLIFIERS HPX-AG HPX-ET HPX-T Fiber Units HPF Series Wide range of models for various applications and environments COMPATIBLE AMPLIFIERS Type Catalog listing Appearance Digital fiber-optic sensors HPX-AG Gang-mounted distributed remote

More information

Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h. Manufacturer. Model number/type. Production year. page

Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h. Manufacturer. Model number/type. Production year. page Centrifugal fan with closed fan wheel that is used at source extraction from air pollulant or chip making work processes. The transported air may not contain adhestive or sticky fumes or dust. Work area:

More information

industrial ball valves

industrial ball valves Industrial Ball Valves Index 2-Piece Ball Valve 7510 1 3-Piece Ball Valve 7520 2 3-Piece Ball Valve with Gyrolok Tube End Fittings 7520 3 High Tolerance Thread Specification 4 Family Features Low Pressure

More information